Tn-Mm-1670 Supply Of Pressure Transmitters, Dp Transmitters, Level Transmitters, Flow Transmitters And Fuel Oil Transmitters For Sstps, Unit 1 To 6 At Sstps, Suratgarh , Supply Item , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range:(0-150 Mmwcl),Power Supply 10.5 To 45V Dc, Output: 4-20Ma Dc, , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: (0-1000 Mmwcl), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc, , Furnace Pr (Wide Range) Transmitter Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: {(-250) To 250 Mmwcl}, Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Furnace Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: {(-50) To 50 Mmwcl} Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: {(-100) To 0 Mmwcl}, Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: {(-350) To 0 Mmwcl}, Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: (0-12 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: (0-150 Mmwcl), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: (0-1000 Mmwcl), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Air, Working Range: (0-2000 Mmwcl), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [(-1900) To 1800 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc, , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [(-250) To 250 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam,Working Range: [(-250) To 300Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam,Working Range: [(-310) To 1840 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [(-800) To 1050 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [0 To 1050 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Fcs Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [0 To 20 Kg/Cm2], Power Supply 10.5 To 45V, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [0 To 20000 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [0 To 5000 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [0 To 1000 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Dp Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: [0 To 10000 Mmwcl], Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: {(-1) To 0 Kg/Cm2}, Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: {(-1) To 3 Kg/Cm2}, Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: {(-1) To 9 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: (0 To 10 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: (0 To 15 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: (0 To 25 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: (0 To 60 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Steam, Working Range: (0 To 300 Kg/Cm2), Power Supply 10.5 To 45 Dc, Output 4-20Ma Dc , Pr Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Fuel Oil, Working Range: (0 To 40 Kg/Cm2), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc, Flange Type , Guided Wave Level(Contact) Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Fuel Oil, Working Range: (0 To 4000 Mmwcl), Power Supply: 10.5 Vdc To 45 Vdc, Output: 4-20Ma Dc , Guided Wave (Contact) Level Transmitter 2-Wire Smart Type,Hart Enabled, Loop Powered, Working Medium:-Fuel Oil, Working Range: (0 To 6000 Mmwcl), Power Supply 10.5 To 45V Dc, Output: 4-20Ma Dc , Mass Flow Transmitter Smart Type,Hart Enabled, Loop Powered, Working Medium:-Fuel Oil, Working Range: (0-22 Tph), Power Supply 10.5 To 45V Dc, Output 4-20Ma Dc , Radar Type Integrated Level Transmitter For Measuring Raw Water Bay Level , Sub Total(From 1.01 To 1.34) , Total Packing & Forwarding Charges , Sub Total Of Suppy+P&F (Including Gst) , Total Freight Charges , Total Insurance Charges , Other Taxes/ Charges(If Any) , Total Supply Amount (1.37 To 1.40)