| 1 | 23.1.1.1 Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe.Group A |
| 2 | 23.1.2.1 Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copperconductor cable in 1.6 mm thick MS conduit pipe.Group A |
| 3 | 23.1.4.1 Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as requiredGroup A |
| 4 | 23.1.5.1 Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as requiredGroup A |
| 5 | 23.1.6.1 Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required.1 run of Size 1.50 Sqmm(1/1.40mm) |
| 6 | 23.1.6.31 run of Size 4 Sqmm(1/2.24mm) |
| 7 | 23.1.6.62 run of Size 1.50 Sqmm(1/1.40mm) |
| 8 | 23.6.6.1 Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.MS Pipe of 20 mm dia. |
| 9 | 23.6.6.2 MS pipe of 25 mm dia. |
| 10 | 23.7.6.1 Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.PVC pipe of 20 mm dia. |
| 11 | 23.7.6.2PVC pipe of 25 mm dia. |
| 12 | 23.8.1.1 FITTING AND ACCESSORIESProviding and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect.Switch 5 amp. on existing sheet. |
| 13 | 23.8.1.2 Wall socket 5 amp on existing sheet. |
| 14 | 23.8.1.315 amp. switch on existing sheet. |
| 15 | 23.8.1.46 pin 15 multi socket on existing sheet |
| 16 | 23.8.1.5Ceiling rose flush/surface type |
| 17 | 23.8.1.6Call bell 220/230 volts musical type |
| 18 | 23.8.1.12Bakelite angle/straight button holder large size. |
| 19 | 23.8.1.13 Socket size rotary step type Electronic regulator for A.C. ceiling fan |
| 20 | 23.8.4 Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. |
| 21 | 23.9 Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. |
| 22 | 23.11 Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust sidecomplete as required |
| 23 | 23.12 Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required |
| 24 | 23.20 Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required. |
| 25 | 23.22.1.3 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.TRIPLE POLE MCCB 16 to 100 Amp 25 KA |
| 26 | 23.22.1.4 TRIPLE POLE MCCB 125 to 160 Amp 25 KA |
| 27 | 23.22.1.7 TRIPLE POLE MCCB 400 Amp 50 KA |
| 28 | 23.22.1.8 TRIPLE POLE MCCB 600 to 800 Amp 50 KA |
| 29 | 23.22.4.2 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work.SPN DBDouble Door 8 way ( 2 incoming and 6 outgoing) |
| 30 | 23.22.4.5 TPN DBHorizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) |
| 31 | 23.22.4.7 TPN DBHorizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) |
| 32 | 23.22.4.8 TPN DBHorizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) |
| 33 | 23.22.5.1 Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:-6 amp. to 32 amp Single Pole |
| 34 | 23.22.5.76 amp. to 32 amp MCB\"s FOUR POLE |
| 35 | 23.22.5.840 amp to 63 amp. MCB\"s FOUR POLE |
| 36 | 23.22.7 Supply and erection of blanking sheet in existing distribution board. |
| 37 | 23.23.1.3 Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):-Size 25 mm dia |
| 38 | 23.23.2.2 Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required.20 mm dia |
| 39 | 23.24.1 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. |
| 40 | 23.24.2.1 Panels/Feeder Pillars having incomers up to Four pole 200 A , Base Mounting frame made of ISMC 100*50*5 mm |
| 41 | 23.24.2.2 Panels/Feeder Pillars having incomers of more than 200 A and up to Four pole 400 A , Base Mounting frame made of ISMC 150*75*5.7 mm |
| 42 | 24.1.1 Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoalor coke and salt) as required. |
| 43 | 24.1.2 Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 44 | 24.1.3 Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke andsalt) complete as required. |
| 45 | 24.1.5 Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. |
| 46 | 24.1.14 Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. stapples of same size. |
| 47 | 24.2.7.3 Supply and erection ofsuitable compression type brass cable glands for underground Cable :-25 sqmm to 50 sqmm Cable 2 to 4 Core |
| 48 | 24.2.7.470 sqmm to 95 sqmm Cable 3 to 3½ Core |
| 49 | 24.2.8.5Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work.25 sqmm |
| 50 | 24.2.8.635 sqmm |
| 51 | 24.2.8.750 sqmm |
| 52 | 24.2.8.870 sqmm |
| 53 | 24.5.2.6 S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level includingdiging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC / HDPE pipe 145/123 mm outer dia/ inner dia |
| 54 | NS items Supply and erection of under ground Aluminum Armoured cableXLPE insulated loose in existing pipe or trenches complete with necessary connection. Make RR / Havells / Polycab.25 sqmm 4 Core Ard Cable |
| 55 | 35 sqmm 4 Core Ard Cable |
| 56 | 50 sqmm 3.5 Core Ard Cable |
| 57 | 70 sqmm 3.5 Core Ard Cable |
| 58 | 240 sqmm 3.5 Core Ard Cable |