Replacement Of Existing Lt Line By L.T A.B. Cable & Supply Of Its Associated Decentralised Material Under Edd Kashipur Under Edc Kashipur=2 Supply Of Stay Clamp For Pcc Pole Made Of M.S. Flate Size 50X6 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole F, kashipur-Uttarakhand

Uttarakhand Power Corporation Limited has published Replacement Of Existing Lt Line By L.T A.B. Cable & Supply Of Its Associated Decentralised Material Under Edd Kashipur Under Edc Kashipur=2 Supply Of Stay Clamp For Pcc Pole Made Of M.S. Flate Size 50X6 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole F. Submission Date for this Tender is 07-04-2022. Bolts Tenders in kashipur Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

31614639
Corrigendum : Replacement Of Existing Lt Line By L.T A.B. Cable & Supply Of Its Associated Decentralised Material Under Edd Kashipur Under Edc Kashipur=2 Supply Of Stay Clamp For Pcc Pole Made Of M.S. Flate Size 50X6 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole F
Tender
Indian
Uttarakhand
Kashipur
07-04-2022

Tender Details

Replacement Of Existing Lt Line By L.T A.B. Cable & Supply Of Its Associated Decentralised Material Under Edd Kashipur Under Edc Kashipur=2 Supply Of Stay Clamp For Pcc Pole Made Of M.S. Flate Size 50X6 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole For 65X16 Mm Nut And Bolts And Washer Without Cracks & Burrs. ( As Per Specification & Drawing Of Upcl ) 3 Supply Of M.S. Half Clamp For Pcc Pole Made Of M.S. Flate Size 35X5 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole For 65X16 Mm Nut And Bolts And Washer Without Cracks & Burrs For Fixing Of Lt Distribution Box. ( As Per Specification & Drawing Of Upcl ) 4 Supply Of M.S Clamp For Pcc Pole Made Of M.S. Flate Size 50X6 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole For 65X16 Mm Nut And Bolts And Washer Without Cracks & Burrs For Dead End Clamp. ( As Per Specification & Drawing Of Upcl ) 5 Supply Of M.S Clamp For Pcc Pole Made Of M.S. Flate Size 50X6 Mm Duly Red Oxide Painted With Fitted 18M Dia Hole For 65X16 Mm Nut And Bolts And Washer Without Cracks & Burrs For Suspension Clamp. ( As Per Specification & Drawing Of Upcl ) 6 Supply Of Smc Three Phase L.T. Distribution Box For Connection Of Lt Consumer With In Built Panel Lock With Key, Al Bus Bar Ryb 25X6 Mm & Al Bus Bar N 40X6mm. Make- ( Sintex / Other Is Complied Reputed Company ) 7 Supply Of Shear Head Type Insulated Piercing Connector Body Moulded From High Quality Mechanical Climate And Uv Resistant Glass Reinforced Polyamide Hot Dipped Galvanized Bolts & Contact Teeth Abc Size 120 Sq Mm To 120 Sq Mm / 95 Sq Mm. Make- ( Tyco / Rpg / 3M / Sicame / Ensto ) 8 Supply Of Shear Head Type Insulated Piercing Connector Body Moulded From High Quality Mechanical Climate And Uv Resistant Glass Reinforced Polyamide Hot Dipped Galvanized Bolts & Contact Teeth Abc Size 120 Sq Mm To 120 Sq Mm / 95 Sq Mm. Make- ( Tyco / Rpg / 3M / Sicame / Ensto ) 9 Supply Of Dead End Clamps With I Hook. ( As Per Specification & Drawing Of Upcl ) 10 Supply Of Suspension Clamps With I Hook. ( As Per Specification & Drawing Of Upcl ) 11 Supply Of L.T. Bare Neutralconnectors Pg Clamp 95 Sq Mm To 25 Sq Mm. ( As Per Specification & Drawing Of Upcl ) 12 Supply Of L.T. Bare Neutralconnectors Pg Clamp 95 Sq Mm To 95 Sq Mm. ( As Per Specification & Drawing Of Upcl ) 13 Supply Of Aluminum Lugs O Type Size 25 Mm For Connecting Pvc Cable 4X25 Sq Mm. ( As Per Specification & Drawing Of Upcl ) 14 Supply Of Aluminium Lug Size 120 Sq Mm Made Of Best Quality Pore Line And Without Defeets Isi Standerd. ( As Per Specification & Drawing Of Upcl ) 15 Aerial Bunch Cable Laying Work 16 Cartage Of Pcc Poleby Private Truck From Store Centre Rudrapur / Haldwani / Kashipur To Work Site Dump Store Approx. Distance 10 To 80 Km. Including Loading Into Truck And Unloading At Work Site. Dump Store And Carriage From Dump Store To Pit Site. 17 Cartage Of Small Line Material By Private Truck From Store Centre Rudrapur / Haldwani / Kashipur To Work Site Dump Store Approx. Distance 10 To 80 Km. Including Loading Into Truck And Unloading At Work Site. Dump Store And Carriage From Dump Store To Pit Site. 18 Erection Of Pcc Pole After Digging Of Pit Size 0.6×0.6 Mtrs & 1 / 6 Length Of Support On 300×300×75 Mm Stone Pad Including Fixing With All Accessories Complete In All Respect As Per Specification Of Upcl. 19 Fixing Of Grouting Of Stay Set Complete As Per Respo Drawing No. Res-16 With Stay Rod 16×1800 Mm Stay Wire 7 / 10 Swg Including Excavation Of Earth And Grouting Of Stay In Pit With Cc 1:4:8 In Bottom Of Pit In Size 0.60×0.60×0.60 Mtrs, Including Cost Of Cement, Sand And Stone Ballast Etc. Fixing Of All Accessories Complete In All Respect As Per Specification Of Upcl. 20 Labour Charges For Single Phase Of Disconnection & Re-Connection Offollowing L.T.Consumer Service Connection.& Shiffting Of Energy Meter From Consumer Premises As Per Norms Of Upcl To Outside Of Premises, Replacement Of Defective Meter, Mechenical Meter To Electronic Meter & Other Related Work With Writing Of Consumer Number On The Respective Distribution Box Etc. 21 Labour Charges For Three Phase Of Disconnection & Re-Connection Offollowing L.T.Consumer Service Connection.& Shiffting Of Energy Meter From Consumer Premises As Per Norms Of Upcl To Outside Of Premises, Replacement Of Defective Meter, Mechenical Meter To Electronic Meter & Other Related Work With Writing Of Consumer Number On The Respective Distribution Box Etc. 22 Fixing Of M.S. Earthing Rod 20×2500 Mm For Earthing Of Support As Per Respo Drawing No. Res-12 Including Digging Earth Rod 2.5 M Deep Below Ground Level Connected To Support With Earth Wire 7 / 16 Swg Fixing Of All Accessories Complete In All Respect As Per Specification Of Upcl. 23 Dismantling Of Old Acsr Conductor From Existing Lt Line Including Re- Rolling Back Its Conductor, Wire, Clamp, Insulator, Any Other Wire Or Items Etc.Including Stacking And Transportation Of Material To The Upcl Central Stores 2-40 Km. 24 3 Phase 4 Wire 25 2 Phase 3 Wire 26 1 Phase 2 Wire 27 Laying, Stringing And Sagging Of Lt A.B Cable Size ( 3X120+1X95 ) Including Fixing Of Insulated Piercing Connector, Dead End Clamps With I Hook, Suspention Clamp, Holding Clamps, Etc. Complete In All Respect As Per Specification Of Upcl. 28 Laying And Fixing Insulated Cable 4X25 Sq Mm Insulated Lead. ( Cable Provided By Upcl ) 29 Fixing Of L.T. Distribution Box & Connection Of Respective Consumer In All Respect. 30 Fixing Of Dead End Clamp 31 Fixing Of Suspension Clamp 32 Fixing Of Shear Head Type Insulated Piercing Connector For Line To Line Taping 120 / 95Sq Mm To 120 / 95 Sq Mm 33 Fixing Of Shear Head Type Insulated Piercing Connector For Line To Box Taping 120 / 95Sq Mm To 25 / 16 Sq Mm 34 Fixing Of L.T. Bare Neutralconnectors Pg Clamp Line To Line95 / 70 Sq Mm To 95 / 70 Sq Mm. 35 Fixing Of L.T. Bare Neutralconnectors Pg Clamp Line To Line95 / 70 Sq Mm To 25 / 16 Sq Mm.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 31-03-2022 work and performance Technical Bid 07-04-2022

Key Value

Document Fees
INR 1180 /-
EMD
INR 72000.0 /-
Tender Value
Refer document