}

Procurement Of Gps Based Portable Multi-Parameter Measuring Equipment - Gps Based Portable Multi-Parameter Measuring Equipmentit Shall Be Potable Multi-Parameter Testing Equipment With Facility To Automatically Capture The Gps Location And Depth Of The M, okhla-Delhi

Delhi Jal Board-DJB has published Procurement Of Gps Based Portable Multi-Parameter Measuring Equipment - Gps Based Portable Multi-Parameter Measuring Equipmentit Shall Be Potable Multi-Parameter Testing Equipment With Facility To Automatically Capture The Gps Location And Depth Of The M. Submission Date for this Tender is 28-03-2022. Electrodes Tenders in okhla Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

31391192
Procurement Of Gps Based Portable Multi-Parameter Measuring Equipment - Gps Based Portable Multi-Parameter Measuring Equipmentit Shall Be Potable Multi-Parameter Testing Equipment With Facility To Automatically Capture The Gps Location And Depth Of The M
Open Tender
Indian
Delhi
okhla
28-03-2022

Tender Details

Procurement Of Gps Based Portable Multi-Parameter Measuring Equipment - Gps Based Portable Multi-Parameter Measuring Equipmentit Shall Be Potable Multi-Parameter Testing Equipment With Facility To Automatically Capture The Gps Location And Depth Of The Measuring 09 Parameters. The Multi-Parameter Will Be Water-Proof. All The Sensors Shall Be Housed In One Rugged, Shock Resistance And Chemical Resistance Housing. The Probes Can Be Changed In The Field And Will Be Made With Chemical Resistance Material And Easy To Maintain. There Shall Be Additional Protection To Ph Electrode So It Shall Not Break. There Shall Be Backlit Led Display To Enable Testing In The Dark. It Shall Have Auto Calibration Facility. The Instrument Shall Be Capable Of Capturing Data Instantaneously Even While On Move. The Data Can Be Transferred To Computer In Dedicated Software Supplied With The Help Of Usb Port. Other Than This The Multi-Parameter Shall Have Internal Data Memory Of 10, 000 Logs. The Will Be 30 Meter Cable To Enable Testing Up To 30 Meters With Depth And Location Capture.Parameterspecificationmeasuring Parameter Measures Total 09 Parameter Like Ph, Do, Temperature, Conductivity, Salinity, Tds, Temperature, Turbidity, Water Depth, Gpslcd 320 X 240 Liquid Crystal Display With Backlight ( Black And White ) Communication Usbdata Memory 10, 000Battery C Batteries X 4Water Resistance Of Display Unit Jis Protection Level 7 ( When Sensor Cable Is Fitted ) Battery Life Approx. 500 Measurementsstorage Temperature -10 To 60?Ambient Temperature5 To 45?Gps Technology 12 Channel Parallel12 Channel Parallel Data Hold Auto Hold Function Available To Freeze Datasoftware Separate Software Will Be Provided With Instrument For Pc Communication, Graph Tend.Measurement Temperature -5 To 55?Maximum Sensor Diameter Approx. 96 Mmprobe Length Approx. 340 Mmcable Length 30 Mtr.Turbidity Wiper Confirmturbidity Sensor Compliance Method Turbidity Sensor Conforms To Usepa Method 180.1Measurement Depth Max. 30 Mwater Resistance Of Sensor Probe Jis Protection Level 8Ph Sensormeasurement Principle Glass Electrode Methodph Range 0 To 14Resolution 0.01Phrepeatability ±0.05Phaccuracy ±0.1Phdissolved Oxygen ( Do ) Measurement Principlepolarography Methodrange 0 To 50.0 Mg / Lresolution 0.01 Mg / Lrepeatability ±0.1 Mg / Laccuracy 0 To 20 Mg / L: ±0.2 Mg / L 20 To 50 Mg / L: ±0.5 Mg / Lparameterspecificationconductivity ( Cond ) Measurement Principle 4 Ac Electrode Method Range 0 To 10 S / M ( 0 To 100 Ms / Cm ) Resolution 0.000 To 0.999 Ms / Cm: 0.001 Ms / Cm; 1.00 To 9.99 Ms / Cm: 0.01 Ms / Cm; 10.0 To 99.9 Ms / Cm: 0.1 Ms / Cm; 0.0 To 99.9 Ms / M: 0.1 Ms / M; 0.100 To 0.999 S / M: 0.001 S / M; 1.00 To 9.99 S / M : 0.01 S / Mrepeatability ±0.05% F.S.Accuracy *±1% F.S. ( Median Of Two-Point Calibrationsalinitymeasurement Principleconductivity Conversionrange 0 To 70 Ppt ( Permillage ) Resolution 0.1 Pptrepeatability ±1 Pptaccuracy ±3 Ppttotal Dissolved Solid ( Tds ) Measurement Principle Conductivity Conversion Range 0 To 100 G / Lresolution 0.1% F.Srepeatability ±2 G / Laccuracy ±5 G / Ltemperaturemeasurement Principlethermistor Methodrange -10 To 55?Resolution 0.01?Repeatability *±0.10? ( At Calibration Point ) Accuracy Jis Class B Platinum Thermometer Sensor ( ±0.3+0.005 | T | ) Turbidity ( Turb ) Measurement Principletungsten Lamp Source And 90°Scattering Methodrange 0 To 1000 Nturesolution 0 To 9.99 Ntu: 0.01 Ntu; 10 To 99.9 Ntu: 0.1 Ntu; 100 To 1000 Ntu: 1 Nturepeatability ±3% ( Reading ) Or ±0.1 Ntu Whichever Is Greateraccuracy 0 To 10 Ntu : ±0.5 Ntu: 10 To 1000 Ntu: 3% ( Reading ) Or ±1 Ntu Whichever Is Greaterwater Depthmeasurement Principlepressure Methodrange 0 To 30 Mresolution 0.05 Mrepeatability ± 1% Of F.Saccuracy ±0.3 M

Key Value

Document Fees
INR 500 /-
EMD
INR 34000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:-Procurement of GPS based Portable Multi-Parameter Measuring Equipment
Sl. No. Item Description
1Specification Specification for GPS based Portable Multi-Parameter measuring equipment It shall be Potable Multi-Parameter testing equipment with facility to automatically capture the GPS location and depth of the measuring 09 parameters. The multi-parameter will be water-proof. All the sensors shall be housed in one rugged, shock resistance and chemical resistance housing. The probes can be changed in the field and will be made with chemical resistance material and easy to maintain. There shall be additional protection to pH electrode so it shall not break. There shall be backlit LED display to enable testing in the dark. It shall have auto calibration facility. The instrument shall be capable of capturing data instantaneously even while on move. The data can be transferred to computer in dedicated software supplied with the help of USB port. Other than this the Multi-parameter shall have internal data memory of 10,000 logs. The will be 30 meter cable to enable testing up to 30 meters with depth and location capture. PARAMETERSPECIFICATION Measuring parameter Measures total 09 parameter like pH, DO, Temperature, conductivity, Salinity, TDS, Temperature, Turbidity, Water depth, GPS LCD 320 x 240 liquid crystal display with backlight (black and white) Communication USB Data Memory 10,000 Battery C batteries x 4 Water resistance of Display Unit JIS protection level 7 (when sensor cable is fitted) Battery Life Approx. 500 Measurements Storage temperature -10 to 60? Ambient temperature5 to 45? GPS Technology 12 Channel Parallel12 Channel Parallel Data Hold Auto HOLD function available to freeze Data Software Separate Software will be provided with instrument for PC communication, Graph tend. Measurement temperature -5 to 55? Maximum sensor diameter Approx. 96 mm Probe length Approx. 340 mm Cable length 30 mtr. Turbidity wiper Confirm Turbidity Sensor Compliance method Turbidity Sensor Conforms to USEPA method 180.1 Measurement depth Max. 30 m Water resistance of Sensor Probe JIS protection level 8 PH sensor Measurement principle Glass electrode method pH Range 0 to 14 Resolution 0.01pH Repeatability ±0.05pH Accuracy ±0.1pH Dissolved Oxygen (DO) Measurement principlePolarography method Range 0 to 50.0 mg/L Resolution 0.01 mg/L Repeatability ±0.1 mg/L Accuracy 0 to 20 mg/L: ±0.2 mg/L 20 to 50 mg/L: ±0.5 mg/L PARAMETERSPECIFICATION Conductivity (COND) Measurement principle 4 AC electrode method Range 0 to 10 S/m (0 to 100 mS/cm) Resolution 0.000 to 0.999 mS/cm: 0.001 mS/cm; 1.00 to 9.99 mS/cm: 0.01 mS/cm; 10.0 to 99.9 mS/cm: 0.1 mS/cm; 0.0 to 99.9 mS/m: 0.1 mS/m; 0.100 to 0.999 S/m: 0.001 S/m; 1.00 to 9.99 S/m : 0.01 S/m Repeatability ±0.05% F.S. Accuracy *±1% F.S. (Median of two-point calibration Salinity Measurement principleConductivity conversion Range 0 to 70 PPT (permillage) Resolution 0.1 PPT Repeatability ±1 PPT Accuracy ±3 PPT Total Dissolved Solid (TDS) Measurement principle Conductivity conversion Range 0 to 100 g/L Resolution 0.1% F.S Repeatability ±2 g/L Accuracy ±5 g/L Temperature Measurement principleThermistor method Range -10 to 55? Resolution 0.01? Repeatability *±0.10? (at calibration point) Accuracy JIS class B platinum thermometer sensor (±0.3+0.005 | t |) Turbidity (TURB) Measurement principleTungsten lamp source and 90°scattering method Range 0 to 1000 NTU Resolution 0 to 9.99 NTU: 0.01 NTU; 10 TO 99.9 NTU: 0.1 NTU; 100 TO 1000 NTU: 1 NTU Repeatability ±3% (Reading) or ±0.1 NTU whichever is greater Accuracy 0 TO 10 NTU : ±0.5 NTU: 10 to 1000 NTU: 3% (Reading) or ±1 NTU whichever is greater Water depth Measurement principlePressure method Range 0 to 30 m Resolution 0.05 m Repeatability ± 1% of F.S Accuracy ±0.3 m
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail