Ioaod Engg Development Of New A Site Regular Retail Outlet At Langting, Dist- Dima Hasao, Assam. => Limited, assam-Mizoram

Indian Oil Corporation Limited-IOCL has published Ioaod Engg Development Of New A Site Regular Retail Outlet At Langting, Dist- Dima Hasao, Assam. => Limited. Submission Date for this Tender is 29-03-2022. Land Development Tenders in assam Mizoram. Bidders can get complete Tender details and download the document.




Tender Notice

31458025
Corrigendum : Ioaod Engg Development Of New A Site Regular Retail Outlet At Langting, Dist- Dima Hasao, Assam. => Limited
Open Tender
Indian
Mizoram
assam
29-03-2022

Tender Details

Ioaod Engg Development Of New A Site Regular Retail Outlet At Langting, Dist- Dima Hasao, Assam. => Limited

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Mar-2022 Corrigendum on Earnest Money Deposit (EMD) Technical Bid 29-03-2022
2 27-Mar-2022 Date Corrigendum Date 29-03-2022

Key Value

Document Fees
Refer document
EMD
INR 190000.0 /-
Tender Value
INR 1.90 Crore /-

BOQ Items

Name of Work: Development of new "A"site RO at location "Langting, Dist- Dima-Hasao, Assam.
Sl. No. Item Description
1NRO LANGTING - NON CIVIL
2INSTALLATION OF 2X20 KL TANK IN EARTHPIT AND MANHOLE CHAMBER(100% ITC)
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
4ii) Ordinary rock
5Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
6Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
7iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
8Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
9ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
10Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
11ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
12Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
13i) Foundations,footings,bases of column
14Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
15i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH
16Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
17i) Local Fine Sand within grading zone IV
18Providing and laying cement plaster on surfaces with fine sand including curing etc.
19i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
20Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm)
21Supplying and installation of the following threaded
22i) 80 mm dia Aluminium camlock coupling - Male only
23Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor)
24iii) 15/20 KL Tank with fittings : 0 - 30 Km
25iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km
26Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20
27ii) In earth pit with RCC matt raft as per standard Drg. ENG/314
28Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.
29Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping
30ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping
31iv) S/L Welded U/G HD MS Pipes of 40mm dia with fittings,doping
32Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job)
33Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loadedtype or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Coverand adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval.
34Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazingwire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends.
35i) Supply & installation of U type CS bend on vent pipe of 80 mm dia
36Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
37ii) Ordinary rock
38Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
39iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
40Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
41i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH
42Providing and laying cement plaster on surfaces with fine sand including curing etc.
43i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
44Providing Neat cement punning
45Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
46MPD AND STP INSTALLATION(100% ITC)
47Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
48i) All kinds of Soil
49Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
50i) Local Fine Sand within grading zone IV
51Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
52iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
53Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
54iv) Granite of any colour and shade having Area of slab over 0.50 sqm
55Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.
56Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
57ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
58Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
59viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
60Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
61Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.
62Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping
63iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping
64Supplying and installation of the following threaded Caps conforming to detailed specification
65i) S/I of Threaded caps of 50 mm dia for dip pipe
66Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve
67iii) S/I Screwed type GM Ball Valve of50 mm dia
68Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump
69i) 2 product - 4 nozzle MPPs/MPDs
70Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor)
71xii) MPD/MPP pumps upto 2 nos., 0-30 Km
72xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km
73viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km
74ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km
75Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein
76iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein
77Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge
78DU ELECTRIFICATION(100% ITC)
79Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
80ii) 150 mm dia. R.C.C. pipe
81CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
82vi) 3 Core x 1.5 sq. mm.
83vii) 3 Core x 2.5 sq. mm
84FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
85vii) 3 Core x 2.5 sq. mm
86vi) 3 Core x 1.5 sq. mm.
87CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
88iii) 3 Core x 1.5 sq. mm. (copper)
89iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
90Supplying and fixing of following MCBs with necessery inter connectionson existing DB, Panel board etc.
91ii) Upto 32A DP MCB
92Supply and installation of MCB distribution boardhaving Doubledoorcomplete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. withoutincoming isolator and MCBs
93iii) 2+12 way SPN
94SINGLE SERVO VOLTAGE STABILISER Supply and fixing of 230V, Single phase, AC Servo voltage stabilizer ofapproved makes,(Range - 180 - 250 minimum) shall be provided for Individualdispensing pump as per IE Regulation and as per specification
95iv) 5KVA stabilizer
96CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protectionincluding all accessories complete (for displays) for the following VA ratings.
97iii) 500VA CVT
98SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer"s specification and direction of Engineer In-charge.
99viii) 15 A Modular switch
100x) 15 A6 Pin Modular socket
101iv) 6 module frame
102Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make
103i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire
104Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
105vi) 8 S.W.G. G.I. Wire (bare)
106i) 50 x 10mm G.I. Strip
107ii) 32 x 6 mm G.I.strip
108v) 25 x 3 mm GI strip
109Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
110Lettering with black japan paint of approved brand & manufacture and (unit/letter/cm ht)
111Supply & fixing of 300mA RCCB of approved Make of following ratings:
112ii) 2 poles, 40A
113iii) Current Capacity:40kA Primary Conductor(Inner pipe dia-32NB; Electrode Outer Pipe Dia-65NB Length of Concentric Pipes:3M
114YARD LIGHTING (18 NOS)(100% ITC)
115Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
116ii) 150 mm dia. R.C.C. pipe
117Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
118i) All kinds of Soil
119Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
120iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
121Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
122i) Foundations,footings,bases of column
123CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
124iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
125CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
126xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS
127FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
128vii) 3 Core x 2.5 sq. mm
129Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge.
130i) "Y" Pole
131OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) :
132iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)
133FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
134xviii) 3.5 Core x 50 sq. mm
135Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete.
136ii) S/EArm " Y " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge
137Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
138Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
139ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
140Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
141ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
142AIR FACILITY(100% ITC)
143Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.)
144Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall.
145iii) 25 mm nominal outer dia Pipes
146FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
147vii) 3 Core x 2.5 sq. mm
148CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
149iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
150Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works:
151ii) Horizontal air compressor Assembly of 3 HP (160-220 LITRES) including civil works
152Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
153ii) Ordinary rock
154Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
155ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
156Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
157ii) 150 mm dia. R.C.C. pipe
158Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
159ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
160Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
161ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
162Providing and laying cement plaster on surfaces with Coarse sand including curing etc.
163ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
164Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.
165UNIPOLE FOUNDATION(100% ITC)
166Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
167ii) Ordinary rock
168Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
169i) Local Fine Sand within grading zone IV
170Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
171iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
172Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
173ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
174Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
175i) Foundations,footings,bases of column
176Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
177ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
178Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
179viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
180Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall
181vi) 50 mm nominal outer dia Pipes
182Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :
183v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate
184CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
185iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
186CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
187vii) 3 Core x 2.5 sq. mm
188Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing.
189i) For cables 2.5 to 4 sqmm XLPE / AYFY
190Supplying and fixing of following MCBs with necessery inter connectionson existing DB, Panel board etc.
191ii) Upto 32A DP MCB
192Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.
193Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
194iv) Granite of any colour and shade having Area of slab over 0.50 sqm
195NRO LANGTING -CIVIL
196DRIVEWAY AND APPROACH WITH EDGE RESTRAINTS 1800 SQM(NIL ITC)
197Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
198ii) Ordinary rock
199Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises
200Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications.
201Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer
202Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL"s specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately)
203ii) M40 grade 80 mm thick reflective type Lacquered finish
204Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge.
205ii) With material confirming to grade-II (size 53 mm to .075 mm) having CBR value -25,Thickness as desired
206Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
207Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
208iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
209Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
210i) Foundations,footings,bases of column
211Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
212ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
213Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
214ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
215Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
216i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH
217Providing and laying cement plaster on surfaces with fine sand including curing etc.
218i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
219CONSTRUCTION OF BUFFER STRIP(NIL ITC)
220Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
221ii) Ordinary rock
222Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
223iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
224Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
225i) Foundations,footings,bases of column
226Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
227ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
228Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
229Providing and laying cement plaster on surfaces with fine sand including curing etc.
230i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
231Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
232CONSTRUCTION OF SALES BUILDING(7M X 3M)(NIL ITC)
233Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing :
234iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm
235vi) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 40mm
236Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
237Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil
238Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
239ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
240Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
241i) All kinds of Soil
242Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
243i) Local Fine Sand within grading zone IV
244Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
245ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
246Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement :
247ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
248Centering and shuttering including strutting, propping etc. and removal of form for :
249i) Foundations,footings,bases of columns, etc. for mass concrete
250iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ)
251iv) Lintels, beams plinth beams,girders bressumers and cantilevers
252Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
253ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
254viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
255Providing and laying cement plaster on surfaces with fine sand including curing etc.
256i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
257Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc.
258ii) 6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
259Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
260Supplying and laying bituminous carpet of 75mm thick for sand pad in two layers using Bitumen of grade VG-10, @100kg/Cum of sand grit of fineness modulus 3.5max. Including making slope in the sand pad including rolling the surface with Hand roller. Item includes laying of 1000 micron (1mm) black LDPE liner as per IS 2508 under the desired layer of sand
261Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement
26240mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete.
263Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm
264Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats
265Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
266Providingandfixing100x85x5.5 mm (heavy type) brightfinished brassbutthingeswithnecessary screws etc. complete :
267Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete
268Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete.
269Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality).
270Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover
271Providing and fixing ball bearing for rolling shutters.
272Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately)
273iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
274i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections
275Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
276i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
277iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm)
278Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
279Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
280i) With stainless steel cover plate
281Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in- charge
282i) Powder coated minimum thickness 50 micron aluminium
283Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
284ii) 110 mm diameter
285Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with greycement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified
286i)Flooring with size of Tiles 60x60Cm in cement mortar 1:4
28725mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab including rubbing and polishing complete. with baseof cement mortar 1 : 4 (1 cement : 4 coarse sand)
288Providing & fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 25 of approved design/pattern, with approved standard section & fixed to the existing window frame with C.P.brass /stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment)
289SALES BUILDING ELECTRIFICATION(NIL ITC)
290Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make
291iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire
292ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire
293iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire
294i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire
295PROVIDING INTERNAL WIRING
296ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
297SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer"s specification and direction of Engineer In-charge.
298iv) 6 module frame
299v) 8 module frame
300vii) 6A Modular Switch
301ix) 6A, 3 Pin Modular Socket
302x) 15 A6 Pin Modular socket
303PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032.
304Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL.
305SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer"s specification and direction of Engineer In-charge.
306xii) Fan Regulator of stepped modular type
307CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type:
308iii) 1200 mm sweep
309EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does notinclude making suitable cut out in thewall for fixing the fan).
310ii) 9" dia light duty, make Khaitan or equivalent
311Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
312Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
313TOILET BLOCK (4.5MX2.25M)(NIL ITC)
314Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing :
315iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm
316vi) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 40mm
317Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
318Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil
319Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
320ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
321Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
322i) All kinds of Soil
323Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
324i) Local Fine Sand within grading zone IV
325Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
326ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
327Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement :
328ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
329Centering and shuttering including strutting, propping etc. and removal of form for :
330i) Foundations,footings,bases of columns, etc. for mass concrete
331iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ)
332iv) Lintels, beams plinth beams,girders bressumers and cantilevers
333Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
334ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
335viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
336Providing and laying cement plaster on surfaces with fine sand including curing etc.
337i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
338Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc.
339ii) 6 mm cement plaster 1:3 (1 cement: 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
340Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
341Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement
34240mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete.
343Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm
344Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats
345Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
346Providingandfixing100x85x5.5 mm (heavy type) brightfinished brassbutthingeswithnecessary screws etc. complete :
347Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality).
348Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately)
349iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
350i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections
351Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
352i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
353Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in- charge
354i) Powder coated minimum thickness 50 micron aluminium
355Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
356ii) 110 mm diameter
357Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade.
358Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete.
359Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
360iv) Granite of any colour and shade having Area of slab over 0.50 sqm
361Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
362Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipewith manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
363Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cisternincluding flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required:
364i) W.C. pan with ISI marked white solid plastic seat and lid
365Providing and fixing white vitreous china flat back or wall corner type lippedfronturinalbasinof430x260x350mmand340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
366i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern
367Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
368i) 100 mm diameter
369Providing and fixing toilet paper holder :
370i) C.P. brass
371Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
372ii) 100mm inlet & 75mm outlet SCI S&S as per IS -3989.
373Providing and fixing B class G.I. Pipes complete with G.I. fittings and clamps i/c making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall for WATER and AIR
374ii) 20 mm dia nominal bore
375Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.
376i) 15 mm nominal outer dia Pipes
377ii) 20 mm nominal outer dia Pipes
378Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
379i) 15 mm nominal bore
380ii) 20 mm nominal bore
381Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :
382ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
383Providing and fixing brass bib cock of approved quality :
384i) 15 mm nominal bore
385Providing and fixing brass stop cock of approved quality :
386i) 15 mm nominal bore
387Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
388i) 25 mm nominal bore
389Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
390Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
391ii) 150 mm diameter
392Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
393ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
394Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
395i) 100 mm diameter S.W. pipe
396Providingandfixingsquare-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I.cover with frame of 300 x300 mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
397i) 100x100 mm size P type with common burnt clay bricks of class Designation 7.5
398Providing Neat cement punning
399Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
400iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
401Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
402ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
403Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
404Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil
405Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
406ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
407Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
408i) All kinds of Soil
409Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
410ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
411viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
412Providing and laying cement plaster on surfaces with Coarse sand including curing etc.
413ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
414Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make
415iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire
416ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire
417iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire
418i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire
419PROVIDING INTERNAL WIRING
420ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
421SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer"s specification and direction of Engineer In-charge.
422iv) 6 module frame
423vii) 6A Modular Switch
424EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does notinclude making suitable cut out in thewall for fixing the fan).
425ii) 9" dia light duty, make Khaitan or equivalent
426Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
427Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
428Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
429SIDE DRAIN(NIL ITC)
430Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
431ii) Ordinary rock
432Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
433vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
434Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
435i) Foundations,footings,bases of column
436Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
437ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
438Providing and laying cement plaster on surfaces with Coarse sand including curing etc.
439ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
440Providing Neat cement punning
441CULVERT ON BOTH APPROACHES & OPEN DRAIN(NIL ITC)
442Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
443i) All kinds of Soil
444Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
445iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
446Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
447ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
448Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
449i) Foundations,footings,bases of column
450Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
451ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
452Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
453Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
454Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
455ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
456Providing and laying cement plaster on surfaces with Coarse sand including curing etc.
457ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
458Providing Neat cement punning
459Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
460v) 600 mm dia. R.C.C. pipe
461CONSTRUCTION OF 2 NOS CANOPY FOUNDATION(NIL ITC)
462ii) Ordinary rock
463Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
464Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
465vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm)
466Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
467ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
468Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
469ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
470Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
471i) Foundations,footings,bases of column
472Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :
473v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate
474Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
475ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
476Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
477iv) 300 mm dia. R.C.C. pipe
478ii) 150 mm dia. R.C.C. pipe
479FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
480vi) 3 Core x 1.5 sq. mm.
481vii) 3 Core x 2.5 sq. mm
482Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
483xi) 10 S.W.G. Cu. Wire
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail