Military Engineer Services-MES has published Provision Of Deficient Officers Married Accommodation 220 Dus G Plus 62 Including Demolition Of Four Blocks P Q J And K At Nofra Colaba Mumbai. Submission Date for this Tender is 01-04-2023. Building Work Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-Apr-2022 | Pre Bid Meeting | Other | 06-05-2022 |
2 | 28-Apr-2022 | Date amdt dt 28 Apr 2022 | Date | 20-05-2022 |
3 | 12-May-2022 | 87908 revised BOQ and Tender pages | BOQ | 06-06-2022 |
4 | 12-May-2022 | Date Amd dated 12 May22 | Date | 06-06-2022 |
5 | 27-May-2022 | Date amdt dt 27 May 2022 | Date | 20-06-2022 |
6 | 03-Jun-2022 | Date amendment 03 Jun 2022 | Date | 04-07-2022 |
7 | 26-Jun-2022 | date amendment | Date | 18-07-2022 |
8 | 07-Jul-2022 | 87908dateamendment | Date | 01-08-2022 |
9 | 22-Jul-2022 | Date Amdt dt 22 Jul 2022 | Date | 23-08-2022 |
10 | 12-Aug-2022 | Date Amendment 12 Aug 2022 | Date | 06-09-2022 |
11 | 26-Aug-2022 | date amd 26 Aug 2022 | Date | 21-09-2022 |
12 | 13-Sep-2022 | date amd 13Sep 2022 | Date | 12-10-2022 |
13 | 14-Sep-2022 | 87908RerevisedBOQdt14Sep22 | BOQ | 12-10-2022 |
14 | 14-Sep-2022 | RevDrgsdt14Sep2022 | Other | 12-10-2022 |
15 | 14-Sep-2022 | Furniture Drawings | Other | 12-10-2022 |
16 | 14-Sep-2022 | Revisedpagesandamddt14sep22 | Other | 12-10-2022 |
17 | 30-Sep-2022 | date amdt 30 Sep 2022 | Date | 21-10-2022 |
18 | 30-Sep-2022 | Amdt in tender pages BOQ and Drgs dt 30 Sep 2022 | BOQ | 21-10-2022 |
19 | 11-Oct-2022 | Date amdt dt 11 oct 2022 | Date | 04-11-2022 |
20 | 21-Oct-2022 | date amdt dt 21 Oct 2022 | Date | 18-11-2022 |
21 | 09-Nov-2022 | Date amendment 09 Nov | Date | 02-12-2022 |
22 | 23-Nov-2022 | Date amdt dt 23 Nov 2022 | Date | 16-12-2022 |
23 | 07-Dec-2022 | Date amdt dt 07 Dec 2022 | Date | 30-12-2022 |
24 | 20-Dec-2022 | date amendment 20 Dec 2022 | Date | 13-01-2023 |
25 | 05-Jan-2023 | Date amendment 05 Jan 2023 | Date | 27-01-2023 |
26 | 19-Jan-2023 | 87908 Revised drgs Binder 2 | Other | 13-02-2023 |
27 | 19-Jan-2023 | Amd Drgs Binder1 19 Jan 23 | Other | 13-02-2023 |
28 | 19-Jan-2023 | date amd 19 jan 23 | Date | 13-02-2023 |
29 | 19-Jan-2023 | Amd in Tender pages Drgs and BOQ | BOQ | 13-02-2023 |
30 | 04-Feb-2023 | date Amd 04 feb 23 | Date | 27-02-2023 |
31 | 20-Feb-2023 | date Amd | Date | 08-03-2023 |
32 | 22-Feb-2023 | amended tender pgs and drgs | Other | 08-03-2023 |
33 | 28-Feb-2023 | date Amd 28 Feb 2023 | Date | 15-03-2023 |
34 | 06-Mar-2023 | dt amdt 06 mar 2023 | Date | 23-03-2023 |
35 | 10-Mar-2023 | Amendment to tender dated 10 Mar 2023 | Other | 23-03-2023 |
36 | 11-Mar-2023 | Tender Amendment Dt 11 Mar 23 | Other | 23-03-2023 |
37 | 18-Mar-2023 | Date Amendment dt 18 Mar 23 | Date | 01-04-2023 |
38 | 18-Mar-2023 | Tender Amendment Dt 18 Mar 23 | Other | 01-04-2023 |
FileName | File Description | File Size |
5c23c297-2b59-46f7-893d-2b64ef8aa9c1.html | Tender Notice | 78.9 KB |
ArchDrg87A_B_D_E_F_72A.pdf | Tender Document | 10.1 MB |
ArchDrg_01SP_1-10.rar | Tender Document | 37.1 MB |
ArchDrg_11-21.pdf | Tender Document | 32.9 MB |
ArchDrg_22-30.pdf | Tender Document | 33.0 MB |
ArchDrg_31-41.pdf | Tender Document | 27.8 MB |
ArchDrg_42-49.pdf | Tender Document | 32.4 MB |
ArchDrg_50-60.pdf | Tender Document | 30.7 MB |
ArchDrg_61-75.pdf | Tender Document | 31.4 MB |
ArchDrg_76-87.pdf | Tender Document | 33.2 MB |
BOQ_576451.xls | Tender Document | 682.5 KB |
ListofDrg1_4to4_4.pdf | Tender Document | 5.6 MB |
MEP_ELECTRICAL_1-29.pdf | Tender Document | 20.0 MB |
MEP_FIRE_HVAC_1-19.pdf | Tender Document | 13.3 MB |
MEP_PLUMBING_1-24.pdf | Tender Document | 15.7 MB |
SchA_G62.pdf | Tender Document | 701.9 KB |
StrDrg_1-74.pdf | Tender Document | 34.8 MB |
StrDrg_150-224.pdf | Tender Document | 26.5 MB |
StrDrg_225-304.pdf | Tender Document | 35.5 MB |
StrDrg_75-149.pdf | Tender Document | 31.8 MB |
Tendernotice_1.pdf | Tender Document | 279.4 KB |
TP_G_62.pdf | Tender Document | 2.6 MB |
Walk_Through_Video_G62.rar | Tender Document | 31.7 MB |
Sl. No. | Item Description |
1 | SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-"A" Part-I B/F |
2 | SCHEDULE "A" PART-II (SITE CLEARANCE, EXCAVATION & EARTHWORK) Total of Sch-"A" Part-II B/F |
3 | SCHEDULE "A" PART-III (DEMOLITION / DISMANTLING) Total of Sch-"A" Part-III B/F |
4 | SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Total of Sch-"A" Part-IV B/F |
5 | SCHEDULE "A" PART-V (INTERNAL ELECTRICFICATION) Total of Sch-"A" Part-V B/F |
6 | SCHEDULE "A" PART- VI (ROAD / PATHS / CULVERT) Total of Sch-"A" Part-VI B/F |
7 | SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Total of Sch-"A" Part-VII B/F |
8 | SCHEDULE "A" PART-VIII (RAIN WATER HARVESTING) Total of Sch-"A" Part-VIII B/F |
9 | SCHEDULE "A" PART-IX (GATES AND BOUNDARY WALL) Total of Sch-"A" Part-IX B/F |
10 | SCHEDULE "A" PART-X (EXTERNAL ELECTRIFICATION) Total of Sch-"A" Part-X B/F |
11 | SCHEDULE "A" PART-XI (EXTERNAL WATER SUPPLY) Total of Sch-"A" Part-XI B/F |
12 | SCHEDULE "A" PART-XII (TREATED WATER SUPPLY) Total of Sch-"A" Part-XII B/F |
13 | SCHEDULE "A" PART-XIII (FIRE FIGHTING) Total of Sch-"A" Part-XIII B/F |
14 | SCHEDULE "A" PART-XIV (CIVIL WORKS FOR DG SET AND ELECTRICAL TRENCH [OUTSIDE BUILDING]) Total of Sch-"A" Part-XIV B/F |
15 | SCHEDULE "A" PART-XV (STANDBY POWER SUPPLY [DG]) Total of Sch-"A" Part-XV B/F |
16 | SCHEDULE "A" PART-XVI (AVIATION LIGHT) Total of Sch-"A" Part-XVI B/F |
17 | SCHEDULE "A" PART-XVII (TV/ TELEPHONE CONDUITS) Total of Sch-"A" Part-XVII B/F |
18 | SCHEDULE "A" PART-XVIII (HORTICULTURE AND LANDSCAPE) Total of Sch-"A" Part-XVIII B/F |
19 | SCHEDULE "A" PART-XIX (MISCELLANIOUS ITEMS) |
20 | SITE CLEARANCE, EXCAVATION & EARTHWORK |
21 | Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Note for 20.01 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. |
22 | DEMOLITION / DISMANTLING |
23 | Taking down PVC water tank capacity complete all as specified and directed by Engineer-in charge. |
24 | Removing demolished debris/rubbish material (except retrieved material as specified in Sch. of Credit) and depositing it outside Ministry of Defence Land. (Site Clearance - 1117.05 Cum ,Sewage Disposal - 103.40 Cum, Rain Water Harvesting - 7.80 Cum) Note for 20.01 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. |
25 | Taking down old u/s tubelight fitting of any type and capacity from walls/ceiling etc. complete all as specified and directed by Engineer-in charge. |
26 | Taking down old u/s MCB DBs complete with MCBs, Isolator etc of any type and capacity from walls/ceiling etc. complete all as specified and directed by Engineer-in-Charge. |
27 | Dismantling & Taking down old u/s submain cable of size 6 sq.mm to 50 sq.mm of any type from walls/floor/ceiling & making good to distributed surface etc. complete all as specified and directed by Engineer-in-Charge. |
28 | Taking down old u/s socket of any type and capacity from walls/ceiling etc. complete all as specified and directed by Engineer-in charge. |
29 | Taking down old u/s ceiling rose & fan regulator of any type and capacity from walls/ceiling etc. complete all as specified and directed by Engineer-in-Charge. |
30 | Taking down old u/s ceiling fan of any type and capacity from walls/ceiling etc. deposited to MES store complete all as specified and directed by Engineer-in-Charge. |
31 | Taking down old u/s changeover switch of any type complete all as specified and directed by Engineer-in-Charge. |
32 | INTERNAL WATER SUPPLY |
33 | S & F Shower arm casted 190mm long light body round shape for wall mounted showers with flange complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No : SHA-CHR-477 or equivalent in Crab Tree/Kohler |
34 | S & F Overhead shower single flow 100 mm dia (abs cp), complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: OHS-CHR-1989 or equivalent in Crab Tree/Kohler |
35 | S & F Concealed body for single lever diverter complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: ALE-ESS-055 or equivalent in Crab Tree/Kohler |
36 | S & F 1.5 / L exposed parts kit of single lever diverter complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: APR-ESS-101055NK or equivalent in Crab Tree/Kohler |
37 | S & F Aspire bath spout with wall flange complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: SPE-ESS-101429 or equivalent in Crab Tree/Kohler |
38 | S&F Chromium plated wall mixture with provision for overhead shower connection with 115 mm long bend pipe on upper side, connecting legs & wall flanges complete all as specified and directed by Engineer-in-Charge. Make -Jaquar Model No 23281 UPR GD or equivalent in Crab tree/Kohler |
39 | S & F for concealed stop cock, Regular body with adjustable wall flange, size 15mm dia with spindle extensions (without exposed parts) complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: ALD-CHR-083CQT or equivalent in Crab Tree/Kohler |
40 | S & F for Exposed Part Kit of Concealed Stop Cock complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: CQT-CHR-23083K or equivalent in Crab Tree/Kohler |
41 | S & F Angular stop cock Triangular Handle complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: AQT-CHR-3057P or equivalent in Crab Tree/Kohler |
42 | S & F Auto Closing Urinal Flush Valve complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: PRS-CHR-077 or equivalent in Crab Tree/Kohler |
43 | S & F Sink Cock with J Shaped (Table Mounted) complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: CON-CHR-359KN or equivalent in Crab Tree/Kohler |
44 | S & F two way bib cock with Flange complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: CQT-CHR-23041 or equivalent in Crab Tree/Kohler |
45 | S & FBib Cock with Wall Flange complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: CQT-CHR-23047 or equivalent in Crab Tree/Kohler |
46 | S & F Bib Cock with nozzel complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: CON-CHR-049NKN or equivalent in Crab Tree/Kohler (For Washing Machine) |
47 | S & F Hand Shower (Health Faucet) (Abs Body) complete all as specified and directed by Engineer-in-Charge. Make-Jaquar, Model No: ALD-CHR-587 or equivalent in Crab Tree/Kohler |
48 | S & F Brass Forged Pressure Reducing Valves complete all as specified and directed. Make - ZOLOTO or equivalent (Article No:1040B HSN CDE : 84811000) |
49 | a) 50mm Dia |
50 | b) 32mm dia |
51 | c) 25mm Dia |
52 | S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. Make - ZOLOTO or equivalent (HSN CDE : 84819090) |
53 | a) 65mm dia |
54 | b) 80mm dia |
55 | c) 100mm Dia |
56 | S & F, SINTEXLOFT TANK 200 LTR FDA grade material complete all as specified and as directed by the Engineer-in-Charge. |
57 | INTERNAL ELECTRIFICATION |
58 | S & F 25A shuttered socket conforming to IS: 1293-1988 for Air Conditioner complete all as specified and directed by the engineer-in-charge. Make: Havells, SAP Code:AHFKCXW253/ Legrand/ IndoAsian/ Anchor |
59 | S & F 25ASP "C" Mini MCB for Air Conditioner complete all as specified and directed by the engineer-in-charge. Make: Havells, SAP Code:DHFNCSPA025/ Legrand/ IndoAsian/ Anchor |
60 | Supplying and fixing of modular type Blanking plate with ISI mark and approved make, including necessary fixing arrangement complete all as specified and directed by the engineer-in-charge. Make: Legrand Cat No:5734 49or equivalent or equivalent in Havells/ IndoAsian/ Anchor |
61 | S & F factory made not less than 1.2 mm thick sunken, 8 module modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed by the engineer-in-charge. Make: Legrand Cat No:6890 31or equivalent in Havells/ IndoAsian/ Anchor |
62 | S & F LVDB (Low voltage DB) for TV/Telephone suitable for IP 43, Isolated Neutral bar & Shrouded bus bar, Mechanical Impact strength IK08, factory fitted Krone TV &Tel socket, Door earthing, SPN 8 Way complete all as specified and directed by the engineer-in-charge. Make: IndoAsian Cat no:811963/Havells/Legrand/L&T/ABB |
63 | Supply and fix time switches astro type MicroRex analog time switches In accordance with IEC 60730-1 and 60730-2-7 Manual switching ON/automatic/OFF Hourly/daily/weekly switching dial with captive segments Clock precision: +/– 5 min for the daily time switch –10 °C to +55 °C operating temperature (Having longitude and latitude of Indian cities in memory) 250 V of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed by the engineer-in-charge. (For Street Lights & Landcape-Decorative Lights) Make: L&T: AUTS02DIG00 or equivalent in LEGRAND/ IndoAsian/ Havells/ ABB |
64 | S & FLED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,22 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronicDriver ,connector block etc. with all assoceries intenallt prewired &includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable forand mounting clampsPVC squre box 75x75mm - 2 nos etc complete all as specified and directed by the engineer-in-charge. Make:HAVELLS LHEXBTP7IN10822 or equivalent in Crompton/ Philips/ Wipro/ Bajaj |
65 | S &FLED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,18 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronicDriver ,connector block etc. with all assoceries intenallt prewired &includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable forand mounting clampsPVC squre box 75x75mm - 2 nos etc complete all as specified and directed by the engineer-in-charge. Make:HAVELLSLHEXACP7UN1W018 or equivalent in Crompton/ Philips/ Wipro/ Bajaj |
66 | S &FLED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronicDriver ,connector block etc. with all assoceries intenallt prewired &including coneecting up with 2 core flexible cppper conductor cable with sutable size & suitable forand mounting clampsPVC squre box 75x75mm - 2 nos etc complete all as specified and directed by the engineer-in-charge. Make:HAVELLS LHEXACP7IN1W010 or equivalent in Crompton/ Philips/ Wipro/ Bajaj |
67 | S & F 13.5 W LED 6000 K Bulkhead designed for modern homes available in non PIR as well as PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed by the engineer-in-charge. Make: HAVELLS Cat No:LHEXCGP7IN5W013 or equivalent in Crompton/ Philips/ Wipro/ Bajaj |
68 | S & F Skirting Light with whiteLED- 3 Module complete all as specified and directed by the engineer-in-charge. Make: Legrand Cat No:6455 97 or equivalent in Havells/Bajaj/Crompton |
69 | S & F 20W LED batten with Microwave motion technology for providing an energy-efficient solution and with aluminum housing & integrated electronic driver,Made of Aluminum Extrusion with housing partin white finish & diffuser part in opal finish,High efficiency long life LED chips with lumen efficacy of 130lm/W with a viewing angle of120°to ensure better lumen output,Powered by an integral electronic driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other safety test as per IS:15885 Part 2/Sec 13,Can be fixed directly into the wall/ ceiling by means of mounting clips provided with the fixture complete all as specified and directed by the engineer-in-charge. Make: HAVELLS Cat No:LHEDAAP7NW1W020/ Crompton/ Philips/ Wipro/ Bajaj or equivalent |
70 | S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete all as specified and directed by the engineer-in-charge. Make : HAVELLS HSN code:8414 ES Neo Crompton Greaves/ Bajaj/Orient |
71 | S&F Exhaust fan of size 230/250 mm sweep metal body complete withand louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan complete all as specified and directed by the engineer-in-charge. (For Kitchen) Make - Havells cat no :- HSN code:8414 Ventilair DB Neo/ Bajaj/Crompton |
72 | S&F Fresh air Exhaust fanof size 230/250 mm sweep complete withand louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan complete all as specified and directed by the engineer-in-charge. (For toilets) Make - Havells Cat No :- HSN code:8414 Ventil Air-DX white/Crompton Greaves/Bajaj |
73 | S&F Exhaust fan heavy duty of size 450 mm sweep metal body complete withand louvers connecting upexhaust fan complete all as specified and directed by the engineer-in-charge. (For pump house/Substation) Make - Havells cat no :- HSN code:8414 Turbo Force SP/ Bajaj/Crompton |
74 | Supply, Installation, Testing and commissioning of 1000 mm x 100 x 2 mm thick Ladder type hot deepgalvanised cable trays including supports made with hot deep galvanised perforated sheets, structural angles, rods, anchor fasteners, nuts, washers etc. complete all as specified and directed by the engineer-in-charge. |
75 | Supply, Installation, Testing and commissioning of 600mm x 100 x 2 mm thick mm thick Ladder type hot deepgalvanised cable trays including supports made with hot deep galvanised perforated sheets, structural angles, rods, anchor fasteners, nuts, washers etc. complete all as specified and directed by the engineer-in-charge. |
76 | Supply, Installation, Testing and commissioning of 450 mm x 100 x 2 mm thick Ladder type hot deepgalvanised cable trays including supports made with hot deep galvanised perforated sheets, structural angles, rods, anchor fasteners, nuts, washers etc. complete all as specified and directed by the engineer-in-charge. |
77 | S&F Ekinox³ TPN DB-VTPN DPX³ 160 MCCB DB"sAs per IEC 61439-3 Suitable for Flush Mounting and Surface Mounting With 250 A Copper Busbar for each phase With 2 Neutral bar, 2 Earthbar and Cable ties for Cable management Fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 43 & IP 54 DB"s, With provision for DPX³ 160 MCCB as incomer and SP/TP MCB"s as outgoing,VTPN DB 6 way complete all as specified and directed by the engineer-in-charge. Make: LEGRAND CAT NO. 5077 46 or equivalent in IndoAsian/ Havells/ L&T/ ABB |
78 | S & F ISI marked MCB for till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, 25A, SPN MCB B/C- curve complete all as specified and directed by the engineer-in-charge. Make: LEGRAND Cat No: 4086 16 or equivalent in IndoAsian/ Havells/ L&T/ ABB |
79 | S & F ISI marked MCB till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, 40A, FP MCB B/C- curve complete all as specified and directed by the engineer-in-charge. Make: LEGRAND Cat No: 4087 00 or equivalent in IndoAsian/Havells/L&T/ ABB |
80 | M & L for earthing complete with galvanised steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GIstrip of size 32x6 mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and directed by the engineer-in-charge. (Internal Electrification- 10, Fire Fighting - 2, External Water Supply - 2, External Electrification - 16) |
81 | S & F modular type 1 module RJ 11 telephone socket with shuttercomplete all as specified and directed by the engineer-in-charge. Make: Legrand: 5734 26 or equivalent in IndoAsian/Havells/L&T |
82 | Supplying & erecting 50 pairs x 0.5 mm diaPVC insulated armoured telephone cable 0.5 sq.mmPVC Sheathed solid tinned copper conductor cable laid in provided trench/ cable tray complete all as specified and directed by the engineer-in-charge. Make: POLYCAB/RR Kable/Havells |
83 | Supplying & erecting 10 pairs x 0.5 mm dia PVC insulated armoured telephone cable 0.5 sq.mmPVC Sheathed solid tinned copper conductor cable laid in provided trench/ cable tray complete all as specified and directed by the engineer-in-charge. Make: POLYCAB/RR Kable/Havells |
84 | S & F for 2 pair telephone cable having solid electrolytic annealed bare copper conductor of 0.5 mm nominal diameter with high density polyethylene insulation, paired, polyester taped, nylon rip cord and grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113 C including termination complete all as specified and directed by the engineer-in-charge. Make: POLYCAB /RR Kable/Havells |
85 | S & F 5 pair telephone distribution box with suitable S.S. frame for mounting tag module, Krone module and incorporated in 16 SWG MS box with proper lockable cover. The box should be fixed on wall with suitable fasteners including painting & earthing. This also includes fixing the cable, distribution chart sufficient space for the cables, wires etc. complete all as specified and directed by the engineer-in-charge. Make: DELTA or equivalent |
86 | S & F 10 pair telephone distribution box with suitable S.S. frame for mounting tag module, Krone module and incorporated in 16 SWG MS box with proper lockable cover. The box should be fixed on wall with suitable fasteners including painting & earthing. This also includes fixing the cable, distribution chart sufficient space for the cables, wires etc. complete all as specified and directed by the engineer-in-charge. Make: DELTA or equivalent |
87 | S & F 50 pair telephone distribution box with suitable S.S. frame for mounting tag module, Krone module and incorporated in 16 SWG MS box with proper lockable cover. The box should be fixed on wall with suitable fasteners including painting & earthing. This also includes fixing the cable, distribution chart sufficient space for the cables, wires etc complete all as specified and directed by the engineer-in-charge. Make: DELTA or equivalent |
88 | S & F modular type 1 module TV socket complete all as specified and directed by the engineer-in-charge. Make: Legrand: 5734 25 or equivalent in IndoAsian/Havells/L&T |
89 | S & F for RG 11 co-axial cable having solid electrolytic grade annealed plain copper central conductor of 1.63 mm nominal diameter, gas injected physical polyethylene foam insulated, wrapped with aluminum mylar tape aluminium alloy wire braided, jelly flooded and PVC jacketed including termination complete all as specified and directed by the engineer-in-charge. Make: Polycab CO-X /RR Kable/Havells |
90 | S & F for RG 6 co-axial cable having solid electrolytic grade annealed plain copper central conductor of 1.02 mm nominal diameter, gas injected physical polyethylene foam insulated, wrapped with aluminum mylar tape aluminium alloy wire braided, jelly flooded and PVC jacketed including termination complete all as specified and directed by the engineer-in-charge. Make : Polycab CO-X /RR Kable/Havells |
91 | Supply & installation of 4-way Splitter box for TV cable termination including all necessary hardware, accessories complete all as specified and directed by engineer-in-charge. Make: STAR or equivalent |
92 | S & F RJ 45 Data Outlet Cat 6 - 1M complete all as specified and directed by the engineer-in-charge. Make: Havells SAP CODE :ACMKRWW451 or equivalent in IndoAsian/Legrand/L&T |
93 | S & F Cat 6 solid bare copper comductor 4 pair unshielded twisted pair(UTP) industrial cable for computer LAN network with grey colour & FR PVC jacket including termination with necessary required no of splitters complete all as specified and directed by the engineer-in-charge. Make:RR Kable HSN CODE:8544 or equivalent in Polycab CO-X /Havells |
94 | EXTERNAL ELECTRIFICATION |
95 | M & L for 1.1 kV grade copper conductor, XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. Make: POLYCAB /RR Kable/Havells or equivalent |
96 | a) 4.0 core 10 mm² |
97 | b) 4.0 core 6 mm² |
98 | Main Panel-1 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed. BUSBAR CHAMBER : 1250 Amps uniformly rated, continuous duty,415VAC, 3Phaseandfull size Neutral Aluminium(Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 50 KA for 1 sec. Buscoupler: Buscoupler should be close in normal operating condition & it should be open in case of fire.(when Fire panel CB gets on then buscoupler should get open) INCOMING a) 1250 A, 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications b) 01 Nos. phase indicating light through protected by 2 amps MCB’s.- 1 set.Electronic Digital Load Manager with ready |
99 | RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 1250/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, d) 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, e) Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. f) 1 no. 1250 A, 4 pole ATS suitable for 415V, 50 Hz, A.C Supply and having. Suitable ATS relay cum display panel and having auto and manual function. The ATS shall be complete as per technical specifications. OUTGOING 1) 1250 amps 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The MCCB shall be complete as per technical specifications - 02 no. 2) 630 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The MCCB shall be complete as per technical specifications-03 nos |
100 | Main Panel-2 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed. BUSBAR CHAMBER : 800 Amps uniformly rated, continuous duty,415VAC, 3Phaseandfull size Neutral Aluminium(Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 50 KA for 1 sec. Buscoupler: Buscoupler should be close in normal operating condition & it should be open in case of fire.(when Fire panel CB gets on then buscoupler should get open) INCOMING a) 800 A, 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications b) 01 Nos. phase indicating light through protected by 2 amps MCB’s.- 1 set.Electronic Digital Load Manager with ready |
101 | RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 800/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, d) 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, e) Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. f) 1 no. 800 A, 4 pole ATS suitable for 415V, 50 Hz, A.C Supply and having. Suitable ATS relay cum display panel and having auto and manual function. The ATS shall be complete as per technical specifications. OUTGOING 1) 630 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The MCCB shall be complete as per technical specifications-03 nos 2) 400 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The MCCB shall be complete as per technical specifications-02 nos |
102 | Common Area Service Panel-1 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 630 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 36 KA for 1 sec.supports, 25 KA for 1 sec. INCOMING a) 1 no. 630 A, 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. b) phase indicating light through protected by 2 amps MCB’s.- 1 set c) Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. d) 630/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, |
103 | e) 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, f) Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING 1) 2nos. 25 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. 2) 14nos. 32 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. 3) 1 nos. 40 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. 4)1 nos. 63 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 16KA. 5) 1nos. 250 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. 6) 1nos. 630 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. |
104 | Common Area Service Panel-2 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 630 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 36 KA for 1 sec.supports, 25 KA for 1 sec. INCOMING a) 1 no. 630 A, 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications b) phase indicating light through protected by 2 amps MCB’s.- 1 set c) Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. |
105 | d) 630/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, e) 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, f) Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING 1) 7nos. 32 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. 2) 1nos. 100 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. 3) 1nos. 150 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. 4) 1nos. 400 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. |
106 | Car Charging Panel Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 630 Amps uniformly rated, continuous duty,415VAC,3Phaseand full size Neutral Aluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 25 KA for 1 sec. |
107 | INCOMING a) 1 no. 630 A, 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 400/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING 1) 12 nos. 100 amps 4 pole MCCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10KA. |
108 | Lift Panel Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 250 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 25 KA for 1 sec. INCOMING a) 1 no. 250 A, 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. |
109 | c) 250/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING 1) 9 nos. 25 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10KA. 2) 8 nos. 63 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 16KA. 3) 3 nos. 32 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 16KA. |
110 | Pressurization Panel Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 100 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 25 KA for 1 sec. |
111 | INCOMING a) 1 no. 100 A, 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 100/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING 1) 12 nos. 32 amps 4 pole MCBsuitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10KA. |
112 | S & F Bolard light (Ritu Bollard-L2) ID: 6952,HEIGHT: 500MM,Dimension: Tr.130 x 500,FIXING: OVER GROUND,IP RATING: IP 65,LAMP TYPE: 9W LED ,LIGHT COLOR : WARM WHITE complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
113 | S & F Spike light (Trioscape Spike-L3), ID: 6998/99,FIXING: OVER GROUND,IP RATING: IP 65,Dimension : 72 x 117 x 430, LAMP TYPE: 1X3W LED,LIGHT COLOR : WARM WHITE complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
114 | S & F KL-8184 Two Way Connector (IP67), Dimension : , Wattage : 2 Way Connector (L3) complete all as specified and directed by engineer-in-charge. |
115 | S & F Wall recessed light (Sudo Mini - Grid Frame-L4) ID: 2756,FIXING: WALL, IP RATING: IP 65, COD : 126 x 71 x 83 LAMP TYPE: 3W LED, LIGHT COLOR : WARM WHITE complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
116 | S & F Flexible LED strip light (L5) ID:7945 12V 2835, FIXING: MOUNTED WALL, IP RATING:IP 65, Dimension : 5m / Roll LAMP TYPE:6W/M LED, LIGHT COLOR :WARM WHITE complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
117 | S & F KL-8249 Non-Waterproof power supply,12V, Dimension : , Wattage : 12V dc 2.5A 30W Power unit (L5) complete all as specified and directed by engineer-in-charge. |
118 | S & F Wall Washers ( In-Ground Luminaire-L6), ID: 4090, FIXING: COLUMN, IP RATING: IP 65, Dimension : Ø200 x 75 LAMP TYPE: 6X3W LED, LIGHT COLOR : OVER GROUND complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
119 | S & F KL-8160 2 Way Connector, Dimension, Wattage : IP68 2 Way Connector (L6) complete all as specified and directed by engineer-in-charge. |
120 | S & F Post Top Light (DOUBLE STANDARD-L1A), ID: 5340, HEIGHT: 3.0M, FIXING: OVER GROUND, IP RATING: IP 65, Dimension: Ø590 x 450, LAMP TYPE: 45 W LED , LIGHT COLOR : WARM WHITE complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
121 | S & F KP-4365 Cyclo Aluminium Lighting Pole, Ht.4000 (L1A) complete all as specified and directed by engineer-in-charge. |
122 | S & F KP-9204 Foundation Bolt, 4 Nos of M16 x 300 mm bolt with 2 Nuts & 2 Washer (L1A) complete all as specified and directed by engineer-in-charge. |
123 | S & F Post top Light (Recta Polar Lighting Ploe-L1) ID: KP-7234, HEIGHT: 9.0M,FIXING: OVER GROUND, IP RATING: IP 65 LAMP TYPE: 2x60W LED , LIGHT COLOR : WARM WHITE complete all as specified and directed by engineer-in-charge. Make : K-LITE or equivalent |
124 | S & FKP-9206 Foundation Bolt, 4 Nos of M20 x 500 mm bolt with 2 Nuts & 2 Washer (L1) complete all as specified and directed by engineer-in-charge. |
125 | Supply, installation, testing and commissioning of sandwich type (3P4W,100%N), busbar trunking system complete with two runs of 25 mmX 3mm aluminium earthing strip and accessories all as specified and directed. Make: L&T/Schneider/ ABB/ Siemens The busbar trunking system shall conform to the following technical specifications: i] System details : The Busbar Trunking System shall be suitable for operational Voltage of 415V / 690V / 1000V with supply frequency of 50Hz / 60Hz, minimum insulation voltage of 1100V & impulse withstand voltage of 8kV & higher. ii]Standards : The Busbar Trunking System shall be designed to comply in accordance with the following international standards, IEC 61439 – Part 1: Low voltage switchgear & controlgear assembly- General rules IEC 61439 – Part 6: Busbar Trunking Systems (busways) IEC 60529: Degree of protection IS 8623 – Part 2: Specification for Low Voltage Switchgear & Controlgear Assemblies IS 1893 – Part 1: Criteria for Earthquake Resistant Design of Structures IEEE 693:2005: High Seismic Qualification Level Wherever required and specified, the Busbar Trunking System shall conform to Fire Rating of 600 deg C for 2 Hours. Busbar Trunking System should also have Seismic Zone-5, Flame Propagation and Fire Resistance certification. iii]General : The Busbar Trunking System shall be of sandwich construction, non-ventilated and natural cooled design. It shall be possible to |
126 | mount the Busbar Trunking System in any orientation without affecting the current rating. iv]Busbars : 1] The busbars should be made of high conductivity electrical grade Aluminum (>60% IACS) 2] Purity of Aluminum conductor should not be less than 99.6% 3] Aluminum busbars should be Tin plated at the joint area to avoid oxidation 4] Where an earth conductor is required, it shall be possible to provide internal earth conductor of the same high conductivity material as the phase conductors and at least of 50% cross section of the phase conductor. Provision for mounting external earth strip to be provided on both side of busduct if required. 5] It should be possible to provide a 200% Neutral where specified in BOQ v] Insulation : 1] Each bus bar shall be individually insulated by means of Class-F Insulation, if it is multilayer insulation then each layer must have temperature withstand capacity of 155 deg C (Class-F) as well as breakdown voltage of minimum 6kV. 2] Mica insulation is not allowed which can’t be wrapped completely on conductor edges 3] The insulation should be UL certified 4] Insulation must be Halogen free & RoHS compliance vi] Housing : 1] The housing shall be made with 1.6mm thick electro-galvanized sheet steel of superior grade with Epoxy powder coating to withstand stringent site conditions; e.g. Humid, Costal, Acidic, etc 2] Enclosure must be dust & vermin proof and Provision for mounting external earth strip should be available on Busduct. |
127 | 3] IP rating of indoor busduct must be IP-54 / IP-55 & Outdoor busduct should be IP-65 / IP-66 plus canopy should be provided for protection of Busduct from direct sunlight & heavy rains. 4] Enclosure must be powder coated from both sides (internal & external) vii] Joints : 1] The joint design shall have inbuilt provision of absorbing expansion & contraction of 12mm per joint during operation. 2] The joint insulation must be of single piece molded design of thermoset material for longer life and higher temperature withstand & better insulation property. 3] The joint construction must allow +/- 3mm adjustment at the time of installation, for ease of adjusting to site measurement variations. 4] Stopper arrangement must be provided at every joint to prevent excessive insertion of conductors while jointing 5] The joint bolt must be insulated with a bolt insulator. The bolt insulator must be of molded one piece. 6] The joint design shall have inbuilt provision to prevent excessive insertion of busduct which can damage the bolt insulator. 7]The busbar ends shall not have holes or slots at the joints to avoid reduction in cross section area which will lead to temperature increase. The electrical continuity shall be through pressure plates, achieving a high contact area of joint cross section and expansion capability. 8] It shall be possible to install and remove the joints without disturbing the adjacent feeder section 9] Joint set should have insulators with temperature withstand capacity of class-F viii] Plug-in Unit / Tap off units : 1] Plug-in Units must be type tested design from NABL accredited laboratory for tests like, Thermal cycling test, |
128 | Temperature rise test, Short time withstand voltage, Mechanical operations, Impulse withstand voltage, Clearance & Creepage, Mechanical impact and ingress protection test 2] Plug-in unit must achieve IP-54 protection & IK10 mechanical impact 3] Plug-in Units must have interlocks with Busduct, door and MCCB for human safety 4] Busduct interlock – a) When the MCCB in the Plug-in unit is in ‘ON’ position, the operator should not be able to open the door. b) MCCB can’t be switched ON even when Plug-in Box is mounted on Busduct; it is possible only if interlock plate is engaged with feeder 5] Door interlock – a) Door can’t be opened when MCCB is ON b) MCCB can’t be switched ON until door is completely closed c) Door defeat feature should be available to use in case of emergency 6] The design of plug-in units shall be such that, the Earth conductor shall be of ‘First-Make’ ‘Last-Break ’type. 7] It should be possible to mount Plug-in Unit even when Busduct is in live condition but while insertion MCCB must be in OFF condition 8] The Plug-in unit will be suitable for accommodating MCCBs or other accessories, as required. The Plug-in unit should allow the flexibility of accommodating different reputed MCCB makes, to be mutually agreed depending on the tender requirements. 9] Plug-in Unit must be operated using side handle without MCCB ROM, and provision of Padlocking must be provided for human safety 10] Plug-in Unit must have Lifting provision for ease of handling and Guide pin for ease of installation 11] LED indicator must be provided on Plug-in Unit door which will glow once MCCB is switched ON |
129 | 12] Plug-in units should be plug-in type up to 400A & Bolt-on Type from 630A 13] It should be possible to offer Bolt-on Type Tap-off Box for 100A & higher ratings to withstand vibration due to crane movement, heavy machines in industries ix] Testing : 1] The busduct shall be type tested at a reputed test laboratory (certified by ASTA or ERDA) for the tests as per IEC-61439 Part-1 (Low voltage switchgear & controlgear assembly- General rules) & Part 6 (Bus bar trunking systems & bus ways) 2] Short circuit testing of busduct should be for duration of 1 Sec. Neutral & Earth conductor should also be tested for 60% short circuit rating of phase conductor 3] Degree of ingress protection (IP rating) shall also be tested at any reputed independent laboratory as per IEC-60529 4] Busduct tested for maximum severe Seismic condition of Zone-5 as per IS 1893-2002 and High Seismic Qualification Level as per IEEE 693-2005. Seismic testing done in severe most combination and orientation (Horizontal + Vertical installation along with Plug-in box in live condition) |
130 | A] Supply of 415V/690V/1000V Sandwich construction Busbar trunking system with Multilayer Class-F insulation and; Conductors : Aluminium Rating : 1250A Configuration : 3P4W IP Rating : IP54 Enclosure : GI 1.6mm thickness Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating |
131 | Straight Run Feeder IP54 |
132 | Flange End (fabrication cost only) |
133 | Horizontal Bend/Vertical Bend(fabrication cost only) |
134 | Reducer(fabrication cost only) 1250 to 1000 A |
135 | Plug-in Point(fabrication cost only) |
136 | Vertical Spring Hanger/Fix hanger (1 No per Floors per Riser) |
137 | Tinned Copper Braided Flexibles -360mm (with Hardware - Nuts and Bolts) |
138 | GI Earthing Strip - 25x3 (with Hardware - Nots and Bolts) |
139 | Shaft Cantiliver angle support with C Channel for Vertical spring or Rigid hangers |
140 | End feed Panel without switchgear (Suitable forACB) - Al Busbar Arrangement |
141 | Complete with Aluminium busbar or Cu Flexible with provision for rotary handle mechanism with bottom Cable entry and top Busduct outgoingprovision. 1250 Amp 4P 50kA MDO MTX 1.5G for EFU |
142 | B] Supply of 415V/690V/1000V Sandwich construction Busbar trunking system with Multilayer Class-F insulation and; Conductors : Aluminium Rating : 1000A Configuration : 3P4W IP Rating : IP54 Enclosure : GI 1.6mm thickness Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating |
143 | Straight Run Feeder IP54 |
144 | Plug-in Point(fabrication cost only) |
145 | Vertical Spring Hanger/Fix hanger (1 No per Floors per Riser) |
146 | Reducer(fabrication cost only) 1000 to 800 A |
147 | GI Earthing Strip - 25x3 ( with Hardware - Nots and Bolts ) |
148 | Shaft Cantiliver angle support with C Channel for Vertical spring or Rigid hangers |
149 | C] Supply of 415V/690V/1000V Sandwich construction Busbar trunking system with Multilayer Class-F insulation and; Conductors : Aluminium Rating : 800A Configuration : 3P4W IP Rating : IP54 Enclosure : GI 1.6mm thickness Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating |
150 | Straight Run Feeder IP54 |
151 | Plug-in Point(fabrication cost only) |
152 | Vertical Spring Hanger/Fix hanger (1 No per Floors per Riser) |
153 | End Cover |
154 | GI Earthing Strip - 25x3 ( with Hardware - Nots and Bolts ) |
155 | Shaft Cantiliver angle support with C Channel for Vertical spring or Rigid hangers |
156 | Plug-in Box 16A -100A with Mechanical Interlocking suitable for L&T MCCB but without Switchgear (standard size)(Tap off Box on Each Floor) |
157 | L&T Make 63 Amp 4P 50kA TM MCCB for PIB |
158 | TOOL KIT |
159 | Supply, installation, testing and commissioning of free-standing indoor semi-compartmentalised cubical type 120 kVAr APFC CAPACITOR BANK made out of 2.0 mm thick CRCA sheet and built upon rigid framework, having MPP type capacitor with 7% aluminium wound reactor units type tested in accordance with IS 16636 : 2017 with contactor switching, IP 4X protection and including air system provided by axial flow fan or centrifugal fan, control wiring with FR-LSH copper wires complete all as directed by engineer-in-charge Make : L & T, Schneider, Siemens, ABB |
160 | The APFC Capacitor Bank shall comprise of the follwing : (i) 250 A, 415 V, Ics = Icu = 36 kA, 50 Hz, TP MCCB with adjustable overload settings, adjustable short-circuit settings, adjustable earth - fault settings, current limiting type double break roto active type, instantaneous protection and microprocessor based trip unit - 01 Nos. (ii) High performance microprocessor based APFC relay with auto/ manual switch option - 01 Nos. (iii) 3-Phase power analyser with in-built digital VAF meter, phase indicating LED lamps (R, Y, B), step indicating LED lamps, ON /OFF push buttons, timer, CT - 500/5 A, Cl1.0, 15 VA - 01 Nos. (iv) MPP capacitor of 100 (3 X 10 + 1 X 20 + 1 X 50) kVAr (v) 10 kVAr - 04 STEPS (a) 40 A, 415, Ics = 100 % Icu = 36 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings - 03 Nos. (b) 3P, 10 kVAr power contactor, 415 V, 50 Hz 230 VAC coil - 04 Nos. (c) 7 % detuned reactor, 3-Ph, 10 kVAr, 440 V, 50 Hz - 04 Nos. (vi) 20 KVAr - 02 STEPS |
161 | (a) 50 A, 415, Ics = 100 % Icu + 36 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings - 01 Nos. (b) 3P, 20 kVAr power contactor, 415 V, 50 Hz 230 VAC coil - 01 Nos. (c) 7 % detuned reactor, 3- Ph, 20 kVAr, 440 V, 50 Hz - 01 Nos. (vi) 50 VAr - 01 STEPS (a) 100 A, 415, Ics = 100 % Icu = 36 kA, 50 Hz TP MCCB with fixed magnetic settings and adjustable thermal settings - 01 Nos. (b) 3P, 50 kVAr power contactor, 415 V, 50 Hz 230 VAC coil - 01 Nos. (c) 7% detuned reactor, 3-Ph, 50 kVAr, 440 V, 50 Hz - 01 Nos. NOTES : (i) The Panel shall be completely Ethernet communication ready to communicate with Energy Management System. (ii) The bidder shall furnish dimensional drawings of the items offered, indicating all the fittings, dimensional tolerances, typical GADs etc. with details of insulation at each point and core construction, etc. for approval of the Garrison Engineer. (iii) The bidder shall initiate the Garrison Engineer of the routine tests in accordance with IEC IS 16636 : 2017 in the OEM factory in presence of a representative nominated by the Garrison Engineer before dispatch. |
162 | EXTERNAL WATER SUPPLY WATER FEEDING LINE [From Fresh water Pump Room To Service Tank] |
163 | S & F GI C-class pipe with hot deep galvanised supprts, hot deep galvanised Nut- Bolts , PVC insulated U- Clamps,and all other necessary fittings and accessories also complete two coat of painting complete all as specified and directed by the engineer-in-charge. Make: Tata, Jindal, BST |
164 | a) 250 mm dia |
165 | b) 200 mm dia (For External Water Supply - 20, For Treated Water Supply - 10) |
166 | Supply,Installation,Testing, Commissioning end line strainerfor+ve suction of 250 mm dia complete all as specified and directed by engineer in charge. MAKE: Zoloto HSN code: 84818030 or equivalent |
167 | Supply,Installation,Testing and Commissioning of double flange Ball type NRV of 150 mm dia complete all as specified and directed by engineer in charge. MAKE: Zoloto HSN code:84813000 or equivalent |
168 | Supplying,Installing,Testing and Commissioning of cast iron double flange butterfly valve of approved make complete all as specified and directed by the engineer-in-charge. MAKE: Zoloto HSN code:84818030 or equivalent |
169 | a) 250 mm dia |
170 | b) 200 mm dia (For External Water Supply - 8, For Treated Water Supply - 1) |
171 | c) 100 mm dia |
172 | S & F of Fresh Water (Domestic Water) pump from UG tank to Service Floor tank, Multistage single outlet pump. Each pump shall have TEFC 2900 RPM three phase electric motor, cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. provided with mechanical seal, suitable for auto/ manual operation, with motors mounted on a single base frame, complete with all accessories, G.I. flanges, G.I. nut bolts, rubber gasket jointing,etc complete and as directed and of the 1310 lpm capacity , 198 mtr head, 105 HP/78 KW (1W +1S) a)Supplying, installing, commissioning ofDigital water level indicators for "the following including wall mounting stands, necessary fixing materials etc., complete. The quoted rate shall exclude the necessary AC and DC wiring. for all tanks b)DC cable with 25mm dia. GI conduit with necessary fixing material etc., complete for above level controllers. Make: PEW,Kirloskar, Mather & Platt, Crompton Greaves |
173 | S & F of Fresh Water (Domestic Water) pump from UG tank to Terrace floor tank (OHT), Multistage single outlet pump. Each pump shall have TEFC 2900 RPM three phase electric motor, cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. provided with mechanical seal, suitable for auto/ manual operation, with motors mounted on a single base frame, complete with all accessories, G.I. flanges, G.I. nut bolts, rubber gasket jointing,etc. complete all as specified and directed by engineer in chargeand of the 248 lpm capacity , 230 mtr head. 30 HP/22 KW(1W +1S) a)Supplying, installing, commissioning ofDigital water level indicators for "the following including wall mounting stands, necessary fixing materials etc., complete. The quoted rate shall exclude the necessary AC and DC wiring. for all tanks b)DC cable with 25mm dia. GI conduit with necessary fixing material etc., complete for above level controllers. Make: PEW,Kirloskar, Mather & Platt, Crompton Greaves |
174 | M & L for 1.1 kV grade 4.0 core 16 sqmm copper conductor, XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge. Make: POLYCAB /RR Kable/Havells or equivalent |
175 | Pump Panel-1 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, outdoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 630 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size NeutralAluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 25 KA for 1 sec. INCOMING a) 1 nos. 630 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 630/5 amps, Bar Primary, 10 VA Burden, CL 1 accuracy CTs . - 1 set, 0-500 Volt digital voltmeter with selector switch shall be |
176 | protected by 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING All Outgoing should be SCADA compatible. 1) 2 nos. -VFD starter with MCCB for 78 kW pump suitable for 415V, 50 Hz, A.C Supply with MCCB. Supply with 250 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. 2) 2 nos. -VFD starter with MCCB for 25 kW pump suitable for 415V, 50 Hz, A.C Supply with MCCB. Supply with 63 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. 3) 1 nos. -DOL starter with MCCB for 2 kW pump suitable for 415V, 50 Hz, A.C Supply with MCB. Supply with 32 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. The MCB shall be complete as per technical specifications. 4) 1 nos. -VFD starter with MCB suitable for 415V, 50 Hz, A.C Supply with MCB. Supply with 32 amps 4 pole MCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. The MCB shall be complete as per technical specifications. |
177 | Supply, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Pump and Valve Automation, Protection and communication Panel suitable for control and/or monitoring 08 nos. Pumps, 16 nos. Motorised Valves ( +02 Spare), 08 nos. Solenoid Valves, 08 nos, Pressure Transmitters, 04 nos. Ultrasonic Level Sensor, 32 nos. level switches.The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated with angle iron supports not less than 40x40x5mm. .The Panel should comprise the following items: (a) Water Level Sensing & Display (b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention (h) Manual Mode Operation (all connected sub systems including all valves (in pump houses and connected buildings / overhead tanks) and pumps from the PLC based Control Panel. The PLC based Panel shall consist of the following sub systems (i) 02 Nos. Current transducers / energy meters with inbuilt mod bus communication port (Make: RISHABH/CONZERVE/ADEPT/L&T) (ii) 01 No.PLC with following specifications; a).Suitable .Digital inputs/ outputs and analog inputs b). 4 serial ports supporting open communication protocol, 01 No. Ethernet port c). Programming software based on IEC to facilitate building of custom built function blocks d). Expandable up to 192 DI / DOs |
178 | (iii) 01 No. HMI - 7" (min) Graphical Touch screen multicolor having following minimum features a).02 Nos. serial ports and 01 No. USB port b). Floating Point support c). Built in RTC d) Bar Graph and image (bmp, jpeg files) e). Real-time and historical Trending). Real time and historical alarms, (iv) 01 No. SMPS of 5 A rating (Make: TELEMECANIQUE / NHP) (v) Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating (Make: OEN / OMRON / IDEC / ALLEN BRADLEY) (vi) MCB of rating 10A (Make: Havells/ Schneider) (vii) Single Phase Preventer (Make: MINILEC) (viii) Illuminated Push Buttons, Push Buttons and Indicator Lamps as per requirement (Make: SCHNEIDER / ESBEE) (ix) Selector Switches as per requirement (Make: SCHNEIDER / ESBEE) (x) Audio Visual Alarm Indicator (Make: MIMIC / ESBEE / SCHNEIDER) (xi) OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, GPRS modem based communication module for standby with suitable antenna, modem controller and data enabled SIM card. Cost of communication from the date of completion. The quoted cost shall deem to include the cost of communication for 12 months from the date of completion. Location: To be installed at Locations: G 65 1. Fresh Water PH 2. Raw Water PH Make of Control Panel: Recktronic Devices and Systems |
179 | Up gradation of the existing software to incorporate management and control of New Pump House including develop and add the additional features as described below the Linking of the Automated Pump houses to Master Control Station by altering the existingsoftware Integration of Existing SCADA System 1. SCADA Configuration: Addition of required OPC Server tags, SCADA Tags, Data log Module, App Module and Reporting & SMS Utility 2. Development: SCADA Screens for new Updated Panel configuration, Layout for App new Updated Panel configuration, Report Format new UpdatedPanel configuration, 3. Integration of OPC Sever with SCADA: Tags binding – OPC to SCADA, SCADA to Screen Objects, Data log module, SCADA to App SCADA to Reporting Software, SCADA to SMS Utility Software 4. On-site development: Modifications in SCADA Screens, Modifications in reporting format, Modifications in App layout and HTML utility to incorporate all sub systems of the new pump house as per ground requirement without affecting the existing system. The work is to be carried out by authorised representative ofthe OEM if various software / or through any agency certified by the OEM. |
180 | Supply, Installation Testing & Commissioning of pressure Transmitter with following specification including necessary powerpack for supply of DC :Power supply: 10-36 V DCProcess connection: G ½ “Enclosure: whether proof IP 65Process temperature: -30 to 120 CelsiusAccuracy: 0.25 % complete all as specified and directed by engineer in charge. (For External Water Supply - 4, For Treated Water Supply - 4) Make: Danfoss / Siemens / E & H |
181 | Supply, Installation Testing & Commissioning of direct acting type release solenoid valve for air release during priming; with followingspecifications : Size: 10 mm/15mm Pressure rating: 10 kg / sq. cm. Type: Normally closed (For External Water Supply - 4, For Treated Water Supply - 4) Make: AVCON/ ROTEX/ ASCO/JOHNSON CONTROL/ RITETORK |
182 | Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve consisting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 150 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure.Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq. cm.Operating Angle: 90 degreesDisc Material: CI with nylon coatingLimit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memoryIn built SD CardSpace Heater In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data. Mounting :Direct on valve Make:RITETORK |
183 | Supply, Installation, Testing and Commissioning of Float type PointLevel Sensor with the following specifications; Type: Magnetic Magnet: Ring type Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon (For External Water Supply - 16, For Treated Water Supply - 16) Make: RECKTRONIC DEVICES AND SYSTEMS |
184 | Supply, Installing, Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 meters Accuracy : 0.5 % minimum Supply Voltage : 24V dc Output : 4-20 mA Ultrasonic Frequency:75 kHz burst, rep. rate 96 ms Delay at Power-up: 1.5 seconds Temperature Effect: Uncompensated: 0.2% of distance/°C &Compensated: 0.02% of distance/°C Delay at Power-up: 1.5 seconds Resolution: 1.0 mm Output Response Time: 100 ms to 2300 ms Minimum Window Size: 20 mm Environmental Rating: Leak proof design is rated IEC IP67; NEMA 6P Operating Conditions: Temperature: –20 °C to 70 °C (–4 °F to 158 °F) Maximum relative humidity: 100%IndicatorsGreen Power On LED: Indicates power is ONRed Signal LED: Indicates target is within sensing range, and thecondition of the received signalTeach/Output indicator (bicolor Amber/Red): Amber – Target is within taught limits; Flashing Amber – Target is outside taught window Limits; Red – Sensor is in TEACH mode (For External Water Supply - 3, For Treated Water Supply - 2) Makes: Endress+Hauser / Banner / Krohne Marshal / Siemens |
185 | Supply & Fixing 2 x 1.5 sq. mm PVC sheathed and PVC insulated, armored, FRLS, Copper cable multistranded complete all as specified and directed by engineer in charge. (For External Water Supply - 200, For Treated Water Supply - 200) Make: POLYCAB/FINOLEX/RR CABLE |
186 | Supply & Fixing 4 x 1.5 sq. mm PVC sheathed and PVC insulated, armored, FRLS, Copper cable multistranded complete all as specified and directed by engineer in charge. (For External Water Supply - 350, For Treated Water Supply - 350) Make: POLYCAB/FINOLEX/RR CABLE |
187 | Supply & Fixing 6 x 1.5 sq. mm PVC sheathed and PVC insulated, armored, FRLS, Copper cable multistranded complete all as specified and directed by engineer in charge. (For External Water Supply - 1100, For Treated Water Supply - 1100) Make: POLYCAB/FINOLEX/RR CABLE |
188 | Supply & Fixing 5 pair 0.5 sq. mm PVC sheathed and PVC insulated, armored, FRLS, Copper cable multistranded complete all as specified and directed by engineer in charge. (For External Water Supply - 1850, For Treated Water Supply - 1850) Make: POLYCAB/FINOLEX/RR CABLE |
189 | Supply, Installation, Testing and Commissioning of outdoor type Wimax CPE stations operating on license free frequency of 5 Ghz at suitable locations along with suitable antenna complete with mounting pole and accessories to be connected to the OFc network of each node and establish wireless connectivity with the central server complete all as specified and directed by engineer in charge. Make: Siemens, Ubiquiti |
190 | TREATED WATER SUPPLY WATER FEEDING LINE [From Treated water Pump Room To Service Tank] |
191 | Supply,Installation,Testing, Commissioning end line strainerfor+ve suction of 200 mm dia complete all as specified and directed by engineer in charge. MAKE: Zoloto HSN code: 84818030 or equivalent |
192 | Supplying,Installing,Testing and Commissioning of cast iron double flange butterfly valve of approved make complete all as specified and directed by the engineer-in-charge. Make: Zoloto HSN code:84818030 or equivalent |
193 | a) 150 mm dia |
194 | b) 80 mm dia |
195 | Supply,Installation,Testing and Commissioning of double flange Ball type NRV of 100 mm dia complete all as specified and directed by engineer in charge. MAKE: Zoloto HSN code:84813000 or equivalent |
196 | S & F of Treated Water (Flushing Water) pump from UG tank to Service Floor tank, Multistage single outlet pump.. Each pump shall have TEFC 2900 RPM three phase electric motor, cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. provided with mechanical seal, suitable for auto/ manual operation, with motors mounted on a single base frame, complete with all accessories, G.I. flanges, G.I. nut bolts, rubber gasket jointing,etc complete and as directed and of the 347 lpm capacity , 198 mtr head, 28 HP/21 KW (1W +1S) a)Supplying, installing, commissioning ofDigital water level indicators for "the following including wall mounting stands, necessary fixing materials etc., complete. The quoted rate shall exclude the necessary AC and DC wiring. for all tanks b)DC cable with 25mm dia. GI conduit with necessary fixing material etc., complete for above level controllers. Make: PEW,Kirloskar, Mather & Platt, Crompton Greaves |
197 | S & F of Treated Water (Flushing Water)pump from UG tank to Terrace floor tank (OHT), Multistage single outlet pump. Each pump shall have TEFC 2900 RPM three phase electric motor, cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. provided with mechanical seal, suitable for auto/ manual operation, with motors mounted on a single base frame, complete with all accessories, G.I. flanges, G.I. nut bolts, rubber gasket jointing,etc complete and as directed and of the 66 lpm capacity ,230 mtr head. 12.5 HP/9.3 KW(1W +1S) a)Supplying, installing, commissioning ofDigital water level indicators for "the following including wall mounting stands, necessary fixing materials etc., complete. The quoted rate shall exclude the necessary AC and DC wiring. for all tanks b)DC cable with 25mm dia. GI conduit with necessary fixing material etc., complete for above level controllers. Make: PEW,Kirloskar, Mather & Platt, Crompton Greaves |
198 | Pump Panel-2 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, outdoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 150 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 25 KA for 1 sec. INCOMING a) 1 nos. 150 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 150/5 amps, Bar Primary, 10 VA Burden, CL 1 accuracy CTs . - 1 set, 0-500 Volt digital voltmeter with selector switch shall be |
199 | protected by 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING All Outgoing should be SCADA compatible. 1) 2 nos. -VFD starter with MCCB for 21 kW pump suitable for 415V, 50 Hz, A.C Supply with MCCB. Supply with 63 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications.. 2)2 nos. -VFD starter with MCB for 6 kW pump suitable for 415V, 50 Hz, A.C Supply with MCB. Supply with 40 amps 4 pole MCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. The MCB shall be complete as per technical specifications. 3) 1 nos. -VFD starter with MCB suitable for 415V, 50 Hz, A.C Supply with MCB. Supply with 32 amps 4 pole MCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 10 KA. The MCB shall be complete as per technical specifications. |
200 | M & L for 1.1 kV grade 4.0 core 10 sqmm copper conductor, XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge. Make: POLYCAB /RR Kable/Havells or equivalent |
201 | Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve consisting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 100 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure.Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq. cm.Operating Angle: 90 degreesDisc Material: CI with nylon coatingLimit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memoryIn built SD CardSpace Heater In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data. Mounting :Direct on valve Make:RITETORK |
202 | Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve consisting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 65 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure.Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq. cm.Operating Angle: 90 degreesDisc Material: CI with nylon coatingLimit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memoryIn built SD CardSpace Heater In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data. Mounting :Direct on valve Make:RITETORK |
203 | FIRE FIGHTING |
204 | HYDRANT SYSTEM |
205 | Supplying,Installing,Testing and Commissioning of cast iron double flange butterfly valve of approved make complete as specified and directed by the engineer-in-charge. MAKE: Zoloto HSN code:84818030 or equivalent |
206 | 250 mm dia |
207 | 200 mm dia |
208 | 150 mm dia |
209 | 100 mm dia |
210 | 80 mm dia |
211 | 50 mm dia |
212 | Supply,Installation,Testing and Commissioning of double flange Ball type NRV complete as specified and directed by the engineer-in-charge. MAKE: Zoloto HSN code:84813000 or equivalent |
213 | 200 mm dia |
214 | 150 mm dia |
215 | 100 mm dia |
216 | 80 mm dia |
217 | M & L for PN 16 rated CI "Y" -type strainer for suction conforming to IS: 907- 1984 with SS filter screen and flange drilling standard end connection conforming to IS: 1538- 1993 and necessary accessories for suction side of fire pumps all complete as specified and directed by the engineer-in-charge. MAKE: Zoloto HSN code: 84818030 or equivalent |
218 | 250 mm dia |
219 | 100 mm dia |
220 | 80 mm dia |
221 | S&F 100mm Dia Bronze Compact Pressure Reducing Valve (Screwed) complete all as specified and directed by the engineer-in-charge. MAKE: Zoloto HSN code: 84811000 or equivalent |
222 | S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed by the engineer-in-charge. Make: Newage, AAAG, Minimax |
223 | Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 complete all as specified and directed by the engineer-in-charge. |
224 | Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete all as specified and directed by the engineer-in-charge. (For Hydrant System - 6, For Sprinkler System - 3) |
225 | M & L for 1.1 kV grade aluminium conductor, XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge. |
226 | 4CX16 SQ.MM. CU ARM.XLPE CABLE |
227 | 4CX10 SQ.MM. CU ARM.XLPE CABLE |
228 | SPRINKLER SYSTEM |
229 | Supplying,Installing,Testing and Commissioning of cast iron double flange butterfly valve of approved make complete all as specified and directed by the engineer-in-charge. MAKE: Zoloto HSN code:84818030 or equivalent |
230 | 100 mm dia |
231 | 150 mm dia |
232 | FIRE PUMPS |
233 | I. Ground Floor Pumps a. High pressure zone Pumps |
234 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of fire service main Fire multistage Single outlet pump, of 2850 LPM (Litres/min.) at 220m head centrifugal type, 250 HP,(187 kW) or of suitable HP,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal and the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. (Fire Hydrant- 01, Fire Sprinkler- 01) NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
235 | BLANK |
236 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of Jockey multistage Single outletpump for of 180 LPM at 220m head, 3 ph. 415 A.C. 16 HP, (12 kW) or of suitable HP with suitable Stages ,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal ,the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. (Fire Hydrant- 01, Fire Sprinkler- 01) NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
237 | BLANK |
238 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of Radiator cooled 4 stroke, engine speed of 1500 RPM, Diesel engine driven pumping set of horizontal, centrifugal, single stage fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 220m the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
239 | b. Low pressure zone Pumps |
240 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of fire service main multistage Single outlet pump, of 2850 LPM (Litres/min.) at 135m head centrifugal type, 155 HP,(115 kW) or of suitable HP,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal and the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. (Fire Hydrant- 01, Fire Sprinkler- 01) NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
241 | BLANK |
242 | Supply, Installation, Testing, pperfect aligning and proper leveling andcommissioning of Jockey multistage Single outletpump for of 180 LPM at 135m head, 3 ph. 415 A.C. 9 HP, (7 kW) or of suitable HP with suitable Stages ,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal ,the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. (Fire Hydrant- 01, Fire Sprinkler- 01) NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
243 | BLANK |
244 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of Radiator cooled 4 stroke, engine speed of 1500 RPM, Diesel engine driven pumping set of horizontal, centrifugal, single stage fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 135m. the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
245 | Supply, Installation, Testing & Commissioning of Non-clog wet pit submersible pump with motor having 200 LPM capcity @ 2.0 kg/cm2 total discharge pressure. (1W +1S) and automatic float control arragement complete with delievry gate & check valve,control panel,anti vibrator etc. complete all as specified and directed by engineer-in-charge. (Pump room sump pump-Dewatering pump) Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
246 | II. Service Floor Pumps |
247 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of fire service main multistage Single Outlet pump, of 2850 LPM (Litres/min.) at 76m head centrifugal type, 87 HP,(65 kW) or of suitable HP,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal and the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. (Fire Hydrant- 01, Fire Sprinkler- 01) NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
248 | BLANK |
249 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of Jockey multistage Single outlet pump for of 180 LPM at 76m head, 3 ph. 415 A.C. 7 HP, (5 kW) or of suitable HP with suitable Stages ,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal ,the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. (Fire Hydrant- 01, Fire Sprinkler- 01) NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
250 | BLANK |
251 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of fire service Standby electrical multistageSingle Outlet pump, of 2850 LPM (Litres/min.) at 76m head centrifugal type,87 HP,(65 kW) or of suitable HP,the pump shall be of cast iron construction with bronze impeller, stainless steel shaft, flexible coupling and gland packing seal and the complete unit shall be mounted on a common structural steel base frame and shall include accessories such as foundation bolts, casing relief valve, pressure relief valve, Suitable cement concrete foundation duly plastered with anti vibration pads etc complete with all accessories as specified and directed by engineer-in-charge. NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
252 | Supply, Installation, Testing, perfect aligning and proper leveling andcommissioning of electrical motor driven Booster Pump, monoblock type of capacity 900 LPM at 35 MWC. The pump shall be coupled to TEFC motor of suitable HP with speed of 2900RPM and complete set shall be mounted on common base frame,the rate shall be inclusive of foundation bolts and all other necessary accessories, complete in all respects as specified and directed by engineer-in-charge. NOTES: [i] The pump shall be capable of furnishing not less than 150% rated capacity at a head of not less than 65% of the rated head. [ii] The shut-off head shall not exceed 120% of rated head. [iii] The coupling guard shall be of zero access type. [iv] The quoted rate shall include providing and fixing of vibration pad, common base plate, foundation bolts, grouting etc. Make: PEW, Kirloskar, Mather & Platt, Crompton Greaves |
253 | CONTROL PANEL FOR FIRE PUMPS |
254 | Fire Pump Panel-1 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 75 mm x 75 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 1250 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) bus bars with colour coded heat shrink sleeves supported on SMC type grip supports, 50 KA for 1 sec. INCOMING a) 1 no. 1250 A, 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 1250/5 amps, 5 VA Burden, CL 1 accuracy CTs. - 1 set, 0-500 Volt digital voltmeter with selector switch shall be protected by |
255 | 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING All Outgoing should be SCADA compatible. High pressure zone pump set 1) 2 No. - 630 amps TPN MCCB with250 HP VFD starter and outgoing feeders to Main Fire pump motor. The compartment shall contain Overload and Dry run protection, control wiring for pressure switch, CT operated digital electronic ammeter of 0-160. amps range with Auto / Manual selector switch andindicating lamp with MCBs for `ON"/OFF/TRIP" status of motor. 2) 3 No.- 63 amps TPN MCCB with 16 HP VFD starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall have directly operated digital electronic ammeter of 0-100. amps and indicating lamps with MCBs for `ON"/OFF/TRIP" status of pump motors. Low pressure zone pump set 3) 2 No. - 400 amps TPN MCCB with155 HP VFD starter and outgoing feeders to Main Fire pump motor. The compartment shall contain Overload and Dry run protection, control wiring for pressure switch, CT operated digital electronic ammeter of 0-160. amps range with Auto / Manual selector switch andindicating lamp with MCBs for `ON"/OFF/TRIP" status of motor. 4) 3 No.- 63 amps TPN MCCB with 10 HP VFD starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall have directly operated digital electronic ammeter of 0-100. amps and indicating lamps with MCBs for `ON"/OFF/TRIP" status of pump motors. 5) Panels shall have sufficient (min. 20 Nos) NO/NC contacts for extending the status (annunciation) of fire pumps to the Fire alarm panel. |
256 | 6) Control Panel for Diesel Engine Main Pump - 1 No. Auto Battery charger with transformer with rectifier resistance DC ammeter, DC Voltmeter, tickle / booster / off selection switches - 1 No. 7) 1 set of indicating lamps for - phase indication, battery charger on, Feeder for Diesel Engine Pump, over load relay, DC supply on, control switch on, Engine fails to start, Pump on, Low oil pressure, High water temperature, Auto manual selector switch. 8) 1 sets of push button stations for - Engine Start, Engine Stop, Engine - hooter ACK, Engine - fault reset, Selector switches (Engine control, mode selector)-1 No., Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set., 9) Hooter for audio alarm (Industrial type) - 1 No. 10) Panels shall have sufficient (min. 20 Nos) NO/NC contacts for extending the status (annunciation) of fire pumps to the Fire alarm panel. Note: Item includes incorporation of wiring between pressure switch,pressure gauge & pumps.Necessary automation has to be done for sequencial operation of Fire fighting pumps based on Firefighting standard practices using control cable of suitable size & logic. Any items which is essential & not mentioned in the description shall be provided by the contractor & no extra cost for the same shall be claimed on this account. |
257 | Fire Pump Panel-2 Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 75 mm x75 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed BUSBAR CHAMBER 400 Amps uniformly rated, continuous duty,415VAC,3Phaseandfull size Neutral Aluminium (Throughout the length) bus bars with colour coded heat shrink sleeves supported on SMC type grip supports, 50 KA for 1 sec. INCOMING a) 1 nos. 400 amps 4 pole MCCB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 25 KA. The MCCB shall be complete as per technical specifications. b) Three nos. phase indicating light through protected by 2 amps MCB’s.- 1 set, Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 400/5 amps, 5 VA Burden, CL 1 accuracy CTs. - 1 set, 0-500 Volt digital voltmeter with selector switch shall be protected by |
258 | 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. OUTGOING All Outgoing should be SCADA compatible. 1) 3 No. - 200 amps TPN MCCB with87 HP VFD starter and outgoing feeders to Main Fire pump motor. The compartment shall contain Overload and Dry run protection, control wiring for pressure switch, CT operated digital electronic ammeter of 0-160. amps range with Auto / Manual selector switch andindicating lamp with MCBs for `ON"/OFF/TRIP" status of motor. 2) 2 No.- 63 amps TPN MCCB with 7 HP VFD starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall have directly operated digital electronic ammeter of 0-100. amps and indicating lamps with MCBs for `ON"/OFF/TRIP" status of pump motors. 3) 2 No.- 63 amps TPNMCCB with 12 HP VFD starter with single phase preventer and outgoing feeder to Booster pump motor. The compartment shall have directly operated digital electronic ammeter of 0-100. amps and indicating lamps with MCBs for `ON"/OFF/TRIP" status of pump motors 4) Control Panel for Diesel Engine Main Pump - 1 No. Auto Battery charger with transformer with rectifier resistance DC ammeter, DC Voltmeter, tickle / booster / off selection switches - 1 No. 5) 1 set of indicating lamps for - phase indication, battery charger on, Feeder for Diesel Engine Pump, over load relay, DC supply on, control switch on, Engine fails to start, Pump on, Low oil pressure, High water temperature, Auto manual selector switch. |
259 | 6) 1 sets of push button stations for - Engine Start, Engine Stop, Engine - hooter ACK, Engine - fault reset, Selector switches (Engine control, mode selector)-1 No., Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set., 7) Hooter for audio alarm (Industrial type) - 1 No. 8) Panels shall have sufficient (min. 20 Nos) NO/NC contacts for extending the status (annunciation) of fire pumps to the Fire alarm panel. Note: Item includes incorporation of wiring between pressure switch,pressure gauge & pumps.Necessary automation has to be done for sequencial operation of Fire fighting pumps based on Firefighting standard practices using control cable of suitable size & logic. Any items which is essential & not mentioned in the description shall be provided by the contractor & no extra cost for the same shall be claimed on this account. |
260 | Supply, installation, testing and commissioning of Emergency Start / Stop Push Button station weather proof type for Booster pump at terrace level including earthing with 12 HP Star-Delta starter complete all as specified and directed by the engineer-in-charge. |
261 | FIRE ALARM & PUBLIC ADDRESS FAVA SYSTEM |
262 | Supply, installation, testing & commissioning of Microprocessor based 10-loop panel, True Peer-to-Peer Networkable Addressable Integrated Main Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel shall havedegrade mode. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network andFire Fighters Telephone TWO way Communication System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of fire alarm CPU shall not result in failure of voice alarm controller complete all as specified and directed by the engineer-in-charge. Note: The fire alarm panel shall be servicable by any system integrator Approvals : UL listed & FM Approved Make: Notifier/XLS-3000/IFC-JC |
263 | Supply, installation, testing & commissioning of Microprocessor based 10-loop panel, True Peer-to-Peer Networkable Addressable Sub Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel shall havedegrade mode. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition complete all as specified and directed by the engineer-in-charge. Note: The fire alarm panel shall be servicable by any system integrator Approvals : UL listed & FM Approved Make: Notifier/XLS-3000/IFC-JC |
264 | Supply, installation, testing & commissioning of Netwrok Repeater Panel with minimum 8 inch touch screen display with control keypad complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
265 | Supply, installation, testing & commissioning of Gas leak Detector in Kitchen with necessary power supply complete all as specified and directed by the engineer-in-charge. Make: Honeywell/True Safe |
266 | Supply, installation, testing & commissioning of Addressable Relay Module for Third Party Outputs. The relay module shall provide DPDTcontact rated at 24V DC, 2A at resistive load. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
267 | Supply, installation, testing & commissioning of Addressable Monitor Module for Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
268 | Supply, installation, testing & commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
269 | Supply, installation, testing & commissioning of 24VDC power supply unit for sounder cum strobes. The unit shall have in built battery charger & sufficient back of 24 hours in stand by & 30 mins in alarm condition. The power supply unit shall be monitored by fire alarm panel complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
270 | Supply, installation, testing & commissioning of Addressable Fire Fighter"s Telephone Jack with suitable interface module for two way communication between Remote Fire Fighter & Fire Command Center complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
271 | Supply, installation, testing & commissioning of Fire Fighter"s Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC |
272 | Supply, installation 2 cores 1.5 sq mm 1100 Volt Flexible ABC Conductor, PVC Type D Insulated, Cores laid up, Overall Shielded by Al-mylar along with ATC drain wire & Overall PVC Type ST-3 Sheathed Cable Generally confirming to IS 694:2010 complete all as specified and directed by the engineer-in-charge. Make: Finolexr/Polycab/RR-Kabel/Havells |
273 | VOICE ALARM SYSTEMEQUIPMENT |
274 | Supply, installation, testing & commissioning of UL Listed Digital Audio Amplifier capable of processing of 8 class B speaker line output and total of 300 W at 70.7 VRMS output along withnecessaryenclosures.TheDigital Audio Amplifiershallbefully monitored for fault and alarmreporting complete all as specified and directed by the engineer-in-charge. "In case of fire a pre-recorded shall be broadcast on affected floor, one floor below & two floors above the affected floor" Make: Notifier/XLS-3000/IFC-JC |
275 | Supply, installation, testing & commissioning of 240W power Amplifier for high power speakers. The suffient size of PA rack shall be considered to mount power amplifiers complete all as specified and directed by the engineer-in-charge. Make: Notifier/XLS-3000/IFC-JC/Honeywell |
276 | Supply,Installation,Testing and Commissioning of UL Listed 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of same make as that of theControl Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms complete all as specified and directed by engineer-in-charge. Makes: Notifier/XLS-3000/IFC-JC |
277 | Supply,Installation,Testing and Commissioning of 10W Multi-Tap (5W; 10W), Wall Mount speakers. The speaker shall be compatible with supplied Amplifiers and shall work on 70.7Vrms complete all as specified and directed by engineer-in-charge. Makes: Notifier/XLS-3000/IFC-JC/Honeywell |
278 | S & F PA Rack for Power Amplifiers complete all as specified and directed by the engineer-in-charge. Note: Contractor shall furnish the size of rack as per amplifier qty. Make: Walrack/Rittal |
279 | Supply, installation 1100 Volt Flexible ABC Conductor, PVC Type D Insulated, Cores laid up, Overall Shielded by Al-mylar along with ATC drain wire & Overall PVC Type ST-3 Sheathed Cable Generally confirming to IS 694:2010 complete all as specified and directed by the engineer-in-charge. Make: Finolexr/Polycab/RR-Kabel/Havells |
280 | PRESSURIZATION SYSTEM |
281 | 1. Pump Room Ventilation |
282 | Supply, fabrication, installation and testing of Axial Flow fans with properly supported on MS structure necessary spring isolators with squirrel cage TEFC, 415± 10% volts, 50 cycles, 3 phase AC power supply, IP55, S1 duty, IS325, class F insulation direct driven motor, Fans shall be safely stored an made lifting, shifting, assembly, making necessary arrangement for mounting. Star delta starter panel with on off push button, on/off/trip indicators, manual reset overload relays, armoured cabling with proper tray supports from starter panel to fan motor Starter panel should be provided with auto manual toggle switch & facility to operate on remote signal. Necessary earthing, smoke & fire detector providing signal to starter panel, related control cabling shall be part of starter panel as approved by consultants & clients and complete all as specified and directed by the engineer-in-charge. |
283 | a. Fresh Air Fan 7500 CFM @ 40 MMWG |
284 | b. Exhaust Air Fan 10000 CFM @ 40 MMWG |
285 | Supply,installation and testing of GI Ducting complete all as specified and directed by the engineer-in-charge. |
286 | a. 22 Gauge (For Pump Room Ventilation - 200, For Staircase Pressurization - 800, For Liftwell Pressurization - 300) |
287 | b. 24 Gauge (For Pump Room Ventilation - 150, For Staircase Pressurization - 400, For Liftwell Pressurization - 150) |
288 | Supply, fabrication, installation and testing the flexible connections constructed of fire resistant resin doublesleeveasperthe approved shop drawings complete all as specified and directed by the engineer-in-charge. (For Pump Room Ventilation - 4, For Staircase Pressurization - 8, For Liftwell Pressurization - 6) |
289 | Supply, Fabrication and Installation of GI Birdscreen at Fan Inlet as per approved drawing complete all as specified and directed by the engineer-in-charge. (For Pump Room Ventilation - 2, For Staircase Pressurization - 8, For Liftwell Pressurization - 6) |
290 | Supply and Installation of powder coated grill with damper as per approved drawing complete all as specified and directed by the engineer-in-charge. (For Pump Room Ventilation - 4.5, For Staircase Pressurization - 12, For Liftwell Pressurization - 3) |
291 | Supply, fabrication, installation and testing of Starter Panel for the above Fan complete all as specified and directed by the engineer-in-charge. |
292 | Supply, fabrication, installation and testing of Isolator Box near Fan complete all as specified and directed by the engineer-in-charge. |
293 | Supply, fabrication, installation and testing of Electrical Power Cable for Fan,3C x 4 Sq mm Copper Armoured Cable complete all as specified and directed by the engineer-in-charge. (For Pump Room Ventilation - 120, For Staircase Pressurization - 450, For Liftwell Pressurization - 325) |
294 | M & L for MS Fabrication Work for Fan and Duct support complete all as specified and directed by the engineer-in-charge. (For Pump Room Ventilation - 350, For Staircase Pressurization - 4500, For Liftwell Pressurization - 4500) |
295 | 2. Staircase Pressurization |
296 | Supply, fabrication, installation and testing of Axial Flow fans with properly supported on MS structure necessary spring isolators with squirrel cage TEFC, 415± 10% volts, 50 cycles, 3 phase AC power supply, IP55, S1 duty, IS325, class F insulation direct driven motor, Fans shall be safely stored an made lifting, shifting, assembly, making necessary arrangement for mounting. Star delta starter panel with on off push button, on/off/trip indicators, manual reset overload relays, armoured cabling with proper tray supports from starter panel to fan motor Starter panel should be provided with auto manual toggle switch & facility to operate on remote signal. Necessary earthing, smoke & fire detector providing signal to starter panel, related control cabling shall be part of starter panel as approved by consultants & clients and complete all as specified and directed by the engineer-in-charge. |
297 | a. 13400 CFM @ 50 MMWG |
298 | b. 10700 CFM @ 50 MMWG |
299 | Supply, fabrication, installation and testing of Starter Panel for the above Fan complete all as specified and directed by the engineer-in-charge. |
300 | Supply, fabrication, installation and testing of Isolator Box near Fan complete all as specified and directed by the engineer-in-charge. |
301 | 3. Liftwell Pressurization |
302 | Supply, fabrication, installation and testing of Axial Flow fans of 17000 CFM @ 50 MMWG with properly supported on MS structure necessary spring isolators with squirrel cage TEFC, 415± 10% volts, 50 cycles, 3 phase AC power supply, IP55, S1 duty, IS325, class F insulation direct driven motor, Fans shall be safely stored an made lifting, shifting, assembly, making necessary arrangement for mounting. Star delta starter panel with on off push button, on/off/trip indicators, manual reset overload relays, armoured cabling with proper tray supports from starter panel to fan motor Starter panel should be provided with auto manual toggle switch & facility to operate on remote signal. Necessary earthing, smoke & fire detector providing signal to starter panel, related control cabling shall be part of starter panel as approved by consultants & clients and complete all as specified and directed by the engineer-in-charge. |
303 | Supply, fabrication, installation and testing of Starter Panel for the above Fan complete all as specified and directed by the engineer-in-charge. |
304 | Supply, fabrication, installation and testing of Isolator Box near Fan complete all as specified and directed by the engineer-in-charge. |
305 | LIFTS |
306 | Design, Fabrication, Supply, Installation, Testing & Commissioning of following Electric Traction Type fully automatic Machine room Elevator with Closed loop AC variable voltage & variable frequency drive unit suitable for operation on 415V, 3 Phase, 50 Hz. AC supply, having speed of 5.0 m/sec., power operated centre opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom suitable for hook up to building EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fire man"s switch at Main Landing floor and secondary recall floor, digital car position indicator in car, Hall lanterns with Up & Down indication at all floors,light fixtures, ventilation fan, landing sill, main beam in Machine Room for machine mounting, pit ladder etc. complete with all accessories and with Automatic Rescue Device (ARD) complete with dry maintenance free sealed batteries as required etc.,and as under: - Elevator No. : A to F (1 to 6) Capacity - 20 passengers (1360 Kgs) Speed - 5.0 mps Rise - 199.20 m (Approx.) No. of stops - 63 No. of regular openings - 62 (Floor - G,1~54,56~62) No. of controlled openings - 1 (Floor - 55) Shaft size - 2400 mm x 2700 mm (W x D) Car size - As per IS/NBC (Tentative Car size: 1700 mm W x 1800 mm D) Car Interior - Stainless Steel Hairline Finish (Grade 304) with minimum panel thickness of 1.5 mm Pit depth - 5500mm (Approx.) |
307 | Overhead - 8600mm (Approx.) Door Size: 1000 mm (Wide) x 2400 mm (High) Car Doors: Automatic Power operated, 2-Panel centre opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness -1.5 mm Landing doors : 2-Panel centre opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness - 1.5 mm Operation - Full Destination Control System with / without attendant, group operation controlfor Six (06) lifts. ARD for emergency operation Hall Lanterns with Gong for all landings in Lobby Car Position indicator over Car door / at a suitable height on Front return panel Destination Control Keypad (Input terminals) - 04 on All floors Hidden Car operating panel for Fire Emergency and Attendant Operation 25 mm Recess for Flooring by Others and Floor weight provision Registered Call Display indicators on Car Door Columns 3-Way Built-in Intercom Facility suitable to hook up with building EPABX Software integration (with BMS & FAS System) Handrails on all sides Ceiling interior and light fixture shall be in scope of vendor Multibeam Full height Infra Red protection for Door Opening & Closing On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator. |
308 | Controller: Closed Loop A.C. variable voltage & variable frequency with harmonic arrestors to limit Total Harmonic Distortion below 5% Power- 415 V, 3 phase, 50 Hz, 4 wires system. Narrow Door frames of same finish as Landing doors on each landing Should have regenerative drives to save electricity Note: Additional load of 300kg shall be considered for Interior Designing. Operation / Grouping: Destination Control System (Full) Other General Requirements Battery operated Emergency Light, Fan and Alarm Bell Audio & Visual Indication inside Car for Overload, ARD operation and Fireman operation Fireman Switch in Ground Floor and Secondary Recall Floor Automatic rescue device suitable to operate for minimum 03 times without recharging (Access Hatch on Car top and False ceiling to be consider for each lift for emergency rescue) All Landing doors to have 01 Hour Fire resistance rating. Oil buffers, Adjustable Roller guides, Cast Iron Filler weights for Counterweight, Solid "T" Section machined Guide rails for Car & Counterweight Ascending Car Overspeed protection (ACOP) and Uncontrolled Car movement protection (UCMP) Earthquake operation with Primary and Secondary wave seismic sensors Retainers for cables, suspension ropes, counterweights and other moving parts to prevent displacement and entanglement with elevator parts inside hoistway in case of building sway and earthquake. |
309 | Door nudging operation, Next landing operation, No Correction run function Auxiliary controller for Destination control system Braille symbols on buttons and special button on Destination Keypad for voice guidance for use by specially abled users Car Door mechanical interlock Cable provision for CCTV and PA system In case of controlled openings, Car buttons & DCS keypads shall be operational under key operation, attendant operation and / or under fireman"s operation Minimum 02 Blowers in Car to ensure 20 air changes per hour, with auto switch off if no call is made for 90 seconds. Self Levelling - ±5 mm , Stopping Accuracy - ±5 mm Elevator ceiling height – min. 2600mm. (Clear Car Internal height below False Ceiling) Adequate design of car required for reducing noise level and vibration due to piston effect (such as aerodynamic car, double isolation, etc.) One elevator in the Group to be designated as Fireman Elevator Steel channels for mounting Rail brackets and Wire Grills inside shaft Initialinspection by lift manufacture. Passenger Elevator as described above |
310 | Design, Fabrication, Supply, Installation, Testing & Commissioning of following Electric Traction Type fully automatic Machine room Elevator with Closed loop AC variable voltage & variable frequency drive unit suitable for operation on 415V, 3 Phase, 50 Hz. AC supply, having speed of 5.0 m/sec., power operated centre opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom suitable for hook up to building EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fire man"s switch at Main Landing floor and secondary recall floor (if specified), digital car position indicator in car & at all floors with up / down direction,light fixtures, ventilation fan, landing sill, main beam in Machine Room for machine mounting, pit ladder etc. complete with all accessories and with Automatic Rescue Device (ARD) complete with dry maintenance free sealed batteries as required etc.,and as under: - Elevator No. : SL-1 Capacity - 20 passengers (1360 Kgs) Speed - 5.0 mps Rise - 199.20 m (Approx.) No. of stops - 63 No. of regular openings - 62 (Floor - G,1~54,56~62) No. of controlled openings - 1 (Floor - 55) Shaft size - 2400 mm x 2700 mm (W x D) Car size - As per IS/NBC (Tentative Car size: 1500 mm W x 2100 mm D) Car Interior - Stainless Steel Hairline Finish (Grade 304) with minimum panel thickness of 1.5 mm Pit depth - 5500mm (Approx.) |
311 | Overhead - 8600mm (Approx.) Door Size: 1200 mm (Wide) x 2400 mm (High) Car Doors: Automatic Power operated, 2-Panel Telescopic opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness-1.5 mm Landing doors : 2-Panel Telescopic opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness-1.5 mm Operation - Microprocessor based single automatic push button / Duplex full collective control with / without attendant ARD for emergency operation Gong for all landings in Lobby Car Position indicator over Car door / at a suitable height on Front return panel Hall buttons on all landings Car operating panel - 01 No. inside Car 25 mm Recess for Flooring by Others and Floor weight provision 3-Way Built-in Intercom Facility suitable to hook up with building EPABX Software integration (with BMS & FAS System) Handrails on all sides Ceiling interior and light fixture shall be in scope of vendor Multibeam Full height Infra Red protection for Door Opening & Closing On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator. |
312 | Controller: Closed Loop A.C. variable voltage & variable frequency with harmonic arrestors to limit Total Harmonic Distortion below 5% Power- 415 V, 3 phase, 50 Hz, 4 wires system. Narrow Door frames of same finish as Landing doors on each landing Should have regenerative drives to save electricity Note: Additional load of 300kg shall be considered for Interior Designing. Operation / Grouping: Full Collective- Duplex with Service Lift SL-2 Other General Requirements Battery operated Emergency Light, Fan and Alarm Bell Audio & Visual Indication inside Car for Overload, ARD operation and Fireman operation Fireman Switch in Ground Floor and Secondary Recall Floor (if specified) Automatic rescue device suitable to operate for minimum 03 times without recharging (Access Hatch on Car top and False ceiling to be consider for each lift for emergency rescue) All Landing doors to have 01 Hour Fire resistance rating. Oil buffers, Adjustable Roller guides, Cast Iron Filler weights for Counterweight, Solid "T" Section machined Guide rails for all lifts Ascending Car Overspeed protection (ACOP) and Uncontrolled Car movement protection (UCMP) Earthquake operation with Primary and Secondary wave seismic sensors Retainers for cables, suspension ropes, counterweights and other moving parts to prevent displacement and entanglement with elevator parts inside hoistway in case of building sway and earthquake. |
313 | Door nudging operation, Next landing operation, No Correction run function, Anti-nuisance feature, Car Call Cancellation feature Braille symbols on car and landing buttons Car Door mechanical interlock Cable provision for CCTV and PA system In case of controlled openings, Car & Hall Buttons shall be operational under key operation, attendant operation and / or under fireman"s operation Minimum 02 Blowers in Car to ensure 20 air changes per hour, with auto switch off if no call is made for 90 seconds. Self Levelling - ±5 mm , Stopping Accuracy - ±5 mm Elevator ceiling height – min. 2600mm. (Clear Car Internal height below False Ceiling) Adequate design of car required for reducing noise level and vibration due to piston effect (such as aerodynamic car, double isolation, etc.) One elevator in the Group to be designated as Fireman Elevator Steel channels mounting Rail brackets and Wire Grills inside shaft Initialinspection by lift manufacture. Service Elevator as described above |
314 | Design, Fabrication, Supply, Installation, Testing & Commissioning of following Electric Traction Type fully automatic Machine room Elevator with Closed loop AC variable voltage & variable frequency drive unit suitable for operation on 415V, 3 Phase, 50 Hz. AC supply, having speed of 5.0 m/sec., power operated centre opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom suitable for hook up to building EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fire man"s switch at Main Landing floor and secondary recall floor (if specified), digital car position indicator in car & at all floors with up / down direction,light fixtures, ventilation fan, landing sill, main beam in Machine Room for machine mounting, pit ladder etc. complete with all accessories and with Automatic Rescue Device (ARD) complete with dry maintenance free sealed batteries as required etc.,and as under: - Elevator No. : SL-2 Capacity - 24 passengers (1632 Kgs) Speed - 5.0 mps Rise - 199.20 m (Approx.) No. of stops - 63 No. of regular openings - 62 (Floor - G,1~54,56~62) No. of controlled openings - 1 (Floor - 55) Shaft size - 2400 mm x 2700 mm (W x D) Car size - As per IS/NBC (Tentative Car size: 1600 mm W x 2200 mm D) Car Interior - Stainless Steel Hairline Finish (Grade 304) Pit depth - 5500mm (Approx.) |
315 | Overhead - 8600mm (Approx.) Door Size: 1200 mm (Wide) x 2400 mm (High) Car Doors: Automatic Power operated, 2-Panel Telescopic opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness-1.5 mm Landing doors : 2-Panel Telescopic opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness-1.5 mm Operation - Microprocessor based single automatic push button / Duplex full collective control with / without attendant ARD for emergency operation Gong for all landings in Lobby Car Position indicator over Car door / at a suitable height on Front return panel Hall buttons on all landings Car operating panel - 01 No. inside Car 25 mm Recess for Flooring by Others and Floor weight provision 3-Way Built-in Intercom Facility suitable to hook up with building EPABX Software integration (with BMS & FAS System) Handrails on all sides Ceiling interior and light fixture shall be in scope of vendor Multibeam Full height Infra Red protection for Door Opening & Closing On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator. |
316 | Controller: Closed Loop A.C. variable voltage & variable frequency with harmonic arrestors to limit Total Harmonic Distortion below 5% Power- 415 V, 3 phase, 50 Hz, 4 wires system. Narrow Door frames of same finish as Landing doors on each landing Should have regenerative drives to save electricity Note: Additional load of 350kg shall be considered for Interior Designing. Operation / Grouping: Full Collective- Duplex with Service Lift SL-1 Other General Requirements Battery operated Emergency Light, Fan and Alarm Bell Audio & Visual Indication inside Car for Overload, ARD operation and Fireman operation Fireman Switch in Ground Floor and Secondary Recall Floor (if specified) Automatic rescue device suitable to operate for minimum 03 times without recharging (Access Hatch on Car top and False ceiling to be consider for each lift for emergency rescue) All Landing doors to have 01 Hour Fire resistance rating. Oil buffers, Adjustable Roller guides, Cast Iron Filler weights for Counterweight, Solid "T" Section machined Guide rails for all lifts Ascending Car Overspeed protection (ACOP) and Uncontrolled Car movement protection (UCMP) Earthquake operation with Primary and Secondary wave seismic sensors Retainers for cables, suspension ropes, counterweights and other moving parts to prevent displacement and entanglement with elevator parts inside hoistway in case of building sway and earthquake. |
317 | Door nudging operation, Next landing operation, No Correction run function, Anti-nuisance feature, Car Call Cancellation feature Braille symbols on car and landing buttons Car Door mechanical interlock Cable provision for CCTV and PA system In case of controlled openings, Car & Hall Buttons shall be operational under key operation, attendant operation and / or under fireman"s operation Minimum 02 Blowers in Car to ensure 20 air changes per hour, with auto switch off if no call is made for 90 seconds. Self Levelling - ±5 mm , Stopping Accuracy - ±5 mm Elevator ceiling height – min. 2600mm. (Clear Car Internal height below False Ceiling) Adequate design of car required for reducing noise level and vibration due to piston effect (such as aerodynamic car, double isolation, etc.) One elevator in the Group to be designated as Fireman Elevator Steel channels mounting Rail brackets and Wire Grills inside shaft Initialinspection by lift manufacture. Service Elevator as described above |
318 | Design, Fabrication, Supply, Installation, Testing & Commissioning of following Electric Traction Type fully automatic Machine room Elevator with Closed loop AC variable voltage & variable frequency drive unit suitable for operation on 415V, 3 Phase, 50 Hz. AC supply, having speed of 5.0 m/sec., power operated centre opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom suitable for hook up to building EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fire man"s switch at Main Landing floor and secondary recall floor (if specified), digital car position indicator in car & at all floors with up / down direction,light fixtures, ventilation fan, landing sill, main beam in Machine Room for machine mounting, pit ladder etc. complete with all accessories and with Automatic Rescue Device (ARD) complete with dry maintenance free sealed batteries as required etc.,and as under: - Elevator No. : FL-1 Capacity - 20 passengers (1360 Kgs) Speed - 5.0 mps Rise - 199.20 m (Approx.) No. of stops - 63 No. of regular openings - 62 (Floor - G,1~54,56~62) No. of controlled openings - 1 (Floor - 55) Shaft size - 2650 mm x 2700 mm (W x D) Car size - As per IS/NBC (Tentative Car size: 1500 mm W x 2100 mm D) Car Interior - Stainless Steel Hairline Finish (Grade 304) Flooring - 6 mm Thick Stainless Steel Chequered Plate Pit depth - 5500mm (Approx.) |
319 | Overhead - 8600mm (Approx.) Door Size: 1100 mm (Wide) x 2400 mm (High) Car Doors: Automatic Power operated, 2-Panel Center opening horizontal sliding Stainless Steel Hair line finish (Grade 304), minimum panel thickness - 1.5 mm Landing doors : 2-Panel Center opening horizontal sliding Stainless Steel Hair line finish (Grade 304) on Ground Floor and MS Painted Finish on all other floors, minimum panel thickness - 1.5 mm Operation - Microprocessor based single automatic push button / Simplex full collective control with / without attendant ARD for emergency operation Gong for all landings in Lobby Car Position indicator over Car door / at a suitable height on Front return panel Hall buttons on all landings Car operating panel - 01 No. inside Car 3-Way Built-in Intercom Facility suitable to hook up with building EPABX Software integration (with BMS & FAS System) Ceiling interior and light fixture shall be in scope of vendor Multibeam Full height Infra Red protection for Door Opening & Closing Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator. |
320 | Controller: Closed Loop A.C. variable voltage & variable frequency with harmonic arrestors to limit Total Harmonic Distortion below 5% Power- 415 V, 3 phase, 50 Hz, 4 wires system. Narrow Door frames of same finish as Landing doors on each landing Should have regenerative drives to save electricity Note: Operation / Grouping: Full Collective- Simplex Other General Requirements Battery operated Emergency Light, Fan and Alarm Bell Audio & Visual Indication inside Car for Overload, ARD operation and Fireman operation Fireman Switch in Ground Floor and Secondary Recall Floor (if specified) Automatic rescue device suitable to operate for minimum 03 times without recharging (Access Hatch on Car top and False ceiling to be consider for each lift for emergency rescue) All Landing doors to have 01 Hour Fire resistance rating. Oil buffers, Adjustable Roller guides, Cast Iron Filler weights for Counterweight, Solid "T" Section machined Guide rails for all lifts Ascending Car Overspeed protection (ACOP) and Uncontrolled Car movement protection (UCMP) Earthquake operation with Primary and Secondary wave seismic sensors Retainers for cables, suspension ropes, counterweights and other moving parts to prevent displacement and entanglement with elevator parts inside hoistway in case of building sway and earthquake. Door nudging operation, Next landing operation, No Correction run function, Anti-nuisance feature, Car Call Cancellation feature Braille symbols on car and landing buttons |
321 | Car Door mechanical interlock Cable provision for CCTV and PA system In case of controlled openings, Car & Hall Buttons shall be operational under key operation, attendant operation and / or under fireman"s operation Minimum 02 Blowers in Car to ensure 20 air changes per hour, with auto switch off if no call is made for 90 seconds. Self Levelling - ±5 mm , Stopping Accuracy - ±5 mm Elevator ceiling height – min. 2600mm. (Clear Car Internal height below False Ceiling) Adequate design of car required for reducing noise level and vibration due to piston effect (such as aerodynamic car, double isolation, etc.) Initialinspection by lift manufacture. Fire Elevator as described above |
322 | ORGANIC WASTE CONVERTER |
323 | Supply, Installation, Testing & Commissioning of Waste Collection System complete all as specified and as directed by Engr-in-Charge as follows: Make: Anugrah Industry & Allied Services, Delhi; ESS ENN Energy Systems, Delhi; Greenvac Solutions Pvt. Ltd., New Delhi |
324 | Chute : Throat Piece With Sound Coating, interlocking Intake Hopper , Sanitation Unit , interlocking Control Panel, Brush Cleaning System, Fire sprinklers |
325 | Organic Waste Composter : Composting Machine is a fully automatic machine that quietly works behind the scenes, suitable for treatment of the mixed organic waste such as food/kitchen/garden segregated waste. |
326 | Fully automatic dry Waste Shredder Capacity of minimum 650 Kg per day. |
327 | AVIATION LIGHT |
328 | S& F of Aviation yellow painted die-cast aluminium alloy housing, built-in 75VA step up transformer, heat resistant, clear thick glass and accessories.as per ICAO-ANNEX 14 complete all as specified and directed by the engineer-in-charge. Make: BAJAJ Luminaire Type:BJAOL 1 with Neon Lamp Product No: 20075 or equivalent |
329 | S& F of Aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories as per ICAO-ANNEX 14 complete all as specified and directed by the engineer-in-charge. Make: BAJAJ Luminaire Type:BJAOL 2 BCProduct No: 24973 or equivalent |
330 | S & F weather- proof PVC junction box of size 139 mm x 119 mm x 70 mm, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos. of polymide gland with check nuts fixed on poles with flat aluminium clamps, nuts, bolts, washers, etc. complete all as specified and as directed by engineer- in- charge. Make: Sintex, Hensel, HPL |
331 | LIGHTNING PROTECTION |
332 | TIER I- AIR TERMINATION Supply,Installation,Testing & Commisioning of 1 metre Vertical Aluminium Air terminal of dia 15mmto meet the requirement of IS/IEC 62305.Tested for Electrical, Mechanical, Environmental test and should have Impulse current withstand capability of 100KA (Class H)andas perIEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. |
333 | Supply,Installation,Testing & Commisioning of Aluminium Air terminal base for dia15mm,1 meter long Air terminalto meet the requirement of IS/IEC 62305 .Tested for Electrical, Environmental test and should have Impulse current withstand capability of 100KA (Class H)andas perIEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. |
334 | Supply,Installation,Testing & Commisioning of 25x3mm Aluminum Tape Conductor with fixing accessoriesand should be tested for electrical resistivity test , Tensile strength, Environmental Test (salt spray & humidity test) to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. (Air Termination - 950, Down Conductor/Ring Conductor - 2550) |
335 | Supply,Installation,Testing & Commisioning of Aluminum Square Tape Clamp for Cross connection and T connection of 25x3mm Aluminium Tape should be tested for electrical resistivity test ,Environmental Test (salt spray & humidity test),Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. (Air Termination - 320, Down Conductor/Ring Conductor - 300) |
336 | Supply,Installation,Testing & Commisioning of U bolt rebar to Cable Clamp should be tested for Environmental Test (salt spray & humidity test),Contact resistance test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. (Air Termination - 14, Down Conductor/Ring Conductor - 210, Testing/Disconnecting Link - 14) |
337 | Supply,Installation,Testing & Commisioning of 50sq mmGreen/Yellow PVC insulated Copper cable with terminal Lug, should have Each stranded of 1.7 mm diameter as per requirements of IS/IEC 62305 and IEC 62561-2:2012 complete all as specified and as directed by the Engineer-in-Charge. (Air Termination - 14, Down Conductor/Ring Conductor - 210, Testing/Disconnecting Link - 14) |
338 | Supply,Installation,Testing & Commisioning of Bi-mettalic Connector should be tested for Environmental Test (salt spray & humidity test), Contact resistance test ,Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. (Air Termination - 14, Down Conductor/Ring Conductor - 210) |
339 | TIER II - DOWN CONDUCTORS / RING CONDUCTORS Supply,Installation,Testing & Commisioning of Moisturing inhibiting compound to meet the requirements of IS/IEC 62305 complete all as specified and as directed by the Engineer-in-Charge. |
340 | TIER III - TESTING / DISCONNECTING LINK Supply,Installation,Testing & Commisioning of Test link should be tested for Environmental Test (salt spray & humidity test),Contact resistance test, Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. |
341 | TIER IV -EARTHING SYSTEM Supply,Installation,Testing & Commisioning ofmaintenance free Earthing system comprising of 250micron copper bonded earth rod 3 mtr x 3/4" Dia long Earth electrode, inspection pit with polymer lid is load rated to 5000kg and suitable for general to heavy duty, copper rod to tape clamp and 25Kg of Earth Enhancingcompound whose resistivity is less than 0.12 as per IEEE 80-2013 & IS 3043-2018 for normal soil condition . The compound shall be free from carbon and graphite and conductive in nature and should accomodate 60% of its volume. The rod should be threaded on both ends and all component should betested as per IEC 62561 complete all as specified and as directed by the Engineer-in-Charge. Note: 3m length shall vary depending upon soil resistivity. |
342 | Supply,Installation,Testing & Commisioning of 25x3mm Copper Tape Conductor with fixing accessories and should be tested for electrical resistivity test , Tensile strength, Environmental Test (salt spray & humidity test) to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. |
343 | Supply,Installation,Testing & Commisioning of Copper Square Tape Clamp for Cross connection and T connection of 25x3mm Aluminium Tape should be tested for electrical resistivity test ,Environmental Test (salt spray & humidity test),Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2 complete all as specified and as directed by the Engineer-in-Charge. |
344 | HOT WATER SUPPLY |
345 | Supply and Fixing water heater storage type electric, capacity 25 Litrs, BEE 5 star rated,Rated power input-2000W,Rated Voltage & frequency-230 V, 1Phase, 50 Hz AC, Rated Input Current-8.69 A,Energy Efficiency feature-Energy saving high density PUF insulation,Geyser protection from water splash-IPX4 technology to protect electrical parts from water splash, No, Net contents-1 N storage electric water heater , 1 N user manual , 1 N multi-function safety valve , 2 Nfasteners & 2 N flexi pipes complete all as specified and as directed by the Engineer-in-Charge. Make: Havells, Product No:Monza DX GHWAMGTWH025,HSN Code:8516 or equivalent |
346 | TV/ TELEPHONE CONDUITS |
347 | S & F modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed by the engineer-in-charge. Make: Legrand Arteor Cat. Part No. 5734 26 or equivalent model of Havells or L&T or IndoAsian |
348 | S & F for 2 pair telephone cable having solid electrolytic annealed bare copper conductor of 0.5 mm nominal diameter with high density polyethylene insulation, paired, polyester taped, nylon rip cord and grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113 C including termination complete all as specified and directed by the engineer-in-charge. Make: Polycab, RR Kabel, Havells |
349 | S & F 5 pair telephone krone distribution box with suitable S.S. frame for mounting tag module, Krone module and incorporated in 16 SWG MS box with proper lockable cover. The box should be fixed on wall with suitable fasteners including painting & earthing. This also includes fixing the cable, distribution chart sufficient space for the cables, wires etc. complete all as specified and directed by the engineer-in-charge. Make: DELTA or equivalent of Sintex, Hensel, HPL |
350 | S & F modular type 1 module TV socket complete all as specified and directed by the engineer-in-charge. Make: Legrand Arteor Cat. Part No. 5734 25 or equivalent model of Havells or L&T or IndoAsian |
351 | S & F RG 6 coaxial cable having solid electrolytic grade annealed plain copper central conductor of 1.02mm nominal diameter, gas injected physical polyethylene foam insulated, wrapped with aluminium mylar tape aluminium alloy wire braided, jelly flooded and PVC jacketed including termination complete all as specified and directed by the engineer-in-charge. Make: Polycab CO-X, RR Kabel, Havells |
352 | Supply, fixing, installation, commissioning, training & testing IP CCTV SURVEILLANCE SYSTEM SOLUTION comprising of following subitems & systems: IP IR 2.0 MP HD Dome Camera - 32 Nos IP IR 2.0 MP HD Bullet Camera - 31 Nos Outdoor Camera Housing - 22 Nos 64 CH NVR with 8 SATA - 1 No 6 TB SATA HOD - 8 Nos 24 Port 10/100/1000 Mbps Auto-negotiation Gigabit Ethernet Unmanaged Full PoE Switch - 4 Nos GPON ONT 1 POrt 10/100/1000 Base-T RJ-45 - 5 Nos 24 Port CAT-6 Loaded Patch Panel - 4 Nos CAT-6 1 Mtr Patch Cord & Installation, implementation charges - 63 Nos 802 11 N150 Mbps Wireless Outdoor Access Point with Built in 12dbi Antenna / SMA Connector (PoE injector included) - 16 Nos CAT-6 Over HDMI Transmitter & Receiver Device (For NVR Display on TV) - 1 No 32" LGCommercial Display - 1 No NOTE: Anything not exclusively mentioned above but essentially required for delivery of IP CCTV SURVEILLANCE SYSTEM SOLUTION shall be provided by the contractor & no extra cost for the same shall be claimed on this account. |
353 | CIVIL WORKS FOR DG SET AND ELECTRICAL TRENCH (OUTSIDE BUILDING) |
354 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality H D - 20 Circular shape 560 mm internal diameter complete all as specified and directed by engineer-in-charge. |
355 | STANDBY POWER SUPPLY (DG) |
356 | Supply, installation, testing and commissioning of silent DG Set, conforming to IS: 10002- 1981, complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS: 13364- 1992, mounted on a common base frame & coupled through a flex disc complete with platform, control panel having meters, sound-proof canopy, etc. of capacity 400 kVA with inbuild AMF panel complete all as specified and directed by engineer-in-charge. Make:Kirloskar, Crompton Greaves, Ashok Leyland, Mahindra [a] Engine: 4/6 cylinder, in-line, 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator, air to air aftercooling, optimised turbocharger for increased altitude, Inline fuel pump with class H electronic governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, battery charging alternator with 1 x 24 or 2 X 12 V DC dry type battery. [b] Alternator: Brushless type, screen protected, revolving field, self-excited alternator, conforming to IS/IEC 60034-1 3-phase reconnectable winding with 12 terminals brought out for connection, dedicated winding specially designed for single operation, impregnation on all wound components for better mechanical strength [c] Control Panel: Manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts: [i] Controller: Aluminum bus bars with suitable capacity with incoming/outgoing terminals [ii] Indicating lamps for ‘Load ON’ and ‘Set Running’ [iii] Instrument fuses duly wired and ferruled |
357 | [iv] MCCB 600 Amps of suitable rating with overload and short circuit protections [d] Microprocessor based generator set monitoring and control system including an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics, LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps, remote START-STOP [e] Engine Metering: Oil pressure, engine temperature, starting battery voltage, engine running hours [f] AC Alternator Metering: L-L voltage and L-N voltage, current (phase and total), kVA (phase and total) and frequency [g] Engine Protection: Low lube oil pressure, high/low coolant temperature, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level [h] AC Alternator Protection: Over/under voltage, over/under frequency, loss of AC sensing. [i] Data Logging: Engine hours, control hours and upto 5 recent fault codes [k] 24 V DC operation [l] Silencer: Critical grade silencer suitably optimized to meet stringent noise emission latest standards of MoEF / CPCB [m] Mounting Arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. [n] Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning (h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. |
358 | Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department. |
359 | GENERATOR AUTO SYNCHRONIZING, AUTO LOAD SHARING AND LOAD BASEDSTART/STOPPANEL(400 KVA +400 KVA) Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directed by engineer-in-charge. (installed for 1000KVA TR main panel ) BUSBAR CHAMBER : 2000 Amps uniformly rated, continuous duty,415VAC, 3Phaseandfull size Neutral Aluminium(Throughout the length) busbarswith colour coded heat shrink sleeves supported onSMC type grip supports, 50 KA for 1 sec. |
360 | INCOMING a) 2 nos of 1000 A, 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The ACB shall be complete as per technical specifications b) 01 Nos. phase indicating light through protected by 2 amps MCB’s.- 1 set.Electronic Digital Load Manager with ready RS485 communication port and MODBUS protocol. - 1 set and 3 nos. c) 2000/5 amps, Bar Primary, 5 VA Burden, CL 1 accuracy CTs . - 1 set, 0-500 Volt digital voltmeter with selector switch shall be protected by 2 amp TP MCB’s - 1 set, Breaker ON / OFF / TRIP indicating lights with control MCB’s - 1 set. d) Synchronization Relay OUTGOING 1) 1250 amps 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The MCCB shall be complete as per technical specifications - 01 no. 2) 800 amps 4 pole ACB with TM based release for complete LSIG protections and suitable for 415V, 50 Hz, A.C Supply and having Ics = Icu= 50 KA. The MCCB shall be complete as per technical specifications - 01 no. NOTE: Operational Logic During power failure mode 1) Both DGs will start & synchronized. 2) If load is below 40% of total load then turn off one of DG. 3) If load is above 45% of total load then turn on 2nd DG. |
361 | SIGNAGE |
362 | Providing and fixing Photo Luminescent (Night Glow) Way Finding Ceiling Hug Sign 4 mm ACP Sheet (Aluminum Composite panel) Clouding with 1.5”x1”x1.5mm MS Frame coated spray paint Photo luminescent film Base Color Green Text Color Off White Text Size 75mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes /Hanging with SS Stards CAPED SS Wire screws complete as all specified and directed by engineer- in- charge. |
363 | (a) 350x200 |
364 | (b) 500x200 |
365 | (c) 600x300 |
366 | (d) 600x400 |
367 | Providing and fixing 525x500 Photo Luminescent (Night Glow) Photo Luminescent Floor Level 4 mm ACP Sheet (Aluminum Composite panel) Clouding with 1.5”x1”x1.5mm MS Frame coted spray paint Photo luminescent film Base Color Green Text Color Off White Text Size 75mm, 35mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes / with SS CAPED screws complete as all specified and directed by engineer- in- charge. |
368 | Providing and fixing 450x750 Photo Luminescent (Night Glow) Staircase Number Plate 4 mm ACP Sheet (Aluminum Composite panel) Clouding with 1.5”x1”x1.5mm MS Frame coted spray paint Photo luminescent film Base Color Red Text Color Off White Text Size 75mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes / with SS CAPED screwscomplete as all specified and directed by engineer- in- charge. |
369 | Providing and fixing 850x375 Photo Luminescent (Night Glow) Photo Luminescent Escape Signage 4 mm ACP Sheet (Aluminum Composite panel) Clouding with 1.5”x1”x1.5mm MS Frame coted spray paint Photo luminescent film Base Color Red Text Color Off White Text Size 75mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes / with SS CAPED screws complete as all specified and directed by engineer- in- charge. |
370 | Providing and fixing Photo Luminescent (Night Glow) Photo Luminescent Refuge Signage 4 mm ACP Sheet (Aluminum Composite panel) Clouding with 1.5”x1”x1.5mm MS Frame coted spray paint Photo luminescent film Base Color Green Text Color Off White Text Size 75mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes / with SS CAPED screws complete as all specified and directed by engineer- in- charge. |
371 | (a) 350x550 |
372 | (b) 400x700 |
373 | Providing and fixing 450x250 Photo Luminescent (Night Glow) Photo Luminescent Floor Indication Board Signage 4 mm ACP Sheet (Aluminum Composite panel) Photo luminescent film Base Color Green Text Color Off White Text Size 75mm, 35mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes / with SS CAPED screws complete as all specified and directed by engineer- in- charge. |
374 | Providing and fixing 600x400 Photo Luminescent (Night Glow) Photo Luminescent Floor Plan with Location of Wet Riser/Hydrant Signage 4 mm ACP Sheet (Aluminum Composite panel) Clouding with 1.5”x1”x1.5mm MS Frame coted spray paint Photo luminescent film Base Color Green Text Color Off White Text Size 45mm, 35mm and Vinyl Graphics mounted directly using 3M Self Adhesive tapes / with SS CAPED screws complete as all specified and directed by engineer- in- charge. |
375 | DUSTBIN |
376 | Supply and fixing Cello wheel garbage waste dustbin 120 LTR complete as all specified and directed by engineer- in- charge. (Green Combo - 21, Blue Combo - 21, Yellow Combo - 21) |
377 | Supply and fixing Aristo 5 LTR Pedal splash dustbin (green) complete as all specified and directed by engineer- in- charge. |
378 | Supply and fixing Aristo 5 LTR Pedal splash dustbin (blue) complete as all specified and directed by engineer- in- charge. |
379 | Supply and fixing Aristo utility dustbin 5 LTR (yellow) complete as all specified and directed by engineer- in- charge. |
380 | SAFETY NET |
381 | Providing & fixing of Fall Arrest Safety Net all around the builing at 6th floor level as per IS-11057:19841, Fabricated from ISI marked polypropylene ropes (IS-5175:1992) in knitted mesh of overall outer size 6mtx4mt. Having outer tie cord 12mm thickness and inner rope thickness 4mm tied on a grid of 100mm x 100mm with overlay shade net of 2mm dia. knitted at a square grid of 25mm size (weight of shade net should be minimum 50 gram per sqmt.). These safety net should be tied / connected with the MS frame fixed to the building through 6mm thick MS plate along with dash fasteners M10 x 100 (Hilti / fisher / wurth) as base of structure fixed with 50x50mm MS square pipe with minimum 2 coats of zinc oxide primer complete in all aspects. This base frame should be at the interval of 3mt or complete all as per Architectural drawings, as specified and as directed by the Engineer-in-Charge. |
382 | HORTICULTURE AND LANDSCAPE |
383 | [A] HORTICULTURE DEVELOPMENT Site preparation M&L for Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared complete all as specified and as directed by Engr-in-Charge. |
384 | Grass Areas M&L for Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water complete all as specified and as directed by Engr-in-Charge. (excluding cost of imported earth, sludge or manure) |
385 | M&L for Rough dressing the trenched ground including breaking of clods complete all as specified and as directed by Engr-in-Charge. |
386 | M&L for Fine dressing of the ground complete all as specified and as directed by Engr-in-Charge. |
387 | M&L for Spreading of sludge, dump manure and/or good earth in required thickness complete all as specified and as directed by Engr-in-Charge. (cost of sludge, dump manure and/ or good earth to be paid separately) |
388 | M&L for Mixing earth and sludge or manure in the required proportion complete all as specified and as directed by Engr-in-Charge. |
389 | Cost of Grass Supply of Selection no1. grass turf in forms of Carpet complete all as specified and as directed by Engr-in-Charge. |
390 | M&L for Grassing with selection No.1 grass turf including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed complete all as specified and as directed by Engr-in-Charge. (the good earth shall be paid for separately) |
391 | Tree Planting M&L for Digging Holes 90cm dia. and 90cm deep. and refilling the same with excavated earth mixed with manure or sludge 2 :1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing including removal of rubbish and surplus earth if any with all leads and lifts complete all as specified and as directed by Engr-in-Charge. (Cost of manure / sludge or extra good earth if needed to be paid extra) |
392 | Shrub and Ground Cover Planting M&L for Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete all as specified and as directed by Engr-in-Charge. (cost of sludge, manure or extra earth to be paid for separately) |
393 | M&L for Topairy cutting/shapping of plant removing of cut materials, cleaning, hoeing of plants complete design hoeing of trees (Topairy) watering manure etc. complete all as specified and as directed by Engr-in-Charge. (excluding the cost of material which shall be supplied by the department) |
394 | M&L for Digging Holes 60 cm dia, and 60 cm deep and refilling the same with excavated earth mixed with manure or sludge 2 :1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing including removal of rubbish and surplus earth if any with all leads and lifts complete all as specified and as directed by Engr-in-Charge. (Cost of manure / sludge or extra good earth if needed to be paid extra) |
395 | Earthwork in Mounds, Sweet Earth filling and Manure Supplying and stacking of good earth at site including royalty and carriage up to 1 km lead complete all as specified and as directed by Engr-in-Charge. (earth measured in stacks will be reduced by 20% for payment) |
396 | Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete all as specified and as directed by Engr-in-Charge. (ecattle manure measured in stacks will reduced by 8% for Payment) |
397 | [B] TREES and PALMS Supplying trees/ lawn/ palms/ plants as per specifications mentioned in annexure 1 of specification of tender and as per approval and direction of engineer-in-charge. |
398 | (a) Azardirachta indica |
399 | (b) Delonix Regia |
400 | (c) Ficus racemosa |
401 | (d) Ficus infectoria |
402 | (e) Lagersteroemia indica |
403 | (f) Plumeria alba |
404 | (g) Polyalthia longifolia |
405 | SHRUBS Supplying shrubs as per specifications mentioned in annexure 1 of specification of tender and as per approval and direction of engineer-in-charge. |
406 | Large Shrubs (1800mm Ht.) (a) Hibiscus rosa sinensis |
407 | (b) Ficus black prince |
408 | (c) Tecoma gaudichaudi |
409 | Medium Shrubs (750mm Ht.) (a) Casurina equastifolia |
410 | (b) Cassia biflora |
411 | (c) Ficus Kingbush |
412 | (d) Ficus panda |
413 | (e) Hamelia patens |
414 | (f) Tabernae montana coronaria"var" |
415 | (g) Rhaphis excelsa |
416 | Small Shrubs (a) Yucca aloifolia |
417 | Bamboos Supplying bamboos as per specifications mentioned in annexure 1 of specification of tender and as per approval and direction of engineer-in-charge. Bambusa ventricosa |
418 | PALMS & CYCADS Supplying palms & cycads as per specifications mentioned in annexure 1 of specification of tender and as per approval and direction of engineer-in-charge. Royestonia regia |
419 | GROUND COVERS Supplying ground covers as per specifications mentioned in annexure 1 of specification of tender and as per approval and direction of engineer-in-charge. Roheo gold |
420 | [D] PAVER AREA FOR PARKING WORK Providing and fixing 18-20mm thick Granite stone (of any type) work (table rubbed and polished) flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) complete all as specified and directed by engineer-in-charge. |
421 | M & L, 40 MM THK. HDPE GRASS PAVERS complete all as specified and directed by engineer-in-charge. |
422 | BLANK |
423 | MANNING & OPERATIONOF LIFTS |
424 | Manning & Operation of fully automatic electrically operated passengerlift of any make, type and 20 passenger total 63 floors, speed 5m/sec, SS lift installed in the subject project as per schedule for supply and fix given above by placing 2 x lift operator in 2 shifts of 8 hrs including Sunday and holiday (0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs) including taking care of all lifts from any pilerage or damage etc (Total 9 Nos lifts) + 1 person at night including Sunday & holiday during the defects liability period of the project:- |
425 | (a) First year (11 Months after completion of Phase II) |
426 | (b) Second year (11 Months after completion of 1 year Manning & Operation in Phase III) |
427 | NOTE :- (a) 1st year the contractor shall be responsible for periodical maintenance, as per maintenance schedule attached and specified including renewal/replacement of parts, fittings/fixtures filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturers instructions. (b) The Contractor shall Employ Refrigeration mechanic having minimum ITI qualification from Govt Recognised institute with adequate knowledge & minimum 2 years experience inmaint/operation of AC plants. The operator must competent to carry out the minor maint all as directed. (TOTAL number of operators required per day are 02 nos.) (c) Contractor shall pay the wages to the employees through e-payment i.e. Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge) shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified. (d) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailing scales as laid down by Ministry of labour for all operator/helper (as applicable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. |
428 | The quoted rates shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent. (e) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department. (f) Each shift duration shall be 8 hours & duty timing will be decided by Engr-in-Charge. (g) The unit rate quoted shall deemed to be included for cost of labour for daily routing maintenance for trouble free functioning of installation. (h) In case of any abnormal noise/complaint the plant should be put off and same should be brought to the notice of Engr-in-charge. (i) The operator employed by the contrcator shall be capable of carrying out minor repair/maintenance and should have well experience in AC plants as applicable. (j) The quoted rate is deemd to be inclusive of cotton waste, cleaning material etc & Contractor will ensure general area cleanliness and upkeep of the installation on daily basis. (k) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of AC plants. |
429 | (l)The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In cas eof failure to provide tools kit & saftey kit (spanner sets, hand gloves), a penalty of Rs 3000/- will be recovered and levied. (m) The Contractorshall not employ same trademans continuously for more than 11 months during the Contract period. (n) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved. In case of failure, a penalty of Rs 2000/- per uniform will be levied and recovered from their dues. (o) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day"s Manning & Operation derived from pro rate of Sch "A" quoted rates. (p) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contrcat period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. (q) The contractor shall provide board at proper location near each installations duly writing the name of operators and Mobile Numbers shiftwise. |
430 | COMPREHENSIVE MAINTENANCE OF LIFTS |
431 | Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift of any make and 20 Passenger, 1360 Kgs Total floor - 63 floor speed 5m/sec, SS lift installed in the subject project as per schedule for supply & fix given above (Total 6 Lifts) of car size tentative 1700 X 1800 comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
432 | (a) 1st year after expiry of defects liability period |
433 | (b) 2nd year after expiry of defects liability period |
434 | (c) 3rd year after expiry of defects liability period |
435 | Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift of any make and 20 Passenger, 1360 Kgs, Total floor - 63 floor, speed 5m/sec, SS capacity lift installed in the subject project as per schedule for supply & fix given above (01 Lift) of car size tentative 1500 X 2100 comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
436 | (a) 1st year after expiry of defects liability period |
437 | (b) 2nd year after expiry of defects liability period |
438 | (c) 3rd year after expiry of defects liability period |
439 | Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift of any make and 24 Passenger, 1632 Kgs, Total floor - 63 floor, speed 5m/sec, SS capacity lift installed in the subject project as per schedule for supply & fix given above (01 Lift) of car size tentative 1600 X 2200 comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
440 | (a) 1st year after expiry of defects liability period |
441 | (b) 2nd year after expiry of defects liability period |
442 | (c) 3rd year after expiry of defects liability period |
443 | Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift of any make and 20 Passenger, 1360 Kgs, Total floor - 63 floor, speed 5m/sec, SS capacity lift installed in the subject project as per schedule for supply & fix given above (01 Lift) of car size tentative 1500 X 2100 comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
444 | (a) 1st year after expiry of defects liability period |
445 | (b) 2nd year after expiry of defects liability period |
446 | (a) 3rd year after expiry of defects liability period |
447 | Notes :- (i) Rates quoted under Sch A shall be for both materials and labour complete unless mentioned otherwise. (ii) After expiry of the defects liability period of 24 months from the certified date of completion of work, Government reserves the right to order the contractor to carryout comprehensive maintenance services of the lift (provided by him under Sch A in accordance with terms and conditions detailed in Sch A and specifications enclosed thereoff in the event of Govt. exercising the above right, the terms of comprehensive maintenance service contract shall be for a period of three years. Total period of comprehensive maintenance service contract of the lift shall be three years from the expiry date of the details liability period. (iii) The contractor shall enter in to a MOU with the OEMs for the provision of the lift and further maintenance. The MOU for the post waranty/post defect liability period between the contractor the contractor and OEM shall be submitted at least six months prior to the issue of completion certificate of the main contract. (iv) The rate quoted under this Sch Ashall be deemed to include for materials and labour required for comprehensive maintenance including repairs. |
448 | (v) The work covered under Sch Awill be ordered on the contractor by the respective Garrison Engineer on every year through a separate works order for the lifts installed in their area at the rate quoted by the contractor till completion of three years comprehensive maintenance. (vi) This contract shall be opetative for the period of three years after expiry of defect liability period only for the purpose of comprehensive maintenance. |
449 | COMPREHENSIVE MAINTENANCE OF ORGANIC WASTE CONVERTER |
450 | Comprehensive maintenance and repair of fully automatic electrically operated organic waste converter of any make installed against BOQItem No. 29.01 to 29.04 comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
451 | (a) 1st year after expiry of defects liability period |
452 | (b) 2nd year after expiry of defects liability period |
453 | (a) 3rd year after expiry of defects liability period |
454 | COMPREHENSIVE MAINTENANCE OF WIMAX CPE STATIONS |
455 | Comprehensive Maintenance of outdoor type Wimax CPE stations installed against BOQItem No. 27.27 comprising of all devices and accessories through out 12 months on all days including holidays for period of 03 years after expiry of defects liability period as shown below and all as specified and directed by GE. |
456 | (a) 1st year after expiry of defects liability period |
457 | (b) 2nd year after expiry of defects liability period |
Copyright © 2023 · All Rights Reserved. Terms of Usage | Privacy Policy