| 1 | COST OF HVAC SYSTEMS - VRF - PARADIP PORT HOSPITAL - EMERGENCY BLOCK |
| 2 | Supply Part of Equipments |
| 3 | Supply of City Multiinverter technology based minimum 14 HPCapacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only modealong with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 4 | Supply of VRF 4-Way Cassette type unit of minimum capacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 5 | Nominal Capacity - 1.06 TR |
| 6 | Nominal Capacity - 2 TR |
| 7 | Nominal Capacity - 3.2 TR |
| 8 | Supply of VRF Hi-Static Ductablesplit type unit of minimumCapacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower etc. in all respect suitable for 24±4 degree Celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 9 | Nominal Capacity - 0.8 TR |
| 10 | Nominal Capacity - 0.6 TR |
| 11 | Installation Part |
| 12 | Installation , testing and commissioning of minimum 14 HPCapacity VRF System as at \"A\" above |
| 13 | Installation , testing and commissioning VRF 4-Way Cassette type unit as at \"B\" above with minimum capacity as given below: |
| 14 | Nominal Capacity - 1.06 TR |
| 15 | Nominal Capacity - 2 TR |
| 16 | Nominal Capacity - 3.2 TR |
| 17 | Installation, testing and commissioning VRF Hi-Static Ductable split type unit as at \"C\" above with minimumCapacity as given below: |
| 18 | Nominal Capacity - 0.8 TR |
| 19 | Nominal Capacity - 0.6 TR |
| 20 | Supply, Installation,testing and commissioning of Suction and liquid line of 18/20 Gauge copper piping with 13mm /19 mm thik Nitril rubber Insulation-Class O Grade , with all respect for complete commissioning of systems. Copper Pipe.Make: Reputed |
| 21 | Supply , Installation,testing and commissioning of 2 core X 1.5 Sqmm Electrical communication cabling with conduit pipe, and clamps etc. all complete. Make : Reputed |
| 22 | Supply, installation and commissionig of PVC Drain water pipe with Insulation and required ancillary items, all complete. Make : Reputed |
| 23 | Refrigerant R410a/407C Gas for Commissioning of the VRF Systems |
| 24 | Transportation, loading, unloading of Machines and Materials |
| 25 | HVAC SYSTEMS - VRF - PARADIP PORT HOSPITAL - O T BLOCK |
| 26 | Supply Part of Equipments |
| 27 | Supply of City Multiinverter technology based minimum 14 HPCapacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only modealong with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 28 | Supply of VRF 4-Way Cassette type unit of minimum capacity - 1.06 TR with necessary items like expansion valve, cooling coil , filter section, blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 29 | Supply of VRF Hi-Static Ductabletype unit of minimumCapacity 4.6 TR with necessary items like expansion valve , cooling coil , filter section , blower etc in all respect. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 30 | Installation Part |
| 31 | Installation , testing and commissioning of minimum 14 HPCapacity VRF System as at \"A\" above |
| 32 | Installation , testing and commissioning VRF 4-Way Cassette type unit of minimum-1.06 TR capacity as at \"B\" above |
| 33 | Installation, testing and commissioning VRF Hi-Static Ductabletype unit of minimumCapacity 4.6 TR as at \"C\" above |
| 34 | Supply, Installation,testing and commissioning of Suction and liquid line of 18/20 Gauge copper piping with 13mm /19 mm thik Nitril rubber Insulation-Class O Grade, with all respect for complete commissioning of systems. Copper Pipe Make: Reputed |
| 35 | Supply , Installation,testing and commissioning of 2 core X 1.5 Sqmm Electrical communication cabling with conduit pipe, and clamps etc. all complete. |
| 36 | Supply , installation and commissionig of PVC Drain water pipe with Insulation and required ancillary items, all complete. Make : Reputed |
| 37 | Refrigerant R410a/407C Gas for Commissioning of the VRF Systems |
| 38 | Supply and installation of AISI 316 grade 22 Gauge thickness Stainless steel Ducting with supporting items like Thread rod , Perforated channel, Fastner, nut-bolt etc, all complete, as required in all respect. Make: Reputed |
| 39 | Supply and installation of 13 mm thick Nitril rubber O class insulation added self Alluminium foil face with all types of ancillary items. Make : Reputed |
| 40 | Transportation, loading, unloading of Machines and Materials |
| 41 | PPT COVID WARD INFRASTRUCTURE BOQ |
| 42 | WALLAntibacterial homogenous 1mm wall vinyl covering along with Smooth putty and primer on the wall . |
| 43 | Anti bactrial anti static FLOOR of 2mm Homogenous antibacterial vinyl with welding on the edges, Copper stripping to be done and proper earthing to be done.: The 2 mm homogeneous material incorporates homogenousity throughout its full thickness and should carry warranty of 5yrs after laying. The product should comply with EN 649. The product is non-reactive to residual indentation with a value = 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-s1 fire resistance. The product is non-emissive of volatile organic compounds with < 10 Micro Gm(TVOC after 28 Days ISO -16000-6 ).The material should be laid after doing self levelling with self levelling compound. |
| 44 | Self Levelling -Floor. |
| 45 | Clean room doors:Manully operated Clean room Single leaf Hinge door (1200mm wide 2100mm height) complete with double toughned glass vision window in leaf. Made of SS-304 With Gasket and drop seal.Make : Metaflex |
| 46 | Clean room doors:Manully operated Clean room Single leaf Hinge door (900 mm wide 2100mm height) complete with double toughned glass vision window in leaf. Made of SS-304 With Gasket and drop seal. Make : Metaflex |
| 47 | Clean room doors:Manully operated Clean room Double leaf Hinge door (1500mm wide 2100mm height) complete with double toughned glass vision window in leaf. Made of SS-304 With Gasket and drop seal. |
| 48 | Clean Room LED Light for Isolation ward Make: Philips |
| 49 | CEILING For Isolation Wards : 6MM Calcium silicate greed ceiling with antibacterial paint of Jutton/Sika/ESDDE or equivelant |
| 50 | HVAC SYSTEMS - VRF - PARADIP PORT HOSPITAL - COVID WARD |
| 51 | Supply Part of Equipments |
| 52 | Supply of City Multiinverter technology based following Capacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only modealong with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 53 | Nominal Capacity - 14 HP |
| 54 | Nominal Capacity - 20 HP |
| 55 | Supply of VRF 4-Way Cassette type unit of minimum capacity as given below, with necessary items like expansion valve, cooling coil, filter section,blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea |
| 56 | Nominal Capacity - 0.8 TR |
| 57 | Nominal Capacity - 2 TR |
| 58 | Nominal Capacity - 2.5 TR |
| 59 | Installation Part |
| 60 | Installation , testing and commissioning of VRF System as at \"A\" above with minimum capacity as given below: |
| 61 | Nominal Capacity - 14 HP |
| 62 | Nominal Capacity - 20 HP |
| 63 | Installation , testing and commissioning VRF 4-Way Cassette type unit as at \"B\" above with minimum capacity as given below: |
| 64 | Nominal Capacity - 1.5 TR |
| 65 | Nominal Capacity - 2 TR |
| 66 | Nominal Capacity - 2.5 TR |
| 67 | Supply, Installation,testing and commissioning of Suction and liquid line of 18/20 Gauge copper piping with 13mm /19 mm thik Nitril rubber Insulation-Class O Grade, with all respect for complete commissioning of systems.Make: Reputed |
| 68 | Supply, Installation, testing and commissioning of 2 core X 1.5 Sqmm Electrical communication cabling with conduit pipe, and clamps etc. all complete. Make : Reputed |
| 69 | Supply, installation and commissionig of PVC Drain water pipe with Insulation and required ancillary items, all complete. Make : Reputed |
| 70 | Supply and installation of AISI 316 grade 22 Gauge thickness Stainless steel Ducting with supporting items like Thread rod, Perforated channel, Fastner, nut-bolt etc, all complete, as required in all respect. Make: Reputed |
| 71 | Supply and installation of 13 mm thick Nitril rubber O class insulation added self Alluminium foil face with all types of ancillary items. Make : Reputed |
| 72 | Supply and installation of Alluminium powder coated Diffuser/Grillfor Return Air with damper with all tyeps of ancillary items . |
| 73 | Supply, Installation, testing and commissioning of 3 stage Filter (10 micron Pre-Filter, 5 micron Fine Filter and 0.03 Micron Hepa Filter) fitted cabinet typeAxial Flow exhaust fan with Centrifugal Backward/forward Curve blower, Fan as of below-mentionedcapacity for Negative pressure Zone.[Fan design & Static Pressure may be change as per the site condition or Filter may be installed in ducting as required] |
| 74 | 250 CFM (Static pressure 85 mm) |
| 75 | 200 CFM(Static pressure 85 mm) |
| 76 | 100 CFM(Static pressure as 15 mm) |
| 77 | Supply, installation of Fire retardant Flexible Canvas Connection for Exhaust Fan Mouth connection with requiredancillary itmes |
| 78 | Supply, Installation, testing and commissioning of Fresh air fan, the Fan will be made by Single stage Filter (10 micronPre- Filter), cabinet type Axial Flow type, Centrifugal Backward/forward Curve blower, Ceilling suspended type, Fan capacity is 300 CFM 30 MM Static pressure for possitive pressure Zone. The system will be comfortable with UVGI inside the fan to kill the bacteria growth. |
| 79 | Refrigerant R410a/407/C Gas for Commissioning of the VRF Systems |
| 80 | Transportation, loading, unloading of Machines and Materials |
| 81 | Comprehensive Annual Maintenance Contract of entire HVAC System (for the HVAC System of Air Borne Respiratory Infection Isolation Ward,Emergency Block, and OT Block) for Five Years |
| 82 | For 1st Year |
| 83 | For 2nd Year |
| 84 | For 3rd Year |
| 85 | For 4th Year |
| 86 | For 5th Year |