Webel Technology Limited-WTL has published Selection Of System Integrator For Capacity Enhancement Of West Bengal State Data Centre Wb Sdc And Setting Up Its Dr Site At Remote Location. Submission Date for this Tender is 31-03-2022. Building Work Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Mar-2022 | CORRIGENDUM2 | BOQ | 17-03-2022 |
2 | 08-Mar-2022 | CORRIGENDUM1 | Technical Bid | 17-03-2022 |
3 | 09-Mar-2022 | CORRIGENDUM 3 | Technical Bid | 17-03-2022 |
4 | 16-Mar-2022 | CORRIGENDUM 4 | Date | 31-03-2022 |
Sl. No. | Item Description |
1 | HPE Storage DC (Primera 650) - existing 450TB usable space upgrade to 650TB USABLE space (i.e additional 100TB SSD and additional 100TB SAS) |
2 | Netapp Storage DC (AFF-A700) - existing 220TB usable space upgrade to 430TB USABLE space (i.e additional 210TB SSD) |
3 | Blade server with 2 x Intel 6238R 2.2GHz/165W 28C/38.5MB, 1536GB DDR4 2933MHz mem, 2x960GB 12G SAS 10K RPM SFF HDD, 12G SAS RAID controller with Drive bays OR Equivalent for DC as per detail specification |
4 | Blade Chassis with converged network connectivity for 4x32GB FC, 4x10G FCOE/Equivalent and 2x40G connectivity, Redundant 2500W Platinum AC Hot Plug Power Supply along with necessary QSFP40G Transceivers / FI Extender as requiredfor DC as per detail specification OR Equivalent |
5 | Rack Server with 2 xIntel latest generation Xeon® Gold Ice Lake Processors with minimum 2.0 Ghz & 32Coreper socket and 48 MB Cache., 768GB DDR4 2933MHz mem, 4x1.2TB 12G SAS 10K RPM SFF HDD or equivalent for DC. |
6 | Red Hat Cloud Infrastructure, Premium (2-sockets)with support for 3 years required for DC |
7 | High Availability for Unlimited Guests with support for 3 years for DC. |
8 | DCO, Capacity & ITO software license - 20 Nos. along with Data Center Operation Cooling Optimize Temperature Sensor - 6 Nos. And Cooling Optimize Gateway - 1 No 24 Port DCIM Switch- 2no"s as per site requirement for DC. |
9 | EDB Postgres Enterprise Unicore per year license - Production DB Support Plan for 3 years for DC |
10 | EDB Postgres Enterprise Unicore per year license - Replica DB Support Plan for 3 years for DC |
11 | EMS Software per device for 3 years (as per technical spec.). Underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
12 | Red Hat Enterprise Linux for Virtual Datacenters, Standard with support for 3 years for DC |
13 | Red hat Openshift Container Platform (Bare Metal Node) with run time, Premium, 1-2 Nodes upto 64 Cores for 3 years for DC |
14 | Version Control Software with Functional test automation - 10 Concurrent User, Load runner professional foundation - qty 1 (500 virtual users) and Application Life Cycle Manager - 10 concurrent user license with support for 2 years. Underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
15 | MS SQL Standard Latest version for DC |
16 | My SQL enterprise version (3 years) for DC |
17 | Lotus Domino/ MS Exchange/ EquivalentEmail software with 250 user mail box with all security features. The required IT infra for proposed MS Exchange solution [Compute & Storage] will be provided from the existing cloud infrastructure of WBSDC. The successful Bidder has to provide the MS Exchange with necessary security software licenses required for installation and smooth running of mailing solution for DC |
18 | DDOS First 2 Years - BOQ - DDoS Protector appliance with SME Dual Power Supply for DC |
19 | 10Gbps Pluggable Optics (XFP) Multimode SR for DDOS for DC |
20 | Deployment of DDoS Protector in basic configuration at the customer site, including configuration, testing and tuning for DC |
21 | DDoS Management VA2 Virtual Appliance for management of 2 DDoS Protector physical devices for 2Y for DC |
22 | SOAR (Security Orchestration Automation Response) - Simplify Platform Base Package Premium. Includes: 2 years License for Platform, 3 analyst seats, 5 Advanced Reporting Users, 24x7 Premium support for 2 Years incuding implementation & training For 24X7 support for SOAR should include minimum 2 nos L2 level & 1 no L3 level Onsite Resources. Underlying Hardware Infra required including VMware, Microsoft licenses etc. will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
23 | Deep Security Software - Deep Security - Enterprise - per Server (VM) for DC |
24 | DDAN-Deep Discovery Analyzer for DC |
25 | VTL SYSTEM,DD4200,CTL,NFS,CIFS - CAPACITY UPGRADE to 75TB for DC |
26 | Integration of VTL with Commvault Tape Library for DC |
27 | UPS 80 KVAwith 30 mins battery backup for uninterrupted power supply to active tiles with necessary electrical cabling including ATS for switching between two power sources for DC |
28 | LTO 7 Tapes for Data Backup for DC |
29 | Rack Containment Zone Net Work and Server Racks- Supply, Installation, Testing & Commissioning of 42U Server Cabinet with Extruded Aluminium Profile based frame with top panel; having Static load bearing capacity of 1300 Kg as per Tender specifications. . Dimensions: 2100mm x 750mm / 800mm x 1200mm all complete as requiured and as per detailed specifications. Racks, PDUs, containment should be from same OEM for DC |
30 | Active tiles for 2nd,3rd & 4th containment for DC |
31 | Perforated tiles for 3rd & 4th containment for DC |
32 | Supply, Installation, Integration with existing infra, Testing & Commissioning of 42U Server Cabinet Extruded Aluminium Profile frame with top panel;having static load bearing capacity of 1300 Kg as per Tender specifications. . Dimensions: 2200mm x 800mm x 1200mm all complete as required and as per detailed specifications. Racks, PDUs, containment should be from same OEM for DC |
33 | Supply, Installation, testing and intregation with existing infra, Commissioning & Intregation of Single Phase 32 A , 7 kW Zero U Vertical Rack IPDU with combination of C 13 and C 19 sockets of total 36 Nos. VDE Certified & ROHS Compliant as per technical specifications for DC |
34 | Supply, Installation, Testing andintregation with existing infra, Commissioning of Universal Cold Aisle Containment including wall beams, end-of-row frames, dual sliding doors with provision for CCTV Cameras , FAS detectors (Width - 1200mm), necessary passive cabling, all complete as required and as per detailed specifications.( for existing and new containment) for DC |
35 | Supply, Installation, Testing andintregation with existing infra, Commissioning of CCTV camera near BMS corridor, 4kl UG Fuel tank, First floor entry, Landing room for DC |
36 | Dismantling of existing false celing and existing electrical wiring, DBs, Fire fighting system and Modification of AC duct and opening of Exit Door at DR Site |
37 | Mineral Fiber Ceiling for DR False Ceiling of Mineral fiber board at appropriateheight should be installed concealing any cabling tray and electrical lighting wiring in all areas except server/network room. The False Ceiling tile should be Dust free type and of Noncombustible material. 1200 mmcross tee at every 600 mm c/c and 600mmcross tee at every 1200mm c/c max and wall angle all around the wall to form a grid of 600 mm x 600 mm and suspending the grid using 2mm GI rod and 6 mm raw plug at every 1200 mm intervals at the main tee and laying the Ceiling tiles of size 595 mm x 595 mm x 15 mm over the formed grid having fire rating of 60 minutes as per BS 476/23 of 1987, Noise reduction Coefficient (NRC) of 0.50-0.60, to resist temperature and humidity conditions up to 40degree (104deg. F) and humidity of 99% RH should be installed. All overhead cable trays will be secured to a rigid frame that carries the load either to the roof structure or to the floor slab. |
38 | MetalCeiling for Server Room for DR False Ceiling of Metalboard at appropriateheight should be installed concealing any cabling tray and electrical lighting wiring in all areas except server/network room. The False Ceiling tile should be Dust free type and of Noncombustible material. 1200 mmcross tee at every 600 mm c/c and 600mmcross tee at every 1200mm c/c max and wall angle all around the wall to form a grid of 600 mm x 600 mm and suspending the grid using 2mm GI rod and 6 mm raw plug at every 1200 mm intervals at the main tee and laying the Ceiling tiles of size 595 mm x 595 mm x 15 mm over the formed grid having fire rating of 60 minutes as per BS 476/23 of 1987, Noise reduction Coefficient (NRC) of 0.50-0.60, to resist temperature and humidity conditions up to 40degree (104deg. F) and humidity of 99% RH should be installed. All overhead cable trays will be secured to a rigid frame that carries the load either to the roof structure or to the floor slab. |
39 | Raised Floor for DR- Supply & Installation of stepped raised floor .The floor panels shall be of size 600mm x 600mm fabricated entirely from non-combustible component which shall be 100% interchangeable and shall consist of flat steel top sheet, resistance welded to steel bottom section finished with anti corrosive and conductive paint. Pedestal assembling: Consisting of 100x100x2 mm thick galvanized MS base plate die-pressed fully welded to 1.6mm thick galvanized MS pipe to engage the Pedestal head assembly. The Pedestal head shall be 90x90mm, 4mm thk assembly consisting of an embossed steel plate having 4 holes with 6mm thk taping for fastening of stringer and locating of Tile. Care to be taken to achieve the zero levelling. |
40 | Double Cup Tile Puller for DR |
41 | Ramp for DR: Its sub floor elements must be sufficient to support fully loaded heavy equipment weighing at least 1600 kilograms. Ramp will be having lines with non-skid type mats on lining. The angle of inclination for ramp should not be more than 10 degree. |
42 | Steps for DR: Providing steps at the location shown in layout to match raised floor level to true floor level. The steps will be having lines with non-skid type mats on liningThe height of single step should not be more than 250 mm and width should not be less than 250 mm. |
43 | Tharmal insulation with 19 mm Nitrel rubber for DR |
44 | Providing and Applying approved Emulsion Low VOC paint in three or more coats of approved brand and shade to internal sufaces (walls / partitions/ ceiling or any other location as directed),to give an even shade to the approval of the engineer, including Putty & horoughly brushing the surface free from foreign matter, sand papering smooth, filling in all holes and cracks , applying lambi / palti and rubbing down the surface, lambi/palti sandwitched with two coats of approved primer, rate to include all tools, labour, scaffolding, primer as required completed as directed by the engineer for DR site |
45 | Fire Rated Paint with putty work for Server Room and Electrical Room at DR site |
46 | Fire Rated Partition for DR : Providing and fixing in position full height partition wall of 100 mm thick fire line gyp-board partition using 12.5 mm thick double fire line gypboard on both sides with GI steel metal vertical stud frame of size 50 mm fixed in the floor and ceiling channels of 50 mm wide to provide a strong partition. Glass wool insulation inside shall be provided as required. Fixing is by self-tapping screw with vertical studs being at 610 mm intervals. The same should be inclusive of making cut-outs for switch board, sockets, grill etc. It shall also include preparing the surface smoothly and all as per manufacture’s specification etc. finally finishing with one coat of approved brand of fire resistant coating. ( Server Room and Electrical Room ) |
47 | Non Fire Rated Partition for DR : Providing and fixing in position full height partition wall of 100 mm thickgyp-board partition using 12.5 mm thick double fire line gypboard on both sides with GI steel metal vertical stud frame of size 50 mm fixed in the floor and ceiling channels of 50 mm wide to provide a strong partition. Glass wool insulation inside shall be provided as required. Fixing is by self-tapping screw with vertical studs being at 610 mm intervals. The same should be inclusive of making cut-outs for switch board, sockets, grill etc. It shall also include preparing the surface smoothly and all as per manufacture’s specification etc. finally finishing with one coat of approved brand of fire resistant coating. |
48 | Fire rated door 2400 x 1500 double leaf in equal door for DR |
49 | Panic bar for fire exit door for DR |
50 | Fire rated door 2400 x 1000 single leaf for DR |
51 | Main Flash Door at Data Centre Entrance double leaf 1500 x 2400 for DR |
52 | BMS and Manager Room Flash Door single leaf 1000 x 2400 mm for DR |
53 | Liner work station for DR |
54 | Hydrolic lo back chair for DR |
55 | Cleanning & house keeping till hand over the project including debrise cleanning and out from site for DR. |
56 | Sinages as required considering all rooms, Danger plat, Push, Pull, Fire exit, Emergency exit for DR. |
57 | Drawing & Design cost ofDR site |
58 | Strutural Steel with Stair case for DR |
59 | Main Power Distribution Panel for DR : Supply Installation testing commissioning for Main Data Centre Panel. making of CRCA powder coated sheet, Having Incommer 200 A 4 pole MCCB with 36 KA. Out Going : 100 A 4 pole MCCB 3 nos, 63 A 4 pole MCCB 4 Nos, 32 A 4 pole MCB 6 nos, with multifunction meter with communication port ( RS 485) & R,Y, B, ON, OFF, Trip Indication LED lamps & 500 A rated Aluminium bus bar. |
60 | UPS Output Panel for DR : Incomer 2 Nos 100A 4 Pole MCCB with Metering ( MFM with RS 485 Port , Indication lamp and control MCBs ) Outgoing 32A DP 18 Nos |
61 | Lighting DBs, BMS DBs and Raw Power DBs for DR |
62 | 4 Run X 25 sq.mm. copper flexible cable for 80 KVA UPS Input and Output cable for DR |
63 | 4 Core 240 sq.mm. AL. Armured cable Incomer Supply for DR |
64 | 4 Run X 10 sq.mm. copper flexible cable for Lighting DB, Power DB , BMS DBs and PAC for DR |
65 | 50 sq.mm. copper flexible cable for earthing for DR |
66 | 3 CoreX 4 sq.mm. copper flexible cable for server rack for DR |
67 | Supply laying and commissioning of power points by 25 mm PVC conduit and 2.5 sqmm copper wire for power points and 1.5 sq.mm copper wire for lights points includingmodular switch sockets & all accessories for DR |
68 | Supply fixing and commissioning of power points for server racks including 32 A 3 pin industrial socket for DR |
69 | Supply Installation testing commissionong of chemical earthing with 17.5 sq.mm. copper bonded pipe for electrod, chemical compund as per ISI, Chamber High duty Polycarbonet cover etc for DR |
70 | Supply and fixing of 25 x 6 mm G.I Strip for DR |
71 | Earh Bus bar box with copper strip for DR |
72 | 10 sqmm single core cable for DGs earthing, UPS earthing and server Rack earthing for DR |
73 | Light Point wiring with 3 x 1.5 sqmm copper flexible wire and PVC conduit with modular switch & accessories for DR |
74 | Light fixture 36W 2ft x 2 Ft LED tupe for DR |
75 | Occupency Sensor for DR |
76 | Cable tray and raceway for DR: |
77 | 300 x 50 mm Ladder G.I cable tray with support arrangement for DR |
78 | 200 x 50 mm G.I perforated cable tray with support arrangement ( Power ) for DR |
79 | 200 x 50 mm G.I perforated cable tray with support arrangement ( Data) for DR |
80 | MS structural Steel for cable tray support and Panel Base Frame for DR |
81 | Supply & Laying of Anti static rubber mate 1.1 kv tested for electrical room as per ISI for DR |
82 | Shock Treatment chart for DR |
83 | First Aid Box for DR |
84 | Cost for devloping of all GFC & As built drawings as per recomendated size encluding design for DR |
85 | UPS 60 KVA (3x20 KVA) ModularUPS with 30 mins battery backup in single cabinet and all accessories for running as hot standby.Each UPS should expandable upto 4x20 kva moduler UPS in future for DR |
86 | Precision AC for DR Site Server Room as per detailed spec |
87 | G I hard drawn drain piping for DR |
88 | Supply, installation, testing & commissioning of GI class ‘B’ cut to required lengths and installed with all screwed joints, and providing and fixing in position with the necessary elbows, tees and reducers as per specifications. It shall be insulated with 9 mm thk nitrile rubber insulation. Humidifier Piping (assumption of 40 RMT/unit) 25mm dia all complete as required for DR |
89 | Supply, Lifting, shifting, & Installation ofMS Stands for indoor PAC units with rubber pads. The frame shall be painted with one coat of metal primertwo coats rust proof Epoxy Paint. The stand shall be Height adjustable type ± 25mm for Server Room stands all complete as required for DR |
90 | REFRIGERANT PIPING: Hard copper piping (7/8" Liquid + 1 1/8" Gas) along with closed cell elastomeric nitrile rubber insulation. Refrigerant pipe cost shall incude required neccessary supporting arrangement of hanging , wall fixed type. cost of wall chasing/ breaking and finish, etc all complete as required for DR |
91 | Refrigerant gas R410A all complete for DR |
92 | Refrigerant Oil all complete as required for DR |
93 | Supply, Laying, installation, Testing & Commissioning of Interconnection cable(3C X2.5 SQ MM, Armoured Cable) between Indoor & Outdoor unitsall complete.for DR |
94 | Seq CAT6 cable for multiple Indoor units all complete for DR |
95 | Supply & Installation of MS Stands for outdoor PAC condenser units with rubber pads. The frame shall be painted with one coat of metal primer and two coats rust proof Epoxy Paint all complete for DR |
96 | Providing and Fixing of Fire Sealant to close the cut-outs of Cables, refrigerant pipes and tray all complete as required for DR |
97 | Copper piping with electrical wirings for the above |
98 | IT Hardware Requirement at DR Site: Blade Server AC2 Chassis with fans (As per details specification shared seperately |
99 | Blade With 02 CPU, 1TB Memory, 2*960GB SSD for DR |
100 | SAN Switch : 16G FC switch, w/ 48 active ports + 16G SW SFPs for DR |
101 | Certificate Server/Rack Server for DR |
102 | Desktop Computer set for DR |
103 | L3 Switch 48 port for DR |
104 | L2 Switch for DR |
105 | Router one for DC and another for DR |
106 | Red Hat Cloud Infrastructure, Premium (2-sockets with guest OS) open Stack with Smart Management for DR, with VM replication feature between DC and DR |
107 | High Availability for Unlimited Guests for DR |
108 | VMware vCloud Suite Subscription- per CPU per year Commitment Plan - 60 month Prepaid + Vcentre 1 Nos for DR |
109 | EMS Software per device/VM for 5 years. Underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DR |
110 | Deep Security - Enterprise - per Server (VM) for 5 years for DR |
111 | Redhat Enterprise Linux Standard for virtual Datacentres with 1 Yr Standard Subscription for 5 years for DR site |
112 | HPE SAN Storage with 650 TB NL SAS usable space + 50 TB SSD usable space at DR for replication with existing DC HPE Primera 650 storage usable space |
113 | NetApp SAN Storage with 370 TB NL SAS usable space + 100 TB SSD usable space at DR for replication with existing DC Netapp Storage AFF-A700 |
114 | Enterprise Firewall as per specification mentioned/Equivalent for DR |
115 | 24 Port (all) PoE+(190W) switch with 2 SFP uplink ports for CCTV for DR |
116 | 10M HDMI CABLE.for DR |
117 | Performance Lite 2 MP IP Eyeball Camera Fixed lens. for DR |
118 | CAT 6 Cable for DR |
119 | Performance Lite 2 MP IP Bullet Camera Fixed lens. for DR |
120 | H265 4K 32CH NVR NO POE. for DR |
121 | Conduit 25 mmm PVC for DR |
122 | 49" Colour Monitor Industrial duty for DR |
123 | 9 U Network Rack (BMS) for DR |
124 | 2 door access Controller for DR |
125 | Supply of SMPS for Door Controller. for DR |
126 | Supply & Installation of Door controller Enclosour.for DR |
127 | Biometric Reader for DR |
128 | Card Reader for DR |
129 | Supply of "L" and "U" Bracket.for DR |
130 | Double Door EM Lock 600 lbs with LED for DR |
131 | Z bracket for 600lbs EM Lock. for DR |
132 | 600lbs electromagnetic lock unmonitored type 12V LED Lamp Only for Singleleafe door. for DR |
133 | MAGNETIC CONTACT 2 WIRE. for DR |
134 | Supply of ACS Workstation Intel® Quad Core, 2.8GHz or higher, 8 GB RAM, 100 GB free disk space, Dual Ethernet 10/100MBs, Software Requirements: * Microsoft Windows 10 (Enterprise) 64-bits * Microsoft .NET Framework v4.0 for DR |
135 | Exit Button 3 inches X 1 inch. for DR |
136 | Smart Access Card for DR |
137 | Access Control software for DR |
138 | Supply Installation Testing & Commissioning of addressable Optical Smoke Detector, Smoke Detection by : Photo-electric light scattering. for DR |
139 | Supply Installation Testing & Commissioning of addressable Heat Detector, Detection Technology : Thermistor / ROR for DR |
140 | Supply Installation Testing & Commissioning of Addressable Manualcall point with built in isolator and DIL switch for Address Setting for DR |
141 | Supply Installation Testing & Commissioning of The Loop Powered 100 dB Sounder Base with Beacon for DR |
142 | Supply Installation Testing & Commissioning ofAddressable Control Module for DR |
143 | Supply Installation Testing & Commissioning ofAddressable Monitor Module for DR |
144 | Supply Installation Testing & Commissioning ofAddressable Isolator module for DR |
145 | Supply Installation Testing & Commissioning of 2 Loop Fire Alarm Panel with 126 Addresses per Loop, Battery and accessories as per requirement. Battery Back-up for DR |
146 | 2 core x 1 sqmm Copper Flexible FRLS Cable for DR |
147 | 20 mm PVC Conduit for DR |
148 | ABC Type Fire Extingusher 5 Kg for DR |
149 | SITC of short wavelength laser based ultra high sensitive aspiration smoke detector as per detailed spec for DR |
150 | SITC of Power Supply units - Power supply unit with 110/230VAC input and 18 to 29VDC output. The power supply unit has the following indications: OK - Green LED and Fault - Yellow LED Power supply unit should have capacity to operate on battery backup in case of AC mains failure & should have built in charging circuit for batterys. for DR |
151 | SITC of Trunk Adaptor, Capillary Tube Connector, Capillary Tube, Capillary Sampling Point, Sampling point label red (complete set) for air sampling in room voids for area having false ceilings.for DR |
152 | SITC of Sampling Pipe having Smooth bore PVC Pipe 25mm Outer Dia & 19 to 21mm Inner Dia with all required accessories for DR. |
153 | Supply, Installation,Testing and Commissioning of 2 ZONE Water Leak Detection Panel (for server Room and Electrical Room) for DR |
154 | Water Leak detection Cable Sensor – 25 mtrs for DR |
155 | Electronic Hooter for DR |
156 | SITC of 2 x 1.0 sq mm screened copper flexible cablefor DR |
157 | SITC of Main Rodent Controller suitable to connect 24 Satelites @ 300sft at room area and 150 at ceiling and floor area.Server Room for DR |
158 | SITC of Satellite Stations / Transducers covering for DR |
159 | Cable and Conduits for DR |
160 | 2 core 1 sq.mm Cu. Flexible Shielded cable @ 275 meter each coil for DR |
161 | 20 mm PVC Conduit for DR |
162 | Console for DR |
163 | Stand Bracketsfor DR |
164 | 120 ltrs Tank and valve assembly with solenoid actuator, straps Empty (fill 60 - 100 Kgs.) for DR |
165 | Fire Suppression Fluid Novec1230, OEM Factory Fill per KG for DR |
166 | Cylender Accessoriesfor DR |
167 | Cylinder strap for DR |
168 | Pneumatic Actuator Shipping assembly for DR |
169 | Local Manual actuator for DR |
170 | Flexible discharge Hose -49 mm / SWIVEL ADAPTOR for DR |
171 | Flexible Actuation Hose / Pilot hose for DR |
172 | Nozzles, Brass drilled -360/180 deg throw selection for DR |
173 | LED type display sign board flashing with inbuilt Sounder “EVACUATE GAS RELEASED” & “DO NOT ENTER” for DR |
174 | 49 mm MANIFOLD CHECK VALVE for DR |
175 | PRESSURE SWITCH - DPST for DR |
176 | MANUAL RELELASE SWITCHfor DR |
177 | ABORT SWITCHfor DR |
178 | M.S. Seamless pipes as per ASTM A 106 Gr. B, schedule 40 with necessary Fittings & Hangers.for DR |
179 | 2 WAY MANIFOLD for DR |
180 | MS Channel support for DR |
181 | Gass Release Panel for DR |
182 | Cross Zoning Detector for DR |
183 | Hooter with strobe 100 DB for DR |
184 | BUILDING MANAGEMENT SYSTEM APPLICATION for DR |
185 | 6KVA online UPS with 20 minutes backup for DR |
186 | Structured cabling & Server racks: 10 M Cat 6 Cable for DR |
187 | 15 M Cat 6 Cable for DR |
188 | 25 M Cat 6 Cable for DR |
189 | Cat-6 UTP Cable Roll of 305 Mtrs for DR |
190 | 12MTP/F-12MTP/F Trunk Cable, OM4, LSZH, 15m, polarity Reversed, Low-Loss for DR |
191 | 12MTP/F-12MTP/F Trunk Cable, OM4, LSZH, 25m, polarity Reversed, Low-Loss for DR |
192 | LC-LC Fiber Duplex Patch Cord OM4 Multimode-3 Meter for DR |
193 | LC-LC Fiber Duplex Patch Cord OM4 Multimode-5 Meter for DR |
194 | 24 Core Fiber Cassette (MPO) AB/BA Pair Flipped 24 Core fiber MPO LC Cassette, Pair Flipped AB/BA, Multi-Mode for DR |
195 | Trunk Cable (MPO-MPO) 25Meter MPO-MPO Trunk Male cable, 12 Fiber straight, 50.125 OM4 LSZH Multimode for DR |
196 | Trunk Cable (MPO-MPO) 15Meter MPO-MPO Trunk Male cable, 12 Fiber straight, 50.125 OM4 LSZH Multimode for DR |
197 | DR Site Installation, Commissioning & System Integration Charges |
198 | Server Rack - Supply, Installation, Testing & Commissioning of 42U, 7KWServer Cabinet Extruded Aluminium Profile frame with top panel; having static load bearing capacity of 1300 Kg as per Tender Specifications.Dimensions: 2200mm x 800mm x 1200mm all complete as required and as per detailed specifications. Racks, PDUs, containment should be from same OEM. for DR |
199 | Network Rack -Supply, Installation, Testing & Commissioning of 42U, 2KW network rack with PDU for DR |
200 | Manpower Requirement at DR Site for 24x7 Support: BMS Person for 5 years for DR |
201 | Manpower Requirement at DR site: IT - 1 L1 & 1 L2 engineer for 5 years for DR |
202 | Dedicated DC-DR Link 2x155 Mbps Leased Circuits from 2 different service providers with 1 Year ARC for DR |
203 | 1x100 Mbps ILL (1:1) at DR Site with 1 Year ARC for DR |
204 | Providing of 2 Nos physical security at SDC 1st floor for 1 year.FY-23-24 |
205 | Providing of 2 Nos physical securityat SDC 1st floor for 1 year.FY-24-25 |
206 | Providing of 2 Nos physical securityat SDC 1st floor for 1 year.FY-25-26 |
207 | FM Cost for 5 Years as per requirement mentioned in existing DCO terms & conditions for 1 year FY-23-24 for DC |
208 | FM Cost for 5 Years as per requirement mentioned in existing DCO terms & conditions for 1 year FY-24-25 for DC |
209 | FM Cost for 5 Years as per requirement mentioned in existing DCO terms & conditions for 1 year FY-25-26 for DC |
210 | AMC/Support Cost for lT (software and hardware) equipment for 1 year FY-23-24 for DC |
211 | AMC/Support Cost for lT (software and hardware) equipment for 1 year FY-24-25 for DC |
212 | AMC/Support Cost for lT (software and hardware) equipment for 1 year FY-25-26 for DC |
213 | AMC/Support Cost for Non-lT Equipment excluding UPS battery replacement (1st Floor) for 1 year FY-23-24 for DC |
214 | AMC/Support Cost for Non-lT Equipment (2nd Floor) for 1 year FY-24-25 for DC |
215 | AMC/Support Cost for Non-lT Equipment (2nd Floor) for 1 year FY-25-26 for DC |
216 | AMC/Support Cost for Non-lT Equipment (1st Floor) for 1 year FY-23-24 for DC |
217 | AMC/Support Cost for Non-lT Equipment (1st Floor)for 1 year FY-24-25 for DC |
218 | AMC/Support Cost for Non-lT Equipment (1st Floor)for 1 year FY-25-26 for DC |
219 | AMC/Support Cost for PAC, UPS, Panel & DG. (1st Floor) for 1 year FY-22-24 for DC |
220 | AMC/SupportCostfor PAC, UPS, Panel & DG. (1st Floor) for 1 year FY-24-25 for DC |
221 | AMC/Support Cost for PAC, UPS, Panel & DG. (1st Floor) for 1 year FY-25-26 for DC |
222 | Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level Engineer for 1 year FY-22-23. For 24X7 support for SIEM should include minimum 3 nos L2 level Onsite Resources for DC |
223 | Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level Engineer for 1 year FY-23-24. For 24X7 support for SIEM should include minimum 3 nos L2 level Onsite Resources for DC |
224 | Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level Engineer for 1 year FY-24-25. For 24X7 support for SIEM should include minimum 3 nos L2 level Onsite Resources for DC |
225 | Cost of dedicated Operation and AMC Support for RSA SIEM for WBSDC through L2 Level Engineer for 1 year FY-25-26. For 24X7 support for SIEM should include minimum 3 nos L2 level Onsite Resources for DC. |
226 | AMC/Support Cost for UPS batteries, for 612 cells of 2v/375ah, 132 nosbatteries of 12v/42 AHand 80 nos of batteries of 12v/200 AHfor 1 year FY-23-24 (batteries to be replaced as per OEM guidelines) at DC. |
227 | AMC/Support Cost for UPS batteries, for 612 cells of 2v/375ah, 132 nosbatteries of 12v/42 AHand 80 nos of batteries of 12v/200 AHfor 1 year FY-24-25 (batteries to be replaced as per OEM guidelines) at DC. |
228 | AMC/Support Cost for UPS batteries, for 612 cells of 2v/375ah, 132 nosbatteries of 12v/42 AHand 80 nos of batteries of 12v/200 AHfor 1 year FY-25-26 (batteries to be replaced as per OEM guidelines) at DC. |
229 | Professional Support Services for two Database and two System Administrators with effect from 1.4.2022 FY-22-23 for DC |
230 | Professional Support Services for two Database and two System Administrators with effect from 1.4.2023 FY-23-24 for DC |
231 | Professional Support Services for three Database and three System Administrators with effect from 1.4.2024 FY-24-25 for DC |
232 | Professional Support Services for three Database and three System Administrators with effect from 1.4.2025 FY-25-26 |
233 | Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2023 FY-22-23 for DC |
234 | Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2024 FY-23-24 for DC |
235 | Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2025 FY-24-25 for DC |
236 | Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2026 FY-25-26 for DC |
237 | Vodafone/other ISP 1000 Mbps ILL for WBSDC for 1 year upto 31.03.2027 FY-26-27 for DC |
238 | AMC & UPGRADE of old SDC cloud servers (4)FY-22-23 (NIC card from 1 to 10 GBPS and RAM 256 GB to 512 GB) for DC |
239 | AMC of old SDC cloud servers (4)FY-23-24 for DC |
240 | AMC & UPGRADE (30 to 75TB) of Dell VTL of old SDC cloud system period for 1 year FY-22-23 for DC |
241 | AMC of upgraded Dell VTL of old SDC cloud system period for 1 year FY-23-24 for DC |
242 | AMC & UPGRADE (75 to 100TB) of Dell VTL of old SDC cloud system period for 1 year FY-24-25 for DC |
243 | AMC of upgraded Dell VTL of old SDC cloud system period for 1 year FY-25-26 for DC |
244 | AMC / ATS & UPGRADE (from 40 to 50TB) of Commvault Backup System for 1 year FY-22-23 for DC |
245 | AMC / ATS & UPGRADE (from 50 to 60TB) of Commvault Backup System for 1 year FY-23-24 for DC |
246 | AMC / ATS & UPGRADE (from 60 to 70TB) of Commvault Backup System for 2 yearsFY-24-26 for DC |
247 | AMC of WBSDC new cloud (existing blade server) servers - lot one FY-23-24 for 1 year |
248 | AMC of WBSDC new cloud (existing blade server) servers - lot one FY-24-25 for 1 year |
249 | AMC of WBSDC new cloud (existing blade server) servers - lot one FY-25-26 for 1 year |
250 | AMC of Netapp SAN storage (430 TB) for the period for 1 year FY-23-24 for DC |
251 | AMC of Netapp SAN storage (430 TB) for the period for 1 year FY-24-25 for DC |
252 | AMC of Netapp SAN storage (430 TB) for the period for 1 year FY-25-26 for DC |
253 | AMC of WBSDC new network (SDN) infrastructure for 1 year FY-23-24 |
254 | AMC of WBSDC new network (SDN) infrastructure for 1 year FY-24-25 |
255 | AMC of WBSDC new network (SDN) infrastructure 1 year FY-25-26 |
256 | AMC & UPGRADE of RedhatOpenstack Cloud Software License SA for 1 year FY-23-24 for DC |
257 | AMC & UPGRADE of RedhatOpenstack Cloud Software License SA for 1 year FY-24-25 for DC |
258 | AMC & UPGRADE of RedhatOpenstack Cloud Software License SA for 1 year FY-25-26 for DC |
259 | Renewal of RSA Software Product Licenses with OEM support for 1 year FY-22-23. All underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
260 | Renewal of RSA Software Product Licenses with OEM support for 1 year FY-23-24. All underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
261 | Renewal of RSA Software Product Licenses with OEM support for 1 year FY-24-25. All underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
262 | Renewal of RSA Software Product Licenses with OEM support for 1 year FY-25-26. All underlying Hardware Infra required including VMware, Microsoft licenses etc will be provisioned by WTL and bidder to mention requirement with sizing for same in bid for DC |
263 | SOAR (Security Orchestration Automation Response) Software License Renewal for 1 year FY-24-25. For 24X7 support for SOAR renewal should include minimum 2 nos L2 level & 1 no L3 level Onsite Resources for DC |
264 | SOAR (Security Orchestration Automation Response) Software License Renewal for 1 year FY-25-26. For 24X7 support for SOAR renewal should include minimum 2 nos L2 level & 1 no L3 level Onsite Resources for DC |
265 | DDOS 10Gbps additional 1 Years subscription FY-24-25 for DC |
266 | DDOS 10Gbps additional 1 Years subscription FY-25-26 for DC |
267 | DC Augmentation - Installation, Commissioning & System Integration Charges |
268 | Deep Security Enterprise Software License - additional 50 VMs for 1 year during FY-22-23 for DC |
269 | Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses during FY-23-24 for DC |
270 | Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses for year FY-24-25 for DC |
271 | Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses for year FY-25-26 for DC |
272 | Deep Security Enterprise Software License - additional 50 VMs for 1 years & License renewals for all existing licenses for year FY-26-27 for DC |
273 | EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers) FY-22-23 for DC |
274 | EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers) FY-23-24 for DC |
275 | EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers) FY-24-25 for DC |
276 | EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers) FY-25-26 for DC |
277 | EDB Postgres Enterprise License CPU Core support renewal / upgrade - Production Support (including Replica DB servers) FY-26-27 for DC |
278 | Existing VMware vCloud Suite Subscriptionper CPU for 20 CPUs with 1 vCenter & Tanzu Commitment Plan - 12 month Prepaid with support FY-22-23 |
279 | Existing VMware vCloud Suite Subscriptionper CPU for 20 CPUs with 1 vCenter & Tanzu Commitment Plan - 12 month Prepaid with support FY-23-24 |
280 | Existing VMware vCloud Suite Subscriptionper CPU for 20 CPUs with 1 vCenter & Tanzu Commitment Plan - 12 month Prepaid with support FY-24-25 |
281 | Existing VMware vCloud Suite Subscriptionper CPU for 20 CPUs with 1 vCenter & Tanzu Commitment Plan - 12 month Prepaid with supportFY-25-26 |
282 | DC-DR LC & ILL ARC for DR Site FY-22-23 |
283 | DC-DR LC & ILL ARC for DR Site FY-23-24 |
284 | DC-DR LC & ILL ARC for DR Site FY-24-25 |
285 | DC-DR LC & ILL ARC for DR Site FY-25-26 |
286 | Capacitor Bank change of old UPS FY-22-23 for VERTIV make UPS |
287 | Capacitor Bank change of old UPS FY-24-25 for ETON make UPS |
288 | Electrical Earth Pit Repair / Reconstruction FY-22-23 |
289 | DG Repair / Replacement due to aging / obsolescence FY-22-23 |
290 | DG Repair / Replacement due to aging / obsolescence FY-24-25 |