| 1 | Items List |
| 2 | Acid resistant tiles 38 mm thick:Providing and fixing of Acid resistant tiles of 38 mm thickby applying one coat of acid resisting epoxy primer, over it cold epoxy screed plaster lining- 3mm, placing acid resistance tiles of 38 mm thick usingpotassium silicate bedding mortar- 6mm thickness, pointing the joints using furane filling mortar all complete as per site conditions, including manpower, tools, tackles, materials, scaffolding, transportation to site etc., all complete as directed by Engineer-In-Charge (EIC). |
| 3 | Dismantling tiles:DISMANTLING TILE WORK IN FLOORS, WALLS AND ROOFS LAID IN CEMENT MORTAR INCLUDING STACKING MATERIAL WITHIN 50 METERS LEAD FOR THICKNESS OF TILES 10MM TO 25 MM |
| 4 | PCC below plinth 1:2:4:Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) in all works up to plinth level including pumping out of water wherever necessary. |
| 5 | 12 mm thick cement plaster:12 mm thick cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand) |
| 6 | Dismantling RCC:DISMANTLING R.C.C. WORK MANUALLY/ BY MECHANICAL MEANS INCLUDING STACKING OF STEEL BARS AND DISPOSAL OF UNSERVICEABLE MATERIAL WITHIN 50 METERS LEAD AS PER DIRECTION OF ENGINEER-IN-CHARGE. |
| 7 | RCC M25 below plinth:PROVIDING AND LAYING IN POSITION REINFORCED CEMENT CONCRETE OF DESIGN MIX M25 WITH OPC CEMENT @ 340 KGS, WITH 20MM AND DOWN SIZE GRADED GRANITE METAL COARSE AGGREGATE @ 0.70CUM AND FINE AGGREGATE @ 0.47CUM, WITH SUPERPLASTISISER @ 3LTS CONFIRMING TO IS 9103-199 REAFFIRMED -208, MACHINE MIXED, CONCRETE LAID IN LAYERS NOT EXCEEDING 15 CMS THICK, VIBRATED FOR ALL WORKS IN FOUNDATION FOR FOOTINGS, PEDESTALS, RETAINING WALLS, RETURN WALLS, WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, COLUMNS PILLARS, POSTS, STRUTS, BUTTRESSES, BED BLOCKS, ANCHOR BLOCKS & PLINTH ETC., INCLUDING COST OF ALL MATERIALS , LABOURS, HOM OF MACHINERY, CURING, COMPLETE AS PER SPECIFICATIONS AND THE DIRECTIONS OF EIC. |
| 8 | Centering & Shuttering:CENTERING AND SHUTTERING INCLUDING STRUTTING, PROPPING ETC. AND REMOVAL OF FORMWORK FOR FOUNDATIONS, FOOTINGS, WALLS, SUSPENDED FLOORS,ROOFS, LANDINGS, SHELVES, LINTELS, BEAMS, COLUMNS, STAIRS, ETC.,COMPLETE AS DIRECTED. |
| 9 | Reinforcement Steel:REINFORCEMENT FOR R.C.C. WORK USING THERMO-MECHANICALLY TREATED (TMT) BARS, HYSD BARS, MILD STEEL BARS OF DIAMETER 6MM TO 32MM, INCLUDING STRAIGHTENING, CUTTING, BENDING, PLACING IN POSITION AND BINDING ALL COMPLETE AS DIRECTED. |
| 10 | P/L mortar including cleaning surface:PROVIDING AND APLLYING A LAYER OF POLYMER MODIFIED MORTOR ON EXPOSED CONCRETE SURFACE OF AVERAGE THICKNESS OF 20 MM AND FINISHED IN FLUSH WITH THE ADJACENT CONCRETE SURFACE & CUREDAS PER MANUFACTURERS SPECIFICATION AND AS DIRECTED BY EIC INCLUDING REMOVAL OF LOOSE CONCRETE USING WIRE BRUSH, NEUTRALIZE THE PIT BY FRESH WATER JET TILL THE REMOVAL OF SULPHUR FROM THE CONCRETE WALL. RATE INCLUSIVE OF MATERIAL, LABOURS, EQUIPMENT HIRE CHARGE, TOOLS AND TACKLES ETC., COMPLETE. |
| 11 | Protective Coating for Concrete Surface:Supply and application of MasterSeal 7000 CR or equivalent (Based on Xolutec technology with different compostion depending on site conditions and requirements) for water proofing and protective coating, including prepration of concrete surface by water jet wash to remove any contaminations and filling with epoxy or equivalent to rebuild and maintain geometry of the surface as per enclosed specification and as directed by EIC. |
| 12 | 2mm FRP with GP Resin:SUPPLY AND LAYING OF 2 MM FIBRE REINFORCED PLASTIC (FRP) WITH GENERAL PURPOSE GLASS AND RESIN INCLUDING PRIMER AS PER TENDER AND INSTRUCTIONS OF EIC |
| 13 | Tiles joint filling:Supply and applying of tiles joint filling by using furane resin filling mortar including all material, labour cost etc. complete as direcetd by EIC. |
| 14 | 18mm Cement Plaster:18 MM THICK CEMENT PLASTER IN TWO COATS OF UNDER LAYER 12 MM THICK CEMENT PLASTER 1:5 (1 CEMENT: 5 COARSE SAND) FINISHED WITH A TOP LAYER OF 6MMTHICK CEMENT PLASTER 1:6 (1 CEMENT : 6 FINE SAND) |
| 15 | Supply of PPG lining:Supply ofthermoplastic chemical resistant PPG of 3.5 MM thick where 2 MM will be the sheet and 1.5 MM aproxis theadhesive flooring & lining havingtensile strength at yeild not less than 37.59 N/mm2,Elongation yield- 25.2%,Flexural Modulus- 1522.5 N/mm2 and Acid and alkaline resistance from PH value 2 to 14 and as per enclosed specification and as directed by EIC. |
| 16 | Laying of PPG lining:Laying ofthermoplastic chemical resistant PPG for 3.5 MM thick where 2 MM will be the sheet and 1.5 MM aproxis theadhesive flooring & lining including removal of the exisiting lining, joining/ welding etc all complete as per enclosed specification and directed by EIC. |
| 17 | Grouting:DRILLING HOLES AND FIXING HOSES AND PRESSURE GROUTING THE CEMENT SLURRY ADDED WITH CONBEX 100 AS PER THE SPECIFICATION INCLUDING MANPOWER, TOOLS, TACKLES, ETC., AS DIRECTED BY EIC. |