|
| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil including mixed soil but excluding laterite or sandstone) including removing, reading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation |
| 3 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 4 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand |
| 5 | Anti termite treatment to the top surface of theconsolidated earth within plinth walls with chemicalemulsion by admixing chloropyrofos emulsifiableconcentrates (1% concentration) with water by weightat the rate of 5 Litres per sq. m. of the surface beforesand bed or sub-grade is laid. Holes upto 50 mm. to75 mm. deep at 150 mm. centre to centre both waysshall be made with 12 mm, diameter mild steel rod onthe surface to facilitate saturation of the soil with thechemical emulsion. The work shall be carried out asper specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will beper Sq.m of plan area of plinth treated.) |
| 6 | Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(a) 1:3:6 proportion pakur variety |
| 7 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and directioni.Tor Steel, JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttring or 9 to 12 mm thick approved quality ply board shuttring in any concrete work. Up to bottom of slab. |
| 10 | Brick work with 1st class bricks in cement mortar (1:4)including curing etc complete(a) In foundation and plinth |
| 11 | Brick work with 1st class bricks in cement mortar (1:6)including curing etc complete(a) In super structure , ground floor. |
| 12 | M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing above 16 Kg./sq.mtr and above |
| 13 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making goodamages complete. |
| 14 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.In Ground floor Flash butt welded windows and ventilators Without integrated grills.Fixed type steel windows as per IS sizes with horizontal glazing bars. |
| 15 | M.S. structural works in roof trusses with tubular sectionsconforming to IS: 806-1968 & IS: 1161- 1998 cnnected to oneanother with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m |
| 16 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by colourcoated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:-a) With 0.5 mm thick sheet |
| 17 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement |
| 18 | Labour for Chipping of concrete surface before taking upPlastering work. |
| 19 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) 20mm thick plaster. a) With proportion (1:6) cemenet mortar. |
| 20 | (ii) 15mm thick plaster. b) With proportion (1:6) cemenet mortar. |
| 21 | (iii) With 1:4 cement mortar, c)10mm thick plaster. |
| 22 | Neat cement punning about 1.5mm thick in wall dado window sill etc. [Note: cement 0.152 cum per 100 sqm] |
| 23 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor) (b) TwoCoat i) Water based interior grade Acrylic Primer |
| 24 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 25 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer. In Ground floor (Two Coat) c) Premium100% Acrylic Emulsion. |
| 26 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 27 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary(a) On steel or other metal surface(iv) Two coats (with any shade except white) |
| 28 | Sub Total |
| 29 | GST 12% |
| 30 | CESS 1% |