Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior. Submission Date for this Tender is 23-03-2022. Conductor Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31205162
Corrigendum : Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
23-03-2022

Tender Details

Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior Special Repair Replacement Of Oh Conductor To Ug Cables In Residency Mess At Af Station Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.0 /-
Tender Value
INR 14.50 Lakhs /-

BOQ Items

Name of Work :SPECIAL REPAIR/REPLACEMENT OF OH CONDUCTOR TO UG CABLES IN RESIDENCY MESS AT AF STATION GWALIOR
Sl. No. Item Description
1Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT/HT Poles/Lines all as specified & directed.
2Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc.all as specified and directedincluding removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
3Returning, filling in including spreading, leveling, watering and well ramming in layers of25 cm thickafter the cables etc. are laid, jointed & tested complete all as specified and directed.
4Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directedat a level not exceeding 1.5 m above the starting point complete all as specified.
5Supply and lay for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall beconsidered as per clause 19.75 of SSR Part-I
6Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed.
7Disconnecting, taking out and removing old existing unserviceable/repairable underground, LT cable of any description and in any position complete including taking downprotection pipe,bricks etc all as specified and directedfor the following sizes:Note : Excavation /earth work shall be measerd and paid to seperately under relevant items of Sch.
8(a) 10 Sqmm to 25 Sqmm any core
9(b)35 Sqmm to 70 Sqmm3½core
10(c) 95 Sqmmto150 Sqmm 3½ core
11(d) 185 Sqmmto300 Sqmm 3½ core
12Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directedfor the following sizes :-.(NOTE : (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work.
13(a) 10 Sqmm to 25 Sqmm any core
14(b)35 Sqmm to 70 Sqmm3½core
15(c) 95 Sqmmto150 Sqmm 3½ core
16(d) 185 Sqmmto300 Sqmm 3½ core
17Supplying ,Laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable1100 volts grade ISI marked ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :-. MAKE:- Make : Havells Cable/National Cable Co/CCI/Gloster/Asian Cables/Incab/Finolex
18(a)10 Sqmm 2core
19(b)16 Sqmm 4core
20(c)35 Sqmm 3½ core
21(d ) 70 Sqmm 3½ core
22(e) 120 Sqmm 3½ core
23(f) 150 Sqmm 3½ core
24(g) 185 Sqmm 3½ core
25M & L in repairjointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, forsize 10 Sqmm to 16 Sqmm any core complete all as specified and directed by the Engineer-in-Charge. MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
26M & L in repairjointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, forsize 25 Sqmm to50 Sqmm ,3.5 core complete all as specified and directed by the Engineer-in-Charge.MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
27M & L in repairjointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, forsize 70 Sqmm to 120 Sqmm, 3.5 core complete all as specified and directed by the Engineer-in-Charge. MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
28M & L in repairjointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, forsize 150 Sqmm to185 Sqmm ,3.5 core complete all as specified and directed by the Engineer-in-Charge.MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
29Demolition for cement concrete/road in ground floor and paving not exceeding 15 cm thickness below or above ground level including removal of rubbish to a distance exceeding 1.50 Km butnot exceeding 5.00 Km etc complete all as specified and directed.
30M & L in replacement rusted pipe,laying & jointing 100 mm bore GI water tubing, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. MAKE:- TATA/JINDAL/SWASTIK
31M & L in replacement rusted pipe,laying & jointing 50 mm bore GI water tubing, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. MAKE:- TATA/JINDAL/SWASTIK
32M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation/repairs to damaged road/footpath/plinth for panels etc. including necessary formwork complete all as specified & directed.
33M&L for PCC 1:2:4,type B-1 (using 20mm graded crushedstone aggregate) as in repair to footpath/hard standing/plinth for panels etc. including necessary formwork complete all as specified & directed.
34Supply, Installation, testing factory made LT Feeder Pillar Box (of size 60 cmx45cmx30cm for 3 Phase, 4 Wire, 415 Volts, AC, 50 Hz, Outdoor, Cubical Type, Weather, Dust and Vermin proof, Pedestal mounting type, front operated applications having size of Aluminium bus bar rating capacity 400 Amps and neutral 300 Amps rating capacity mounting of insulators, Controlled by MCCB, 100 Amps, 3 pole, 415 Volts, AC supply,having breaking capacity Icu = 16 KA fixed type, on incomming side, canopy on top and gland provision in the bottom made out of 3.15 mm thick MS sheet duly powder coated of approved shade with using 40mmX40mmX6 mm angle iron frame and supports including necessary excavation and grouting work in PCC 1:2:4 Mix, Type B1 complete all as specified and directed.
35Supplying and fixing in position new PVC (Sinthetic) boxes of size 280mm X 170mm X 115mm depth, made out with Sinthetic.The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 2 Nos mounted on porcelain insulators including one No. MCB SP of ‘C’ series, 5/6 Amps of Make Legrand/L&T/ Siemensand connecting the bus bars to cables withusing suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5 mm GI clamps, nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. (Note :-The contractors quoted rates for the above items are deemed to include for fixing the Synthetic box in position with suitable MS clamps and/or necessary PCC as per site requirement.)
36M & L for earthing complete with Gl electrode of size 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X6 mm as mainearthing lead by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwedincluding 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip includinglaying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x3mm mild steelangle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm gradedcrushed stone aggregate) reinforced with 8mm dia TMTbars @ 75mm C/C both way with mild steelhandle 12 mm dia round bars ,10mm thick plastering withcement mortar(1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed. Note: (i) Earth stripand its protection pipe up to and including 7.5 mtr only from the top of earth electrode are included in this item. (ii)Test result of earthing to be submitted by the contractor for all earthing. (iii) Earth filling shall be done by vegetable soil. (iv) Soil should be free from stone, boulders,aggragates,gravel etc. (v) The rate quoted by the bidders shall be also be deemed to include :-(a)Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.
37M & L for earthing complete with Gl electrode of size 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl wire 4mm dia as mainearthing lead by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwedincluding 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 15 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip includinglaying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x3mm mild steelangle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm gradedcrushed stone aggregate) reinforced with 8mm dia TMTbars @ 75mm C/C both way with mild steelhandle 12 mm dia round bars ,10mm thick plastering withcement mortar(1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed. Note: (i) Earth stripand its protection pipe up to and including 7.5 mtr only from the top of earth electrode are included in this item. (ii)Test result of earthing to be submitted by the contractor for all earthing. (iii) Earth filling shall be done by vegetable soil. (iv) Soil should be free from stone, boulders,aggragates,gravel etc. (v) The rate quoted by the bidders shall be also be deemed to include :-(a)Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.
38S&F PVC insulated, sheathed twin core 2.5 Sqmm size aluminium wire duly passing through the holes of existing steel poles/ street light brackets including necessary connection at pole mounted street light junction box and at the street light luminaries all as specified and directed.
39M&L for making two holes (each hole of 20 mm dia) in existing street light steel tubular pole by using gas welding/ electric arc welding for insertion of wire for street lights. The holes should be made first at 1500 mm above ground level and second 1200 mm below top end of the pole including grinding the surface of pole for proper smoothness all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail