Medical College-MC has published Ht Box And Cabelling Work Ht Box And Cabelling Work , Ht Box & Cabling Work , Supply, Installation, Testing & Commissioning Of Ht Metering Cubical Panel As Approved By Discoms Fabricated Out Of 14 Swg Crca Sheet Steel In Two Compartment & Ms Angle Of . Submission Date for this Tender is 09-03-2022. Rivets Tenders in Udaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | HT Box & Cabling work |
2 | Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i)Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set (To be supplied by DISCOMs), (iii)TT Block, (iv) 6mm Bakelite sheet on all sides, (V) 3/6 core copper cable for interconnections etc. as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . |
3 | Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables. All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR . 3 core 185.0 Sq.mm |
4 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 11 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm |
5 | 11 KV Straight Through JointKit 3 core 120/150/185 Sq.mm |
6 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
7 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish: 20mm thick |
8 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering,saddles, making connection with GI/Cuthimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/work,refer Annexure "A" attached with this BSR . 8 SWG copper Wire |
9 | 8 SWG G.I. ( Hot Dipped) Wire |