}

Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme, hazaribag-Jharkhand

Water Resources Department has published Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme. Submission Date for this Tender is 03-03-2022. Bolts Tenders in hazaribag Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31227361
Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme
Open Tender
NCB
Jharkhand
Hazaribag
03-03-2022

Tender Details

Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme Rate Through E - Quotations Are Invited For Material Category Annexed As ( I ) 20 H.P. Solar Pump, Vfd, Solar Panel Set And Ii ) 10 H.P. Dc Solar Pump, Solar Panel, Steel Structure Supplying, Installation And Commissioning For Lift Irrigation Scheme , For 20 Hp Spv Ac Surface Pump , Solar Module Mounting ( Galvanised Steel ) Surface Structure ( For 50 Kw ) Having Hot Deep Galvanised Ofzinc Thickness 80Micron And As Per Is4759 With C Channel $ Anti Theft With Nut Bolt Of Grade Ss304, Which Should Also Withstand High Wind Velocity Upto 150Km / Hr Or As Per Mnre. , 50Kwp Spv Module Of 330Wp Or Higher Rating, Which Must Have Specification As Per Is 14286 / Iec 61215 .The Module Must Have To Quilifyis / Iec 61730 Part I $ Ii ( Or Having Mechanical Load Test Of 5400Pa ) For Safety Purpose.Module To Module Wattage Mismatch In Spv Array Shall Be + / -3% And To Qualify Iec Ts 62804-:2015 For The Detection Of Potential Induced Degradation And Warranted For Output Wattage Not Less Than 90% In 10Yrs And 80% At The End Of 25Yrs As Per Mnre. , Spv Controller / Vfd Integrated With Gprs, Having Mppt , Protection Ip 65 Or Above As Per Mnre To Run 20Hp Ac Solar Pump. , Solar Cable 4 Mm2usedas Per Is 694 Or As Per Mnre. , Copper Cable 95 Mm2 Used As Per Is 694 Or As Per Mnre. , Arrangement Of Lightening Arrestor Excluding Earthing For 50Kw & 3 Nos. 20Hp Solar Pump , 20 H.P. A.C. Solar Pump Set Ofhaving Performance With Respect To Total Head, Maximum Current, Capacity, Voltage Range Etc As Per Mnre Guidelines. , Array Junction Box ( Ip 65 Or Above ) As Per Mnre For 50Kw Spv. , Miscllaneous Accessories For Installation Of 20H.P. Solar Pump , Supplying, Installation And Commissioning Charge Of Module And Structure For 50Kw. , Maintenance For Atleast 5 Years Or As Per Mnre Guidelines For 50Kw Spv Module & 3 Nos. 20Hp Ac Solar Pump With All Accessories , For 10 Hp Spv Dc Surface Pump Solar Module Mounting ( Galvanised Steel ) Surface Structure For 50 Kw Having Hot Deep Galvanised Ofzinc Thickness 80Micron And As Per Is4759 With C Channel $ Anti Theft With Nut Bolt Of Grade Ss304which Should Also Withstand High Wind Velocity Upto 150Km / Hr Or As Per Mnre. , 50 Kwp Spv Module 330Wp Or Higher Which Must Have Specification As Per Is 14286 / Iec 61215 .The Module Must Have To Quilifyis / Iec 61730 Part I $ Ii ( Or Having Mechanical Load Test Of 5400Pa ) For Safety Purpose.Module To Module Wattage Mismatch In Spv Array Shall Be + / -3% And To Qualify Iec Ts 62804-:2015 For The Detection Of Potential Induced Degradation And Warranted For Output Wattage Not Less Than 90% In 10Yrs And 80% At The End Of 25Yrs As Per Mnre. , Spv Controller / Vfd Integrated With Gprs, Having Mppt , Protection Ip 65 Or Above As Per Mnre To Run 10Hp Dc Solar Pump. , Solar Cable Of 4Mm2 Used As Per Is 694 Or As Per Mnre , Copper Cable 25Mm2 Used As Per Is 694 Or As Per Mnre. , Arrangement Of Lightening Arrestor Excluding Earthingas Per Mnre For 50Kw Spv $ 5 Nos 10Hp Dc Solar Pump. , 10 H.P. D.C. ( Pmsm / Bldc / Srm ) Solar Pump Set Ofhaving Performance With Respect To Total Head, Maximum Current, Capacity, Voltage Range Etc As Per Mnre Guidelines. , Array Junction Box ( Ip 65 Or Above ) As Per Mnre For 50 Kw Spv. , Miscllaneous Accessories For Installation Of 10 H.P. Solar Pump , Supplying, Installation And Commissioning Charge Of Module And Structure For 50Kw. , Maintenance For Atleast 5 Years Or As Per Mnre Guidelines For 50Kw Spv Module & 5 Nos. 10Hp Dc Solar Pumpwith All Accessories

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail