}

Soundand Vibration Device Sound And Vibration Device With Associated Genuine Accessories , Sound And Vibration Device With Associated Genuine Accessories , 102.4 Ks / S, 100 Db, 0.8 Hz Ac / Dc Coupled, 4-Input / 1-Output Sound And Vibration Device, , kothamangalam-Kerala

Directorate Of Technical Education-DTE has published Soundand Vibration Device Sound And Vibration Device With Associated Genuine Accessories , Sound And Vibration Device With Associated Genuine Accessories , 102.4 Ks / S, 100 Db, 0.8 Hz Ac / Dc Coupled, 4-Input / 1-Output Sound And Vibration Device, . Submission Date for this Tender is 02-03-2022. Couplings Tenders in kothamangalam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

31137981
Soundand Vibration Device Sound And Vibration Device With Associated Genuine Accessories , Sound And Vibration Device With Associated Genuine Accessories , 102.4 Ks / S, 100 Db, 0.8 Hz Ac / Dc Coupled, 4-Input / 1-Output Sound And Vibration Device,
Open Tender
Indian
Kerala
kothamangalam
02-03-2022

Tender Details

Soundand Vibration Device Sound And Vibration Device With Associated Genuine Accessories , Sound And Vibration Device With Associated Genuine Accessories , 102.4 Ks / S, 100 Db, 0.8 Hz Ac / Dc Coupled, 4-Input / 1-Output Sound And Vibration Device, Input Channels - 4, Input Connector - 1 Bnc Per Channel, Pc Communication - Usb 2.0, Power Consumption - 2.5 W Max, Adc Resolution - 24 Bits, Adc Type - Delta-Sigma, Sampling Mode - Simultaneous, Sample Rates ( Fs ) : Range 1 Ks / S To 102.4 Ks / S And Resolution - 2.10 Ms / S.Internal Frequency Time Base Accuracy - ±100 Ppm Max, 4 Input Channels Simultaneously Digitize Input Signals, Ao Channel Must Beideal For Stimulus-Response Tests And Can Be Synchronized To The Ai Channels, Input Channels Should Incorporate Integrated Electronic Piezoelectric ( Iepe ) Signal Conditioning For Accelerometers And Microphones. Input Range - ±10 Vpk, Fifo Buffer Size - 1, 023 Samples ( Shared Between All Channels ) . Input Coupling - Ac Or Dc, Each Channel Independently Software Selectable, Programming Language – Graphical Coding Labview Compatible , Compatible With Matlab. Iepe Excitation, Channels - Ai0, Ai1, Ai2, Ai3, Current 0 Or 2.1 Ma, Each Channel Independently Software Selectable, Compliance Voltage - 20 V Min, Output Impedance - 200 Kohm At 1 Khz, Current Noise Density - 25 Pa / At 10 Khz, Fault Detection, Thresholds - <1.5 V ( Short ) , >19.5 V ( Open ) , Indication - Software, Per Channel, - Output Channels - 1, Ao Signal Connection - Bnc, Ao Frequency Range - Dc To 43.5 Khz, Internal Frequency Time Base Accuracy - ±100 Ppm Max, Dac Resolution- 24 Bits, Dac Type- Delta-Sigma, Output Signal Range - ±3.5 Vpk, Bnc Male To Bnc Male Cable, 50 Ohm, 1 M ( 5 Nos Per Device Unit ) , Support And Standard Warranty For One Year , Frequency Resolution - 1 Hz

Key Value

Document Fees
Refer document
EMD
INR 12000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: NRB-ECD
Sl. No. Item Description
1Sound and Vibration Device with associated genuine accessories
2102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device, Input channels - 4, Input connector - 1 BNC per channel, PC communication - USB 2.0, Power consumption - 2.5 W max, ADC resolution - 24 bits, ADC type - Delta-sigma, Sampling mode - Simultaneous, Sample rates (fs) : Range 1 kS/s to 102.4 kS/s and Resolution - 2.10 mS/s.Internal frequency time base accuracy - ±100 ppm max,4 input channels simultaneously digitize input signals, AO channel must beideal for stimulus-response tests and can be synchronized to the AI channels,Input channels should incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. Input range - ±10 Vpk, FIFO buffer size - 1,023 samples (shared between all channels). Input coupling - AC or DC, each channel independently software selectable, Programming Language – Graphical Coding labview compatible , compatible with Matlab. IEPE Excitation, Channels - AI0, AI1, AI2, AI3,Current 0 or 2.1 mA, each channel independently software selectable,Compliance voltage - 20 V min,Output impedance - 200 kohm at 1 kHz, Current noise density - 25 pA/ at 10 kHz, Fault detection,Thresholds - <1.5 V (short), >19.5 V (open), Indication - Software, per channel,- Output channels - 1, AO signal connection - BNC, AO frequency range - DC to 43.5 kHz,Internal frequency time base accuracy - ±100 ppm max,DAC resolution- 24 bits, DAC type- Delta-sigma, Output signal range - ±3.5 Vpk, BNC Male to BNC Male Cable, 50 Ohm, 1 m (5 Nos per device unit), support and standard warranty for one year
3Frequency Resolution - 1 Hz
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail