Tender For Hyderpora Ward Office Redevelopment ( Electrical Part ) , hyderpora-Jammu And Kashmir

Srinagar Municipal Corporation has published Tender For Hyderpora Ward Office Redevelopment ( Electrical Part ) . Submission Date for this Tender is 11-04-2022. Building Repair Tenders in hyderpora Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

31663290
Tender For Hyderpora Ward Office Redevelopment ( Electrical Part )
Open Tender
Indian
Jammu And Kashmir
hyderpora
11-04-2022

Tender Details

Tender For Hyderpora Ward Office Redevelopment ( Electrical Part )

Key Value

Document Fees
INR 2490 /-
EMD
INR 79740.0 /-
Tender Value
INR 39.87 Lakhs /-

BOQ Items

Name of Work: HYDERPORA WARDOFFICE REDEVELOPMENT(ELECTRICAL PART)
Sl. No. Item Description
1LIGHT POINTS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group - C
2Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group - C
3Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 6 sq.mm + 1 X 6 sq.mm earth wire
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 4 X 6 sq.mm + 2 X 6 sq.mm earth wire
8Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double door
9Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) a) 8 way (4 + 24), Double door
10Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
11Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
13Supply of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired to the terminal block & mounted on are movable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories. a) 20W LED Surface Type Light Fixture (Make: Philips Cat No. BN150W LED20S-6500 PSE OD GR / Wipro cat no LL20-281-XXX-65-AL1)
14b) 2"x2" LED Recessed Type Light Fixture (Make: Philips Cat No. RC365B LED33- 6500 PSU OD WH / Wipro cat no CRCO10R036HP57G1)
15c) LED Ceiling Light Fixture Recessed Type(Make: Philips Cat No. RS271B LED20/830 PSU-E NB WH / Wipro cat no LD56-251-060-40-XX)
16D) LED Ceiling Light Fixture Surface Type (Make: Philips Cat No. DN170C LED10S-6500 PSU WH / Wipro cat no `LD99-151-XXX57SMWH)
17E) 1 x 4W LED Bulk Head Light Fixture Make: Philips Cat No.Make: Philips Cat No. WT202W LED6S CW PSU S2 PC / Wipro cat no LW07-141-XXX-57-XX)
18Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
19Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
20Supply of following 900 RPM Exhaust fan non metalic suitable for single phase 230/240V, AC Supply complete with motor louvers , mounting brackets, all accessories etc complete as required. a) 200mm dia
21Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep
22Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
23Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
24Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
25Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
26Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
27Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) a) 8 way (4 + 24), Double door
28Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A
29Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
30Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted indoor MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium bus bar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturer with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. MV PANEL-1 INCOMING : 250 Amp 4P (35KA) moulded case circuit breaker with operating handle - 1 Nos METERING : 0-500V Digital Voltmeter with selector switch and MCBs - 1 Set 0-250A Digital Ammeter with CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch - 1 Set LED Phase indication lamps with individuals MCBs and control with toggle swithes - 1 Set CT Operated Load Manager (Similar to EM-6400) - 1 Set BUSBAR: 300 Amp. TPN Al. Busbar. OUTGOING : 100 Amp 4P (35KA) moulded case circuit breaker with operating handle - 2 Nos 63 Amp 4P (25KA) moulded case circuit breaker with operating handle - 5 Nos Notes:- All MCCB shall have Thermal - Magnetic Release.
31MV PANEL-2 100 Amp 4P (25KA) moulded case circuit breaker with operating handle - 1 Nos METERING : 0-500V Digital Voltmeter with selector switch and MCBs - 1 Set 0-100A Digital Ammeter with CTs of ratio 100/5A Class 1 Accuracy and 15VA burden and selector switch - 1 Set LED Phase indication lamps with individuals MCBs and control with toggle swithes - 1 Set BUSBAR: 125 Amp. TPN Al. Busbar. OUTGOING : 40 Amp DP (10KA) miniature circuit breaker - 12 Nos 10-60 Asingle phase direct reading energy meter - 7 Nos Notes:- All MCCB shall have Thermal - Magnetic Release.
32Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (for Telephones) a) 25 mm
33Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Telephone socket outlet
34Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 1 or 2 Module (75 mmX75 mm)
35Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 Pair
36Supply and installation of following size Krone connectors in MS box complete as required. a) 10 Pair
37Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (60 cm deep) and re-filling etc. as required a) 80 mm dia
38Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
39Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
40Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
41Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
42Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
43Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
44Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
45Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
46Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
47Supplying of XLPE insulated, PVC sheathed 1.1 KV grade aluminium conductor armoured power cable as per IS : 7098 of following sizes: 3.5 core 185 sq. mm.
483.5 core 50 sq. mm.
492 core 6 sq. mm.
50Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
51Above 95 sq. mm and upto 185 sq. mm
52Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
53Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
54Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
55Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 core 185 sq. mm.
563.5 core 50 sq. mm.
572 core 6 sq. mm.
58AREA LIGHTING Supply, erection, testing and commissioning of individual 3mtr long(600mm below Ground) 65mm dia Class B GI pole, 750mm out reach single arm complete with base plate FRP terminal box, wiring from terminal to the fixture with 3core 2.5sq.mm copper conductor cable, MCB control and 2nos of 40mm dia Class B GI pipe for incoming and outgoing cable etc including PCC foundation, pedestal and Supply and installation of 45W LED Lamp Post top Lantern fixture Integral type with Lamp and Controlgear/driver etc complete as required. (Make : Wipro cat no LP02-501-XXX-57-XX / Philips cat no BDS670 GRN40)
59Providing of Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments complete as required.
60Supply, installation , testing and commisionning of AC"s Hot and coldsplit type with provding of required capacity voltage stabilizer including all carriage complete job
61Supply, installation , testing and commisionning of AC"s Hot and coldsplit type with provding of required capacity voltage stabilizer including all carriage complete job
62Supply, Installation, Testing & Commissioning of 11/0.433 pole mounted 100 KVA 3-phase distribution transformer along with all accessories required for new creation complete job such as 9 meter steel tabular poles, ACSR conductor 30 sqmm,Surge Arrestor, 11 KV GO AB Switch 3 phase 3 pole 200 Amp vertical type, 11 KV horn gap shoes, set 3 phase, 185 sqmm cable single core as required, earthing etc. Disc 11 KV polymeric composite Discs, LT Distribution box, 3 phase 4 wire thread through Energy meter with CT, HP SECURE, Cement bottoming, painting of poles. The job also includes HT extension work or other if required at site.