Public Works Department-PWD has published Construction Of C / O Phc Building Health Institution Level-Ii At Kungash In Distt. Kullu Hp Sh C / O Main Building As Per Architect Drawing No. 298 To 300 Job No 3390 Including Site Development As Ws And Si Work Etc C / O Phc Building Health Institution . Submission Date for this Tender is 13-04-2022. Building Work Tenders in nirmand Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Cutting in earth work all kinds of soils and disposal of excavated earth up to all leads including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains in all depths and heights including dressing of sides and ramming of bottoms, lift up tp all heights including getting out the excavated soil and disposal of surplus excavated soils as directed, within all leads including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
3 | CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (one Cement : four coarse sand) : eight graded stone aggregate 40 mm (forty millimetre) nominal size including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. Providing and laying cement concrete 1:5:10 (one cement: five coarse sand: ten crushed stone aggregate 40mm (forty millimetre) nominal size)including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (one cement : three coarse sand) : six graded/crushed stone aggregate 20 mm (twenty millimetre) nominal size) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
6 | Providing and laying damp-proof course 40mm (forty millimetre) thick with cement concrete 1:2:4 (one cement : two coarse sand: four graded stone aggregate 12.5mm (twelve point five millimetre) nominal size) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
7 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 (viscosity grade-ten) of approved quality using 1.7kg (one point seven kilogram per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
8 | Providing and laying 60mm (sixty millimetre) thick factory made cement concrete interlocking paver block of M -35 (M-thirty five) grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm (fifty millimetre) thick compacted bed of coarse sand, filling the joints with line sand etc. including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
9 | Providing, laying and jointing 250 mm (two hundred fifty millimetre) diameter glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (one cement : one fine sand) including testing of joints etc. completeincluding curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
10 | Providing and laying cement concrete 1:5:10 (one cement : five coarse sand : ten graded stone aggregate 40 mm (foty millimetre) nominal size) Half Round stoneware pipes of 250 mm (two hundred fifty millimetre) diameter including bed concrete as per standard design : 250 mm diameter S.W. pipe including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
11 | REINFORCED CEMENT CONCRETE Centering and shuttering including strutting, propping etc. and removal of form includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete for Foundation, footing basis of columns etc. and mass concrete. |
12 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
13 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like Floors etc up to any thickness. |
14 | Beams, cantilever, girders and lintelssides and soffits of beams, beam hunching, cantilevers, bressumers and lintels in anydepth in all heightfrom floor. |
15 | Columns, Pillars, Piers, Abutments, Posts and Struts |
16 | Stairs, (excluding landings) except spiral staircases |
17 | Edges of slabs and breaks in floors and walls in any width Under 20 cm (twenty centimetre) wide |
18 | Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like |
19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° (fifteen degree) landings, balconies, shelves, chhajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (one cement: one point five coarse sand: three graded stone aggregate 20 mm (twenty millimetre) nominal size) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
20 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (one cement : one point five coarse sand : three graded stone aggregate 20 mm (twenty millimetre) nominal size)including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
21 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (one cement : three coarse sand) cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (one cement : one point five coarse sand: three graded stone aggregate 20 mm (twenty millimetre) nominal size) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
22 | Providing and laying in position machine batched and machine mixed design mix M-25 (M-twenty five) grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works up to plinth level including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete |
23 | Providing and laying 25mm (twenty five millimetre) thick factory made cement concrete interlocking paver block of M -35 (M-thirty five) grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 60mm (sixty millimetre) thick compacted bed of coarse sand, filling the joints with line sand etc. including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
25 | Stone soling/boulder filling dry hand packed in under floor including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
26 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (one cement: six coarse sand: twelve graded stone aggregate 20 mm (twenty millimetre) (nominal size) up to plinth level with Cement mortar 1:6 (one cement: six coarse sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
27 | BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (seven point five) in foundation and plinth in: Cement mortar 1:6 (one cement : six coarse sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5(seven point five) in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (one cement : six coarse sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
29 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (seven point five) in foundations and plinth in : Cement mortar 1:3 (one cement : three coarse sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (seven point five) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (one cement :four coarse sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete |
31 | DOORS AND WINDOWSProviding and fixing M.S. channel frame for doors Windows (ISLC) with M.S. flat in combination and MS flat for rebate welded together to make one frame including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
32 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 (three) ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm (thirty five millimetre)thick including ISI marked Stainless Steel butt hinges with necessary screws including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
33 | Providing and fixing aluminium sliding door bolts, ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
34 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 6 mm (six millimetre) thick DOUBLE glass unit, including ISI marked M.S. pressed butt hinge bright finished of required size with necessary screws.40mm (forty millimetre) thick 2nd (second) class deodar wood OPENABLE SHUTTER including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
35 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 6 mm (six millimetre) thick DOUBLE glass unit, including ISI marked M.S. pressed butt hinge bright finished of required size with necessary screws.40mm (forty millimetre) thick 2nd (second) class deodar wood FIXED SHUTTER including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
36 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm (one point four) in both directions with wire of diameter 0.63 mm (zero point six three millimetre), for doors, windows and clerestory windows with hinges and necessary screws: 35 mm (thirty five millimetre) thick shutters including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. ( Fixed to steel windows by welding) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
38 | Providing and fixing aluminium tower bolts, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete200X10 MM (two hundred X ten millimetre) |
39 | 150X10 MM (one hundred fifty X ten millimetre) |
40 | 100X10 MM (one hundred X ten millimetre) |
41 | Providing and fixing aluminium handles, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete.125 mm (one hundred and twenty five millimetre) |
42 | 100mm (one hundredmillimetre) |
43 | 75mm (seventy five millimetre) |
44 | Providing and fixing ALUMINIUM 100 mm (one hundred millimetre) mortise latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 (AC-ten) as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
45 | Providing and fixing 115 mm (one hundred fifteen millimetre) ALUMINIUM hasp and staple (safety type) with necessary screws etc. complete includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
46 | Providing and ALUMINIUM hanging type floor door stopper with necessary screws, etc. complete including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
47 | Providing and fixing ALUMINIUM hard drawn hooks and eyes including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. 250mm (two hundred fifty millimetre) |
48 | 200mm(two hundred millimetre) |
49 | Providing and fixing ISI marked oxidized M.S. single acting spring hinges with necessary screws etc. complete 150MM (one hundred fifty millimetre) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
50 | Providing and fixing 19 mm (nineteen millimetre) thick water proof termite resistant commercial board box including shelves and shutters, the back side cupboard / cabinet shall be 8 mm (eight millimetre) thick ply and all the cut portions of shelves shall be finished with 6 mm (six millimetre) thick hard wood edging. The cut portion of shutters from all sides shall also be finished with 12 mm (twelve millimetre) thick hard wood edging. The shutter from outside shall be finished with 4 mm (four millimetre) thick veneer Ply of approved shade to match with paneling including stainless steel hinges and magnetic catcher with in all accessories etc. complete as per detailed drawing as per direction of Engineer-in-charge including all leads, lifts and carriage of material and other incidental including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
51 | FLOORING AND PANNELING Cement concrete flooring 1:2:4 (one cement: two coarse sand: four graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm (forty millimetre) thick with 20 mm (twenty millimetre) nominal size stone aggregate including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
52 | Providing and laying Precast terrazo tiles 22 mm (twenty two millimetre) thick with graded marble chips of size upto 12 mm (twelve millimetre), laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (one cement: four coarse sand) : Medium shade pigment using 50% white cement and 50% ordinary cement (NTC or Its Equivalent )including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
53 | Providing and laying Precast terrazo tiles 22 mm (twenty two millimetre) thick with graded marble chips of sizes upto 12 mm (twelve millimetre), in skirting and risers of steps not exceeding 30 cm in height, on 12 mm (twelve millimetre) thick cement plaster 1:3 (one cement : three coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : Medium shades pigment using 50% white cement and 50% ordinary cement(NTC or Its Equivalent ) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
54 | Kota stone slab flooring over 20 mm (twenty millimetre) (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1: 4 (one cement: four coarse sand): 25 mm (twenty five millimetre) thick including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
55 | Kota stone slabs 20 mm (twenty millimetre) thick in risers of steps, skirting, dado and pillars laid on 12 mm (twelve millimetre) (average) thick cement mortar 1:3 (one cement: three coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
56 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
57 | Chequered terrazo tiles 22 mm (twenty two millimetre) thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm (twenty millimetre) thick bed of cement mortar 1:4 (one cement :four coarse sand) : Medium shade pigment using 50% white cement, 50% ordinary cement including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
58 | Providing and laying Ceramic glazed floor tiles (NON SLIPPERY) of size 300x300 mm (three hundred X three hundred millimetre) (thickness to be specified by the manufacturer) of 1st (first) quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm (twenty millimetre) thick cement mortar 1:4 (one Cement : four Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm (at the rate of three point three kilogram per square metre) including pointing the joints with white cement and matching pigment etc., complete including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
59 | Providing and Fixing First Quality Ceramic glazed Floor Tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm (twelve millimetre) thick bed of cement Mortar 1:3 (one cement: three coarse sand) and jointing with grey cement slurry @ 3.3kg/sqm (at the rate of three point three kilogram per square metre)including pointing in white cement mixed with pigment of matching shade complete. Size 300x 450 mm (three hundred X four hundred fifty millimetre) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
60 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% (zero point zero eight percent) and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm (twenty millimetre) thick cement mortar 1:4 (one cement : four coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm (at the rate of three point three kilogram per square metre) including grouting the joints with white cement and matching pigments etc., SIZE 600X600 MM (six hundred X six hundred millimetre) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
61 | Providing and fixing 18 mm (eighteen millimetre) thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm (twenty millimetre)thick base cement mortar 1:4 (one cement : four coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
62 | ROOFINGProviding and fixing 0.62mm (Zero point six two millimetre) thick preprinted steel sheet in roofing with hot dipped metallic zinc coasted sheet with top coat of regular modified polyester (RNP) organic coating of 20 (Twenty) microns over 5 ( five) micronsprimer coating to back coast of polyester of 5(five) microns over 5 (five) microns primer coating including fixing with screws, pre-painted iron J or L hooks, bolts and nuts 6mm(six millimetre) diameter with pre-painted limpet and rubberwasher including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
63 | Providing and fixing ridges or hips 62 cm (sixty two centimetre) overall with 0.62mm (zero point six two millimetre) thick pre-painted steel sheets in roofing with hot dipped metallic zinc coated sheets with top coat of regular modified polyester organic coating of 20 (twenty) microns over 5 (five) microns primer coating + back coat of polyester of 5 (five) microns over 5 (five) microns primer coating including fixing with pre-painted iron J or L hooks, bolts & nuts 6mm (six millimetre) diameter & pre-painted G.I. limpet and bitumen washers complete with all accessories as required including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
64 | Providing and fixing valley 90 cm (ninety centimetre) overall 0.62mm(zero point six two millimetre thick pre-painted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyester organic coating of back coat of polyester of 5 (five) microns over 5 (five) microns primer coating including fixing with pre-painted iron J or L hooks, bolts and nuts 6mm (six millimetre) diameter with pre-painted G.I. limpet and bitumen washers complete with all accessories including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
65 | Providing and fixing 30 cm (thirty centimetre) wide, 30 cm (thirty millimetre) deepsemi- circular pre-painted sheet gutter with iron brackets 40x3mm (forty X three millimetre) size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. :0.80 mm (zero point eight zero) thick with zinc coating not less than 275 gm/m2 (two hundred seventy five gram per square metre) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
66 | Providing and fixing M.S. BP Sheet 1.66mm to 2mm (one point double to two millimetre) six thick in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-charge (Base members of steel work shall be measured & paid separately) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
67 | Supplying and installation of moisture resistant/fire resistant 6 mm(six millimetre) thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with self-drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
68 | STEEL WORK Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, kg railings, brackets, gates and similar works including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
69 | Providing and fixingPOWDER COATED aluminium work , minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-incharge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
70 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un-plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm (ten millimetre)gap for thermal expansion. (i) Single socketed pipes. 110 mm (one hundred ten millimetre) diameter including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
71 | Providing and fixing 75 mm x 75 mm (seventy five millimetre X seventy five millimetre) rounded hand rails in straight length complete in 1st (first) class Indian teak wood including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
72 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un-plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm (ten millimetre) gap for thermal expansion including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete.( I )( I ) Coupler :110 mm (one hundred ten millimetre) |
73 | ( I ) Single tee without door :110x110x110 mm (one hundred ten X one hundred ten X one hundred ten millimetre) |
74 | ( II ) Bend 87.5° (eighty senen point five degree)110 mm (one hundred ten millimetre) bend |
75 | 110 mm (one hundred ten millimetre) Shoe |
76 | FINISHING15 mm (fifteen millimetre) cement plaster on the rough side of single or half brick wall of mix 1:6 (one cement: six fine sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
77 | 20 mm (twenty millimetre) cement plaster of mix :1:6 (one cement: six coarse sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
78 | 6 mm (six millimetre) cement plaster of mix 1:3 (one cement : three fine sand) including curing and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
79 | Finishing walls with 100% (one hundred percent) Premium acrylic emulsion paint having VOC less than 50 gm/litre (fifty gram per litre) and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.:New work (Two or more coats applied @ 1.43 litre/ 10 sqm (at the rate of one point four three litre per ten square metre). Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm (at the rate of zero point nine zero litre per ten square metre). : New work (Two or more coats applied @ 1.43 litre/ 10 sqm (at the rate of one point four three litre per ten square metre) Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm (at the rate of zero point nine zero litre per ten square metre) Asian Paints includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
80 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.(Asian Paint/ Nerolac of Approved Shade ) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
81 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(Asian Paint/ Nerolac of Approved Shade ) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
82 | Finishing with deluxe multi surface paint system for interior and exteriors using primer as per manufactures specification: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm (at the rate of zero point nine zero litre ten square metre) over an under coat of primer applied @ 0.80 ltr/ 10 sqm (at the rate of zero point eight zero litre ten square metre) of approved brand and manufacture including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
83 | Providing and applying white cement based putty of average thickness 1 mm (one millimetre), of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
84 | Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary completeincluding carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
85 | Providing and laying integral cement based treatment on roofs of slabs by appling cemet slurry mixed with water proofing cement compound consisting of applying: (Dr. Fixit Pidilite Or its Equivalent)including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
86 | Providing and laying integral cement based treatment on roofs of slabs by appling cemet slurry mixed with water proofing cement compound consisting of applying: (Dr. Fixit Pidilite Or its Equivalent)including carriage of materials in all leads and lifts |
87 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials up to all leads including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
88 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm (five millimetre to ten millimetre), in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per the direction of Engineer-in-Charge including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
89 | Providing weep holes in brick masonry / stone masonry /plain reinforced concrete abutment, wing wall, return wall with 100 mm (one hundred millimetre) diametre PVC pipe extending through the full width of the structures with slope of 1(v):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7 including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
90 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
91 | Water supply and Sanitary Installations Providing and fixing G.I. (Galvanized iron) pipes complete with G.I. (Galvanized iron) fittings including trenching and refilling etc. External work including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete15 mm (fifteen millimetre) nominal bore . |
92 | 20 mm (twenty millimetre) nominal bore |
93 | 32mm (thirty two millimetre) nominal bore |
94 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40 mm (twenty five to forty millimetre) nominal boreincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
95 | Fixing water metre and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water metre and stop cock to be paid separately)includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
96 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
97 | Providing and fixing Polyethylene –Aluminium- Polyethylene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C (eighty degree centigrade), including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 (one) metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge Concealed work, including cutting chases and making good the wall etc.including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. 2025 (25 mm OD (twenty five millimetre outer dia) pipe |
98 | 1620 (20 mm OD(twenty millimetre outer dia) pipe |
99 | 1216 (16 mm OD (sixteen millimetre outer dia) pipe |
100 | Providing and fixing P.V.C. low level flushing cistern no. 502 of 10 ltr. (ten litre) capacitywith manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures completeincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
101 | Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan no. 20004 (Hindware or its Equivalent) including cutting and making good the walls and floors wherever required includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
102 | Providing and fixing white vitreous china pedestal type anglo indian water closet no. 2061 size 57x46 cm white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required including cutting and making good the walls and floors wherever required includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
103 | Providing and fixing wash basin ofsize 55cm x 40 cm (fifty five centimetre X forty centimetre)with C.I. brackets, 15 mm (fifteen millimetre) C.P. brass pillar taps, 32 mm (thirty two millimetre) C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: no.10001 hind ware including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
104 | Providing and fixing white vitreous china flat back half stall urinalwith white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5(five) litre P.V.C. automatic flushing cistern CERA 5001includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
105 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm(five hundred tenX one thousand forty millimetre) bowl depth 250 mm (two hundred fifty millimetre)(Duplex No. 6321 mat finish of Diamond ) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
106 | PProviding and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40mm (forty millimetre) diameter including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
107 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work 40mm (forty millimetre) diameter) |
108 | Providing and fixing 600x450 mm (six hundred X four hundred fifty millimetre) beveled edge mirror of superior glass (of approved quality) complete with 6 mm (six millimetre) thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
109 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931:15 mm (fifteen millimetre) nominal bore including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
110 | Providing and fixing C.P. brass long nose bib cock 15 mm (fifteen millimetre) nominal bore of approved quality conforming to IS standards and weighing not less than 810 gms (eight hundred ten grams)includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
111 | Providing and fixing C.P. brass stop cock (concealed) 15 mm (fifteen millimetre) nominal bore of standard design and of approved make conforming to IS: 8931 including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
112 | Providing and fixing C.P. brass angle valve 15 mm (fifteen millimetre) nominal bore for basin mixer and geyser points of approved quality conforming to IS: 8931 including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
113 | Providing and fixing PTMT soap Dish Holder having length of 138mm (one hundred thirty eight millimetre), breadth 102mm (one hundred two millimetre), height of 75mm (seventy five millimetre) with concealed fitting arrangements, weighing not less than 106 gms (one hundred six grams) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
114 | Providing and fixing 8 mm (eight millimetre) diameter C.P. / S.S. Jet with flexible tube up to 1(one) metre long with S.S. triangular plate to European type W.C. of quality and make as approved includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
115 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete.15mm (fifteen millimetre) |
116 | 20mm (twenty millimetre) |
117 | Providing and fixing Polyethylene-Aluminium-Polyethylene PE-AL-PE Composite tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
118 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm (fifteen millimetre) nominal boreincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
119 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete 110 mm (one hundred ten millimetre) includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
120 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete 150 mm (one hundred fifty millimetre)includingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
121 | Providing and fixing PVC floor trap of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. complete. 110 mm X 90 mm (one hundred ten millimetre X ninety millimetre) including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
122 | Providing and fixing PVC door bend with oval access door, insertion rubber washer 3 mm (three millimetre) thick bolts and nuts ISI marked complete including fixing with approved adhesive etc.including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete.I) 110mm (one hundred ten millimetre) diameter |
123 | II) 150 mm (one hundred fifty millimetre) diameter |
124 | Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. completeincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. I) 110mm (one hundred ten millimetre) diameter |
125 | II) 150 mm (one hundred fifty millimetre) diameter |
126 | Providing and fixing PVC plain double equal branch ISI marked including fixing with approved adhesive etc. completeincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. I) 110mm (one hundred ten millimetre) diameter |
127 | Providing and fixing PVC single equal branch with oval access door, ISI marked insertion rubber washer 3 mm (three millimetre) thick bolts and nuts complete including fixing with approved adhesive etc. complete including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete.I) 110mm (one hundred ten millimetre) diameter |
128 | II) 150 mm (one hundred fifty millimetre) diameter |
129 | Providing and fixing PVC collars ISI marked including fixing with approved adhesive etc. completeincludingcarriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. I) 110mm (one hundred ten millimetre) diameter |
130 | II) 150 mm (one hundred fifty millimetre) diameter |
131 | Providing and fixing PVC clamps ISI marked of approved design with steel screws and rawal plugs etc. complete including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. I) 110mm (one hundred ten millimetre) diameter |
132 | Constructing brick masonry manhole in cement mortar 1:4 ( one cement : four coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (one cement : one point five coarse sand (zone- III) : three graded stone aggregate 20 mm (twenty millimetre) nominal size), foundation concrete 1:4:8 mix (onecement : four coarse sand (zone- III) : eight graded stone aggregate 40 mm (forty millimetre) nominal size), inside plastering 12 mm thick with cement mortar 1:3 (one cement : three coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (one cement :two coarse sand :four graded stone aggregate 20 mm (twenty millimetre) nominal size) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm (ninety X eighty centimetre) and 45 cm (forty five centimetre) deep including C.I. cover with frame (Light duty) 450x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (thirty eight kilogram)(weight of cover 23 kg (twenty three kilogram) and weight of frame 15 kg (fifteen kilogram) includingcuring and carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete |
133 | Constructing soak pit 1.20x1.20x1.20 m (one point two zero X one point two zero X one point two zero metre) filled with brick bats including S.W. drain pipe 100 mm (one hundred millimetre) diametre and 1.20 m (one point two zero metre) long complete as per standard design including carriage of materials in all leads and lifts and as per directions of The Engineer – in – Charge complete. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy