Construction Of 02 Nos 120 Men Barracks And 16 Nos Type -Ii Quarters With Site Development Work 31St Bn Itbp At Yupia ( Arunachal Pradesh ) (Sh- Remaining Balance Structural And Finishing Works), Papum Pare-Arunachal Pradesh

Indo Tibetan Border Police Force-ITBP has published Construction Of 02 Nos 120 Men Barracks And 16 Nos Type -Ii Quarters With Site Development Work 31St Bn Itbp At Yupia ( Arunachal Pradesh ) (Sh- Remaining Balance Structural And Finishing Works). Submission Date for this Tender is 08-04-2022. Barrack Tenders in Papum Pare Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31625849
Construction Of 02 Nos 120 Men Barracks And 16 Nos Type -Ii Quarters With Site Development Work 31St Bn Itbp At Yupia ( Arunachal Pradesh ) (Sh- Remaining Balance Structural And Finishing Works)
Open Tender
Indian
Arunachal Pradesh
Papum Pare
08-04-2022

Tender Details

Construction Of 02 Nos 120 Men Barracks And 16 Nos Type -Ii Quarters With Site Development Work 31St Bn Itbp At Yupia ( Arunachal Pradesh ) (Sh- Remaining Balance Structural And Finishing Works)

Key Value

Document Fees
Refer document
EMD
INR 2363976.0 /-
Tender Value
INR 13.63 Crore /-

BOQ Items

Name of Work: C/O 02 No. 120 Men Barracks and 16 no. Type-II Quarters with site development work 31st Bn, ITBP at Yupia (Arunachal Pradesh ) (S/H: Remaining balance structural and finishing works).
Sl. No. Item Description
1By Mechanical Transport including loading,unloading and stackingEarth, Lead - 1 km
2Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge All kinds of soil
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
4Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources).
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources).
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mmnominalsize derivedfromnatural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling&dressing & finishing the top smooth.
10Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived fromnatural sources: 3 graded stone aggregate 20 mm nominalsize derived from natural sources).
11Reinforced cement concrete work in walls (any thickness), including attachedpilasters,buttresses,plinthandstring courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources).
12Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
13Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform
14Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers
15Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
16Centering and shuttering including strutting, propping etc. and removal of form forStairs, (excluding landings) except spiral-staircases
17Centering and shuttering including strutting, propping etc. and removal of form for Under 20 cm wide
18Centering and shuttering including strutting, propping etc. and removal of form forWeather shade, Chajjas, corbels etc., including edges
19Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
20Providing and filling in position, blown bitumen in expansion joints.
21Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick.150 mm wide
22Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick.200 mm wide
23Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
24Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge for the following grades of Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
25Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
26Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
27Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
28Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
29Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
30Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
31Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm
32Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite work
33Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
34Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
35Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
36Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
37Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
38Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
39Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately)Second class teak wood35 mm thick shutters
40Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately)Second class teak wood 30 mm thick shutters
41Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes4 mm thick glass pane (weight not less than 10kg/sqm).
42Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
43Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
44Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
45Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
46Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
47Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
48Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
49Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
50Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm
51Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100x10 mm
52Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
53Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm
54Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
55Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
56Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
57Providing and fixing 2nd class teak wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/nails on the edges of the Pre-laminated particle board as per direction of Engineer-in-charge.
58Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type)
59Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer"s specification and direction of Engineer-in-charge.
60Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer"s specifications and direction of Engineer-in-charge.Non decorative finish
61Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
62Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thickMarine plywood conforming to IS: 710
63Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required sizeSecond class teak wood
64Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
65Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
66Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
67Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
68Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
69Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
70Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.
71Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
72Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
73Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
74Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
75Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
76Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
7712 mm cement plaster of mix1:4 (1 cement: 4 coarse sand)
7815 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
79Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
80Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster
81Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 1:3 (1 cement : 3 fine sand)
82Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
83Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
84vFinishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
85Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
86Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
87Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
88Applying priming coat:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
89Painting with synthetic enamel paint of approved brand and manufacture to give an even shadeTwo or more coats on new work
90Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
91Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
92Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
93Supplying and stacking at site.90 mm to 45 mm size stone aggregate
94Supplying and stacking at site.53 mm to 22.4 mm size stone aggregate
95Supplying and stacking at site.Moorum
96Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
97Supplying, stacking and Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling.With road roller/ hand roller
98Surface dressing on new surface with paving bitumen of grade VG - 10 of approved quality using 2.25 kg of bitumen per sqm with 1.65 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete:
99Surface dressing one coat on new surface with bitumen of specified grade at a rate of 1.95 kg/sqm of surface area with 1.5 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity , etc. complete :Using bitumen emulsion (minimum 50% bitumen content- RS grade conforming to IS : 8887)
100Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : On W.B.M. @ 0.75 Kg / sqm
1012.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately).With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt
102Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete.
103Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
104Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
105Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
106Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
107Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
108Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board :510x1040 mm bowl depth 250 mm
109Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain boardKitchen sink without drain board 610x460 mm bowl depth 200 mm
110Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia
111Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
112Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
113Providing and fixing soil, waste and vent pipes :Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989100 mm dia
114Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :For 100 mm dia pipe
115Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia Sand cast iron S&S as per IS - 3989
116Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS : 3989
117Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100 mm Sand cast iron S&S as per IS - 3989
118Providing and fixing single equal plain junction of required degree :100x100x100 mmSand cast iron S&S as per IS - 3989
119Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989
120Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet100 mm
121Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outletSand cast iron S&S as per IS: 3989
122Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work 100 mm diameter pipe
123Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
124Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall15 mm nominal outer dia Pipes
125Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall20 mm nominal outer dia Pipes
126Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall25 mm nominal outer dia Pipes
127Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall32 mm nominal outer dia Pipes
128Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
129Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work40 mm dia nominal bore
130Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work50 mm dia nominal bore
131Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete50 to 80 mm nominal bore
132Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)25 mm nominal bore
133Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 40 mm nominal bore
134Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)50 mm nominal bore
135Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
136Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length15 mm nominal bore
137Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
138Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :40 mm diameter pipe
139Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :50 mm diameter pipe
140Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :40 mm diameter pipe
141Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :50 mm diameter pipe
142Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):25 mm nominal bore
143Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 40 mm nominal bore
144Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 50 mm nominal bore
145Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
146Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
147Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
148Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
149Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
150Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
151Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :250 mm diameter
152Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe
153Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 250 mm diameter S.W. pipe
154Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
155Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design N MInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
156Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
157Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
158Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
159Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
160Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
161Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requireGroup B
162Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductorsinglecorecableinsurface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
163Wiringforlight/powerplugwith 2X4sq.mmFRLSPVC insulatedcopperconductorsinglecorecableinsurface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
164Wiringforlight/powerplugwith 4X4sq.mmFRLSPVC insulatedcopperconductorsinglecorecableinsurface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
165.Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
166Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire
167Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
168Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire
169Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
170Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required6 x 1.5 sq. mm
171Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required9 x 1.5 sq. mm
172Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
173Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
174Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.20 mm
175Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required25 mm
176Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required32 mm
177Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
178Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
179Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
180Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
181Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)
182Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
183Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
184Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
185Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
186Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
187SupplyingandfixingPVC batten/angle holderincluding connections etc. as required.
188Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 16 KA,TPMCCB
189Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, ma200 A, 16 KA,TPMCCB
190Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
191Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
192Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
193Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
194Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required.Single pole
195Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required.Single pole and neutral
196Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required.Triple pole
197Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. Triple pole and neutral
198Supplyingandfixingfollowingrating,doublepole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
199EarthingwithG.I.earthpipe 4.5metrelong,40mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
200Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
201Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
202Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
203Providing and laying earth connection fromearth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
204Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
205Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
206Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85mm dia6 mmthickG.I.baseplate includingholesetc. complete as required.
207Jointing copper / G.I. tape (with another copper/ G I tape, base ofthe finial or any other metallic object) byriveting / nut bolting/ sweating and soldering etc as required.
208Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
209Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
210Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
211Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
212Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
213Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
214Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)
215supplyinginstallation , testing and commissioning of pre wiredfluorecent / compact fluorocent / LED light fitting surface / recessed type complete with all accessories and tube etc. As reqd ( similar fitting shall be approvedby Engineer in charge before procurement and its shall be in company catalogue and price lista) Surface mounting 2" X 2" LED fixture, 33 watt, 3300 lumens efficiency output not less than 90 lm / watt, THD <10%., PF >0.9 havingpowder coated CRCA / die cast aluminium housing with high efficiency opal dish diffuser, CCT 5700-6500 kelvin with electronic driver, 50000 hrs burning for lifetime etc. complete as required (Philips cat No:-SM 365 C LED 33-6500 PSU OD WH / Wipro cat no. CRC010S036 HP57G1 / Lighting technologies code- S03657ROEO + ASS0003/ Trilux cat no. Enterio D IND LED 3600-857 ET).
216Surface / ceiling mounted LED fittings circular / square shape 12W, 1000 lumens output, system efficiency not less than 85 lm / watt, having High grade polycarbonate / CRCA housing with diffused optic, CCT 6500 K, CRI >80, PF > 0.9, 30,000 burning hours lifetime, IP 20 with high grade (Philips cat no SM 250C LED12S- 6500 PSU WH / Wipro cat no. LD80/81-101-XXX-60-SM)
217Surface mounted 18-20 watt LED fixture batten type of 4" Long, CCT 5700-6500 K with electronic driver complete with extruted aluminium housing with high efficiency poly carbonate diffuser, system efficiency not less than 95 lm / watts, CRI 80, THD < 10%, PF> 0.90, 50000 hrs burning for life time etc as required (Philips cat No. BN 150W LED 20S-6500 PSE OD GR / Lighting technologies code - W018575000)
218Surface mounted 10-13 watt LED fixture batten type of 2" Long, CCT 5700-6500 K with electronic driver complete with extruted aluminium housing with high efficiency poly carbonate diffuser, system efficiency not less than 95 lm / watts, CRI 80, THD < 10%, PF> 0.90, 50000 hrs burning for life time etc as required (Philips cat No. BN 150W LED 13S-6500 PSE OD GR / Lighting technologies code - W009575000 )
219LED Bulk head fitting having output 600 lumens symmetric optics system wattage not more than 10 w , colour temp. 6500k ,CRI > 80, IK 9 IP 56 made from high pressure diecast alluminium poly corbonate cover , THD <20% pf >.09 having long life of 50000 hrs etc complete as required similar to Philips cat no. WT202 LED 6S NW 6500 PSU S2 PC /GE/thorn with similar specification
220Supplying, Installation, testing and commissioning of ceiling fan (without regulator), including wiring the down rod of standard length (upto 30 cm) with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable etc. as required.(Make-Crompton,Orient,havells)a) 1200 mm ( 5 Star Rating)
221Supplying, installation, testing and commissioning of following size exhaust fanin the existing opening i/c making the hole to suit the size of the fan, making good the damages, connection, testing and commissioning etc. complete as required. (a) 300 mm Sweep 900 rpm, heavy duty with louver / shutter
222Supply ,installation,testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following : complete in all respect as reqd. a) Monoblock pump set with bronze impeller, stainless steel shaft ,mechanical seal ,cast iron body ,450 LPM ,40 meter head complete withsuitable rating induction motor TEFC type suitable for operation on 415volts, 3phase, 50HZ AC, 2950 RPM for enclosure, horiziontal foot mounted type with class B or F insulation etc complete as reqd.c) suitable cement concrete foundation duly plastered complete with anti vibration pads.
223Fabrication, Supplying, Installation, Testing & Commissioning of out door type electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm. thick CRCA sheet,compartmentalised with hinged lockable doors,dust and vermin proof, powder coated of approved shade , cablealley,inter-connection,having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 HZ. AC supply with enclosure protection class IP 52 i/c P/F following accessories etc. as required ,A Terrace pump control(for two pumps) (1) INCOMER (a)4 pole 100 Amps. MCCB 25 KA. thermal magnetic release (Ics= 100 %Icu).- 1No.b) Digital type Voltmeter (0 - 500 Volts) with selectorswitch -1 Set.(c) Digital type Ammeter with selectorswitch & CT"s etc. - 1 Set.(d) LEDtype indicating lights - 3 Nos.(e) TP & N AL. bus bar 200 Amps rating - 1 Set.(ii) OUTGOING
224Supplying ,laying and fixing of one number PVC insulated and PVC sheathed, XLPE Aluminium conductor armoured power cable 1.1 KV grade of following size in the existing “GI pipe/SW pipe/PVC pipe” or in the existing trench or on surface or in the existing cable tray etc. as reqd.a) 3 x 10 sqmm
22532 Amps. TP MCB C series with suitable HP fully automatic star delta starter with over load protection,single phase preventor complete with all accessories and internal wiringrequired for manual operation, selector switch for local /remote,auto/manual/off operation with LED type indication lights to mark ON-OFF position of pumps :- 2 Sets
226Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as requiredb) 3 - 1/2 x 25 sq mm (28mm).
227Supplying and laying control wiring with multicore copper standard conductor of following sizes PVC insulated , PVC sheathed armoured under ground cable between various pressure switch and system controller / starter etc. on surface / existing cable tray /existing pipe complete with connections at both end with glands etc. as requireda) 2 x 1.5 sq mm
228Supplying, installation, testing & commissioning0-10 Kg/cm2 ON/OFF pressure switch ofpressure range as per CPWD specification in delivery line of pump alongwith control wiring for auto starting & auto stopping of terrace fire pump complete with all necessary accessories etc. as reqd.
229Supply ,fixing ,testing and commissioning of butterfly valve PN 1.6 (gear), with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets, conforming to IS 13095/ relevant IS with upto date ammendments of following sizes as reqd.a) 100 mm dia
230Providing, installation, testing and commissioning of dual plate non - return valve of following sizescomplete with rubber gasket ,GI bolts,Nuts and washer etc. as reqd.a) 100 mm dia
231Supply and fixing63 mm 2 way FBC of CI body with 2 no. brass gunmetal male instantaneous inlet couplings complete with cap and chain as reqd. for 100 mm dia M.S. pipe connection conforming to IS: 904 alongwith MS enclosure not less than 0.9m x 0.75m x 0.6 m fabricated from 1.6 mm thick sheet steel with full glass on front side to accomodate the same including painting with red colour as reqd.The box should be mounted on suitable raised platform of brick masonary work.
232Supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangment with 25 mm dia Gun Metal wheel valve with required acessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
233Supplying Installation Testing & Commissioning of 150 mm dia bourdan type stainless steel dial presure gange having celibration of (0-16) Kg/Sq Cm complete etc as reqd. (Melig HGGRU / Flebeg)
234SITC of CI body flange type servicable suction / POT strainer with (S.S/Brass Merch) confirm to revelant to IS specification up to date complete with fixing nut bolts, washer, garker etc complete as reqd. (Hammer / sant / Kartor/ Leadermake)a) 100 mm dia
235Pdg. laying testing & commissioning of "C" class heavy duty MS pipe conforming to IS 1239/3589 (which ever is applicable) i/c fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. fixing the pipe on the wall / ceiling/floor with suitable clamps or any suitable arrangement as per site condition and painting with two of morecoats of synthetic enamel paint of reqd. shade complete as reqd.a) 100 mm dia
236Pdg. laying testing & commissioning of "C" class heavy duty MS pipe conforming to IS 1239/3589 (which ever is applicable) i/c fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. fixing the pipe on the wall / ceiling/floor with suitable clamps or any suitable arrangement as per site condition and painting with two of morecoats of synthetic enamel paint of reqd. shade complete as reqdb) 25 mm dia
237Supply and fixing first - aid hose reel with MS construction spray painted in post office red, conforming to IS 884 with upto date amendments, complete with the following as reqd.(a) 30 m. long 20mm, (nominal internal) dia water hose thermoplastic ( Textile reinforced) type - 2 as per IS: 12585(b) 25 mm (nominal internal) dia gun metal globe valve & nozzle.c) Drum and brackets for fixing the equipments on wall.d) Connections from riserwith 25mm dia. Stop valve (Gun Metal and MS pipe)
238Supply and fixing single headed yard hydrant valve with 1 no. 63 mm. dia instantaneous FM Gun metal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank gunmetal cap and chain as reqd.
239Supply and fixing63 mm. dia , 15 mtr. Long RRL hose pipe with 63 mm. dia male and female Gun metal couplings duly binded with GI wire , rivets etc. confirming to IS 636 ( type A) as reqd.
240Supply and fixingof hose cabinet of size 750mm x 600 mm x 250mm made of 1.6 mm thick MS sheet with 6 mm thick (nominal) glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 no. 15 mtr. Long hose pipe, 1no. Branch pipe.,mounted on wall OR raised brick platform & duly painted with post office red externally and white internally synthetic enamel paint complete in all respect for external hydrant as reqd.
241Supplying and fixing 63 mm dia gunmetal branch pipe with 20mm (nominal internal diameter) size gun metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as reqd.
242Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class "A", B & "C" that is wood, textile, flammable liquid, electric and gases.a) 06.0 kg capacity
243ISI marked (IS: 2878) Portable Fire Extinguisher, Carbon oxide type flat base including valve, discharge hose of not less than 10mm dia. 1m long and complete in all respect including initial fill with CO2 gas conforming to IS: 307-1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket. a) 04.5 kg capacity
244Supplying, Installation of following size plastic body exhaust fan with inbuilt louvers in the existing opening, including making hole to suit the size of the above fan, making good the damages, connection, testing, commissioning etc. as required. 200 mm Exhaust fan (Light duty)
245Supplying, Installation, testing and commissioning of 18 watt LED wall mountingenergy efficient box type luminare with 18 watt LED tube suitable for 230 volts,50 Hz AC supplywiringwith 1.5 sq.mm. FRLS PVC insulated copper conductor, single core cable and earthing etc. as reqd. (Make :Bajaj - BLRB-DB 118or similar to Wipro/CG/Havells)
246Supplying and fixing 1 x 15 watt Retrofit CFL decorative wall mounted luminaire made up of polycarbonate unbreakable covercluding 1No. 5 watt retrofit LED lamp complete with connection testing and commissioning etc.as required( Make: Havell"s model No.City 2 or equivalent make of Philips/Bajaj)
247SITC surface mounting 6 watt LED downlight for soft diffused light fittingsof round sleek surface lighting in powder coated white finish with integrated electronic driveri/c connection with 1.5 sq.mm. FRLS PVC insulated, copper conductor single core cable etc. and suitable for 230 V ,50 HZ etc as required.(Make : Bajaj - BGSLO Sleek Surface 06W WH RD or similar make of Havell"s/Philips/Wipro)
248Supplying, Installation, testing and commissioning of 9 watt LED wall mountingenergy efficient mirror light fitting with 9 watt LED tube suitable for 230 volts,50 Hz AC supplywiringwith 1.5 sq.mm. FRLS PVC insulated copper conductor, single core cable and earthing etc. as reqd. (Make :Havell"s cat.no.LheXArP7Pn1W009 or similar to Bajaj/CG/Philips)
249SITC of 10wattLED Bulkhead fitting withwithspecially designed gasket i/c built in LED lampconnection with 1.5 sq.mm FRLS PVC insulated copper conductor cable as required.( Make: Bajaj cat. No. BIBWP 10W LED or equivalent make of Philips/Wipro/Crompton)
250F.S.I.T.C of wall mounted totally enclosed cubical panel of of depth not less than 300 mm made of 1.6 mm thick M.S sheet for frame and 2mm thick MS sheet for base duly stiffening by angle iron frame of size 25mm x 25mm x 3mm thick compartmentalised having hinged type front door locking arrangement with panel key and providing and fixing 200 Amps capacity 4 strips aluminium busbar of suitable length including bakelite insulator and having provision for fixing switchgear, meter, MCB etc.including earth stud gasket,rubber bush,clear glass for meter reading interconnecting copper cable etc. and duly painted with two coats of enamelled paint after applying two coats of anticorrosive metal primer and 35mm x 5mm flat iron welded in the four corner for installation and providing and fixing following switch gears in it etc. as required. (For 16 Nos T-II qtrs ( Size of panel-- 1300mm x 1200mm x 300mm deep)(ii) Incoming:(i) 100 Amps 4P 18KA MCBB --- 1No.(ii) Bus Bar(a) 4 strip Aluminium 200Amps rating(iii) Outgoing:(a) 40 Amps DP MCB--- 16Nos.(b) (5-30) Amps Single phase Electronic meter with counter display---
251Supply of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS-7098 (part-I)/1988 with ammendment up to date etc as required. 3½ X 70sq. mm 1.1 Kv grade AL conductor armoured UG cable
252Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
253Supply,loading,unloading at site as well as installation,testing and commissioning of OUT DOOR STREET LIGHTING PANEL made by16 SWG CRCA sheet enclosureincluding cutting, bending, drilling, welding and riveting completeand cleaning with 7-tank process and painting (shade RAL 7032 Siemens Grey)with powder coating IP- 54 protection, along withnecessary accessories of panel , cable entry compartments, cubus bar interconnections with suitablecopper flexible cableas per requirement etcincluding all Labour ,cost ,conveyance of materials,taxes etc complete.INCOMER63A 4P MCB 10 KA- 1 No with timer 1NO- day delay timer with power contactorindication lamp set-1noOUTGOINGS25 A 4P MCB 10 KA- 8NO"SPanel described as above
254Supplying and fixing Cable3.5 x 25 sq.mm
255Fabrication,transportation,supply and fixing of 4.5 Mtrs longGI galvonized octagonal poles with 3mm thick HT steel plate with a bottom 175mm dia and top 75mm dia, base plate of size 160mmx160mmx16mm thick welded to bottom of pole, terminal box is inside pole with all accessories connector and fuse base and including excavation of pit(156 Cmx 60Cmx60cm), rcc foundation(C.C.work for pit 1:3:6),. foundation bolts with washers and nuts 4 sets. including S&F of 1.5mtrs sword type decorative single arm bracket with dooms either sides complete with all accessories as per the requirements at site and as per the directions of field engineers during execution for finished item of work.
256Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of BAJAJ Make Light Fixture Cat. No- BGWRL 150SV FFGor equivalent internally prewired with 3 x 2.5 sq.mm PVC insulated "Cu" wires and complete with 50 Wwatt LED Street Light and integral control gear, suitable M.S.Clamp, nut, bolt etc. complete as required. etc.
257Supply of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS-7098 (part-I)/1988 with ammendment up to date etc as required. 3½ X 70sq. mm 1.1 Kv grade AL conductor armoured UG cable