Construction Of Building For Kailashahar Pwd R B Division And Sub Division Office At Kailashahar, Unakoti District, Tripura Sh Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works Remaining Work. 3Rd C, kailashahar-Tripura

Public Works Department-PWD has published Construction Of Building For Kailashahar Pwd R B Division And Sub Division Office At Kailashahar, Unakoti District, Tripura Sh Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works Remaining Work. 3Rd C. Submission Date for this Tender is 09-03-2022. Building Work Tenders in kailashahar Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

31227137
Construction Of Building For Kailashahar Pwd R B Division And Sub Division Office At Kailashahar, Unakoti District, Tripura Sh Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works Remaining Work. 3Rd C
Open Tender
Indian
Tripura
kailashahar
09-03-2022

Tender Details

Construction Of Building For Kailashahar Pwd R B Division And Sub Division Office At Kailashahar, Unakoti District, Tripura Sh Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works Remaining Work. 3Rd Call Construction Of Building For Kailashahar Pwd R B Division And Sub Division Office At Kailashahar, Unakoti District, Tripura Sh Building Portion Including Internal Water Supply, Sanitary Installation, Sewage And Drainage Works Remaining Work. 3Rd Call

Key Value

Document Fees
INR 5000 /-
EMD
INR 282641.0 /-
Tender Value
INR 2.82 Crore /-

BOQ Items

Name of Work: Construction of building for Kailashahar PWD(R&B) Division and Sub-Division Office at Kailashahar, Unakoti District, Tripura/SH: Building portion including Internal water supply, Sanitary Installation, Sewage & Drainage works./ Remaining Work
Sl. No. Item Description
1SUB-HEAD : EARTH WORK
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. - All kinds of soil
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. - All kinds of soil
5Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
6Supplying chemical emulsion in sealed containers including delivery as specified.
7(i) Chlorpyriphos/Lindane emulsifiable concentrate of 20%
8Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion):
9(i) Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: - With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
10(iii) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: - With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
11SUB-HEAD : CEMENT CONCRETE WORK
12Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level.
13(i) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size)
14(ii) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)
15(iii) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
16Centering shuttering including struttings, propping etc. and removal of form work for:
17(i) Foundations, footings, bases for columns.
18Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50 kg of cement.
19Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
20SUB-HEAD : RCC WORK
21Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement. - All work upto plinth level.
22(i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
23Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
24(i) Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
25Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-
26(i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
27Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
28Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
29(i) Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
30Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits
31(i) 50 mm thick
32Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).
33Centering shuttering including struttings, propping etc. and removal of form work for:
34(i) Foundations, footings, bases for columns etc. for mass concrete with timber plank
35(ii) Walls (any thickness ) including attached pilasters, butresses, plinth and string courses etc. using shuttering ply
36(iii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
37(iv) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
38(v) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
39(vi) Stairs (excluding landings) except spiral-staircases with wooden plank
40(vii) Edges of slabs and breaks in floors and walls under 20 cm. wide
41SUB-HEAD : BRICK WORK
42First class brick work in foundation and plinth including cost of all materials as required complete.
43(i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
44(ii) In cement mortar 1:6 ( 1 cement : 6 fine sand ).
45First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete.
46(i) In cement mortar 1:6 ( 1 cement : 6 fine sand ).
47Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-
48(i) In cement mortar 1:4 ( 1 cement : 4 fine sand).
49Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-
50(i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
51SUB-HEAD : CLADDING WORK
52Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels:-
53(i) 18 mm thick Granite of any colour and shade duly approved:- - Area of slab over 0.50 sqm.
54SUB-HEAD : WOOD WORK
55Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :
56(i) Karai wood
57Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters.
58(i) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
59Providing 50 × 50 × 50 mm Gamair wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement: 3 fine sand) and making good the walls etc.
60Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.
61(i) Fixed to openings /wooden frames with rawl plugs screws etc.
62Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size)
63Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
64(i) 300 x 16 mm
65Providing and fixing ISI marked aluminium tower bolts anodised (anodised coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete as per clauses of Chapter - 9 of CPWD specification.
66(i) 300 x 10 mm
67(ii) 250 x 10 mm
68Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
69(i) 125 mm
70(ii) 100 mm
71Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
72(i) Single rubber stopper
73Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws.
74Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solventadhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter).
75Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.
76SUB-HEAD : STEEL WORK
77Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys& with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings,including applying a priming coat of approved steel primer etc. complete as required.
78Providing and fixingfan clamp type-Iof 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete.
79Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-
80(i) M.S. tube
81Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-
82(i) In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete.
83Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design.
84SUB-HEAD : ALUMINIUM WORK
85Providingandfixingaluminiumworkfordoors,windows,ventilators and partitions withextrudedbuiltupstandardtubularsections/ appropriateZsectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawingandthedirectionofEngineer­in­charge.(Glazingand paneling and dash fasteners to be paid for separately) :-
86(i) For fixed portion of approved quality:- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15).
87(ii) For shutters of doors, windows & ventilatorsincluding providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15).
88Providing and fixing glazing of approved quality in aluminium doors,windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-
89(i) With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm )
90(ii) With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm )
91Providing and fixing stainless steel ( SS 304 grade ) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:-
92(i) 255 x 19 mm
93Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality completeas per direction of Engineer-in-charge:-
94(i) Anodised aluminium of grade AC 15 ).
95SUB-HEAD : FLOORING AND SKIRTING WORK
96Providing and fixingMarble stone in floors over 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishingcomplete.
97(i) 18 mm thick Marble stone - Raj Nagar plain marble
98Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete.
99(i) A. Mat Finish Tiles - Ceramic Tiles 1st quality 300 x 300mm in all shades and designs
100(ii) B. Anti-Skid Tiles - Ceramic Tiles 1st quality 300 x 300mm in all shades and designs
101Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shadesof any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.
102Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.
103(i) Double charged Stainfree vitrified tiles - Size of tile 60x60 cm
104Providing and fixing Kota stone in floors over 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishingcomplete.
105(i) Kota stone slab 25mm thick
106Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. complete.
107(i) 40 mm thick with 20 mm stone aggregate
108Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats) over and including water thinnable priming coat with cement primer.
109SUB-HEAD : ROOFING AND CEILING WORK
110ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes (working pressure 4 kg / cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion:
111(i) Single socketed pipe - 110 mm OD
112Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion:
113(i) Coupler - 110mm
114(ii) Single equal tee without door - 110 x 110 x 110 mm
115(iii) Single equal tee with door - 110 x 110 x 110 mm
116(iv) Bend 87.5 - 110mm
117(v) Plain shoe - 110 mm
118Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVCrainwater pipesbymeansof50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work andfixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.
119(i) 110mm
120Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.
121(i) 100mm
122SUB-HEAD : FINISHING WORK
12312 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
124(i) In cement mortar 1 : 4 (1 cement : 4 fine sand)
125(ii) In cement mortar 1 : 6 (1 cement : 6 fine sand)
12615 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
127(i) In cement mortar 1 : 6 (1 cement : 6 fine sand)
1286 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.
129(i) In cement mortar 1 : 3 ( 1 cement : 3 fine sand )
130Neat cement punning.
131Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats) over and including water thinnable priming coat with cement primer.
132Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
133Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
134With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ).
135With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
136Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work
137SUB-HEAD:WATER PROOFING WORK
138Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :
139(i) Cement concrete 1:2:4 ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ).
140(ii) Cement mortar 1:4 (1 cement : 4 fine sand )
141Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like as required as per direction of the Engineer-in-charge, consisting of : (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) 2nd course of 20 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).
142SUB-HEAD : SANITARY WORKS
143Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushingcisternwithmanuallycontrolleddevice(handlelever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
144(i) White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests.
145Providingandfixingwhitevitreouschinapedestaltypewatercloset (Europeantype W.C.pan)withseatandlid,10litrelowlevelwhite P.V.C.flushing cistern withmanually controlled device (handlelever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
146(i) W.C. pan with ISI marked white solid plastic seat and lid
147Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:
148(i) Flat back wash basin of size 550x400mm.
149Providing and fixing kitchen sink including making all connections excluding cost of fittings.:
150(i) White glazed fire clay sink of size 600x450x250mm.
151Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
152(i) Semi rigid pipe - 32 mm dia
153(ii) Flexible pipe - 32 mm dia
154Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
155Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
156Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms
157Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms
158Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms.
159ProvidingandfixingonwallfaceunplasticisedRigidPVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion:
160(i) Single socketed pipe - 110 mm OD
161Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVCrainwater, soil, waste & vent pipesbymeansof50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work andfixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.
162(i) 110mm
163Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion:
164(i) Coupler - 110 mm
165(ii) Single equal tee without door - 110x110x110mm
166(iii) Single equal tee with door - 110x110x110mm
167(iv) Doubleequal junction of required degreewithout door - 110x110x110 x110 mm
168(v) Doubleequal junction of required degreewith door - 110x110x110 x110 mm
169(vi) Bend 87.5° - 110mm
170(vii) Plain shoe - 110mm
171(viii) Terminal guard - 110 mm
172SUB-HEAD : WATER SUPPLY
173ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVCsolventcement and testing of jointscomplete as per direction of Engineer in Charge. - Internal work -Exposed on wall
174(i) 15 mm nominal outer dia .Pipes.
175(ii) 20 mm nominal outer dia. Pipes.
176(iiii) 25 mm nominal outer dia .Pipes.
177ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement ,trenching,refilling & testingof joints complete as per direction of Engineer in Charge. External Work
178(i) 20 mm nominal outer dia .Pipes.
179(ii) 25 mm nominal outer dia. Pipes.
180(iii) 40 mm nominal outer dia .Pipes.
181Providing and fixing brass bib cock of approved quality :
182(i) 15 mm nominal bore
183Providing and fixing brass stop cock of approved quality :
184(i) 15 mm dia nominal bore
185Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
186(i) 25 mm nominal bore
187(ii)40 mm nominal bore
188Providing and fixing gun metal non-return valve of approved quality (screwed end):
189(i) 25 mm nominal bore - Vertical
190(ii) 40 mm nominal bore - Vertical
191Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
192Constructing masonryChamber 30x30x50 cm, insidewith 75 class designation brick work incement mortar1:5 (1 cement :5 fine sand) forstopcock, withC.I.surface box100x100x75mm (inside)with hingedcover fixedincement concreteslab1:2:4mix (1 cement:2 coarsesand:4gradedstoneaggregate20mmnominalsize) necessary excavation foundationconcrete 1:5:10 ( 1cement :5fine sand:10gradedstoneaggregate40mmnominalsize)andinside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finishedwithafloatingcoatofneatcementcompleteasper standard design :
193(i) With Second Class bricks
194SUB HEAD : SEWAGE AND DRAINAGE WORKS
195Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :
196(i) 150 mm diameter
197Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design:
198(i) 150 mm diameter S.W, pipe
199Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
200Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
201(i) Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
202Extra for depth beyond 450 mm of brick masonry chamber for underground C.I. inspection chamber with same specification as mentioned in item no 20.330 complete as per standard design :
203(i) For 500x700 mm size
204SUB HEAD : MISCELLANEOUS WORKS
20560mm thick factory made cement concrete interlocking paver block of M-30 grade. Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making mchine with strong vibratory compaction of approved size, design and shape, laid in required colour and pattern over and incloding 50mm thick compacted bed of sand, fillin the joints with fine sand etc. all complete as per specification and approval/direction of the engineer-in-charge.
206ProvidingcorrugatedG.S.sheetroofingincludingvertical/curved surface fixedwithpolymercoatedJorLhooks,bolts andnuts8mm diameterwithbitumenandG.I.limpetwashersorwithG.I.limpet washersfilledwithwhiteleadandincludingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheets complete(uptoanypitchinhorizontal/verticalorcurvedsurfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(i) 0.63mm thick with zinc coating not less than 275gm/m2
207Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately). (i) Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick conforming to IS:14587