| Sl. No. | Item Description |
| 1 | (A) SH: Academic Block-School Building :Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3m |
| 2 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 3 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 5 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : b) Walls including attached buttresses, pilasters and their caps andbases and string courses etc. up to floor two level. |
| 6 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 7 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to |
| 8 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface. |
| 9 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 10 | b) Column Pillars Struts. |
| 11 | c)Lintels, beams, girders, bressumers and cantilevers etc. |
| 12 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel. |
| 13 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand). |
| 14 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level |
| 15 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
| 16 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 17 | Providing approved best available local wood (Class B-II) work in frames of doors, windows, clerestory window and other frames, wrought framed and fixed in position. |
| 18 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 19 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a)38 mm thick best available local wood, class - B I |
| 20 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal |
| 21 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a)Ornamental Grill. |
| 22 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc completea) 300 x 16 mm |
| 23 | b) 250 x 16 mm |
| 24 | Providing and fixing aluminum Tower bolts anodized or transparent or dyedto required color or shade with necessaryscrews etc complete.a) 150 x 10 mm |
| 25 | b) 100 x 10 mm |
| 26 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)100 mm |
| 27 | b)75 mm |
| 28 | Providing and fixing M.S. hooks and Eyes(a) 150 mm. |
| 29 | Providing and fixing 2.50 cm thick approved local wood eaves boards 23 cm wide with necessary mouldings etc. |
| 30 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 31 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete( welding to be paid separately). |
| 32 | Welding by gas plant |
| 33 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.a) 50 mm thick |
| 34 | Providing and fixing Durashine Zink Aluminium alloy coated (TATA Bloescope building product) sheet roofing fixed with necessary fasterners and laping method as discribed by the manufacturer inclusive of cutting hoisting and fixing complete excluding the cost of purlin rafters & truss. |
| 35 | Providing and fixing Durashine Zink Aluminium alloy coated (TATA Bloescope building product) ridge roofing fixed with necessary fasterners and laping method as discribed by the manufacturer inclusive of cutting hoisting and fixing complete excluding the cost of purlin rafters & truss. |
| 36 | Providing and fixing 20 mm thick wooden planks ceiling (frame work for base to be paid separately) with M.S. screws.b) Timber Plank Class - B I |
| 37 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 38 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand). On the rought side of singleor half brick |
| 39 | Applying one coat of cement primer of approved brand and manufacture onwall surface. |
| 40 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 41 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 42 | White washing with lime on new work (two or more coats) to give an evenshade. |
| 43 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 44 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 45 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 46 | Painting two or more coats (excluding priming coat) with superior readymixed paint for steel work of approved brand and manufacture in all shadeson new work to give an even shade. |
| 47 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 48 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a)15mm nominal bore. |
| 49 | b)20mm nominal bore. |
| 50 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 20 mm nominal bore |
| 51 | Providing and fixing brass bib cock of approved quality.a) 15mm nominal bore. |
| 52 | Providing and fixing brass stop cock of approved quality.a) 20 mm nominal bore |
| 53 | Providing and fixing PVC connection pipe with brass union 30cm length.a) 15mm nominal bore. |
| 54 | b)20mm nominal bore. |
| 55 | Painting G.I. pipes and fittings with white paint over a coat of ready mixed priming coat both of approved quality for new work.a) 15 mm dia pipe |
| 56 | b) 20mm dia pipe |
| 57 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvan.a) Long Pan patten WC Pan |
| 58 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 59 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 60 | Providing and fixing rubber plug for sink or wash basin. |
| 61 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 50 mm dia |
| 62 | b) 100 mm dia |
| 63 | Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia |
| 64 | a) 50 mm dia |
| 65 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 66 | Providing and fixing local wooden railing 0.75 m high with 7.5 x 5 cm top and bottom rails 7.5 x 5 cm sides and 5 cm x 5 cm intermediate vertical bars placed at 22.5 cm centre to centre including painting two or more coats as directed |
| 67 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth |
| 68 | SH: A-I- SEPTIC TANK : Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 69 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 70 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 71 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 72 | Reinforcement of RCC work including bending, binding and placing in position complete.a)Mild Steel. |
| 73 | Centring and shuttering including strutting, propping etc. and removal of form work for:a)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 74 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 75 | 12 mm thick cement plaster 1:3( 1 cement : 3 fine sand) |
| 76 | Neat cement punning |
| 77 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40 mm thick. |
| 78 | SH: A-II- Carriage of Materials |
| 79 | SH: A-III- ELECTRICATION : Point wiring in PVC conduit, with modular type switch. Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required.Group A |
| 80 | Group B |
| 81 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 82 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug). |
| 83 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 84 | 25 mm |
| 85 | S/F modular type switch/socket :-Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 Amps Switch |
| 86 | 15/16 Amps Switch |
| 87 | 5/6 Amps Socket |
| 88 | 15/16 Amps socket outlet |
| 89 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 90 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 91 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 92 | Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 93 | Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.5/6 amps switch |
| 94 | Installation, testing and commissioning of resistance type ceiling fan regulator,in existing switch box including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,earthing the regulator etc. as required. |
| 95 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.510 mm sweep |
| 96 | MCCB, MCB & DB’S : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP&N |
| 97 | 63 Amp TP&N |
| 98 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp |
| 99 | 125 Amp |
| 100 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 101 | FittingsSupplying of 1200mm AC sweep ceiling Fan( Orient/Usha make) |
| 102 | Modular fan regulator ( anchor/Roma step make) |
| 103 | 20 Wats LED Bulbs ( bajaj/ Phylips make) |
| 104 | 15 Wats LED Bulbs ( bajaj/ Phylips make) |
| 105 | Fluorescent Tube set fitting/ ( bajaj/ Phylips make) |
| 106 | Exhaust fan |
| 107 | Fire Extinguisher |
| 108 | SH: A-IV - FURNITURE :WoodenDesk.- 2\"x1\"10\"x2\"6\" |
| 109 | Wooden Bench.-2\"x9\"x2\" |
| 110 | Water Filter (20 Ltr) |
| 111 | Dustbin |
| 112 | WoodenDesk.- 2\"x1\"10\"x2\"6\" |
| 113 | Wooden Bench.-2\"x9\"x2\" |
| 114 | Water Filter (20 Ltr) |
| 115 | Dustbin |
| 116 | Sciene Laboratory Equipment |
| 117 | SH: B-I-100 Bedded Girls Hostel BuildingEarth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3m |
| 118 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 119 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 120 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 121 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : b) Walls including attached buttresses, pilasters and their caps andbases and string courses etc. up to floor two level. |
| 122 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 123 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to |
| 124 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface. |
| 125 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 126 | Centring and shuttering including strutting, propping etc and removal of form work for :a)Foundation, footings, bases of columns etc. and mass concrete. |
| 127 | b) Column Pillars Struts. |
| 128 | c)Lintels, beams, girders, bressumers and cantilevers etc. |
| 129 | f) Stairs (excluding landings) except spiral stair cases. |
| 130 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel. |
| 131 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 132 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level |
| 133 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
| 134 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 135 | Providing approved best available local wood (Class B-II) work in frames of doors, windows, clerestory window and other frames, wrought framed and fixed in position. |
| 136 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 137 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a)38 mm thick best available local wood, class - B I |
| 138 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal |
| 139 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a)Ornamental Grill. |
| 140 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a)100 mm |
| 141 | b)75 mm |
| 142 | Providing and fixing M.S. hooks and Eyes(a) 150 mm. |
| 143 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 144 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete( welding to be paid separately). |
| 145 | Welding by gas plant |
| 146 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.a) 50 mm thick |
| 147 | Providing and fixing Dyana Roofing |
| 148 | Providing ridges or hips 60cm over al lin plain G.I.sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia.G.I.limpet and bitumen washers complete. |
| 149 | Providing and fixing 20 mm thick wooden planks ceiling (frame work for base to be paid separately) with M.S. screws.b) Timber Plank Class - B I |
| 150 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand). On the rought side of singleor half brick |
| 151 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). On the rought side of singleor half brick |
| 152 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 153 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 154 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 155 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 156 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 157 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a)15mm nominal bore. |
| 158 | b)20mm nominal bore. |
| 159 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 20 mm nominal bore |
| 160 | Providing and fixing brass bib cock of approved quality.a) 15mm nominal bore. |
| 161 | Providing and fixing brass stop cock of approved quality.a) 20 mm nominal bore |
| 162 | Providing and fixing PVC connection pipe with brass union 30cm length.a) 15mm nominal bore. |
| 163 | b)20mm nominal bore. |
| 164 | Painting G.I. pipes and fittings with white paint over a coat of ready mixed priming coat both of approved quality for new work.a) 15 mm dia pipe |
| 165 | b) 20mm dia pipe |
| 166 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvan.a) Long Pan patten WC Pan |
| 167 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 168 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 169 | Providing and fixing rubber plug for sink or wash basin. |
| 170 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 50 mm dia |
| 171 | b) 100 mm dia |
| 172 | Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia |
| 173 | a) 50 mm dia |
| 174 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 175 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm |
| 176 | Providing and fixing local wooden railing 0.75 m high with 7.5 x 5 cm top and bottom rails 7.5 x 5 cm sides and 5 cm x 5 cm intermediate vertical bars placed at 22.5 cm centre to centre including painting two or more coats as directed |
| 177 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth |
| 178 | SH: B-II- SEPTIC TANK : Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 179 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 180 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 181 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 182 | Reinforcement of RCC work including bending, binding and placing in position complete.a)Mild Steel. |
| 183 | Centring and shuttering including strutting, propping etc. and removal of form work for:a)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 184 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 185 | 12 mm thick cement plaster 1:3( 1 cement : 3 fine sand) |
| 186 | Neat cement punning |
| 187 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. a) 40 mm thick. |
| 188 | SH : B-II- Carriage of Materials |
| 189 | SH: B-III- ELECTRIFICATION:Point wiring in PVC conduit, with modular type switch. Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required.Group A |
| 190 | Group B |
| 191 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 192 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug). |
| 193 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 194 | 25 mm |
| 195 | S/F modular type switch/socket :-Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 Amps Switch |
| 196 | 15/16 Amps Switch |
| 197 | 5/6 Amps Socket |
| 198 | 15/16 Amps socket outlet |
| 199 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 200 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 201 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 202 | Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 203 | Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.5/6 amps switch |
| 204 | Installation, testing and commissioning of resistance type ceiling fan regulator,in existing switch box including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,earthing the regulator etc. as required. |
| 205 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.510 mm sweep |
| 206 | MCCB, MCB & DB’S : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP&N |
| 207 | 63 Amp TP&N |
| 208 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp |
| 209 | 125 Amp |
| 210 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 211 | FittingsSupplying of 1200mm AC sweep ceiling Fan( Orient/Usha make) |
| 212 | Modular fan regulator ( anchor/Roma step make) |
| 213 | 20 Wats LED Bulbs ( bajaj/ Phylips make) |
| 214 | 15 Wats LED Bulbs ( bajaj/ Phylips make) |
| 215 | Fluorescent Tube set fitting/ ( bajaj/ Phylips make) |
| 216 | Exhaust fan |
| 217 | Fire Extinguisher |
| 218 | SH: B-IV- FURNITURE : WoodenDesk.- 2\"x1\"10\"x2\"6\" |
| 219 | Wooden Bench.-2\"x9\"x2\" |
| 220 | Water Filter (20 Ltr) |
| 221 | Dustbin |
| 222 | Wooden Bed |
| 223 | Wooden Writing Table.(Small size)-2\"x4\"x2\"6\" |
| 224 | Wooden Arm Chair-1\"6\"x1\"6\"x1\"5\" |
| 225 | Dustbin |
| 226 | SH: C: BOUNDARY WALL : Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 227 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 228 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 229 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 230 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm toa) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 231 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surfaca) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 232 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 233 | b) Column, pillars, posts and struts etc. |
| 234 | c) Beam , linteletc. |
| 235 | Reinforcement of RCC work including bending, binding and placing in position complete.a) TMT steel |
| 236 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand). |
| 237 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 238 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 239 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 240 | 15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 241 | Providing and fixing MS grills of required patternwith MS flat, square or round bars with round headed bolts and nuts or by screws.a) Ornamental grill. |
| 242 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 243 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 244 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |