Annual Maintenance Contract Amc Electrical Annual Electrical Rate Contract For Lift Irrigation Schemes Of Mechanical Irrigation Division Baramulla, baramulla-Jammu And Kashmir

Irrigation And Flood Control Department-IFCD has published Annual Maintenance Contract Amc Electrical Annual Electrical Rate Contract For Lift Irrigation Schemes Of Mechanical Irrigation Division Baramulla. Submission Date for this Tender is 04-04-2022. Irrigation Work Tenders in baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

31441036
Corrigendum : Annual Maintenance Contract Amc Electrical Annual Electrical Rate Contract For Lift Irrigation Schemes Of Mechanical Irrigation Division Baramulla
Open Tender
Indian
Jammu And Kashmir
baramulla
04-04-2022

Tender Details

Annual Maintenance Contract Amc Electrical Annual Electrical Rate Contract For Lift Irrigation Schemes Of Mechanical Irrigation Division Baramulla

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Mar-2022 Corrigendum Other 02-04-2022
2 26-Mar-2022 Corrig Other 02-04-2022
3 01-Apr-2022 Corrigendum Date 04-04-2022

Key Value

Document Fees
INR 200 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:Annual Electrical Framework Contract of major/ medium lift irrigation schemes of Mechanical Irrigation Division Baramulla
Sl. No. Item Description
1Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under:
2Private car, auto-rickshaw or similar with 1.0 km lead
3Extra per kilometer for lead >1.0 kms upto 5.0 kms
4Extra per kilometer for lead >5.0 kms upto 10.0 kms
5Extra per kilometer for lead >10.0 kms upto 20.0 kms
6Extra per kilometer for lead >20.0 kms upto 30.0 kms
7Load carrier auto, mini van or similar with 1.0 km lead
8Extra per kilometer for lead >1.0 kms upto 5.0 kms
9Extra per kilometer for lead >5.0 kms upto 10.0 kms
10Extra per kilometer for lead >10.0 kms upto 20.0 kms
11Extra per kilometer for lead >20.0 kms upto 30.0 kms
12Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead
13Extra per kilometer for lead >1.0 kms upto 5.0 kms
14Extra per kilometer for lead >5.0 kms upto 10.0 kms
15Extra per kilometer for lead >10.0 kms upto 20.0 kms
16Extra per kilometer for lead >20.0 kms upto 30.0 kms
17Truck, tipper or similar with 1.0 km lead
18Extra per kilometer for lead >1.0 kms upto 5.0 kms
19Extra per kilometer for lead >5.0 kms upto 10.0 kms
20Extra per kilometer for lead >10.0 kms upto 20.0 kms
21Extra per kilometer for lead >20.0 kms upto 30.0 kms
22Head load carriage of machinery/equipment at locations inaccessible by vehicles on plain/rough terrain
23upto 50 Kgs load
24Extra for every additional 50 Kgs load (Note: Fraction >= 25Kgs shall be taken as equivalent to next load of 50 Kgs)
25Extra for uphill terrain (Ground Slope >= 07 deg)
26Hiring of mobile crane upto 5 Ton capacity
27Hiring of excavator for earthwork excavation.
28MOTORS Dismantling:- Disconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, taking out the rotor from the stator, and complete disassembly as per requirement of job:
29upto 10 HP
30>10HP upto 60 HP
31>60 upto 200 HP
32>200 HP upto 350 HP
33greater than 350 HP
34Assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load.
35upto 10 HP
36>10HP upto 60 HP
37>60 upto 200 HP
38>200 HP upto 350 HP
39greater than 350 HP
40Replacement of Non Reverse Ratchet on Driving End (DE) of Vertical electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling and dismounting of motor from the motor stool. Removal of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting after necessary repairs/ replacements. Refitting of motor, coupling and alignment with the pump. The job includes testing of motor on load.
41Replacement of Non Reverse Ratchet on Non Driving End (NDE) of Vertical electric motor by way of: Isolating the motor, dismantling of top end cover of the motor, removing of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting back of parts after necessary repairs/ replacements and testing of motor on load.
42Replacement of Driving End (DE) bearing of Vertical electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor from the motor stool. Opening the bottom end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load.
43upto 60 HP rating
44>60 upto 200 HP
45>200 HP upto 350 HP
46greater than 350 HP
47Replacement of Non Driving End (NDE) bearing of Vertical electric motor by way of: Disconnecting all leads from motor and marking of terminals, dismantling of top end cover of the motor & removal of non-reverse ratchet assembly. Draining off the m.oil and collection in a suitable pan (if applicable), extraction of old damaged bearing from the motor, fitting of new NDE bearing and refilling of old m.oil. The job includes load testing of motor.
48upto 60 HP rating
49>60 upto 200 HP
50>200 HP upto 350 HP
51greater than 350 HP
52Replacement of Driving End (DE) bearing of horizontal electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load.
53upto 60 HP rating
54>60 upto 200 HP
55>200 HP upto 350 HP
56greater than 350 HP
57Replacement of Non-Driving End (NDE) bearing of horizontal electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load.
58upto 60 HP rating
59>60 upto 200 HP
60>200 HP upto 350 HP
61greater than 350 HP
62VOLTAGE STABILIZERS:- Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling.
63upto 50 kVA
64>50 upto 100kVA
65>100kVA upto 250 kVA
66greater than 250 kVA
67Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil
68upto 50 kVA
69>50 upto 100kVA
70>100kVA upto 250 kVA
71greater than 250 kVA
72STARTER:- Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank.
73upto 60 HP rating
74>60 upto 200 HP
75>200 HP upto 350 HP
76greater than 350 HP
77Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter.
78upto 60 HP rating
79>60 upto 200 HP
80>200 HP upto 350 HP
81greater than 350 HP
82WINDING WORKS:- Complete winding of stator coils of 3-phase LV horizontal/ vertical induction motor/ submersible motor/ autotransformer/ voltage stabilizer/ etc. and the like with suitable copper wire (excluding carriage and dismantling/ reassembling charges). (Note: The unserviceable scrap copper has not been taken into account for estimation of rates and shall be deducted seperately on actual basis refer item 79 ).
83Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., (Both HV & LV) - per kg of winding.
84Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., (Both HV & LV) - per kg of winding.
85Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. (excluding dismantling/ refitting charges) of motors
86upto 5HP
87> 5 HP upto 20 HP
88> 20 HP upto 50 HP
89> 50 HP upto 100 HP
90> 100 HP upto 200 HP
91> 200 HP upto 350 HP
92> 350 HP
93VOLTAGE STABILIZERS
94Providing and replacement of copper contact points on regulator plate
95Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector)
96Filtration of existing/ reclaimed T-oil on site at suitable temperature (inclusive of all logistics and charges for filtration plant, etc) (Process loss maximum of 5% allowed)
97CONTACTORS:- Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage:
98L&T ML 1.5
99L&T ML 2
100L&T ML 3
101L&T ML 4
102L&T ML 6
103L&T ML 12
104L&T MNX 50
105L&T MNX 70
106L&T MNX 80
107L&T MNX 95
108L&T MNX 110
109L&T MNX 140
110L&T MNX 185
111L&T MNX 225
112L&T MNX 250
113Schneider Electric LC1F265 (without coil)
114Schneider Electric LC1F330 (without coil)
115Schneider Electric LC1F400 (without coil)
116Schneider Electric LC1F630 (without coil)
11732A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider)
11845A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider)
119Providing and fitting of new AC coil with specified coil voltage for contactors:
1209A to 45A AC-3 rating (Siemens 3TF/ equivalent)
121L&T ML 2/ 3
122L&T ML 4/ 6
123L&T ML 10/ 12
124L&T MNX 50/ 70/ 80
125L&T MNX 95/ 110/ 140
126L&T MNX 185/ 225/ 250
127L&T MNX 300/ 400
128L&T MNX 550/ 650
129Schneider Electric LC1F185/ LC1F225
130Schneider Electric LC1F265/ LC1F330
131Schneider Electric LC1F400
132Schneider Electric LC1F630
133Providing and fitting of new Contact kit set for contactors
13432A AC-3 rating (Siemens 3TF/equivalent)
135L&T ML 2
136L&T ML 3
137L&T ML 4
138L&T ML 6
139L&T ML 10
140L&T ML 12
141Providing and fitting of auxillary/ control relay (L&T MX0 or similar) for AC control
142Providing and fitting of auxillary/ control relay (L&T MN0 or similar) for DC control
143Providing and fitting of (1NO+1NC) side mounting auxillary contact block(For L&T/ Schneider Electric make contactors).
144Providing and fitting of front mounting auxillary contact block having 04 contacts (all combinations)(For L&T/ Schneider Electric/ Siemens make contactors)
145MANPOWER
146Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works):
147Hiring charges of Labourer for support of electrician
148TIMING RELAYS:- Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) .
149(2NO + 2NC) double block; ON delay
150(2NO + 2NC) double block; ON & OFF delay
151Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent)
152(2NO + 2NC) contact block
153Magnetic coil 415V AC
154Magnet frame assembly without coil
155Providing, fitting and setting of DIN mounted electronic Timer (L&T or equivalent make)
156Star Delta (range from 3s - 120s)240V AC
157Star Delta (range from 3s - 30s)240 - 415V AC
158ON delay (0.3s - 30hrs) 240V AC
159Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make)
160THERMAL OVERLOAD RELAY:- Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2)
161Relay range in between 0.2A to 15A
16214-23A
16320-33A
16424-40A
165Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5)
16630-50A
16736-60A
16845-75A
16966-110A
170Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T ML1)
171Relay range in between 0.15A to 16A
172Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T ML2/3)
173Relay ranges in between 9A to 42A
174MISCELLANEOUS:- Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots
175Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement.
176Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement.
177Providing and fitting of copper contact kit set for starters/ circuit breakers and the like.
178Providing and fitting of LV (1.1 KV) porcelain bushings of rating:
179250 A
180630 A
1811000 A
1822000 A
1833150 A
184Providing and fitting of HV porcelain bushings of rating:
185250 A, 17.5KV
186630 A, 17.5KV
1871000 A, 17.5KV
1882000 A, 17.5KV
189250 A, 36KV
190630 A, 36KV
1911000 A, 36KV
1923150 A, 36KV
193Copper
194SWITCH GEARS:- MCCB:- Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under:
195upto and including 100A (Ics= 50% Icu)
196125A
197160A
198200A
199250A
200400A
201Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under:
202125A
203160A
204200A
205250A
206400A
207630A
208Providing of set of spreader terminals for above 3-pole MCCBs
209100A
210125A
211250A
212400A
213630A
214Providing and fitting of 4-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under:
215125A
216160A
217200A
218250A
219400A
220630A
221SPARES FOR ACB (L&T C-POWER):- Providing and fitting of pole assembly for draw out type ACB (L&T C-power)
222upto 1250A
2232000A
224Providing and fitting of Arc Chute (440V) for ACB (L&T C-power)
225upto 1250A
2261600 - 2000A
227Providing and fitting of Jaw contact for ACB (L&T C-power)
228630-1000A
2291250A
2301600A/ 2000A
231Providing and fitting of Fixed arcing contact for ACB (L&T C-power)
232800- 1600A
2332000A
234Providing and fitting of Moving arcing contact for ACB (L&T C-power)
235800- 2000A
236Providing and fitting of Shunt release for ACB (L&T C-power)
237Providing and fitting of Under Voltage Release for ACB (L&T C-power)
238Providing and fitting of Earth Fault Release for ACB (L&T C-power)
239Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under:
240upto 800 - 1250A
2411600 - 2000A
242Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB
243Providing and fitting of CT for DN1 type L&T C-power ACB
244800/ 1000A
2451250/ 1600A
2462000A
247Providing and fitting of main spring for 3-pole ACB (L&T C-power)
248800- 1600A
2492000A
250Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A
251Providing and replacement of spring charging motor (AC/ DC)
252Providing and replacement of motor limit switch
253Instruments:- Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE)
254Providing and fitting of flush type analog moving iron AC meter as under: (Make: Rishabh/ AE/ C&S/ BCH)
25548x48mm 500V voltmeter
25696x96mm 500V voltmeter
257144x144mm 500V voltmeter
25896x96mm ammeter (5A CT operated)
259Volt-Ammeter 500V, current ranges upto 125A (AE/ Rishabh/ L&T)
260Providing and fitting of flush type frequency meter with range 45-55Hz: (Make: Rishabh/ AE/ L&T/ Schneider/ BCH)
261Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic)
262Providing and fitting of 10A voltmeter selector switch with OFF (Make: L&T/ Rishabh/ AE/ Teknic)
263Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under:
264100/5A or 150/5A - Class 1 - Burden 5VA
265200/5A - Class 1 - Burden 10VA
266400/5A - Class 1 - Burden 15VA
267600/5A - Class 1 - Burden 15VA
268800/5A - Class 1 - Burden 15VA
2691000/5A - Class 1 - Burden 15VA
2702000/5A - Class 1 - Burden 15VA
271Extra for 1A secondary upto 600/1A over corresponding rate
272Providing and fitting of analog VAC hour meter (Make: L&T or equivalent make)
273DIN mounting type
274Flush mounting type
275Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make)
276Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make)
277Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent)
278Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make)
27950V or less unbalance & 1 C/ODIN mounted
28050V or less unbalance & 1 C/OPanel wall mounted
28170V or less unbalance & 2 C/ODIN mounted
282Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make)
283Providing of HRC fuses (2A - 32A) ratings
284Providing and fitting of Fuse holders for fuses upto 32A rating
285Providing and fixing uPVC panel trunking with cover
28615x15mm
28725x25mm
288Providing and fitting of Terminal Block 100A - 3 way
289TERMINALS/ LUGS:- Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:
29016 sq. mm
29125 sq. mm
29235 sq. mm
29350 sq. mm
29470 sq. mm
29595 sq. mm
296120 sq. mm
297150 sq. mm
298185 sq. mm
299225 sq. mm
300240 sq. mm
301300 sq. mm
302400 sq. mm
303500 sq. mm
304630 sq. mm
305Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:
30616 sq. mm
30725 sq. mm
30835 sq. mm
30950 sq. mm
31070 sq. mm
31195 sq. mm
312120 sq. mm
313150 sq. mm
314185 sq. mm
315225 sq. mm
316240 sq. mm
317300 sq. mm
318400 sq. mm
319500 sq. mm
320630 sq. mm
321CABLES:- Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab)
3221.5 sqmm
3232.5 sqmm
3244.0 sqmm
3256.0 sqmm
32610.0 sqmm
32716.0 sqmm
32825.0 sqmm
32935.0 sqmm
330Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)
33116.0 sqmm
33225 sqmm
33335 sqmm
33450 sqmm
33570 sqmm
33695 sqmm
337120 sqmm
338150 sqmm
339185 sqmm
340240 sqmm
341300 sqmm
342400 sqmm
343Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)
34416 sqmm
34525 sqmm
34635 sqmm
34750 sqmm
34870 sqmm
34995 sqmm
350120 sqmm
351150 sqmm
352185 sqmm
353240 sqmm
354300 sqmm
355400 sqmm
356500 sqmm
357630 sqmm
358Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)
35925 sqmm
36035 sqmm
36150 sqmm
36270 sqmm
36395 sqmm
364120 sqmm
365150 sqmm
366185 sqmm
367240 sqmm
368300 sqmm
369400 sqmm
370500 sqmm
371630 sqmm
372WIRING:- Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab)
3731.0 sqmm
3741.5 sqmm
3752.5 sqmm
3764.0 sqmm
3776.0 sqmm
37810.0 sqmm
37916.0 sqmm
3802x1.5 sqmm
3812x2.5 sqmm
3822x6 sqmm (Aluminium unarmoured)
383CONDUITS:- Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings
384Providing and fixing uPVC trunking 25x16mm with allied fittings
385Providing and fixing Polypropylene Corrugated flexible conduit
38625mm
38732mm
388Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required.
389100 x 50 x 1.6mm
390150 x 50 x 1.6mm
391ELECTRICAL FITTINGS:- Providing and fitting of various electrical fittings as under (Preferred makes: Anchor/ SSK/ Havells)
392Switch-6A-SP-1way, 240V, 50 Hz, AC.
393Switch-6A-SP-2way, 240V, 50 Hz, AC.
394Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push.
395Bell push 240V, 50 Hz, AC.
3966A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC.
397Neon indicator
398Mini telephone jack
399Fan regulator (Mini) with rotary step
400Fan regulator (Deluxe) with rotary step
401Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC.
402Plug Top 15/16A 3 Pin (ISI Marked)
40332A TP switch 415V with neon
40432A DP switch 240V with neon
405Surface mounting box for switches as follows:
4061 Gang box
4072 Gang box
4083 Gang box
4094 Gang box
4105 Gang box
4116 Gang box
4127 Gang box
4134 Gang box (double domestic)
414Providing, Fixing, Testing of 6A ceiling rose
415Providing and installation of Pendant/ angle/ batten holders 6A 240V
416Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo)
4174 way
4188 way
41912 way
42016 way
421Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider)
4226-32A SP
42340A SP
4246-32A DP
42540A DP
426100A 4P isolator
427Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T)
4282-pole 16A 415V
4292-pole 32A 415V
4304-pole 32A 415V
4314-pole 63A 415V
4324-pole 100A 415V
433Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T)
43463A 415V
435100A 415V
436200A 415V
437Providing and installation of various type of fans as under: (Preferred makes: Havells/ Orient/ Crompton)
438Industrial exhaust fan 450mm metallic
439Exhaust fan 250mm Plastic
440Ceiling fan 1200mm sweep
441Wall fan 300mm sweep
442ILLUMINATION:- LED Bulbs withE27 or B22 base and illumination 3000K/ 5700K/ 6500K (Preferred makes: Havells/ Philips/ Osram/ Eveready/ Crompton/ Syska/ Bajaj/ Andslite)
4430.5W
4445W
4459W
44615W
447Providing and fitting of Open Construction (OC) Ballast for HID Lamps - 240V 50Hz
4481x70W SON/MH
4491x150W SON/MH
4501x250W SON/MH
451Providing and fitting of Ignitor for HID lamps 70 - 400W
452Providing, fixing and testing of various types of lamps as under: (Preferred makes: Havells/ Philips/ Osram Ledvance/ Bajaj):- Tungston linear halogen lamp
453500W
4541000W
455Metal Halide Lamp
45670W/ 150W Single ended clear Tubular (MH SET)
457250W/ 400W Single ended clear Tubular(MH SET)
45870W/ 150W Double ended
459High Pressure Sodium Vapour clear Tubular Lamp (SON-T)
46070W
461150W
462250W
463400W
464High Pressure Sodium Vapour Elliptical Coated Lamp (SON-E)
46570W
466PORTABLE LIGHTING:- 3 W Rechargeable LED torch (Preferred make: Havells/ Eveready/ Andslite/ Philips/ Syska)
467LED Lantern with Twin Charging mode –Charging Cable & Solar Panel (included) (Syska/ Havells/ Andslite/ Philips/ Bajaj)
468Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under:
469Brass
470Aluminium
471Copper
472Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under:
473Brass
474Aluminium
475Copper
476credit value for scrap Copper to be deducted and read as negative
477credit value for scrap Aluminum to be deducted and read as negative
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail