Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS(PART-I)Clearing & Grubbing the road land including uprooting rank vegetation grass, bushes, shrubs, saplings and trees girth upto 300m, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm in thickness. |
| 2 | Earth work in excavation of foundation in ordinary soil including dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and directionof Engineer in charge |
| 3 | Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge. |
| 4 | Filling foundation trench and plinth withexcavated earth with well watered and rammed in layers not exceeding 23cm in depth with allleads and liftsincludingcost conveyance taxesof all materials and labour etc complete as per specification and direction of Engineer in charge |
| 5 | Loosening,levelling and compacting original ground supporting embankement to faciliate placement of first layer of embankement,scarified to a depth of 150 mm,mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction & clause-305 of MOSRT&H Specifications for Road & Bridge works(5th. Revision) |
| 6 | Providing and injecting chemical emulsion for pre - constructional anti-termite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top-surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost of all materials and labour taxes etc. complete. (indemnity bond for warranty for 7 years to be furnished) |
| 7 | Cement concrete (1:4:8) in foundation and plinth using 40mm size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 8 | RCC work ofM-25 Grade with 20mm and down graded size crushed stone aggregates mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all materials with all labour, T&P,etc. complete as per direction and specification of Engineer-in-charge. Foundation |
| 9 | Column in superstructure |
| 10 | Beams |
| 11 | Roof Slab |
| 12 | Lintel along with mullion and Tie Beam |
| 13 | Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge |
| 14 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 15 | Construction of granular sub-base by providing Close graded Granular subbase Grading-IV material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MORTH Specifications for Road & Bridge works (5th Revision) |
| 16 | Providing, laying, spreading and compacting graded stone aggregate to Wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406 of MORT&H specification for Road and Bridge works(5th Revision) as directed by the Engineer in charge |
| 17 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation & Plinth and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor |
| 18 | Fly Ash Bricks masonry of sizie(25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor |
| 19 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:4) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor |
| 20 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 21 | Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 22 | Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 23 | Finishing wall surface with cement based wall putty(water based) of approved make and finished smooth and even surface to receive paintingincluding cost of scaffolding staging charges, conveyance, taxes of all materials and cost of all labour with TandP etc complete as per specification and direction of Engineer in charge |
| 24 | Painting two coats withPlastic Emulsion paints of approved colour, shade over a coat of prime to iside surface including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge |
| 25 | Painting two coats with anti-fungal resistance Weather Seal Coat of approved shade over a coat of primer upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge |
| 26 | Painting two coats with approved Synthetic Enamel paints of approved colour, shade over a coat of primer in wood or iron work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge |
| 27 | SupplyingProviding and fixing of 18G MS rolling shutter components are CRC Steel Sheets as per IS 6248, MS Bottom Plate, MS Side guides, MS Brackets, MS Shaft Assembly and Hood Cover with powder coating finish and Necessary Hardwares complete in all respect as desired by the Engineer in charge. |
| 28 | Supplying , Making, Installation and Polishing of Plain design khandolite stone cladding work 2\"\" thick as per approved design and details shared by the architect as per direction of Engineer in charge. |
| 29 | Supply, Making, Installation and Polishing of Ornamental design khandolite stone cladding work 3\"\" thick as per approved design and details shared by the architect/ as per direction of Engineer in charge. |
| 30 | Providing and fixing of signages with required base preparation and foundation as per approved design and details shared by the architect as per direction of Engineer in charge. |
| 31 | Providingfitting and fixing of Granite tilein floors of approved sizeover 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 32 | Providingfitting and fixing of Granite tile in Dadoes and skirting of approved sizeover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 33 | Providing & Fixing of 125 x 6mm finished section Door frames made out of duly Kiln seasoned as per IS-1141 & ASCU Chemically pressure treated as per IS-401 Sal wood edges of frames are moulded suitable with shatter finish grooves single or double, complete as per IS-402/95. One coat of Coal tar on wall sides and other sides with pink wood primer as per instructions of Engineer Incharge TD1 1190x2485mm |
| 34 | TD2 840x2145mm |
| 35 | Providing and fixing of 32mm thick flush doors shutters of block boards construction. Flush doorframes are 95mm width, made out of duly seasoned as perIS-1141 & chemically pressed treated as per IS-401, 2nd class hardwood as per IS-12896. The block board used are seasoned & treated, bonded with 2.5mm core veneer & face veneers on both sides to form7 ply construction as per IS-2202/Part-I. Veneer bonded with block board cross band or vertical by phenol formaldehyde synthetic resin as per IS-848 under hot press, with 1mm (Make: Merino) sude finish Laminate both side and required hardware (Make: Godrej) 4 Nos SS Hinges (125 x 75 x 3mm) 4 Ball bearing, 1 set SS304 Tube lever Handle with LockBody and 1 Nos 60mm 1CK Cylinder (Make Godrej) complete in respect as per the instructions of Engineer Incharge. (Door closer will be extra if required) 1100mmx2450mm TD1 |
| 36 | TD2 750x2100mm |
| 37 | Providing and fixing Aluminium Italian system series high performance Ventilator/window series with Italian series extrusion, microwave, cured EPDM gasket imported hardwares, super durable powder coating of minimum thickness 60 microns from axzonobel with 8mm Toughened glass (saint gobain). The system will be designed to meet 2.2 KPa wind pressure providing high quality insulation against air infiltration, water ingress, sound and air pollution all respect as directed by Engineer InchargeV-600x500mm |
| 38 | Providing and laying flamed finish Khandolite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all completeas per the architectural drawings with 18 mm thick stone slab over 25 mm(average) thick base of cement mortar 1:1 (1 cement : 1 coarse sand) laid andjointed with cement slurry and pointing with white cement slurry admixed withpigment of matching shade including rubbing, curing and polishing etc. allcomplete as specified and as directed by the Engineer-in-Charge : |
| 39 | Providing and laying of 80mm thick factory cut grey cobble stone Paver block and approved make variety colour and size made by Block making machin with strong vibratory compaction of approved design and shape, laid in required colour and pattern over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete including cost, conveyance, royality, taxes of all materials, labour, T&P etc. complete as per direction of EIC. |
| 40 | Supplying and stacking of good quality earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) as per direction of Engineer in charge. |
| 41 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm as per direction of Engineer in charge |
| 42 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 43 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 44 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
| 45 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 46 | Supplying and planting of shrubs/climbers/creepers/ground cover of the specified species,including cultivation of planting bedmixed with well decomposed Horse manure / cowdung (\"20mm\"ofmanure, \"40mm\" fine river sand mixed throughly with red garden soilas per direction. The filled soil shall be mixed with neem cake pesticide and bone meal in the required proportions as suggested by architect.Ixora Chinensis red of 1\"6\" minimum height |
| 47 | Codiacumvariegatum dwarf 1\"2\"\" minimun height |
| 48 | Pasiflora coccinea of minimum height 2\"0\"\" |
| 49 | Hibiscus rosa-sinensis |
| 50 | Hamelia patens minimum height 2\"3\"\" |
| 51 | Providing and dibbling of good quality lawnof the specified species in lawn area, with clods broken completely, and removal of debris and unwanted materials. Soil mixture shall be of 15% manure, 20% river sand,and 65% red earth. The filled soil shall be mixed with neem cake/Pongamia cake, pesticide in the required proportions. |
| 52 | Supplying and planting trees of the specified species,including cultivation of planting bedmixed with well decomposed Horse manure / cowdung (\"20mm\"ofmanure, \"40mm\" fine river sand mixed throughly with red garden soilas per direction. The filled soil shall be mixed with neem cake pesticide and bone meal in the required proportions as suggested by architect. Ficus benghalenis 8\"0\" of recorded height andwith minimum spacing of 4.00 m c/c |
| 53 | Bombax ceiba9\"0\"\" of recorded height andwith minimum spacing of 6.00 m c/c |
| 54 | Azadirachta indica 1.00m + of recorded height andwith minimum spacing of 6.00 m c/c |
| 55 | Millingtonia Hortensis 9\"0\"\" + of recorded height andwith minimum spacing of 6.00 m c/c |
| 56 | Construction of cement concrete kerb stone with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 |
| 57 | Providing, Fitting & Fixing of Stainless steel of 304 grade in hand railing of 50mm outer diameter of 2mm thick of approved Quality & Specification with balustrade of size 32mmX32mmX2mm square pipes in rows including Cost of all Materials, Labour for fabrication, buffing & polishing, cost of all fixtures etc. Complete and as per specification & direction of Engineer-in-charge |
| 58 | Redevelopment & Beautification of existing temple in the site cost to include External, Internal & Providing all the necessary electrical, Mechanical & Phe Services |
| 59 | E.I. Works:-EXTERNAL LIGHTING FEEDER PILLAR - 2 Supply, Installation, Testing and Commissioning of EXTERNAL LIGHTING FEEDER PILLARshall be as per Single line drawing and specifications.INCOMER:63A TPN MCCB with O/C, S/C Releases - 1 No.SUB INCOMER-1:32A DP RCBO with 30mA - 1 No.32A TP AC3 DUTY CONTACTOR - 1No.SUB INCOMER-2:32A DP RCBO with 30mA - 1 No.32A TP AC3 DUTY CONTACTOR - 1No.SUB INCOMER-3:32A DP RCBO with 30mA - 1 No.32A TP AC3 DUTY CONTACTOR - 1No.OUT GOING FEEDERS:10/16A SP MCB - 18 Nos.BUS BARS:10/16A SP MCB - 24 Nos.BUS BARS:CRCA Sheet steel with powder coated enclosure of size L1000mm x H1800mm x D400mmForm 3B Construction. |
| 60 | Supply, Installation of 2Kg Co2 fire extinguisher, temperature range from -30°C to +60°C, manufactured in accordance to EN 3-7:2008,certified according to the directive for pressure equipment PED 2014/68/EU.Suitable for use on fire involving electrical voltages up to 1000 V, at a distance of 1 mtr. |
| 61 | DISTRIBUTION BOARDS:Supplying and fixing follwoing .... way single pole MCB in sheet steel encloser distribution board,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, detachablegland plate, interconnections, phosphatized and powder painted including earthing etc., as requiredLDB -TYPE-14 Way TPN MCB DBIncomer :1 No. 63A 4P RCBO 30mA3 No. 25A DP MCBOutgoings :12 nos. of 10/16A SP MCBs |
| 62 | LT Cable & Cable End Termination Supply, installation, testing and commissioningon cable tray/surface/trench/burried offollowing size of 1.1KV grade multicore stranded aluminium/ copper conductor XLPE / PVC insulated & PVC sheathed armoured/ unarmoured cable (FR Type) as per IS: 7098 (Part-1) 1988 complete as required, as per below:3.5X35 SQMM AL. XLPE ARM.CABLE |
| 63 | Supply, installation, testing and commissioningon cable tray/surface/trench/burried offollowing size of 1.1KV grade multicore stranded aluminium/ copper conductor XLPE / PVC insulated & PVC sheathed armoured/ unarmoured cable (FR Type) as per IS: 7098 (Part-1) 1988 complete as required, as per below:3CX4 SQMM CU. ARM. CABLE |
| 64 | Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required.3.5X35 SQMM AL. XLPE ARM.CABLE |
| 65 | Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required.3CX4 SQMM CU. ARM. CABLE |
| 66 | Wiring system- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm OHFRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC conduit ( Thickness not less than 2mm), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required..Group A (3.0 mts length) |
| 67 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm OHFRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC conduit ( Thickness not less than 2mm), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required..Group B (4.,0 mts length) |
| 68 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm OHFRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC conduit ( Thickness not less than 2mm), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required..Group C (5. mts length)Note: The wiring length for light control, exceeding 5.0 mts, the additional length of wiring shall be measured separately as part of circuit wiring |
| 69 | Recessed wiring to LIGHT/CEILING FAN/EXHUST FAN pointpoint with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit - Secondary |
| 70 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed Heavy class PVC conduit ( Thickness not less than 2mm), 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 71 | Supplying and fixing of3pin 5 / 6 amps socket outlet and 10 amps modular type switch with 3 module GI box of 18G, modular plate, cover and with necessary fixing accessosries and inter connections etc., all complete as required. |
| 72 | Supplying and fixing of3pin 6/16 amps socket outlet and 16 amps modular type switch with 3 module GI box of 18G, modular plate, cover and with necessary fixing accessosries and inter connections etc., all complete as required. |
| 73 | CIRCUIT MAIN / POWER MAIN / SUBMAINS : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 74 | LIGHT & FAN FIXTURES:Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warrantyBollard 8W LED |
| 75 | Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warrantyLandscape Spot Lights Wattage : 1 x 45W LED |
| 76 | Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warrantyLandscape PathFinder LightWattage : 12W LED |
| 77 | Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warrantyPolar Lighting Pole, Wattage : 1 x 50W LED, Ht.6000 |
| 78 | Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warrantyLighting Pole, Wattage : 2 x 50W LED, Ht.6000 |
| 79 | Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warranty9W Led Ceiling Recess/surface Mounted Down Light |
| 80 | Supply, Installation, Testing and Commissioning of LED Luminairewith aluminium extruded profile finished in white powder coating, snap fit high translucent frosted PMMA diffuser and high reflective aluminium reflector complete with electronic driver, Power factor = 0.95, THD = 10%, rated life of L-70@50000 hrs with system lumen output = lumen and system luminious efficacy = 95-110lm/W. The Luminaire shall have a CRI = 80.Supply of all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings including luminaire, LED lamp, driver/ballast and all other accessories all complete as required.(For make and selection please refer architectural selection sheet. vendor to quote as per sheet or equivalent fixture as per sheet). All Light fixtures to be supplied with 5 years warranty12W Surface Mounted Led Light |
| 81 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(For Electrical Systems)20 mm |
| 82 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(For Electrical Systems)25 mm |
| 83 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(For Electrical Systems)32 mm (Landscape Lights) |
| 84 | Earthing system- Providing and laying of 600 x 600 x 6 mm GI plate with 2 Nos. 50 x 6 mm GI tape form earth electrode to inspection chamber, 20mm dia medium class GI pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 300 x 300 mm with concrete base CI manhole cover having locking arrangement with frame painted with bitumastic paint and packing with mixtures of charcoal and common salt around plate electrode including digging of pit upto permanent moisture level but not less than 3 meter and black filling as required. |
| 85 | Supplying and laying 25x5mm, GI earth strip ISI marked at 0.5 Mtr. below ground level as strip earth electrode including soldering etc., as required |
| 86 | Supplying and laying of6 SWG, GI wire on surface or in recessfor loop earthing as required |
| 87 | IP CCTV SURVEILLANCE SYSTEM Supply, Installation, Testing & Commissioning of following:Compact outdoor, 4MP resolution, day/night, fixed bullet camera providing Forensic WDR and Lightfinder for demanding light conditions. IR corrected varifocal 2.8-8.5 mm F1.2 P-iris lens withremote 3x optical zoom and focus. Multiple, individually configurable H.264 and Motion JPEG streams; max 4MP at 25/30 fps in 16:9 format. Axis Zipstream technology for reduced bandwidth and storage needs. Video motion detection, active tampering alarm, shock detection and corridor format. Audio mic/line in, I/O for alarm/event handling and memory card slot for optional local video storage. Optimized IR, a power-efficient IR LED technology covering 30 meters (98 feet). Integrated bracket for easy mounting on wall and ceiling. NEMA 4X, IP66/67 and IK10-rated for operation in -40°C to +60°C(-40 °F to 140 °F). Powered by IEEE 802.3af Type 1 Class 3 midspan (PoE). Midspan not included. |
| 88 | Supply, Installation, Testing & Commissioning of following:PTZ camera with continues 360° pan for both indoor and outdoor with 32x optical zoom, Lightfinder 2, Autofocus and Focus Recall. HDTV 1080p @ 25/50fps (1920x1080) in Motion JPEG, H.264, H.265, and AxisZipstream. Two-way audio, 4xI/O, 24V and PoE, Day & Night, IP66, IK10 and NEMA 4X classification. Advanced Gatekeeper, full-size SD-card slot. Mounting brackets, Midspan/Power supply and connector or cable for audio, I/O and 24V are not included. |
| 89 | Supply, Installation, Testing & Commissioning of following:24 Port gigabit POE Layer 2 switch 10/100/1000 24 Port all POE+(190W) switch with 2 SFP uplinks L2 Smart managed switch |
| 90 | 6 core single mode fiber cable |
| 91 | UTP CAT6 Cable |
| 92 | 25mm PVC cassing caping |
| 93 | PVC conduit pipe |
| 94 | CAT6 UTP Patch Cord 3mtr |
| 95 | Testing, Commissioing, training and Handover |
| 96 | Supply&layingofthefollowingHDPEpipeson Surface / wall / below ground and/or paved areas fordrawing / protecting insulated / barewires/ loopearthingconductors complete as required and as below (6 Kg. Pressure).50 mm dia |
| 97 | Supply&layingofthefollowingHDPEpipeson Surface / wall / below ground and/or paved areas fordrawing / protecting insulated / barewires/ loopearthingconductors complete as required and as below (6 Kg. Pressure).25 mm PVC conduit |
| 98 | Supply&layingofthefollowingHDPEpipeson Surface / wall / below ground and/or paved areas fordrawing / protecting insulated / barewires/ loopearthingconductors complete as required and as below (6 Kg. Pressure).25 mm Cashing Caping |
| 99 | 3\" G. I. Pole 4 Mtr. with foundation for outdoor Bullet Camera & Speaker. |
| 100 | Mounting Bracket |
| 101 | PUBLIC ADDRESS SYSTEM 50W Multi-Tap , Pole Mount Horn Speakers. The speakersshall be of same make as that of the Control Panel &Amplifiers. They shall be compatible with suppliedAmplifiers and shall work on 70.7Vrms |
| 102 | 2 C X 1.5 Sq mm multi stranded twisted unshielded FRLS Copper cable in existing Conduit. |
| 103 | UTP CAT6 patch cord 3 mtrs |
| 104 | PVC conduit pipe |
| 105 | Testing, Commissioing, training and Handover |
| 106 | PASSIVE DATA & IP VOICE COMPONENTS Supply and fixing of …mtrs cat 6 patch cable 2 mtr |
| 107 | VENTILATION EQUIPMENT Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class \"B\" insulation suitable for operating at 1phase, 230V, 50hz power supply.900 CFM / 25mm TSP WG for Toilet Exhaust. |
| 108 | AIR DISTRIBUTION PRODUCT (ADP) Supply, Installation, Testing & Commissioning of Galvanized-Class VIII with zinc coating of 120 gm / Sqmt surface area as per IS-277. With TDF/TDC Flange system with factory fabricated Box section with neoprene rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts.(The Minimum Duct Gauge should be of 24 Gauge only.)Duct construction and installation shall be in accordance with SMACNA codes and Standards and all ducts testing pressure should be 500 Pascal. (pa)All ducting shall be of factory fabricated completely finished and transported to site in a boxed form (including the duct flange and the VAV transition pieces, grille / slot / diffusers plenum boxes, Z pieces and etc..)The Duct shall be supported with GI steel Rods & MS angle Supports at regular minimum 2500mm intervals.Ducts should be factory fabricated & Transportation should be in box section only to site. in site the duct needs to be stored in proper manner & covered with polythene sheets to avoid dust accumulation.G.I. Sheet Make - Tata / Sail / Jindal / Vizag Steel.24 Gauge (0.63mm Thick - 0mm - 750mm) |
| 109 | Supply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc.,(Area calculation : (L x B)) |
| 110 | Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges.Note:a) Colour shall be as per the False ceiling or Architect intent. |
| 111 | Supply, Installation, Testing & Commissioning of Extruded Al. Powder coated Continuous grills for supply, return & exhasut air with extruded aluminum powder coated linear fixed bar grilles, horizontal fixed bars, slimline blade ( 3 mm nominal thickness ), grille height 16 mm ,blade pitch 12.5 mm and blade angle 0/15 Degree deflection without damper and with end flanges.Note:a) 15 Degree deflection for Supplay air.b) 0 Degree deflection for Return air & Exhaust air.c) Colour shall be as per the False ceiling or Architect intent. |
| 112 | P.H. Works:-INTERNAL PHE WORKS- Providing and fixing white vitreous china wall hung type water closet (European type) with seat and lid ,3/6 L, concelaed cistern, C.P. flush bend with fitting & C.I. brackets, 40mm flush bend ,Cistern frame , Wc connector etc.,design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required etc.,complete in all respected as directed by Engineer in Charge. Make:Jaquar ARS-WHT- 39953BIUFSM |
| 113 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.. Make: Jaquar WHT 15751P180UF |
| 114 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass single level mixer, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:. Make:Jaquar FLS-WHT-5701 |
| 115 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:. Make:Jaquar CNS-WHT-705 |
| 116 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete as directed by Engineer in Charge. Flexible pipe 40 mm dia |
| 117 | Providing & Fixing standard size Chromium Plated brassToilet paper holder fixed to woden plugs with Chromium Plated brass screws complete as per specification.Make:Jaquar ACN-CHR1151N |
| 118 | Providing and Fixing (a) Liquid Soap Container – Glass container or Plastic container with Chromium Plated brass lid and brackets fixed to wooden plugs with Chromium Plated brass screws or (b) Chromium Plated brass soap dish complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws or (c) white glazed tooth brush holder fixed to wooden plugs with Chromium Plated brass screws as per specification. as directed by Engineer in Charge.SOAP DISPENCER, PUSH-BUTTON TYPE, WHITE/SMOKEDMake: Jaquar SDR-WHTDJOOIOF |
| 119 | Providing and fixing jet spray consisting of jet spray, triangular spacer attached with toilet seat hinges, C.P. brass angle stop cock with PVC/C.P brass flexible pipe, wall flange complete as required etc complete and as directed by Engineer in Charge. HAND SHOWER (HEALTH FAUCET) with 8mm dia 1.2 METER LONG FLEXIBLE TUBE AND WALL HOOK.Make: Jaquar ALD-CHR-573 |
| 120 | Providing and fixing CPBottle Trap for Wash basin and sink as directed by Engineer in Charge. Bottle trap 32mm single piece moulded with height of 300 mm, effective length of tail pipe 190 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.Make: Jaquar ALD-CHR769L300X190 |
| 121 | Providing and fixing C.P. brass angle valve for basin mixerof approved quality conforming to IS:8931 and etc complete as directed by Engineer in Charge.Make: Jaquar OPP-CHR15053PM |
| 122 | Providing and fixing C.P. brass cast twin coat hooks fixed to wall/door with wooden cleats and S.S screws includingcutting holes in wallandmakinggood the wall wherever required etc complete and as directed by Engineer in Charge.Make: Jaquar ACN-CHR1161N |
| 123 | Supply, Collecting, Storing ,Shifting to place of water, testing & Commissioningof approved make with approved makeof Grab Bars for accessible toilets fixed to wall( Used for Handicapt Toilet only). Etc complete and as directed by Engineer in Charge.Make:Jaquar- AHS-CHR-1507 |
| 124 | Supply,Installation of Hand Drier, with nessary screws and nuts , The Works shall include cutting and makingfinish of walls etc complete. and as directed by Engineer in Charge.Make:Jaquar- EH26 Stainless Steel Hand Dryer |
| 125 | Supply,placing in positionsof SS waste Receptacle with swing type SS cover for all toilets ,and as directed by Engineer in Charge. |
| 126 | Supply,Installation of Tissue Paper dispenser, with nessary screws and nuts , The Works shall include cutting and makingfinish of walls etc complete. and as directed by Engineer in Charge. |
| 127 | INTERNAL DRAINAGE (SOIL,WASTE,RAIN WATER PIPES) Providing, fixing, testingand commissioningof UPVC SWR pipe type \"B\" conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, \"Y\", offset, cleaning pipe door, clamps etc. conforming to IS:14735-1999 and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type \"B\". The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint as required/applicable etc complete and as directed by Engineer in Charge. 75 mm (OD) |
| 128 | 110 mm (OD) |
| 129 | Providing, fixing, testing and commissioning ofUPVC cleanout plug conforming to IS : 14735-1999 complete with all fitting; accessories and civil work etc complete and as directed by Engineer in Charge. 110 mm OD |
| 130 | Providing, fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class III including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For fixtures waste) etc complete and as directed by Engineer in Charge.40mm (OD) |
| 131 | Providing and fixing straight/offset type flexible single body push fit type WC Pan Connector with factory supplied seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet) etc complete and as directed by Engineer in Charge. |
| 132 | Providing and fixing in position stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.00 mm thick top grating (Jali) with ring to be fixed inside C.I. or uPVC ‘P’ traps with cement concrete. etc complete and as directed by Engineer in Charge. |
| 133 | Providing & fixing 1 mm thick cast CP grating with rim of approved design including setting in floor with cement mortar. (For Floor Drain) etc complete and as directed by Engineer in Charge.125mm dia CP gratingh |
| 134 | Providing and fixing M.S structural work fabricated from standard sections e.g. M.S. rounds, angles, channels, plates including cutting to size, welding, drilling with concrete drilling bits and fixing dash fasteners in RCC structural members as directed by Engineer-in-charge including cutting and making good the walls, ceilings and floors (for all types of pipe supports, clamps, etc.) complete as directed by the Engineer in charge. |
| 135 | WATER SUPPLY INTERNAL Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 136 | 25 mm nominal outer dia Pipes |
| 137 | 32 mm nominal outer dia Pipes |
| 138 | Supplying all materials, labour, T&P and cutting holes through existing brick work including makinggood thedamagesincementmortar ( 1:4) for takingGI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 139 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/PVC pipes and making good the damages as per the direction of the Engineer in charge |
| 140 | Providing and fixing forged brass nickel plated lever operated ball valve of full flow with forged brass hard chrome plated ball with min. working pressure of 15 Kg/cm2.Lever should be anti rust coating, complete in all respects etc complete and as directed by Engineer in Charge. 20 mm dia |
| 141 | 25 mm dia |
| 142 | 32 mm dia |
| 143 | EXTERNAL PHE WORKS Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil(with excavated earth) Pipes, cables etc, not exceeding 80 mm dia. |
| 144 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for irrigation water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes |
| 145 | 25 mm dia |
| 146 | 50 mm dia |
| 147 | 65 mm dia |
| 148 | Providing,fixing , testing and commissioningwatermeterwith directreadingdial inKL with all necessary fitting such as threaded pieces, unionspressure gauge, isolation cock, flanges piece for future removal,flanges / unions completewithallnecessary testingcharges and obtainingtest certificates frommunicipal authorities, on following size pipe lines (1 no. strainershall be providedat inlet & outlet and cost shall be inclusive for the same).The meter shall comply to ISO 4064 standard, feasible for class B or Class A installation etc complete and as directed by Engineer in Charge.40 mm nominal bore |
| 149 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with SFRC medium duty cover 600 x 600and RCC top slab 1 :2:4 mix (1 cement :2 coarse sand: 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design etc complete and as directed by Engineer in Charge. |
| 150 | Making connection to existing water main by tapping to gunmetal ferrule of 50 mm dia including excavation, bailing out water and filling back the excavated of earth in all kind of soil , cutting & threading the pipe etc. getting approval from concerned authorities. |
| 151 | Providing and fixing forged brass nickel plated lever operated ball valve of full flow with forged brass hard chrome plated ball with min. working pressure of 15 Kg/cm2.Lever should be anti rust coating, complete in all respects etc complete and as directed by Engineer in Charge. 20 mm dia |
| 152 | 25 mm dia |
| 153 | 32 mm dia |
| 154 | Providing and fixing forged brass nickel plated lever operated butterfly valve of full flow with forged brass hard chrome plated ball with min. working pressure of 15 Kg/cm2.Lever should be anti rust coating, complete in all respects etc complete and as directed by Engineer in Charge. 50 mm dia |
| 155 | 65 mm dia |
| 156 | EXTERNAL SEWERAGE & DRAINAGE Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4984/2016 of the following outside dia for Pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 160mm dia u-pvc pipe alround concrete |
| 157 | 200mm dia u-pvc pipe alround concrete |
| 158 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 159 | Providing and laying non-pressure NP3 class (medium duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete and as directed by Engineer in Charge. 300 mm dia RCC pipe |
| 160 | 500 mm dia RCC pipe |
| 161 | 600 mm dia RCC pipe |
| 162 | 750 mm dia RCC pipe |
| 163 | Providing and laying cement concrete 1:4:8 (1 cement : 4 coarse sand : 18 graded stone aggregate 40 mm nominal size) up to haunches of R.C.C. pipes including bed concrete as per standard design : 300 mm dia RCC pipe |
| 164 | 500 mm dia RCC pipe |
| 165 | 600 mm dia RCC pipe |
| 166 | 750 mm dia RCC pipe |
| 167 | Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeInspection chamber Inside size 760mmx760mmx460mm |
| 168 | Supplying all materials, labour, T&P and constructing man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge a)Man hole chamber Inside size 910mmx910mmx910mm |
| 169 | b)Circular MH inside dia 900mmx1110mm with sides sloped upto560mm |
| 170 | c)Circular MH inside dia 1200mmx1670mm with sides sloped upto560mm |
| 171 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 ( 1cement : 3coarsesand :6 gradedstoneaggregate 20 mm nominal size) complete as per design etc complete and as directed by Engineer in Charge. |
| 172 | Supplying and fixing C.I. cover without frame for manholes etc complete and as directed by Engineer in Charge.560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg |
| 173 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg etc complete and as directed by Engineer in Charge. |
| 174 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 175 | Construction of catch basin for Surface drainage with 230mm thick walls in well burnt table moulded bricks in CM 1:4 over a bed of 100 mm thick PCC 1:4:8 internal walls plastered smooth in CM 1:3 and external walls plastered in1:6 with sponge finish. Providing and fixing FRP heavu duty grating of size as per drawing on top surface flushed to the finished floor level with necessary excavation, back filling the selected excavated earth with all leads and lifts etc., complete.a) 600mmx600mm upto 1200mm depth(clear internal dimension) - surface drainage |
| 176 | b) 800mmx800mm upto 2000mm depth(clear internal dimension) - surface drainage |
| 177 | 200 User Septic tank- Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge. |
| 178 | Additional Depth. |
| 179 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 180 | Supplying all materials, labour, T&P andproviding cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 181 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 182 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 183 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge RCC floor roof, chajja etc |
| 184 | RCC Beam, Column, wall etc |
| 185 | RCC Plinth bend/ Raft |
| 186 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 187 | Supplying all materials,labour,T&P and providing 6mm thick cement plaster(1:4) on RCCwork including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 188 | Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 189 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge |
| 190 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 191 | Supplying all materials, labour, T&P and fitting and fixing RCPC cover of heavy duty etc. allcomplete as per specification and direction of the Engineer in charge. |
| 192 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy