Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared) |
| 2 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. |
| 3 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof. above 150 mm. thick |
| 4 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required completeEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. |
| 5 | Depth exceeding 1500mm & upto 3000mm |
| 6 | Supplying Eucalyptus-bullah piles at work site,including dressing and making one end pointed. (iii) 150mm diameter |
| 7 | Labour for driving Sal-bullah / Eucalyptus bullahpiles by monkey in sorts of soil including hoisting andplacing piles in position, protecting the pile headwith iron ring and cutting and shaping heads beforeand after driving and including hire and labour fornecessary driving appliances and all tackles.iii) 150mm diameter |
| 8 | Coal tarring on wooden surfaces including cost ofmaterials (a) Double coat. |
| 9 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(B) Do - by fine sand |
| 10 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety For Ground Floor |
| 11 | For 1st floor |
| 12 | For 2nd floor |
| 13 | For 3rd floor |
| 14 | For 4th floor |
| 15 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer\"s specified rate) for concrete of various grades. |
| 16 | Reinforcement for reinforced concrete work inall sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. i)For M.S. Rounds / Tor Steel / H.Y.S.D. Bars TATA/SAIL/RINL Ground floor |
| 17 | For 1st floor |
| 18 | For 2nd floor |
| 19 | For 3rd floor |
| 20 | For 4th floor |
| 21 | Hire and labour charges for shuttering with centering and necessary staging upto 4.00 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (C) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.Ground floor |
| 22 | For 1st floor |
| 23 | For 2nd floor |
| 24 | For 3rd floor |
| 25 | For 4th floor |
| 26 | Brick work with 1st class bricks in cement mortar(1:6) . In Superstructure , Foundation, basement all floor, Roof & above.In Foundation and plinth ground floor |
| 27 | 250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge.In Superstructure, ground floor |
| 28 | For 1st floor |
| 29 | For 2nd floor |
| 30 | For 3rd floor |
| 31 | For 4th floor |
| 32 | 125 mm thick Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I,having drying Shrinkage less than 0.05% conforming to IS: 2185 ( Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981with permissible loss on ignition upto 6%), lime , cement and complete in all respect as per direction & satisfaction of Engineer -in Charge . |
| 33 | For 1st floor |
| 34 | For 2nd floor |
| 35 | For 3rd floor |
| 36 | For 4th floor |
| 37 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.Ground floor |
| 38 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ground floor |
| 39 | For 1st floor |
| 40 | For 2nd floor |
| 41 | For 3rd floor |
| 42 | For 4th floor |
| 43 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant ISodes. (i) Pakur Variety5th floor |
| 44 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety, Ground floor, |
| 45 | Supplying and laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks(with Concrete grade as specified as per Table I of IS 15658 : 2006) manufactured from BIS license manufacturer , with spacer nib (small protruding profiles on the vertical face of a paver block used as a divece for keeping minimum joit gap in between the paving blocks, as per CL. No.3.26 of IS: 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per Cl. no.3.3 of IS : 15658) as per table 2 of IS: 15658 with flexurl strength / breaking load as per Annexure G of IS:15658, on the prepared base course of specified CBR as per table 1 of IRC SP63 (2018) or else us mentioned design and drawiing with a cushion of compacted bedding sand of 25-35 mm. thick (grading of bedding as per clause 6.51 of IRC SP63) and fitting up the gapes in between paver blocks with joint filling sand (the grading of joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl.no.8.7 of IRC SP-63 (2018) with proper confinement of bedding and joint filling sand, compaction, leveling and filling up of the edge gap. 60 mm. thick(ii) Colour Decorative |
| 46 | Supplying and laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks(with Concrete grade as specified as per Table I of IS 15658 : 2006) manufacturedin steel mould clamped to a vibrating table by hydraulic pressure(as per cl. no. 6.30 of IRC:SP:63(2018) from BIS license manufacturer , with spacer nib (small protruding profiles on the vertical face of a paver block used as a divece for keeping minimum joit gap in between the paving blocks, as per CL. No.3.26 of IS: 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per Cl. no.3.3 of IS : 15658) as per table 2 of IS: 15658 with flexurl strength / breaking load as per Annexure G of IS:15658, on the prepared base course of specified CBR as per table 1 of IRC SP63 (2018) or else us mentioned design and drawiing with a cushion of compacted bedding sand of 25-35 mm. thick (grading of bedding as per clause 6.51 of IRC SP63) and fitting up the gapes in between paver blocks with joint filling sand (the grading of joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl.no.8.7 of IRC SP-63 (2018) with proper confinement of bedding and joint filling sand, compaction, leveling and filling up of the edge gap. 80 mm. thick(ii) Colour Decorative |
| 47 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety](a) 1:3:6 proportion Ground floor |
| 48 | Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]30 mm. thick |
| 49 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointedwith white cement slurry @ 2.0 kg/Sq.m with necessarypigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {Whitecement and Pigment to be supplied by the Agency](b) With Chawk Dungri (ii) Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 sq.m. Ground floor |
| 50 | 1st floor |
| 51 | 2nd floor |
| 52 | 3rd floor |
| 53 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone. |
| 54 | Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry@ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment to be supplied by thAgency](b) With Chawk Doongri (ii) Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 Groundfloor |
| 55 | 1st floor |
| 56 | 2nd floor |
| 57 | 3rd floor |
| 58 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 59 | Plastering (in wall , floor , ceiling etc. ) with sand and cement mortar including rounding off or chamfering corners as directed and racing out joints or roughening of concrete surface including throating and nosing & drip course where necessary. ( A ) With 1:6 cement morter, 20mm thick plasterGround floor |
| 60 | (B ) With 1:6 cement morter, 15 mm thick plasterGround floor |
| 61 | (B ) With 1:4 cement morter, 10 mm thick plaster,,n celling |
| 62 | 1st floor (Internal wall)With 1:6 cement morter, 20mm thick plaster |
| 63 | 1st floor With 1:6 cement morter, 15mm thick plaster(Outer wall) |
| 64 | 1st floor (c) With 1:4 cement morter, 10 mm thick plaster, in celling |
| 65 | 2nd floor (Internal wall)with 1:6 cement morter, 20 mm thick plaster, Internal wall |
| 66 | 2nd floorwith 1:6 cement morter, 15 mm thick plaster, outer wall |
| 67 | 2nd floor(c)with 1:4 cement morter, 10 mm thick plaster, in celling |
| 68 | 3rd floor(Internal wall) with 1:6 cement morter, 20 mm thick plaster, internal wall |
| 69 | 3rd floor with 1:6 cement morter, 15 mm thick plaster, outer wall |
| 70 | 3rd floor with 1:4 cement morter, 10 mm thick plaster, in celling |
| 71 | 4th floor (Internal wall)with 1:6 cement morter, 20 mm thick plaster, internal wall |
| 72 | 4th floor with1:6 cm, 15 mm thick plaster other wall |
| 73 | 4th floor with 1:4 cement morter, 10 mm thick plaster, in celling |
| 74 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. |
| 75 | Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303-1989 bonded with phenol formaldehyde synthetic resin of approved make andbrand fitted and fixed as per design as per approval and direction of Engineer-in-Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] 19 mm |
| 76 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm |
| 77 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.In ground floor.(i) 32 mm thick |
| 78 | For 1st floor |
| 79 | For 2nd floor |
| 80 | For 3rd floor |
| 81 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)(ii) 4 mm thick |
| 82 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in(ii) Grill weighing above 16 Kg./sq.mtr and above Ground floor |
| 83 | In 1st floor |
| 84 | For 2nd floor |
| 85 | For 3rd floor |
| 86 | For 4th floor |
| 87 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10 - 12 Micron thickness, anodizing fillm natural white |
| 88 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall - with sand cement morter (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint fillingusing white cement slurry @ 0.20Kg/ Sqm. Area of each tile above 0.09 sq.m.ColouredDecorative.Ground floor |
| 89 | In 1st floor |
| 90 | For 2nd floor |
| 91 | For 3rd floor |
| 92 | (A) Floor ,with sand cement morter (1:4), 20 mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint fillingusing white cement slurry @ 0.20Kg/ Sqm.Ground floor area of each tile above 0.09 m2 coloured decorative |
| 93 | In 1st floor |
| 94 | For 2nd floor |
| 95 | For 3rd floor |
| 96 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (ii) Sal : LocalGround floor |
| 97 | In 1st floor |
| 98 | For 2nd floor |
| 99 | For 3rd floor |
| 100 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.Ground floor |
| 101 | Ordinary Teak wood |
| 102 | (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak (4th floor) |
| 103 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vii) 100mm. X 58mm. X 1.90mm. |
| 104 | (iv) 75 mm. X 47mm. X 1.70mm. |
| 105 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod) (vi) 150 mm grip x 10 mm dia rod. |
| 106 | Door stopper.(Brass) |
| 107 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 32 mm thick shutters (single leaf)In 1st floor |
| 108 | For 2nd floor |
| 109 | For 3rd floor |
| 110 | Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.300mm long. |
| 111 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.250mm long. |
| 112 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded sectionnforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 300mm long x 10mm dia. bolt. |
| 113 | 150mm long x 10mm dia. bolt. |
| 114 | (a) Supplying \"Godrej\" mortice lock chromium plated with latch and keys 4 levers,including fitting and fixing complete. |
| 115 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels00mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cementoncrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. Ground floor |
| 116 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) |
| 117 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 118 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.One coatsIn Ground Floor |
| 119 | In 1st floor |
| 120 | For 2nd floor |
| 121 | For 3rd floor |
| 122 | For 4th floor |
| 123 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. c) Super Protective 100% Acrylic Emulsion In Ground Floor (Two coat) |
| 124 | In 1st floor |
| 125 | For 2nd floor |
| 126 | For 3rd floor |
| 127 | For 4th floor |
| 128 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick).Ground floor |
| 129 | In 1st floor |
| 130 | For 2nd floor |
| 131 | For 3rd floor |
| 132 | For 4th floor |
| 133 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Solvent based interior grade Acrylic Primer |
| 134 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :( Two coats)i) Standard Quality Ground floor to 6th floor |
| 135 | (a) Priming one coat on steel or other metals surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 136 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 137 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :Withhi-gloss of approved quality- - Two coats (with any shade except white) |
| 138 | (B) On steel or other metal surface : Withhi-gloss of approved quality-Two coats (with any shade except white) |
| 139 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn,lamoid/Bitumen/M-Seal etc) complete.UPVC Pipes(A) 110 mm. dia |
| 140 | (a) plain Tee 110 mm |
| 141 | (b) plain Y 110 mm |
| 142 | (c)Bend 87.5 degree 110 mm |
| 143 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)Exposed work 15 mm. medium quality |
| 144 | 20mm Medium quality |
| 145 | 25mm Medium quality |
| 146 | 40 mm Medium quality |
| 147 | 50 mm Medium quality |
| 148 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 Single Socketed 3 Meter Length, (b) 110 mm |
| 149 | (c ) 160 mm. |
| 150 | ( c) Plain Tee - (a) 110 mm |
| 151 | (a) 160 mm |
| 152 | (D) Bend 87.5 degree (a) 110 mm |
| 153 | (b) 160 mm |
| 154 | Supplying, fitting and fixing Peet\"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).(viii) 20 mm. dia |
| 155 | (Vii) 25 mm. dia |
| 156 | (v) 40 mm. dia |
| 157 | (iv) 50 mm dia |
| 158 | (iii) 65 mm. dia |
| 159 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar). |
| 160 | (b) Supplying, fitting and fixing bib cock or stop cock.(i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar). |
| 161 | Supplying, fitting and fixing shower of approved brand and make. Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 162 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to racket etc. |
| 163 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2500 liter capacity |
| 164 | Labour for hoisting plastic water storage tank. Above 1500 Litre Upto5000 litre capacity.( 5th Floor) |
| 165 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 166 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.Size- 550mm X 400mm |
| 167 | Supplying, fitting and fixing pillar cock of approved make.f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand). |
| 168 | Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.900mm long |
| 169 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.900mm long |
| 170 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.With \"S\" trap |
| 171 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).Size- 450mm X 350mm |
| 172 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.E.W.C ,Plastic ( Hallow type )White |
| 173 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.635 mm X 395 mm X 420 mm each |
| 174 | Supplying, fitting and fixing porcelain soap tray of approved make.(i) Recessed soap tray of size 150 mm X 150 mm470 mm X 280 mm X 340 mm |
| 175 | Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front cornersrounded and edges polished. |
| 176 | Supplying, fitting and fixing towel rail with two brackets. (ii) 25 mm dia. and 600 mm long |
| 177 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 178 | Supplying, fitting and fixing glass shelf with aluminium guard rails.Ordinary type with 5.5 mm sheet glass, 600 mm X 125 mm |
| 179 | Supplying, fitting and fixing soap holder.PTMT (Prayag or equivalent) |
| 180 | Supplying, fitting & fixing Aluminium domical grating.100 mm |
| 181 | Supplying, fitting & fixing H.C.I. bend without door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (a) With valamoid joints including sealing the top with cement mortar (4:1)100mm dia |
| 182 | A). Supplying, fitting & fixing Vent Cowl 110 mm |
| 183 | B). Supplying, fitting & fixing Vent Cowl 75 mm |
| 184 | A) Supplying fitting & fixing pipe clip 110mm |
| 185 | B) Supplying fitting & fixing pipe clip 75mm |
| 186 | Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.(b) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre). (i) First 50 metre |
| 187 | (ii) Next 50 metre |
| 188 | (ii) Next 50 metre |
| 189 | (ii) Next 50 metre |
| 190 | Supplying, fitting and fixing PVC pipes for underground work of approved make (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads , cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect PVC Pipes -150 mm Dia |
| 191 | PVC Pipes - 250 mm Dia |
| 192 | Supplying, fittings, fixing G.I. cap at top.(iv) 300mm |
| 193 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (v) 150mm dia |
| 194 | Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge.(ii) 150 mm |
| 195 | Supplying, fittings, fixing heavy type bell mouth reducing socket. (v) 200 mm. x 250 mm. |
| 196 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 197 | Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. |
| 198 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 199 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete. |
| 200 | Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. |
| 201 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. |
| 202 | Providing 200 mm centre guide.i) With Clamp |
| 203 | Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. |
| 204 | Supplying and laying 4 sq.mm 3 core flat copper PVC submersible cable from starter and controlling panel to the submersible Pump with necessary connection. ( M- Finolex, Product code - 17203)Rate approv. byElect. Deptt. |
| 205 | Supplyand installlation of440 Volts 2900 R.P.M., 5.00 H.P, submersible Pumpmotor set ( make -K.S.B), Model No. BPD 262/%A +UMAI/ 150 - 3/22 into the tube well including errection of tripoid stand by companies own tools & tackles. Rate approv. byElect. Deptt. |
| 206 | Supply & installation of 5 H.P. ( 440V) 2900 R.P.M monoblock submersible pump motor set ( Make- Kirloskar) by tools & trackles & manual labour. ( model No.- KOS-538+) |
| 207 | Supply & fitting of 415 V, 3 Ph, MU-G10W DOL within-built WLC Pump controller Stater Relay range(9-14) suitable size for 7.5 HP Submersible Pumpmotor set ( Make - L&T, Model HSN code 8536) on common angle iron frame on wall including nuts bolts etc. including connecting wire. |
| 208 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 &ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer\"s specification on smooth, clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: |
| 209 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336,tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.In ground floora) False Ceiling (with 4mm thick Fibre Cement Standard Ceiling Board and EGridT-2430/1510). |
| 210 | (FIRE FIGHTING) (Rates for estimate)Supply, erection, testing & commissioning of Electrical Motor driven main pump, centrifugal horizontal type, with gland packing capable of deliver 2850 LPM at 88 MWC. The pump shall be coupled with TEFC motor of suitable KW with speed of 2900 RPM with all accessories and complete set shall mounted on common base frame. The quoted rate shall include fixing of coupling, coupling guard and foudation bolts etc. Civil foundation will be client\"s scope. |
| 211 | Supply, erection, testing & commissioning of electric motor driven Jockey Pump, horizontal, centrifugal type capable to deliver 180LPM at 88 MWC. The pump shall coupled to TEFC motor of suitable KW with speed of 2900 RPM with all accessories mounted on common base fframe. |
| 212 | Supply, erection, testing & commissioning of compartmentalised common control panel for Electrical Motor driven pumpsas per technical specification attached with this tender document. All components shall be housed in a common cubicals made of 16 swg. M.S. sheet with required stiffners(if required). The panel shall be powder quoted of approved colour both inside and out side. The pane shall have both bottom and top cable entry provisions and panel shall be mounted on pedestal of 300mm height. The panel should have sufficient(min. 6 nos per pump set) NO / NC contaacts for extending the status of fire pumps to the fire alarm panel. |
| 213 | Supply, erection, fabrication, testing of MS black steel pipe Heavy grade conforming to IS : 1239 Part -1 /3589 including all fittings viz. Elbows, tees, flanges, etc. reduces clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the complete with cutting and making good the walls, floors or any other surface (For pumping system )250 mm NB x 6 mm thk |
| 214 | 200 mm NB x 6 mm thk |
| 215 | 150 mm NB |
| 216 | 100 mm NB |
| 217 | 80 mm NB |
| 218 | 65 mm NB |
| 219 | 25 mm NB |
| 220 | Supply, installation, testing & commissioning of CI Gate Valve as pe IS:14846 (PN 16) with matching flanges complete with nuts & bolts.Size 200 mm NB |
| 221 | Size 150 mm NB |
| 222 | Size 80 mm NB |
| 223 | Size 65 mm NB |
| 224 | Supply, instaallation, testing & commisssioning of swinging type CI Non return Valve as per IS:5312(PN16 rating)with disc and SS hinges complete including matching flanges, nuts & bolts complete. size 150mmNB |
| 225 | Size65 mm NB |
| 226 | Supply, installation, testing & commissioning ofCI Globe Valveas per IS:9338(PN10 rating) complete including matching flanges, nuts & bolts complete.Size25 mm NB (GM construction) |
| 227 | Supply & installation of Gunmetal 4 way collecting head with 63 mm dia instantaneous type inlet 150 dia flanged outlet without built in check valve for fire brigade connection to fire water reservoir (IS : 904) with one no. butterfly valve & NRV of 150NB size. |
| 228 | HYDRANT SYSTEM Supply, erection, testing of MS black steel pipe Heavy Gradeconforming to IS : 1239Part - 1/3589 including all fittings viz. Elbows, tees, flanges, etc. reduces, clamps, included with joints complete with anticorrosive treatment to burried pipes by wrapping with two coats of 4mm thick PYPKOTEmembrane applied over a coat of primer for external yard hydrant network.150 mm NB |
| 229 | 80 mm NB |
| 230 | Supply, erection, fabrication, testing of MS black steel pipe Heavy grade conforming to IS : 1239 Part -1 /3589 including all fittings viz. Elbows, tees, flanges, etc. reduces clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the complete with cutting and making good the walls, floors or any other surface (Forhydrant system inside building & outside building to laid along with boundary wall) 150 mm NB |
| 231 | 80 mm NB |
| 232 | 25 mm NB |
| 233 | Supply and installtion of swinging type CI Non return Valveas per IS:5312 with flap and SS hinges complete including matching flanges, nuts & bolts confirming to IS 5312 Size 150 mm NB |
| 234 | Supply, installation, testing & commissioning of CI Gate Valve as pe IS:14846 (PN 16) with matching flanges complete with nuts & bolts.Size 150 mm NB |
| 235 | Supply, installation of Globe Valves in Gun Metal Construction to IS: 778 with screwed ends 25 NB size |
| 236 | Supply, installation of automatic 25 NB Air Release Valve |
| 237 | Supply & installation of GM oblique type single headed Hydrant valve with 80 mm inlet and 63 mm outlet GM instantaneous male coupling with rubber cap and chain conforming to IS : 5290 including matching flanges, gasket, nuts and bolts complete. |
| 238 | Supply & installation of gunmetal branch pipe with 20 mm nozzle conforming to IS : 903 complete |
| 239 | Supply & installation of 63 mm dia rubberized reinforced rubber line hose pipe in 15 m length conforming to IS : 636 Type II ISI marked with gunmetal male and female instantaneous coupling conforming to IS 903 wounded with 18 SWG copper wire complete |
| 240 | Supply & installation of MS hose box of fabricated from 16 SWG CRCA sheet double door with lockable arrangements to accommodate 2 RRL hose of 15 m length and one branch pipe painted white inside and red outside with one key. (750x600x250 mm) |
| 241 | Supply & installation of swinging type hose reel drum fabricated from 14 SWG CRCA sheets painted with red colour stove paint 2 coats over 1 coat of primer with 30 m long 20 mm dia rubber hose pipe with 10 kg/sq cm working pressure with GM self closing shut – off nozzle of 5 mm outlet fixed on wall with dash fasteners. |
| 242 | Supply & installation of Gunmetal 2 way collecting head with 63 mm dia instantaneous type inlet 150 dia flanged outlet with built in check valve for fire brigade connection to fire riser (IS : 904) with one no. butterfly valve & NRV of 150NB size |
| 243 | Supply & installation of Gunmetal 3 way collecting head with 63 mm dia instantaneous type inlet 150 dia flanged outlet without built in check valve for fire brigade connection to fire water reservoir (IS : 904) with one no. butterfly valve & NRV of 150NB size. |
| 244 | Gun metal gate valve 25NB |
| 245 | AUTOMATIC SPRINKLER SYSTEM Supply, fabrication, erection & testing of MS black steel pipe Heavy grade conforming to IS : 1239/3589 including all fittings viz. Elbows, tees, flanges, etc. reduces clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the complete with cutting and making good the walls, floors or any other surface 150 mm NB |
| 246 | 40 mm NB |
| 247 | 25 mm NB |
| 248 | Providing & fixing Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts.Size 150mm NB |
| 249 | Providing & fixingnone return valve (wafer type )with matching flange complete with nuts and bolts.Size 150mm NB |
| 250 | Supply & installation of Globe Valves in Gun Metal Construction to IS: 778 with screwed ends Size 40mm NB |
| 251 | Supply & fixing of Sprinkler Head Pendent type |
| 252 | Supply & fixing of 150NB Flow Switch |
| 253 | Supply & fixing of Installation Control Valve complete with trims & gong.ground level |
| 254 | Supply, installation, testing & commissioning of CI Gate Valve as pe IS:14846 (PN 16) with matching flanges complete with nuts & bolts.Grounr level |
| 255 | Supply, installation of automatic 25 NB Air Release Valve.Ground level |
| 256 | PORTABLE EXTINGUISHERS Supply & fixing of 5 Kg dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle & CO2 cartage and hanging arrangement completeconforming to IS:2171 |
| 257 | Supply & fixing of 9 Litre Water type CO2 (ISI marked) extinguisher including all accessories with wall bracket & raw plug conforming to IS:940, stair landing |
| 258 | Providing & fixing 6.8 Kg CO2 type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:10204 |
| 259 | Providing & fixing 10 kg sand bucket (ISI marked) including all accessories, support, stand etc |
| 260 | SIGNAGES Supply and installation in position the \"FIRE EXIT\" Sign with luminicent colour having size 300 x 100 mm, gr floor to 3 rd floor stair |
| 261 | Supply and fixing in position the signages \" FIRE ORDER\" contain the following matter on 3 mm thick \"Opaque\" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of size 1200 x 1000 mm. |
| 262 | Supply and fixing signage with printed \" IN CASE OF FIRE,DO NOT USE LIFT. USE STAIRS ONLY\" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point. |
| 263 | Supplying, fitting and fixing 10.00 H.P KOS- THREE PHASE SUBMERSSIBBLE MONOBLOC PUMPSETS (SYNC.SPEED-3000 rpm BRAND: KOS, MODEL NO.1050+ , CODE:D12311000351 WITH MOTOR RATING-10.0 H.P(7.5 KW.) ,SIZE(mm)-65(SUC) X 65(DEL) complete in all respect as per direction of E.I.C. |
| 264 | PLINTH PROTECTIONEarth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming thesides of trenches, levelling, dressing and ramming thebottom, bailing out water as required complete Depth of excavation not exceeding 1,500 mm. |
| 265 | Removal of Unserviceable Soil with Disposal upto 1000metres Removal of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per Technical Specification Clause 302.3.11 for Rural Roads of MORD. (Mode of measurement: pre works and post works |
| 266 | (A) Filling in foundation or plinth by fine sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 267 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or infoundation or in foundation trenches. |
| 268 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(A) [Pakur Variety] 1:3:6 proportion |
| 269 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor a) Pakur Variety |
| 270 | Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3)complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling |
| 271 | SURFACE DRAIN Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming thesides of trenches, levelling, dressing and ramming thebottom, bailing out water as required complete Depth of excavation not exceeding 1,500 mm. |
| 272 | Removal of Unserviceable Soil with Disposal upto 1000metres Removal of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per Technical Specification Clause 302.3.11 for Rural Roads of MORD. (Mode of measurement: pre works and post works |
| 273 | (A) Filling in foundation or plinth by fine sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 274 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(A) [Pakur Variety] 1:3:6 proportion |
| 275 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stou props and thick hard wood planks of approved etc.c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. a) Ground Floor |
| 276 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement ------- M 25 Grade |
| 277 | Reinforcement for reinforced concrete work inall sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. i)For M.S. Rounds / Tor Steel / H.Y.S.D. Bars JSW/JSPL/SHYAM/SRMBGround floor |
| 278 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging wherenecessary (Ground floor). (i) With 1:6 cement mortar 15 mm thick Gr. floor |
| 279 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. |
| 280 | WATER TANK Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming thesides of trenches, levelling, dressing and ramming thebottom, bailing out water as required complete Depth of excavation not exceeding 1,500 mm. |
| 281 | Depth of excavation for additional depth beyond1,500 mm. and upto 3,000 mm. but not requiringshoring. |
| 282 | (A) Filling in foundation or plinth by fine sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 283 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(A) [Pakur Variety] 1:3:6 proportion |
| 284 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement ------- M 25 Grade |
| 285 | FORFIRST FLOOR |
| 286 | FORSECOND FLOOR |
| 287 | FORTHIRD FLOOR |
| 288 | FORFOURTH FLOOR |
| 289 | FORFIFTH FLOOR |
| 290 | Reinforcement for reinforced concrete work inall sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. i)For M.S. Rounds / Tor Steel / H.Y.S.D. Bars TATA/SAIL/RINL Ground floor |
| 291 | 1st.Fl. |
| 292 | 2nd.Fl. |
| 293 | 3rd.Fl. |
| 294 | 4th.Fl. |
| 295 | 4th.Fl. |
| 296 | (a) Hire and labour charges for shuttering for concrete work in overhead R.C. Reservoir on separate R.C. frame including fitting, fixing and striking off after compeltion of work including staging upto 4 m using ply board or steelshuttering |
| 297 | Extra for Staging beyond 4 m [mode of measurement: Area of unsupported horizontal projection (where staging beyond 4 m is practically unavoidable)x mean height of staging] above initial 4m |
| 298 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging wherenecessary (Ground floor). (i) With 1:6 cement mortar 20 mm thick Gr. Fl. |
| 299 | 1st. Fl. |
| 300 | 2nd. Fl. |
| 301 | 3rd. Fl. |
| 302 | 4th. Fl. |
| 303 | 5th. Fl. |
| 304 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m |
| 305 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EICGr. Fl. |
| 306 | 1st Fl. |
| 307 | 2nd. Fl. |
| 308 | 3rd. Fl. |
| 309 | 4th. Fl. |
| 310 | 5th. Fl. |
| 311 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conformingto IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidentalchages such as electricity charges, labour insurance charges etc.III) For built up sections / srtuctural members of specified sectionsweighing not less than 22.5 Kg./m |
| 312 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer\"s specification.Gr. Fl. |
| 313 | 1st Fl. |
| 314 | 2nd. Fl. |
| 315 | 3rd. Fl. |
| 316 | 4th. Fl. |
| 317 | 5th. Fl. |
| 318 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line includingall specials. No separate payment will be made for accesories, specials. For Exposed Work (i) CPVC Pipes Class-1, SDR-1150 mm dia. |
| 319 | FOR CONCRETE ROAD PAVEMENT (3.75 M WIDE ) Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 320 | Removal of Unserviceable Soil with Disposal upto 1000metresRemoval of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per Technical Specification Clause 302.3.11 for Rural Roads of MORD. (Mode of measurement: pre works and post works |
| 321 | (A) Filling in foundation or plinth by fine sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 322 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or infoundation or in foundation trenches. |
| 323 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor a) Pakur Variety |
| 324 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement ------- M 25 Grade |
| 325 | Reinforcement for reinforced concrete work inall sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. i)For M.S. Rounds / Tor Steel / H.Y.S.D. Bars JSW/JSPL/SHYAM/SRMBGround floor |
| 326 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stou props and thick hard wood planks of approved etc. c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. a) Ground Floor |
| 327 | Sewerage line ,septic tank , soack well, inspection pitConstructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of thetop slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (i) 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved makeA) With Pakur variety. (JSW/JSPL/SHYAM) |
| 328 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to insidewalls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaceWith Pakur variety. ((JSW/JSPL/SHYAM) |
| 329 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% byweight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 200 usersWith Pakur variety. ((JSW/JSPL/SHYAM) |
| 330 | Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides).300 mm |
| 331 | Supplying, fitting and fixing with cement jointing (3:1) with jute gasket soaked in cement mortar.Stoneware bend 300 dia |
| 332 | Stoneware single T or Y junction |
| 333 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour andmaterials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.((JSW/JSPL/SHYAM) |
| 334 | LAND DEVELOPMENTEarth work in filling in compound, tank, low land,ditches etc. with good earth, in layers not exceeding150 mm. including breaking clods and consolidatingthe same by ramming and dressing complete.(Payment will be made on profile measurement beforeand after the work) iii) With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 335 | ELECTRICALWORKSSupply and Installation of Cubical panel suitable for 415V, 50 HZ, AC , 3 Phase and neutral system,made from CRCA MS sheet metal (14 SWG) incorporated the following main switches with IP-42/43 protection. The panel should have necessary interconection with incoming and outgoing main switch with busbar by suitable size of conductor and proper earthing attachment.The panel should be powder coated painted and all necessary Shrouds,Cable terminals, Nut-bolts and required accessories. (Make: Approved make of P.W.D.) Incoming : 630A, 415V TPN SFU with propet HRC fuse (open execution type) --- 1 no.Change Over Switch: 630A, 415V TPN On-LoadFront operated (open execution type)--- 1 no.Busbar Chamber with 4 nos. 1000A capacity Al. Bus.Outgoing : i)63A, 415V TPN SFU with propet HRC fuse(open execution type)---- 5 nos.ii) 160A, 415V TPN SFU with propet HRC fuse(open execution type)---- 2 nos.iii) 250A, 415V TPN SFU with propet HRC fuse(open execution type)---- 3 nos. Digital Multifunction Meter with selector switch --- 1 no.R,Y,B indicating lamp --- 6 nos.C.T. coil 100A/5A (0.5s class) --- 3 nos. Danger Board --- 2 no.Make: L&T,ABB,C&S,HPL(NS) |
| 336 | Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 150x50x1.25mm (18SWG). |
| 337 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(upto 160A-4way)[D-11/15] Make: LEGRAND, ABB, SIEMENS, |
| 338 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(upto 250A-8way)[D-11/15], Make :LEGRAND, ABB, SIEMENS, |
| 339 | Supplying and fixing MCB SS enclosure with IP-20/30protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (4way) For UPS (D9/11) |
| 340 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (8way) [D-10/14], Make: LEGRAND, ABB, SIEMENS, . |
| 341 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (2+12Way)[D9/13], Make: LEGRAND, ABB, SIEMENS, |
| 342 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (2+16Way) For UPS. [D9/13], Make: LEGRAND, ABB, SIEMENS, |
| 343 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (8 way) [D-12/16], Make: LEGRAND, ABB, SIEMENS, |
| 344 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontalenclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (8 way)[D-12/16], Make: LEGRAND, ABB, SIEMENS, |
| 345 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (160A-FP)[D-8/10], Make :- LEGRAND, ABB, SIEMENS, |
| 346 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection(250A-FP)[D-8/10], Make:Legrand, , ABB, SIEMENS, |
| 347 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [D-6/7],Make:Legrand,SIEMENS,,ABB, TP(63A)For VTPN outgoing |
| 348 | SP(40A) For HTPN Outgoing |
| 349 | SP(40A) For Outgoing |
| 350 | SP(6-32A) For Outgoing |
| 351 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection. (D-5/6), Make:Legrand,Schneider,ABB,CrabtreeFP(80A) For HTPN Incoming |
| 352 | DP(63A) For Incoming |
| 353 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.--2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Average run 9 mtr |
| 354 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish--2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board |
| 355 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 356 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.[E-7/25] |
| 357 | Supply and delivery of Twin LED Fitting (2 X 20Watt, 230VAC, 50hZ,4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 2 nos LED Tube [Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, / Jaquar. With 3 years warranty al heat sink |
| 358 | Supply and delivery of Single LED Fitting (20Watt, 230VAC, 50hZ,4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube [Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, / Jaquar.With 3 years warranty al heat sink |
| 359 | Supply and Fixing of Round recess mounted LED light (18Watt, 230VAC, 50hZ,4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories.Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, / Jaquar.With 3 years warranty |
| 360 | Supply and Fixing of Square recess mounted LED light (18Watt, 230VAC, 50hZ,4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube [Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, LEGARO, With 3 years warranty |
| 361 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[C-2/17] |
| 362 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with supplied clamps with LED tube lights on HW block or plates, nipples etc. as required as per direction of the EIC. (C2/14c) |
| 363 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. (C2/16) |
| 364 | Supply and delivery of 230V 1200mm sweepceiling fan (28Watt or less BLDC fan, class of insulation -\"B\", SERVICE VALUE (CMM/W minimum 6.85, R.P.M. 350(min), THD <10%, supplied with remote control or wall mounted speed regulator, P.F. not less than 0.9, bult in 2.5KV SPDwith complete accessories[Make: Usha, Crompton, Bajaj, Atomberg, Havells, Orients, CG, RR or equivalent ]With 3 years warranty |
| 365 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[C-3/21a] |
| 366 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.[C-3/21b] |
| 367 | Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)[D-14/30] |
| 368 | Supply and delivery of 230V 30cm(12\") Heavy Duty Exhaust fan with all necessary accessories [Make: EPC , Usha,CG,Bajaj or equivalent Make] |
| 369 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12\") [C-4/28] |
| 370 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) -- For Al -- 30 cm Exhaust fan (12\") [D-14/32a] |
| 371 | Supply and delivery of 1.1 KV grade, 4 Core 185 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables.[Make: UNIVERSAL, HAVELES, POLYCAB, RR KABLE ] |
| 372 | Laying of two cables above 35 sqmm and upto 185 sqmm in anunderground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed (F2/2b)Make: UNIVERSAL, HAVELES, POLYCAB, RR KABLE. |
| 373 | Supply and delivery of 1.1 KV grade, 4 Core 120 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables.[Make: UNIVERSAL, HAVELES, POLYCAB, RR KABLE |
| 374 | Laying of cable upto 4 core 120 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. Mending good damages and painting.(F1/2e) |
| 375 | Supply and delivery of 1.1 KV grade, 4 Core 70 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables.[Make: UNIVERSAL, HAVELES, POLYCAB, RR KABLE. |
| 376 | Laying of cable upto 4 core 70 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (F1/2d) |
| 377 | Supply and delivery of 1.1 KV grade, 4 Core 16 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables.[Make: UNIVERSAL, HAVELES, POLYCAB, RR KABLE. |
| 378 | Laying of cable upto 4 core 16 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (F1/2b) |
| 379 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as belowFor 4 Core upto 185 sqmm |
| 380 | For 4 Core upto 120 sqmm |
| 381 | For 4 Core upto 70 sqmm |
| 382 | For 4 Core upto 16 sqmm |
| 383 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials[F-5/8b-xii]For 4 Core upto 185 sqmm |
| 384 | For 4 Core upto 120 sqmm |
| 385 | For 4 Core upto 70 sqmm |
| 386 | For 4 Core upto 16 sqmm |
| 387 | Distribution wiring in 1.1 KV single core stranded \"FR\" , PVC insulated & unsheathed copper wirein 20mm size PVC rigid conduit \"FR\"incl. necy. fittings as required [E-14/1a] Make for wires :- RR Kable, Finolex, Polycab.2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 388 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 389 | 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 390 | Finishing of the PVC insulatedCopper wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 6 sqmm |
| 391 | 4 sqmm |
| 392 | 2.5sqmm |
| 393 | 1.5 sqmm |
| 394 | Supply and delivery of LED Street Light(230vac, 30w to 35Watt, 5500K, IP 66, THD<10%,bult in 2.5KV SPD) with all necessary connection.[Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, / Jaquar. With 5 years warranty |
| 395 | Fixing only outdoor / street light type fluorescent light fitting or MV/LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 396 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 397 | S&F Street light/Outdoor light/Compound Light Timer DB(Water Proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions ofEIC i) 240 V, 6-32 A FPMCB of breaking capacity 10KA & \"\"C\"\" Charecteristic-- 01 noii) 240V 6-32 A FP MCB Isolator on din rail--- 01 No.iii) 240V ,4P, Power Contractor (rating above 20 Amp) with accessories ----- 01 no L&T, MNXiv) Astronomical / Digital timer switch --- 01no L&T,v) Toggle switch for manual/auto operation--- 01no. vi)Stainless steel box with hoodand Rlay type locking arrangement 10 sqmm for power line, 1.5 sqmm 2mm for control wiring vii)Necessary connection by copper wire.[Make = ABB,Simens,Legrand,L&T or as per EIC] |
| 398 | Supply & Fixingstarters (for motor control) on flatiron frame / angle iron frame on wall On angle ironframe (for higher rating)--Direct on Line starter(415V) for motor (upto 5 HP) Make:L&T,BCH,Siemense L&T MUG-6] |
| 399 | Supplying & Fixing 240 V AC call bell push (Make :- Anchore, Havelles, C&S Goldmedal or approved by the EIC. ) on HW board incl. S&F HW board. |
| 400 | Supply Delivery & installation of hybrid combination call bell central system for 22 (Twenty Two) modules with individual indications and alarming system with manual reset for 22 (Twenty Two) different bell push inputs (push To on and auto reset installed at patint bed side supply and installation against seperate item above of this estamet) at the nurse station for callaing the nurses at the hospital. Make approved by EIC. |
| 401 | Supply Delivery & installation of hybrid combination call bell central system for 23 (Twenty Three) modules with individual indications and alarming system with manual reset for 23 (Twenty Three) different bell push inputs (push To on and auto reset installed at patint bed side supply and installation against seperate item above of this estamet) at the nurse station for callaing the nurses at the hospital. Make approved by EIC. |
| 402 | Supply Delivery & installation of hybrid combination call bell central system for 16 (Sixteen) modules with individual indications and alarming system with manual reset for 16 (Sixteen) different bell push inputs (push To on and auto reset installed at patint bed side supply and installation against seperate item above of this estamet) at the nurse station for callaing the nurses at the hospital. Make approved by EIC. |
| 403 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 63A, TPN & Earth Metal Industrial Plug socket & 63A Industrial top incl. S&F 63 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. |
| 404 | Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board (D13/20b) |
| 405 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ByISI-Medium GI pipe [G-1/2a] (PANEL Earthing) |
| 406 | Excavation of soil for installation of Earth Electrode and filling & ramming.For Soft Soil [G-1/1a] |
| 407 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G-2/4a] |
| 408 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages Solid GI Wire: No.8 SWG[G-2/5] |
| 409 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) [J-1/1] |
| 410 | S & F of 4 SWG GI (Hot Dip) wire on Parapet / Roof / Plinth / Surface of wall for lightning conductor as required (for Horizontal runs) with 40 mm long GI Staples spaced not exceeding 1300 mm apart incl. mending good all the damages to the building works [J-1/2] |
| 411 | S & F of 4 SWG GI (Hot Dip) wire on wall for the lightning conductor as required (for vertical run) with GI Staples (40 mm long) spaced not exceeding 1 Mtr. apart incl. mending good the damages to building works (excluding hire charges of scaffolding) [J-1/3] |
| 412 | Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:Length upto 0.5Mtr. [J-1/4a] |
| 413 | Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. [J-1/5] |
| 414 | Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. [J-1/6] |
| 415 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. [J-1/7] |
| 416 | Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. [J-2/13] |
| 417 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ByISI-Medium GI pipe [G-1:2a] (02no for Building EI work and 10 no for LC work) |
| 418 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [G-1/1a] |
| 419 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G-2/4a](0.5 mtr 10nos) |
| 420 | Supplying and fixing Sheet steel TPN Main Switches onangle iron frame on wall (60/63 A) Make:- L&T, ABB, C&S, HPL. (D1/1b) |
| 421 | Add 12% GST |
| 422 | Add LW CESS @ 1% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail