Irrigation And Flood Control Department-IFCD has published Annual Maintenance Contract Amc Electrical Annual Electrical Rate Contract For Lift Irrigation Schemes Of Mechanical Irrigation Division Baramulla. Submission Date for this Tender is 04-04-2022. Irrigation Work Tenders in baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-Mar-2022 | Corrigendum | Other | 02-04-2022 |
2 | 26-Mar-2022 | Corrig | Other | 02-04-2022 |
3 | 01-Apr-2022 | Corrigendum | Date | 04-04-2022 |
Sl. No. | Item Description |
1 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: |
2 | Private car, auto-rickshaw or similar with 1.0 km lead |
3 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
4 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
5 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
6 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
7 | Load carrier auto, mini van or similar with 1.0 km lead |
8 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
9 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
10 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
11 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
12 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
13 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
14 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
15 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
16 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
17 | Truck, tipper or similar with 1.0 km lead |
18 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
19 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
20 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
21 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
22 | Head load carriage of machinery/equipment at locations inaccessible by vehicles on plain/rough terrain |
23 | upto 50 Kgs load |
24 | Extra for every additional 50 Kgs load (Note: Fraction >= 25Kgs shall be taken as equivalent to next load of 50 Kgs) |
25 | Extra for uphill terrain (Ground Slope >= 07 deg) |
26 | Hiring of mobile crane upto 5 Ton capacity |
27 | Hiring of excavator for earthwork excavation. |
28 | MOTORS Dismantling:- Disconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, taking out the rotor from the stator, and complete disassembly as per requirement of job: |
29 | upto 10 HP |
30 | >10HP upto 60 HP |
31 | >60 upto 200 HP |
32 | >200 HP upto 350 HP |
33 | greater than 350 HP |
34 | Assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load. |
35 | upto 10 HP |
36 | >10HP upto 60 HP |
37 | >60 upto 200 HP |
38 | >200 HP upto 350 HP |
39 | greater than 350 HP |
40 | Replacement of Non Reverse Ratchet on Driving End (DE) of Vertical electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling and dismounting of motor from the motor stool. Removal of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting after necessary repairs/ replacements. Refitting of motor, coupling and alignment with the pump. The job includes testing of motor on load. |
41 | Replacement of Non Reverse Ratchet on Non Driving End (NDE) of Vertical electric motor by way of: Isolating the motor, dismantling of top end cover of the motor, removing of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting back of parts after necessary repairs/ replacements and testing of motor on load. |
42 | Replacement of Driving End (DE) bearing of Vertical electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor from the motor stool. Opening the bottom end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
43 | upto 60 HP rating |
44 | >60 upto 200 HP |
45 | >200 HP upto 350 HP |
46 | greater than 350 HP |
47 | Replacement of Non Driving End (NDE) bearing of Vertical electric motor by way of: Disconnecting all leads from motor and marking of terminals, dismantling of top end cover of the motor & removal of non-reverse ratchet assembly. Draining off the m.oil and collection in a suitable pan (if applicable), extraction of old damaged bearing from the motor, fitting of new NDE bearing and refilling of old m.oil. The job includes load testing of motor. |
48 | upto 60 HP rating |
49 | >60 upto 200 HP |
50 | >200 HP upto 350 HP |
51 | greater than 350 HP |
52 | Replacement of Driving End (DE) bearing of horizontal electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
53 | upto 60 HP rating |
54 | >60 upto 200 HP |
55 | >200 HP upto 350 HP |
56 | greater than 350 HP |
57 | Replacement of Non-Driving End (NDE) bearing of horizontal electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
58 | upto 60 HP rating |
59 | >60 upto 200 HP |
60 | >200 HP upto 350 HP |
61 | greater than 350 HP |
62 | VOLTAGE STABILIZERS:- Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. |
63 | upto 50 kVA |
64 | >50 upto 100kVA |
65 | >100kVA upto 250 kVA |
66 | greater than 250 kVA |
67 | Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil |
68 | upto 50 kVA |
69 | >50 upto 100kVA |
70 | >100kVA upto 250 kVA |
71 | greater than 250 kVA |
72 | STARTER:- Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. |
73 | upto 60 HP rating |
74 | >60 upto 200 HP |
75 | >200 HP upto 350 HP |
76 | greater than 350 HP |
77 | Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. |
78 | upto 60 HP rating |
79 | >60 upto 200 HP |
80 | >200 HP upto 350 HP |
81 | greater than 350 HP |
82 | WINDING WORKS:- Complete winding of stator coils of 3-phase LV horizontal/ vertical induction motor/ submersible motor/ autotransformer/ voltage stabilizer/ etc. and the like with suitable copper wire (excluding carriage and dismantling/ reassembling charges). (Note: The unserviceable scrap copper has not been taken into account for estimation of rates and shall be deducted seperately on actual basis refer item 79 ). |
83 | Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., (Both HV & LV) - per kg of winding. |
84 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., (Both HV & LV) - per kg of winding. |
85 | Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. (excluding dismantling/ refitting charges) of motors |
86 | upto 5HP |
87 | > 5 HP upto 20 HP |
88 | > 20 HP upto 50 HP |
89 | > 50 HP upto 100 HP |
90 | > 100 HP upto 200 HP |
91 | > 200 HP upto 350 HP |
92 | > 350 HP |
93 | VOLTAGE STABILIZERS |
94 | Providing and replacement of copper contact points on regulator plate |
95 | Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) |
96 | Filtration of existing/ reclaimed T-oil on site at suitable temperature (inclusive of all logistics and charges for filtration plant, etc) (Process loss maximum of 5% allowed) |
97 | CONTACTORS:- Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: |
98 | L&T ML 1.5 |
99 | L&T ML 2 |
100 | L&T ML 3 |
101 | L&T ML 4 |
102 | L&T ML 6 |
103 | L&T ML 12 |
104 | L&T MNX 50 |
105 | L&T MNX 70 |
106 | L&T MNX 80 |
107 | L&T MNX 95 |
108 | L&T MNX 110 |
109 | L&T MNX 140 |
110 | L&T MNX 185 |
111 | L&T MNX 225 |
112 | L&T MNX 250 |
113 | Schneider Electric LC1F265 (without coil) |
114 | Schneider Electric LC1F330 (without coil) |
115 | Schneider Electric LC1F400 (without coil) |
116 | Schneider Electric LC1F630 (without coil) |
117 | 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) |
118 | 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) |
119 | Providing and fitting of new AC coil with specified coil voltage for contactors: |
120 | 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) |
121 | L&T ML 2/ 3 |
122 | L&T ML 4/ 6 |
123 | L&T ML 10/ 12 |
124 | L&T MNX 50/ 70/ 80 |
125 | L&T MNX 95/ 110/ 140 |
126 | L&T MNX 185/ 225/ 250 |
127 | L&T MNX 300/ 400 |
128 | L&T MNX 550/ 650 |
129 | Schneider Electric LC1F185/ LC1F225 |
130 | Schneider Electric LC1F265/ LC1F330 |
131 | Schneider Electric LC1F400 |
132 | Schneider Electric LC1F630 |
133 | Providing and fitting of new Contact kit set for contactors |
134 | 32A AC-3 rating (Siemens 3TF/equivalent) |
135 | L&T ML 2 |
136 | L&T ML 3 |
137 | L&T ML 4 |
138 | L&T ML 6 |
139 | L&T ML 10 |
140 | L&T ML 12 |
141 | Providing and fitting of auxillary/ control relay (L&T MX0 or similar) for AC control |
142 | Providing and fitting of auxillary/ control relay (L&T MN0 or similar) for DC control |
143 | Providing and fitting of (1NO+1NC) side mounting auxillary contact block(For L&T/ Schneider Electric make contactors). |
144 | Providing and fitting of front mounting auxillary contact block having 04 contacts (all combinations)(For L&T/ Schneider Electric/ Siemens make contactors) |
145 | MANPOWER |
146 | Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): |
147 | Hiring charges of Labourer for support of electrician |
148 | TIMING RELAYS:- Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) . |
149 | (2NO + 2NC) double block; ON delay |
150 | (2NO + 2NC) double block; ON & OFF delay |
151 | Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) |
152 | (2NO + 2NC) contact block |
153 | Magnetic coil 415V AC |
154 | Magnet frame assembly without coil |
155 | Providing, fitting and setting of DIN mounted electronic Timer (L&T or equivalent make) |
156 | Star Delta (range from 3s - 120s)240V AC |
157 | Star Delta (range from 3s - 30s)240 - 415V AC |
158 | ON delay (0.3s - 30hrs) 240V AC |
159 | Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) |
160 | THERMAL OVERLOAD RELAY:- Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) |
161 | Relay range in between 0.2A to 15A |
162 | 14-23A |
163 | 20-33A |
164 | 24-40A |
165 | Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) |
166 | 30-50A |
167 | 36-60A |
168 | 45-75A |
169 | 66-110A |
170 | Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T ML1) |
171 | Relay range in between 0.15A to 16A |
172 | Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T ML2/3) |
173 | Relay ranges in between 9A to 42A |
174 | MISCELLANEOUS:- Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots |
175 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. |
176 | Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. |
177 | Providing and fitting of copper contact kit set for starters/ circuit breakers and the like. |
178 | Providing and fitting of LV (1.1 KV) porcelain bushings of rating: |
179 | 250 A |
180 | 630 A |
181 | 1000 A |
182 | 2000 A |
183 | 3150 A |
184 | Providing and fitting of HV porcelain bushings of rating: |
185 | 250 A, 17.5KV |
186 | 630 A, 17.5KV |
187 | 1000 A, 17.5KV |
188 | 2000 A, 17.5KV |
189 | 250 A, 36KV |
190 | 630 A, 36KV |
191 | 1000 A, 36KV |
192 | 3150 A, 36KV |
193 | Copper |
194 | SWITCH GEARS:- MCCB:- Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: |
195 | upto and including 100A (Ics= 50% Icu) |
196 | 125A |
197 | 160A |
198 | 200A |
199 | 250A |
200 | 400A |
201 | Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under: |
202 | 125A |
203 | 160A |
204 | 200A |
205 | 250A |
206 | 400A |
207 | 630A |
208 | Providing of set of spreader terminals for above 3-pole MCCBs |
209 | 100A |
210 | 125A |
211 | 250A |
212 | 400A |
213 | 630A |
214 | Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: |
215 | 125A |
216 | 160A |
217 | 200A |
218 | 250A |
219 | 400A |
220 | 630A |
221 | SPARES FOR ACB (L&T C-POWER):- Providing and fitting of pole assembly for draw out type ACB (L&T C-power) |
222 | upto 1250A |
223 | 2000A |
224 | Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) |
225 | upto 1250A |
226 | 1600 - 2000A |
227 | Providing and fitting of Jaw contact for ACB (L&T C-power) |
228 | 630-1000A |
229 | 1250A |
230 | 1600A/ 2000A |
231 | Providing and fitting of Fixed arcing contact for ACB (L&T C-power) |
232 | 800- 1600A |
233 | 2000A |
234 | Providing and fitting of Moving arcing contact for ACB (L&T C-power) |
235 | 800- 2000A |
236 | Providing and fitting of Shunt release for ACB (L&T C-power) |
237 | Providing and fitting of Under Voltage Release for ACB (L&T C-power) |
238 | Providing and fitting of Earth Fault Release for ACB (L&T C-power) |
239 | Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: |
240 | upto 800 - 1250A |
241 | 1600 - 2000A |
242 | Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB |
243 | Providing and fitting of CT for DN1 type L&T C-power ACB |
244 | 800/ 1000A |
245 | 1250/ 1600A |
246 | 2000A |
247 | Providing and fitting of main spring for 3-pole ACB (L&T C-power) |
248 | 800- 1600A |
249 | 2000A |
250 | Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A |
251 | Providing and replacement of spring charging motor (AC/ DC) |
252 | Providing and replacement of motor limit switch |
253 | Instruments:- Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) |
254 | Providing and fitting of flush type analog moving iron AC meter as under: (Make: Rishabh/ AE/ C&S/ BCH) |
255 | 48x48mm 500V voltmeter |
256 | 96x96mm 500V voltmeter |
257 | 144x144mm 500V voltmeter |
258 | 96x96mm ammeter (5A CT operated) |
259 | Volt-Ammeter 500V, current ranges upto 125A (AE/ Rishabh/ L&T) |
260 | Providing and fitting of flush type frequency meter with range 45-55Hz: (Make: Rishabh/ AE/ L&T/ Schneider/ BCH) |
261 | Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) |
262 | Providing and fitting of 10A voltmeter selector switch with OFF (Make: L&T/ Rishabh/ AE/ Teknic) |
263 | Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: |
264 | 100/5A or 150/5A - Class 1 - Burden 5VA |
265 | 200/5A - Class 1 - Burden 10VA |
266 | 400/5A - Class 1 - Burden 15VA |
267 | 600/5A - Class 1 - Burden 15VA |
268 | 800/5A - Class 1 - Burden 15VA |
269 | 1000/5A - Class 1 - Burden 15VA |
270 | 2000/5A - Class 1 - Burden 15VA |
271 | Extra for 1A secondary upto 600/1A over corresponding rate |
272 | Providing and fitting of analog VAC hour meter (Make: L&T or equivalent make) |
273 | DIN mounting type |
274 | Flush mounting type |
275 | Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
276 | Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
277 | Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) |
278 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) |
279 | 50V or less unbalance & 1 C/ODIN mounted |
280 | 50V or less unbalance & 1 C/OPanel wall mounted |
281 | 70V or less unbalance & 2 C/ODIN mounted |
282 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) |
283 | Providing of HRC fuses (2A - 32A) ratings |
284 | Providing and fitting of Fuse holders for fuses upto 32A rating |
285 | Providing and fixing uPVC panel trunking with cover |
286 | 15x15mm |
287 | 25x25mm |
288 | Providing and fitting of Terminal Block 100A - 3 way |
289 | TERMINALS/ LUGS:- Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
290 | 16 sq. mm |
291 | 25 sq. mm |
292 | 35 sq. mm |
293 | 50 sq. mm |
294 | 70 sq. mm |
295 | 95 sq. mm |
296 | 120 sq. mm |
297 | 150 sq. mm |
298 | 185 sq. mm |
299 | 225 sq. mm |
300 | 240 sq. mm |
301 | 300 sq. mm |
302 | 400 sq. mm |
303 | 500 sq. mm |
304 | 630 sq. mm |
305 | Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
306 | 16 sq. mm |
307 | 25 sq. mm |
308 | 35 sq. mm |
309 | 50 sq. mm |
310 | 70 sq. mm |
311 | 95 sq. mm |
312 | 120 sq. mm |
313 | 150 sq. mm |
314 | 185 sq. mm |
315 | 225 sq. mm |
316 | 240 sq. mm |
317 | 300 sq. mm |
318 | 400 sq. mm |
319 | 500 sq. mm |
320 | 630 sq. mm |
321 | CABLES:- Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) |
322 | 1.5 sqmm |
323 | 2.5 sqmm |
324 | 4.0 sqmm |
325 | 6.0 sqmm |
326 | 10.0 sqmm |
327 | 16.0 sqmm |
328 | 25.0 sqmm |
329 | 35.0 sqmm |
330 | Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
331 | 16.0 sqmm |
332 | 25 sqmm |
333 | 35 sqmm |
334 | 50 sqmm |
335 | 70 sqmm |
336 | 95 sqmm |
337 | 120 sqmm |
338 | 150 sqmm |
339 | 185 sqmm |
340 | 240 sqmm |
341 | 300 sqmm |
342 | 400 sqmm |
343 | Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
344 | 16 sqmm |
345 | 25 sqmm |
346 | 35 sqmm |
347 | 50 sqmm |
348 | 70 sqmm |
349 | 95 sqmm |
350 | 120 sqmm |
351 | 150 sqmm |
352 | 185 sqmm |
353 | 240 sqmm |
354 | 300 sqmm |
355 | 400 sqmm |
356 | 500 sqmm |
357 | 630 sqmm |
358 | Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
359 | 25 sqmm |
360 | 35 sqmm |
361 | 50 sqmm |
362 | 70 sqmm |
363 | 95 sqmm |
364 | 120 sqmm |
365 | 150 sqmm |
366 | 185 sqmm |
367 | 240 sqmm |
368 | 300 sqmm |
369 | 400 sqmm |
370 | 500 sqmm |
371 | 630 sqmm |
372 | WIRING:- Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) |
373 | 1.0 sqmm |
374 | 1.5 sqmm |
375 | 2.5 sqmm |
376 | 4.0 sqmm |
377 | 6.0 sqmm |
378 | 10.0 sqmm |
379 | 16.0 sqmm |
380 | 2x1.5 sqmm |
381 | 2x2.5 sqmm |
382 | 2x6 sqmm (Aluminium unarmoured) |
383 | CONDUITS:- Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings |
384 | Providing and fixing uPVC trunking 25x16mm with allied fittings |
385 | Providing and fixing Polypropylene Corrugated flexible conduit |
386 | 25mm |
387 | 32mm |
388 | Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. |
389 | 100 x 50 x 1.6mm |
390 | 150 x 50 x 1.6mm |
391 | ELECTRICAL FITTINGS:- Providing and fitting of various electrical fittings as under (Preferred makes: Anchor/ SSK/ Havells) |
392 | Switch-6A-SP-1way, 240V, 50 Hz, AC. |
393 | Switch-6A-SP-2way, 240V, 50 Hz, AC. |
394 | Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. |
395 | Bell push 240V, 50 Hz, AC. |
396 | 6A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC. |
397 | Neon indicator |
398 | Mini telephone jack |
399 | Fan regulator (Mini) with rotary step |
400 | Fan regulator (Deluxe) with rotary step |
401 | Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC. |
402 | Plug Top 15/16A 3 Pin (ISI Marked) |
403 | 32A TP switch 415V with neon |
404 | 32A DP switch 240V with neon |
405 | Surface mounting box for switches as follows: |
406 | 1 Gang box |
407 | 2 Gang box |
408 | 3 Gang box |
409 | 4 Gang box |
410 | 5 Gang box |
411 | 6 Gang box |
412 | 7 Gang box |
413 | 4 Gang box (double domestic) |
414 | Providing, Fixing, Testing of 6A ceiling rose |
415 | Providing and installation of Pendant/ angle/ batten holders 6A 240V |
416 | Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) |
417 | 4 way |
418 | 8 way |
419 | 12 way |
420 | 16 way |
421 | Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) |
422 | 6-32A SP |
423 | 40A SP |
424 | 6-32A DP |
425 | 40A DP |
426 | 100A 4P isolator |
427 | Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) |
428 | 2-pole 16A 415V |
429 | 2-pole 32A 415V |
430 | 4-pole 32A 415V |
431 | 4-pole 63A 415V |
432 | 4-pole 100A 415V |
433 | Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T) |
434 | 63A 415V |
435 | 100A 415V |
436 | 200A 415V |
437 | Providing and installation of various type of fans as under: (Preferred makes: Havells/ Orient/ Crompton) |
438 | Industrial exhaust fan 450mm metallic |
439 | Exhaust fan 250mm Plastic |
440 | Ceiling fan 1200mm sweep |
441 | Wall fan 300mm sweep |
442 | ILLUMINATION:- LED Bulbs withE27 or B22 base and illumination 3000K/ 5700K/ 6500K (Preferred makes: Havells/ Philips/ Osram/ Eveready/ Crompton/ Syska/ Bajaj/ Andslite) |
443 | 0.5W |
444 | 5W |
445 | 9W |
446 | 15W |
447 | Providing and fitting of Open Construction (OC) Ballast for HID Lamps - 240V 50Hz |
448 | 1x70W SON/MH |
449 | 1x150W SON/MH |
450 | 1x250W SON/MH |
451 | Providing and fitting of Ignitor for HID lamps 70 - 400W |
452 | Providing, fixing and testing of various types of lamps as under: (Preferred makes: Havells/ Philips/ Osram Ledvance/ Bajaj):- Tungston linear halogen lamp |
453 | 500W |
454 | 1000W |
455 | Metal Halide Lamp |
456 | 70W/ 150W Single ended clear Tubular (MH SET) |
457 | 250W/ 400W Single ended clear Tubular(MH SET) |
458 | 70W/ 150W Double ended |
459 | High Pressure Sodium Vapour clear Tubular Lamp (SON-T) |
460 | 70W |
461 | 150W |
462 | 250W |
463 | 400W |
464 | High Pressure Sodium Vapour Elliptical Coated Lamp (SON-E) |
465 | 70W |
466 | PORTABLE LIGHTING:- 3 W Rechargeable LED torch (Preferred make: Havells/ Eveready/ Andslite/ Philips/ Syska) |
467 | LED Lantern with Twin Charging mode –Charging Cable & Solar Panel (included) (Syska/ Havells/ Andslite/ Philips/ Bajaj) |
468 | Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under: |
469 | Brass |
470 | Aluminium |
471 | Copper |
472 | Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under: |
473 | Brass |
474 | Aluminium |
475 | Copper |
476 | credit value for scrap Copper to be deducted and read as negative |
477 | credit value for scrap Aluminum to be deducted and read as negative |