}

Provision Of Pr Equipment Storage Facility At New Mangalore - 1 Design, Manufacture And Erection Of Building In Peb Structure Of Size20.0 Mtrs X 19.00 Mtrsclearheight9.00 Mtrs With Steel Stanchions And Galvalume Sheet Roofing And Side Claddingon Both S, mangalore-Goa

Military Engineer Services-MES has published Provision Of Pr Equipment Storage Facility At New Mangalore - 1 Design, Manufacture And Erection Of Building In Peb Structure Of Size20.0 Mtrs X 19.00 Mtrsclearheight9.00 Mtrs With Steel Stanchions And Galvalume Sheet Roofing And Side Claddingon Both S. Submission Date for this Tender is 05-04-2022. Screws Tenders in mangalore Goa. Bidders can get complete Tender details and download the document.




Tender Notice

31029106
Corrigendum : Provision Of Pr Equipment Storage Facility At New Mangalore - 1 Design, Manufacture And Erection Of Building In Peb Structure Of Size20.0 Mtrs X 19.00 Mtrsclearheight9.00 Mtrs With Steel Stanchions And Galvalume Sheet Roofing And Side Claddingon Both S
Open Tender
Indian
Goa
mangalore
05-04-2022

Tender Details

Provision Of Pr Equipment Storage Facility At New Mangalore - 1 Design, Manufacture And Erection Of Building In Peb Structure Of Size20.0 Mtrs X 19.00 Mtrsclearheight9.00 Mtrs With Steel Stanchions And Galvalume Sheet Roofing And Side Claddingon Both Sides & Rear Side Of The Bldg And Frontsidefully Automated, Electrically Operated Sliding Door Of Size 19.00M X 9.0 M ( 06 Nos Equal Leaves, 03 Nos On Either Side ) Fabricated From Plate Or Bar Stock By Cold Forming Process Confirming To Physical Specifications For Built Up Sections Plates Ofastm A572 ( Grade 50 ) Or Hot Rolled Structural Sections Confirming To Astm A-36, Bracing Rods Confirming Toastm A-572 ( Grade 50 ) , Colled Formed Sectionsphysical Specifications Of Astm A 572 ( Grade 50 ) Withcomplete Epoxy Painting To All Primary Steel Memebers, Wall Cladding And Roofingwithprepainted Galavlume Sheeting 0.50Mm Thick Tct550 Mpa Confirming To Astm A 792 Gr 80, Sky Light With 1.5 Mm Thick Rigid Polycarbonate Sheet Profiled To Match The Roofing / Cladding Profile As Sky Light For Both Roof And Wall For 4% Of Roof Area , Max Ridge Heightshall Be Maintained As Per Slope 1:10 , Front Side Fully Automated Electrically Operated Door Of Size 19.0M X 9.0M Height ( Pre-Painted Galvalume Corrugated Sheet On Front Side Andprepainted Galvalume Plain On Back Side, Front Side 6 Leafs Fully Automated Electrically Operated Doors ( 6 Equal Doors Leafsbi-Parting 3 Leafseach Side Opening On Either Side ) , Turbo Ventilators 06Nos, 3.0 M Height Masonry Wall On 3 Sides , Pvc Bird Proofing With Mesh Of Size 30X30x4mm Thick Fixed Below The Purlin Using Aluminimum Angle Of Size 40X40x3mm Screwed @ 600Mm C / Cpile Foundation Including Pile Cap / Grade Beam In Rcc M-30 Design Mix Concrete , Flooring Shall Be Of 200Mm Thick Pqc With Hdpe Sheet, Sand Cushion, Dlc, Wmm And Gsb, Ramp Of Size 19.0Mx6.0Mcomplete All As Specified And Directed. 2 Design, Supply Installatin Of Complete Internal Electrification Scheme Including Artificial Lighting For Hangar As Per Is 732-2019, Iec 60335 And Nbc 2016. The Following Electric Points And Fixtures Shall Be Provided Inside The Hangar1. 3 Phase Industrial Socket 32 A - 04 Nos2. 1 Phase Industrial Socket 20 A - 02 Nos3. Power Point 16A / 5A-20 Nos4. Air Circulators Industrial Type Self Standing 450Mm Sweep - 10 Nos. ( I ) . Design Details Of Internal Electric Wiring Scheme Including Ldb, Electrical Points, Artificial Lighting Scheme Supported By Da Lux Analysis Has To Be To Be Prepaired By The Contractor And Getting It Approved. ( Ii ) Design Internal Artificial Lighting Of Work Shop With Suitable Energy Efficient Led Fittings Of Reputed Make Having Efficiency >100 / M / W To Ensure Unform Distribution Of Light With Minimum Lux Level 300-500-750 As Per Nbc-2016And Minimum Glare Level Index Should Be Less Than 2 To Enhance Visual Comfort. Led Light Fittings Has To Be Suitably Fitted On Walls / Ceiling Considering Safety And Ease Of Maintenance. Selection Of Led Light Fittings Shall Be As Per Nec / Relavent Is / Ecbc Norms. ( Iii ) Internal Electrification Scheme Including Artificial Lighting Has To Be Vetted By Nit / It / Government Engineering College And Got Approved By Accepting Officer Before Commencement Of Work 3 Lightning Protection: Supply & Fix Single Pointed Aluminium Rod, 12 Mm Dia, 300 Mm Long Fiixed On Roof Including All Fittings & Fixtures And Pcc 1:2:4 Type B1 Blocks Of Size 100Mm X 100Mm X 100Mmcomplete All As Specified And Directed 4 Supply & Fix Aluminium Strip 25 Mm X 3.15 Mm Fixed Over Procelin Insulators Of Suitable Size With Fixing Screws Etc For Fixing Strip On Roof And Down Conductors Above Ground Allcomplete As Specified And Directed. 5 M & L For Gi Earth Strip 32 X 6 Mm With Saddle And Fixing Screws Burried In Ground Etc From Test Terminal Block To Earth Pit Complete All As Specified And Directed 6 M & L For Test Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Of Size 75X75x25mm Drilled And Secured Including 4Nos 8Mm Dia 25Mm Long Hexagonal Head Brass Screw Including Box Of Size 90Mm X 90Mm X 90Mm Made Of 1.6Mm Plain Sheet Painted With Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Secured To Wall For Protection Of Test Point Complete All As Specified And Directed 7 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode Of 60 Cm X 60 Cm X 6 Mm Size, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level, Connected To Galvanised Steel Strip Of Size 32X6mm As Earth Lead, By Means Of Bolts, Buts, Check Nuts And Washers Of Galvanised Iron Or Steel, Galvanized Iron Pipe Of 40 Mm Diameter, Connected To Earthing Test Point, All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion And Including Excavation, Earthwork, Pcc Earth Pit Of Dimensions 550 Mm X 550 Mm ( Outer ) And 300 Mm X 300 Mm ( Inner ) And 250 Mm Deep, With A 10 Mm Thick Ci Cover, Hinged To Ci Frame On Ground Level, Gi Watering Pipe, Funnel, Etc. As All Specified And Directed. 8 Avaition Obstruction Light:Supply And Fixintegral Led Aviationlight Comprising Of Aluminium Alloy Housingwith Polycarbonate Housing And Accessories ( Make Bajaj Cat No. Bgav 302 Led 24V ) 9 S&F Metal Enclosure Timer Db Ip 54 Complete With Timer Switch, Power Contactor, Control Mcb Dp 16 A Etc Complete. Make : Indoasian Model / Abb / Havells 10 Supply, Laying, Jointing And Testing, Commissioning Xlpe Insulated, Screened Pvc Bedded, Galvanised Steel Strip / Wire Armoured Power Cable ( Heavy Duty ) With Standardaluminium Conductor Of Size 2 Core X 6.0 Sqmm On Poles / Walls As Cable For Avaition Obstruction Light Complete All As Specified And Directed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Mar-2022 82064AMDTSTODATE1 Date 19-03-2022
2 07-Mar-2022 82064AMDTTOTENDERPAGES1 BOQ 19-03-2022
3 17-Mar-2022 82064AMDTSTODATE2 Date 25-03-2022
4 24-Mar-2022 82064AMDTSTODATE3 Date 29-03-2022
5 24-Mar-2022 82064AMDTSTOTENDERPAGES2 Other 29-03-2022
6 29-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-04-2022

Key Value

Document Fees
INR 2000 /-
EMD
INR 365000.0 /-
Tender Value
INR 2.90 Crore /-

BOQ Items

Name of Work: PROVISION OF PR EQUIPMENT STORAGE FACILITY AT NEW MANGALORE
Sl. No. Item Description
1Design, manufacture and erection of building in PEB structure of size20.0 Mtrs X 19.00 mtrsClearheight9.00 mtrs with steel stanchions and Galvalume sheet roofing and side claddingon both sides & rear side of the bldg and frontsidefully automated, electrically operated sliding door of size 19.00m x 9.0 m ( 06 nos equal leaves, 03 nos on either side) fabricated from plate or bar stock by cold forming process confirming to physical specifications for Built up sections Plates ofASTM A572 (Grade 50) or hot rolled structural sections confirming to ASTM A-36, Bracing rods confirming toASTM A-572(Grade 50) , Colled formed sectionsphysical specifications of ASTM A 572 (Grade 50) withcomplete epoxy painting to all primary steel memebers, wall cladding and roofingwithprepainted galavlume sheeting 0.50mm thick TCT550 Mpa confirming to ASTM A 792 Gr 80, Sky light with 1.5 mm thick rigid polycarbonate sheet profiled to match the roofing/cladding profile as sky light for both roof and wall for 4% of roof area ,max ridge heightshall be maintained as per slope 1:10 , front side fully automated electrically operated door of size 19.0m x 9.0m height ( pre-painted galvalume corrugated sheet on front side andprepainted galvalume plain on back side,front side 6 leafs fully automated electrically operated doors( 6 equal doors leafsbi-parting 3 leafseach side opening on either side), turbo ventilators 06Nos,3.0 M height masonry wall on 3 sides , PVC bird proofing with mesh of size 30x30x4mm thick fixed below the purlin using aluminimum angle of size 40x40x3mm screwed @ 600mm C/cPile Foundation including Pile cap/ grade beam in RCC M-30 design mix concrete , Flooring shall be of 200mm thick PQC with HDPE sheet, sand cushion, DLC, WMM and GSB, Ramp of size 19.0mx6.0mcomplete all as specified and directed.
2Design, supply installatin of complete internal electrification scheme including artificial lighting for hangar as per IS 732-2019, IEC 60335 and NBC 2016. The following electric points and fixtures shall be provided inside the hangar 1. 3 Phase industrial socket 32 A - 04 Nos 2. 1 Phase industrial socket 20 A - 02 Nos 3. Power Point 16A/5A-20 Nos 4. Air Circulators Industrial type self standing 450mm sweep - 10 Nos. (i). Design details of internal electric wiring scheme including LDB, electrical points, artificial lighting scheme supported by DA Lux analysis has to be to be prepaired by the contractor and getting it approved. (ii) Design internal artificial lighting of work shop with suitable energy efficient LED fittings of reputed make having efficiency >100/m/w to ensure unform distribution of light with minimum lux level 300-500-750 as per NBC-2016and minimum glare level index should be less than 2 to enhance visual comfort. LED light fittings has to be suitably fitted on walls/ceiling considering safety and ease of maintenance. Selection of LED light fittings shall be as per NEC / relavent IS / ECBC norms.(iii) Internal electrification scheme including artificial lighting has to be vetted by NIT/IT/Government Engineering College and got approved by accepting officer before commencement of work
3LIGHTNING PROTECTION: Supply & fix single pointed aluminium rod, 12 mm dia, 300 mm long Fiixed on roof including all fittings & fixtures and PCC 1:2:4 Type B1 blocks of size 100mm X 100mm X 100mmcomplete all as specified and directed
4Supply & fix aluminium strip 25 mm x 3.15 mm fixed over procelin insulators of suitable size with fixing screws etc for fixing strip on roof and down conductors above ground allcomplete as specified and directed.
5M & L for GI earth strip 32 X 6 mm with saddle and fixing screws burried in ground etc from test terminal block to earth pit complete all as specified and directed
6M & L for test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and secured including 4Nos 8mm dia 25mm long hexagonal head brass screw including box of size 90mm x 90mm x 90mm made of 1.6mm plain sheet painted with two coat of synthetic enamel paint over a coat of red oxide primer and secured to wall for protection of test point complete all as specified and directed
7M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel strip of size 32x6mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.
8AVAITION OBSTRUCTION LIGHT:Supply and fixintegral LED aviationlight comprising of aluminium alloy housingwith polycarbonate housing and accessories(Make Bajaj Cat No. BGAV 302 LED 24V)
9S&F metal enclosure timer DB IP 54 complete with Timer switch, Power contactor, Control MCB DP 16 A etc complete. Make : Indoasian Model / ABB/ Havells
10Supply, laying, Jointing and testing, commissioning XLPE insulated, screened PVC bedded, galvanised steel strip/ wire armoured power cable (Heavy duty) with standardaluminium conductor of size 2 core x 6.0 sqmm on poles/ walls as cable for avaition obstruction light complete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail