Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually / by mechanical means including disposal of material within all leads and lifts as per direction of Engineer-in-charge Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). |
| 2 | Demolishing brick work manually / by mechanical means including stacking of serviceable material at specified space and disposal of unserviceable material within all leads and lifts as per direction of Engineer-in-charge. |
| 3 | Demolishing dressed stone masonry in cement mortar manually / by mechanical means including stacking of serviceable material at specified places and disposal of unserviceable material within all lead and lifts as per direction of Engineer-in-charge. |
| 4 | Demolishing rubblestone masonary in cement mortar manually / by mechanical means including stacking of serviceable material at specified places and disposal of unserviceable material within all lead and lift as per direction of Engineer-in-charge. |
| 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within all leads and lifts including carriage of materials within all leads and lifts. |
| 6 | Dismantlingfencing with posts or struts including dismantling of all earth work and concrete etc. including stacking the fencing at specified place and disposal of unserviceable materials within all leads and lifts as directed by the Engineer-in-charge. |
| 7 | Excavation in soil in Hilly area by manual / mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lifts as per drawing and Technical Specification Clause 1603.1 including saturated soil comprising of pick work, jumper work, and blasting work both in soft and hard rock with chiselingand wedging out of rock (where blasting is prohibited) andtheir intermediate classificationof soilsincluding, dewatering wherever required, settingout to required lines,levels as shown on the drawing and as directed by the Engineer -in-Charge at site and sorting out useful and un- useful material and transportation of the un -useful material for disposing at approved dumping site or otherwise and including payment of prescribed charges of dumping to the owner of dumping site (to be arranged by the contractor) for the satisfaction of Engineer- in -Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools equipments and safety measures and other incidentals necessary to complete the work by mechanical means and labour (if required) the useful stone which is likely to be obtained from cutting / dismantling of random rubble masonryi.e. 452.83 cum @ 300/-cum, 214.33cum @ 500/-cum and 53.82cum@Rs. 1000 per cum will be recovered on.Any loss to the public and private property during the course of execution and disposal of serviceable and unserviceable materials shall be the absolute responsibility of the contractor and shall have to be duly compensated by him in all respects including all incidental charges. |
| 8 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto all leads and lifts and dressing of sides and bottom and backfilling in trenches with excavated suitable material including saturated soil comprising of pick work, jumper work, and blasting work both in soft and hard rock with chisellingand wedging out of rock (where blasting is prohibited) andtheir intermediate classificationof soilsincluding, dewatering wherever required, settingout to required lines,levels as shown on the drawing and as directed by the Engineer-in-Charge at site and sorting out useful and un- useful material and transportation of the un-useful material for disposing at approved dumping site or otherwise and including payment of prescribed charges of dumping to the owner of dumping site (to be arranged by the contractor) for the satisfaction of Engineer- in -Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour, machineries, tools equipments and safety measures and other incidentals necessary to complete the work by mechanical means and labour (if required).Any loss to the public and private property during the course of execution and disposal of serviceable and unserviceable materials shall be the absolute responsibility of the contractor and shall have to be duly compensated by him in all respects including all incidental charges. |
| 9 | Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30mm x 30mm x 5mm. so as to give a fair finish including centring, shuutering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling upto all floor levels. and removal of the same for insitu-reinforced concrete & plain concrete work including carriage of materials in all leads and lift as per direction of Engineer in Charge:-(i) Foundations, footings, bases of columns, etc. for mass concrete. |
| 10 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick. |
| 11 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 12 | Columns, Pillars, Piers, Abutments, Posts and Struts Circular. |
| 13 | Stairs, (excluding landings) except spiralstaircases. |
| 14 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick. |
| 15 | Edges of slabs and breaks in floors and walls. Under 20 cm wide. |
| 16 | Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)of specified grade excluding the cost of centering and shuttering including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 17 | Providing and laying in position cement concrete 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) of specified grade excluding the cost of centering and shuttering, All work up to plinth levelincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 18 | Stone soling properly hand-packed filling interstices with Kharanja stone compected with durmut, for specified thickness complete as per HP.PWD specification including carriage of materials in all leads and lifts as per direction of Engineer in Charge. |
| 19 | Providing and laying cement concrete mechanicaily mixed and vibrated 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size.) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishingincluding carriage of materials in all leads and lifts as per direction of Engineer in Charge. |
| 20 | Providing and laying in position plain cement concrete 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20mm nominal size)mechanically mixed and vibrated of specified grade of plain cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level completeincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 21 | Providing and laying in position reinforced cement concrete 1:1½:3 (1 cement : 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) mechanically mixed and vibrated of specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level completeincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 22 | Providing and laying in position reinforced cement concrete 1:1½:3 (1 cement : 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) work mechanically mixed and vibrated in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to all floor level, excluding cost of centering, shuttering, finishing and reinforcement complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 23 | Providing and laying in position reinforced cement concrete 1:1½:3 (1 cement : 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)work mechanically mixed and vibrated in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to all floor level, excluding the cost of centering, shuttering, finishing and reinforcement complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 24 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability for all work up to plinth level complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 25 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability for all work above plinth level upto floor all level complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 26 | Providing and laying upto all floor levels cement concerete work 1:1½:3 (1 cement : 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) to give smooth and even suface including centering and shuttering but excluding cost of reinforcement and curing complete mechanical mixed and vibrate for compacting reinforced concerete upto floor all flor levels including carriadge of material in all leads and lifts. moulding as in cornices, window sills etc excluding 15cm in girth. (i) Sting cources, copings bedplates, anchor blocks, plain window sills and the like. |
| 27 | Moulding as in cornices window sills etc. not exceeding 15 cm in girth. |
| 28 | Providing and laying in position steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. and other works including straightening, cutting, bending, placing in position and binding all complete for all levels complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 29 | Applying cement slurry on R.C.C. slab or cement concrete work using 2.75kgs of cement per square metre of floor area before laying cement concrete flooring including roughening, cleaning of the concrete surfaces complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 30 | Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Cement mortar 1:6 (1 cement : 6 sand) in superstructure for all floor levels in all shapes and sizesincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 32 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:4 (1 cement :4 coarse sand) in superstructure for all floor levelsincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 33 | Providing wood work in second class deodar wood in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 34 | Providing and fixing 35mm thick 2nd class deodar wood panelled glazed or panelled and glazed shutters for doors windows and clerestory windows Including black enamelled iron butt hinges with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 35 | Providing and fixing anodised aluminium work duly powder coated of required shade for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleat angle, aluminum, snap beading for glazinge/panelling C.P. brass/ stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge. (i)For doors windows and ventilatiors and glazed partitions frames including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 36 | Providing and fixing glazing in powder coated aluminium door, window, ventilator shutters and partition etc with PVC / neoprens gasket etc. complete as per the architectural drawings and the directions of Engineer-In-charge (cost of aluminium snap beading shall be paid in basic item) Glazing with glass panes of 5.00mm thickness (weight not less than 13.75 kg/ sqm including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.00 mm thicknessweight not less than 12.50 kg / sqm including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 38 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. (Only weight of grill to be measured for payment)including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 39 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm fixed with2nd class deodar wood beading 40x12mm all complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 40 | Providing and fixing 40mm x 5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30cm x 10cm x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 41 | Providing and fixing200x10mm stainless steel tower bolts, ISI marked of approved design with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 42 | Providing and fixing 125mm stainless steel handles ISI marked of approved design with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 43 | Providing and fixing 250x16mm aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. completeincluding carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 44 | Providing and fixing 200x10mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 45 | Providing and fixing 150x10mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 46 | Providing and fixing aluminium 125mm size handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 47 | Providing and fixing aluminium 100mm size handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 48 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. with brass/ Stainless steel cover plate minimum 1.25mm thickness including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 49 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body with necessary accessories and screws etc. complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 50 | Providing and laying vitrified planks in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 1200mm X 200mmx10mmincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 51 | Providing and layingdouble charged digital vitrified floor tiles in 600mmx600mmx10mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 52 | Providing and laying full body vitrified floor tiles in different sizes 300mm X 300mm x10mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 53 | Providing and layingwhite / coloured tiles in different sizes 300mmx450mm, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 54 | Providing and laying mirror polished Kota stone slab 25mm thick in flooring over 20mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab Including rubbing and polishing complete (slab size not less than 550mm x 550mm ) including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 55 | Kota stone slabs mirror polished 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing completeincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. . |
| 56 | Providing and laying heavy duty precast cement concrete inter locking paver blocks vibro compacted upto of M -50 grade including border or kurb block grey or coloured over sub-base of concrete with 25 mm thick average thickness of cement mortar 1:4 ( 1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks including curing ribbing and polishing complete sub-base concrete floor to be paid for separately all complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. (i) 80 mm thick inter locking blocks. |
| 57 | 60mm thick inter locking blocks. |
| 58 | Granitework gang saw cut (polished and machine cut) of thickness 20 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately)completeincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 59 | Providing and fixing garsa / unistone / GRC 12 mm thick cladding upto all floor heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately)completeincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 60 | Extra for pre finished nosing to treads of steps of Polished Granite stone / kota stone completeincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 61 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.Using rough kota stone including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 62 | Steel work welded in built up sections and hollow sections in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required including carriage of materials in all leads and lift as per direction of Engineer in Charge:- In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 63 | Refixing of M.S. steel railing / fencing with electric welding etc. complete, earth work and cement concrete to be measured and paid for separatelyincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 64 | Providing and fixing in position collapsible steel shutters with vertical channels 20mm x 10mm x 2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40mm x 40mm x 6mm, with 40mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 65 | Finishing with Deluxe Multi surface paint system for interiors and exteriors with Two or more coat applied @ 0.90 liters/ 10 square metre over an under coat of primer applied @ 0.80 liters// 10 square metreof approved brand and manufacture using Primer as per manufacturers specifications complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 66 | Painting steel work with Deluxe Multi Surface Paint to give an even shade, one or more coatof approved brand and manufactureincluding carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 67 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50grams/ litre complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 68 | Painting wood work with Deluxe Multi Surface Paint of required shade two or more coat applied @ 90 liters/ 10 square metre over an under coat of primer applied @ 0.75 liters/ 10 square metre of approved brand and manufacture complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 69 | 6 mm thick cement plaster of mix 1:3 (1 cement : 3 fine sand) in ceiling upto all floor level including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 70 | 15mm cement plaster in single coat on rough side of brick / concrete / stone walls for interior / exterior plastering upto floor all level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. in Cement Mortar 1:6(1 cement:6 sand) complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 71 | 15mm cement plaster in single coat on fair side of brick / concrete / stone walls for interior / exterior plastering upto floor all level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. in Cement Mortar 1:6(1 cement:6 sand) complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 72 | Wall painting with premium acrylic emulsion asian / Deluxepaint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 73 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 74 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall/ ceiling surface to prepare the surface even and smooth complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 75 | Constructing Course rubble hammer dressed \"U\" shape open surface drain with side wall. 15x22 cm in cement mortar 1:6 (1 Cement : 6 Sand) and inside plastring with cement plaster 1:3 (1 Cement:3 Sand) including earth work and laying 10 cm cement concrete in 1:5:10 (1 Cement : 5 Sand : 10 graded stone aggregate) of 40 mm nominal size and 7.5 cm cement concrete 1:2:4 (1 Cement : 2 Sand : 4 graded stone aggregate 20 mm nominal size) complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 76 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge for all leads including all lifts involved as per direction of Engineer in Charge. |
| 77 | Providing and fixing 6mm thick HPL Sheet ISI markedin linning with butt joints & fixing with rivets powder coated matching to shade of HPL Sheet complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 78 | Providing and fixing ACP sheet 5mm thick panel in aluminium door, window, ventilator shutters and partition etc with PVC/neoprens gasket etc. complete as per the architectural drawings and as per the directions of Engineer-In-charge (cost of aluminium snap beading shall be paid in basic item) partitions with 12mm thick Particle board bwp phenol bonded exterior/ interior grade both sidescomplete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 79 | Providing and fixing polycarbonatd tranparent sheet 8mm thick in roofing with galvanised J or L hooks bolts and nuts with G.I. Limpe and bitumen rubber washer complete with all accessories complete including carriage of materials within all leads and lifts.as per direction of Engineer-in-Charge. |
| 80 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting chase and making good the walls etc. complete including carriage of materials within all leads and lifts as per direction of Engineer-in-Charge.Internal work.(i) 15mm nominal dia |
| 81 | 20mm nominal dia |
| 82 | 40mm nominal dia |
| 83 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete 20mm to 40mm nominal bore complete including carriage of materials within all leads and lifts as per direction of Engineer-in-Charge. |
| 84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of required capacity, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes including fittings like tank nipples, ball cock etc excluding base support for tank complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 85 | Providing and fixing high pressure PVC finolex type B spigot and socket, waste and ventilating pipes ISI marked including fitting with approved adhesive etc. complete including carriage of materials within all leads andlifts as per direction of Engineer in Charge. :- (i) 110mm dia. |
| 86 | 150mm |
| 87 | Providing and fixing PVC clamps ISI marked of approved design with steel screws and rawal plugs etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge:- (i) 110mm size. |
| 88 | 150mm size |
| 89 | Providing and fixingPVC finolex Type B plain bendISI marked including fixing with approved adhesive etc.complete including carriage of materials within all leads andlifts as per direction of Engineer in Charge:- (i) 110mm dia |
| 90 | 150mm |
| 91 | Providing and fixingPVCfinolex type B single equal branch plain ISI marked including fixing with approved adhesive etc. complete including carriage of materials within all leads andlifts as per direction of Engineer in Charge:-(i) 110mm dia. |
| 92 | 150mm |
| 93 | (i) Providing and fixingPVC Finolex Type B collars ISI marked including fixing with approved adhesive etc.complete including carriage of materials within all leads andlifts as per direction of Engineer in Charge:-(i)110mm dia. |
| 94 | ii) 150mm |
| 95 | Providing and fixingPVC (Finolex)floor trap ISI marked 110mm X 90mm size of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge:- |
| 96 | Providing and fixing 110mm dia PVCFinolex ‘P’ or \"S\" trap for water closet (squatting pan) ISI marked including jointing the trap with the pan and PVC pipe with approved adhesive etc.complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 97 | Providing and fixing viterous China wash down water closet (European type W.C. pan) universal closet including PVC10.00ltr. capacity cistern with inlet pipe star white Hindware catlogue No. 20012 or equivalent i/c white solid type plastic seat and cover complete set with intergal P or S trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement :1 sand) complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 98 | Providing and fixing white vitreous china Orissa pattern W.C Pan of size 580x440mm water closet squatting pan (Indian type) along with “S” or “P” trapincluding PVC10.00ltr. capacity cistern with inlet pipe star white Hindware catlogue No. 20012 or equivalent complete with all operations including all necessary materials as per the direction of Engineer-in charge complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 99 | Providing and fixing white vitreous China Wash basin size 560x420x820mm with Cat No.10032 or equivalent with Pedestal Cat No.11010 or equivalent, C.I. brackets, 32 mm C.P. brass waste of standard pattern, and 15 mm dia C.P. brass single hole basn mixure of approved quality and make including painting of fittings and brackets, cutting and making good the walls wherever require complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 100 | Providing and fixing vitreous chinastar white Hindware cat No.60002 or equivalent Half stall urinal of size 37.5cmx39cmx59cm including connection the urinal with waste pipe with PVC white automatic flushing cistern with fitting, flush pipe and and C.P. pipe and spreader by means of white lead mixed with chopped hemp including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 101 | Providing and fixing of ESS-ESS make or equivalent 32mm dia C.P. waste coupling for wash basin or sink including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 102 | Providing and fixing 100 mm dia chromium plated grating of superior quality for floor, gully or nahani trapincluding carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 103 | Providing and fixing 600x450mm beveled edgemirror of superior glass (of approved quality) complete with mounted on 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete including carriage of materials within all leads and liftsas per direction of Engineer in Charge. |
| 104 | Providing and fixinggun metal gate valve with C.I. wheel of approved quality (screwed end) including carriage of materials within all leads and lifts as per direction of Engineer in Charge. (i) 15mm nominal bore |
| 105 | (ii) 20mm nominal bore. |
| 106 | Providing and fixingG.Iunions in G.I pipeincluding cutting and threading the pipe and making long screw etc complete. carriage of materials within all leads and lifts as per direction of Engineer in Charge. (i) 15mm nominal dia. |
| 107 | (ii) 20mm nominal dia. |
| 108 | Providing and fixing C.P. toilet paper holder of of ESS ESS make catlogue No. AC-106or its equivalent complete including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 109 | Providing and fixing Wall mixer with telephonic shower arrangement with crutch Shower of ESS ESS make catlogue No. C-214A or its equivalent including connection fitting complete in all respect complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 110 | Providing and fixing C.P. brass bib cock with flenge15mm nominal bore of ESS ESS make catlogue No. C-202B or equivalent complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 111 | Providing and fixing 32mm dia PVC waste pipe for wash basin or sink complete including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 112 | Providing and fixing15 mm nomoinal bore PVC conection pipe with brass union of viking make or its equivalent including carriage of materials in all leads and lift as per direction of Engineer in Charge:- |
| 113 | ConstructingManhole 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 114 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 115 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(nonmodular) bricks of class designation 7.5, including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 116 | Cutting holes up to 30x30 cm in walls including making good the same with common burnt clay F.P.S. (non modular) bricks including carriage of materials in all leads and lift as per direction of Engineer in Charge. |
| 117 | Providing and fixing health faucet of ESS ESS make Cat No. C 232X or equivalent for water closet including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 118 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate for Eureopean type W.C. of approved quality and make as approved by Engineer-in - charge including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 119 | Providing and fixing 15mm nominal bore C.P. angle cock with flange of ESS ESS make catlogue No. C-204 or its equivalent of approved quality and colourwith flange including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
| 120 | Providing and fixingC.P. Soap dish of ESS ESS make catlogue No. AC-103 or its equivalent complete fixed to wooden plugs with C.P. screws including carriage of materials within all leads and lifts as per direction of Engineer in Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy