Special Repair To Mes Key Personnel Accomodation Bldg No 451 At Ins Hansa And Special Repair To Adr Ac Plant Bldg No 91 1 At Ins Hansa Under Age Br I And Age Em I Of Ge Nw Vasco 8420 / 21 / E8, vasco-Goa

Military Engineer Services-MES has published Special Repair To Mes Key Personnel Accomodation Bldg No 451 At Ins Hansa And Special Repair To Adr Ac Plant Bldg No 91 1 At Ins Hansa Under Age Br I And Age Em I Of Ge Nw Vasco 8420 / 21 / E8. Submission Date for this Tender is 16-02-2022. HVAC Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30775625
Corrigendum : Special Repair To Mes Key Personnel Accomodation Bldg No 451 At Ins Hansa And Special Repair To Adr Ac Plant Bldg No 91 1 At Ins Hansa Under Age Br I And Age Em I Of Ge Nw Vasco 8420 / 21 / E8
Open Tender
Indian
Goa
vasco
16-02-2022

Tender Details

Special Repair To Mes Key Personnel Accomodation Bldg No 451 At Ins Hansa And Special Repair To Adr Ac Plant Bldg No 91 1 At Ins Hansa Under Age Br I And Age Em I Of Ge Nw Vasco 8420 / 21 / E8

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Feb-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 89400.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

NAME OF WORK : SPECIALREPAIR TO MES KEY PERSONNEL ACCOMODATION (BLDG NO 451) AT INS HANSA AND SPECIAL REPAIR TO ADR AC PLANT (BLDG NO 91/1) AT INS HANSA UNDER AGE B/R-I AND AGE E/M-I OF GE (NW) VASCO.
Sl. No. Item Description
1M&L for gunniting exposed concrete surfaces with one layer of compast spray set modified concrete 20mm avg thickness in proportion (50Kg cement 3 to 6mm granite chips 100 kg, zonal sand 50 kg and complast 3 to 2.5% by weight of cement & 12.5 to 16.5 ltrs of water mixed with admixture incl bonding agent after applying Dr Fixit Rust remover or equivalent chemical as approvedto old rusted reinforcement after necessary preparation of surfaces by brush application and gunniting with pressure nozzle with a delivery capacity of 2.5 Kg/sqm and removing the debris n exc 250 mtr and depositing complete all as specified and directed by Engr-in-charge to following locations:-
2(a) 40 mm thick in columns
3(b) 30 mm thick in beams
4(c) 20 mm thick in slabs
5S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dianot exc. 4 Kg/sqm.
6Bonding the entire exposed surface with one coat of fosroc Nitop bond SBR as per manufacturer instructions over whire fabric and surfaces of concrete structure
7Replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB complete all as specified and directed by Engr-in-Charge.
8Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and leveled as directed by Engr-in -charge.
9Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over rooftop surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid separately.
10M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab.Fillingthe cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1stPriming coat (Dr. Fixit primeseal ,Sika coolcoat primer or eq) on prepared concrete/ plastered surfaceof Primeseal or Sika coolcoat primer without any dilution at the rate of 200-300 Gms per Sqm and allow to dry for 04 hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat/ Sika coolcoat of SIka Products) without any dilution at the rate of 2 Sqm per ltr over the primed surface.On the wet surface of 1st coat overlay a woven fibre glass mesh, min 50GSM of size 2.5mm x 2.5mm and allow it to soak completely. Apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat once the second coat is dry. Drying time between coats will be 6 to 8 hrs all as directed. Note : Work should be executed by authorised applicator of Approved Manufacturer.
11Taking down cement plaster on brick or stone walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water, etc.
12M&L for rendering 15 mm thick on block masonry surfaces or other than fair faces of brick work in cement mortar 1:4. finished to even and smooth(without using extra cement)
13M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coatsfirst coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
14M&L Rendering 5 mm thick cement plaster on ceiling in CM 1:3 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
15Supply only water proofing compound
16M&L Preparing new plastered ceiling surfaces and applying twocoat ofoil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling.
17M&L Preparing new plastered wall surfaces and applying twocoat ofoil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall
18M&L preparation of new surface of wall and applying two coats of water proofing treatment by using araldite builder barrier coat or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed by Engr-in-Charge all as specified in manufacturer"s instructions and to be applied through applicator of authorised manufacturer with5 Years guarantee.
19Dismantling floor/wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises
20Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.
21M&Lscreed bed or bedding layer of mortar 15 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles.
22M/L Rendering 10mm thick in 1:6 CM on fair faces of block work or concrete surfaces to receive glazed tiles
23M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick, joint free (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
24M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick, joint free (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
25Glazed coloured ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match
26Taking down chowkat or frames n exc 1.5 sqm each (w/o taking of shutters from the frame and removing to store)
27Taking down chowkat or framesexc 1.5 sqm but n. exc 4 sqm each (w/o taking of shutters from the frame and removing to store)
28Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam colour PVC sheet on back face, including PVC lining around all 4 edges of shutter,supplying & fixing in frame at site as per specification & drawing all as specified and directed.
29Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling will be of wire gauze wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly, supplying & fixing in the frame at site as per specification & drawing.
30S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame, single rebate of size 75mm x 50mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and directed.
31S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame, double rebate of size 125mm x 65mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and directed.
32S&F butt hinges medium weight stainless steel 100mm size
33Extruded aluminium alloy handles, fabricated type, anodised 100 mm grip size .
34Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm size
35Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
36S&F powder coated aluminium door and window shutter and frame any type (sliding or openable) and other similar work etc 60 micron powder coated section, fabricated by using the JINDAL / INDAL / HINDAL CO / CENTURIAN sections including all necessary roller wheels for window, cleats , handle, door stopper locking arrangement and arrangements to receivedglass/ prelaminated particle board with aluminium beading and stainless steel screw incl cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound. (The weight of rubber gasket beading will not be measured with the weight of aluminium shutters, glass and prelaminated particle board will be measured and paid separately) All sections as approved by GE.
37S&FPowder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of "F" section of size 23.4x15.3x1.4 mm thick all as per manufacturer"s instructions complete all as specified and directed
38S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane
39S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane
40Solar control film 50 micron reflective type mirror finish/mirror jet black type(gareware sun control or equivalent)
41S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples
42S & F of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm
43Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
44Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm.
45S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm
46S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
47S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
48S & F 75 mm bore PVC (SWR) bends of any radius fitted with oval access door complete all as specified and directed.
49S & F in repairs 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
50S & F 110 mm bore PVC (SWR) bends of any radius.
51Supply & Fixed600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers
52S&F in repair Stop valves fancy type, chromium plated 15 mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
53S&F wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings
54S&F in repairs chromium plated fancy type Bib taps 15 mm dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
55S&F Pillar taps fancy type of 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
56Supply & Fixed Chromium plated shower roses 125 mm size with or without swivel joints, including fixing to steel pipe or union
57M&L Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75 mm dia
58S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe)
59Supply & Fixed PVC valveless, syphonic action type, flushing cistern, low level, coloured, with inlet , ball valve, float and handle including brackets & outlet flushing pipe, of capacity 10 ltrs.
60S&F in repairs Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges.
61S&F in repairs Soap dish, of material brass with glossy finish, Cat No. BA-45 of Prayag or equivalent.
62S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen oraboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm
63M&L Dismantling water tanks of 1000 ltrs capacity and removing to store
64M&L Dismantling water tanks of 500 ltrs capacity and removing to store
65S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position all as specified in SSR Part I .
66S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity hoisted and fixed in position all as specified in SSR Part I .
67Dismantling plain or corrugated AC sheeting any gauge, thickness in roof coverings
68S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified
69Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ disintegrated soil and removing surplus soil to a distance n.exc 50m & making good surface
70Plain Cement Concrete Type C2 1:3:6 (using 40 mm gradedstone aggregate) in foundations, filling and mass concrete.
71M&L Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
72S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe 410-Wincluding cleats, distance pieces etc
73Preparation of new steel surfaces and applying two coats of epoxy anti corrossive paint over a coat of zinc primer
74S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.
75Dismantling boarding, any description, fixed in any position with Screws
76S/F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitably fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications.
77S&F stainless steel railing of height 0.9m and grade SS T-316 including all accessories with horizontal support of stainless steel and fitting to staircase, varandah, balconies etc all as per manufacturersinstruction and as directed by Engineer in Charge
78Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.
79M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
80M&L Machine cut kota stone in skirtings/dados/steps risers 20-25mm thick jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
81M&Lscreed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles.
82M&L Granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
83Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
84M & L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) in sub base of internal flooring/plinth protections, etc.
85M & L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors
86M & L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors
87S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
88Demolition of reinforced cement concrete as in roofslab (other than ground floor) beams, columns, chajjas and similar suspended work.
89Separating, scraping and cleaning of reinforcement obtained from item No 1
90Demolitionof Brick/ stone masonry bult in cement mortar.
91Pre - cast cement concrete 1:3:6 type C-1, (20mm graded stone aggregate) block masonarywith solid blocks built in cement mortar 1:6
92Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets.
93S&F Anodised aluminium snap grid frame work of Size of grid 605 x 605mm for false ceiling all as specified and directed by Engr-in-charge.
94S&F 10 mm thick PVC insulation panels with EPS stuck to 1mm PLAIN PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. As per specification and drawing
95M&L RCC Type B1 1:2:4, 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
96M&L Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
97Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
98M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wiredrawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium gradewith all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light/fan /exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
99All as per item No 2 here in before, butfor one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
100All as per item No 2 here in before, but for two way controlled by one , 5 Amp Switch one way completeall as specified and as directed
101All as per item No 2 here in before, but for one bell point controlled by one bell pushcomplete all as specified and as directed
102All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp Switch socket out leton the independent board complete all as specified and as directed
103All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp Switch socket out leton the same board complete all as specified and as directed
104M & L for surfacepoint wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wiredrawn in and including PVC conduit medium grade of as required size(not less than 20 mm in width) ISI marked medium duty,with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
105Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
106M & L for sub main wiring with two runs of single core 4.00 Sqmm FRLSCopper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC casing capingof as required size(not less than 20 mm in width)with all accessories such as Tees, elbows,junction boxes etc, as required fixed in wall along with onerun of 4.00 Sqmm single core FRLSinsulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, One run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
107M & L for sub main wiring with two runs of single core 6.00 Sqmm FRLSCopper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC casing capingof as required size(not less than 20 mm in width)with all accessories such as Tees, elbows,junction boxes etc, as required fixed in wall along with onerun of 4.00 Sqmm single core FRLSinsulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, One run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
108S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
109S & F in repairs modular bell push , flush type , 6 amps complete all asspecified and directed.
110S & F in repairs modular Switch single pole two way 6 A, 240 V complete all as specified and as directed
111S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
112S & F in repairs modular Socket outlet 2 in 1 , 6 Amps, 240 V complete all as specified and as directed
113S & F in repairs modular Socket outlet 2 in 1 , 6/16 Amps, 240 V complete all as specified and as directed
114S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 voltscomplete all as specified and as directed
115S & F in repairscall bell AC 230 volts single pole ding dong sound type.
116S & F in repairs Modular Fan step regulator, 120W - 2 moduleall as directed.
117Taking down unserviceable any type of Main Switch, DB"s including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
118S&F in repairs MCB DB TPN 4 way DB 415 V with 200 A rated bus bar double door type complete all as specified and as directed.
119S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
120S & F in repairs MCB TPN40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
121S & F in repairsMCB SPN06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
122S & F in repairsMCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
123M & L for Earthing complete with Galvanised earth plate electrode 600x 600x6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I incl necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks incl testing any type complete all as specified and as directed .
124Taking down carefully ceiling fans of size 1200/1400 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs incl servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of accessories such as ball bearings, gun metal bushes, capacitor, canopy top& bottom, shackle clip assembly and assembling of all parts and painting with two coat of synthetic enamel paintby using electric spray machine similar to match with existing colour, incl hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance after renovation of bldg complete all as specified and directed. (Note:- After taking down fan will be in contractor costudy to keep in safe condition.)
125Taking down old exhaust fan from its position and keeping aside in safe custody and refixing in serviceable condition after renovatio of bldg work completed all as specified and directed by engr-in-charge .
126Material and Labour for rewinding of ceiling fan motor of 1200 / 1400 mm sweep with new super enamelled copper winding wire of existing gauge and number of turns and applying insulated varnish and including removing burnt out copper winding wire complete all as specified and directed.
127All as per item no 29 here in before but of exhaust fan 300 / 380 mm sweep complete all as specified and directed.
128S & F in repairs Energy efficient surface Mounted LED Batten Luminire 20 watts 4" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed.
129S & F in repairs receses/ Surface mounting lights 2"x2" LED flat panel 36/40 Watt, white powder coated CRCA housing with highpower LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable item complete all as specified and directed.Make:- Bajaj Cat No - BZSSLL 36W NW or equivalent in Philips/CG
130S & F in repairs Energy efficient surface Mounted LED batten Luminire 10 watts 2" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.
131Supply and fixin repairs LED mirror light fitting1 x 10 Watts WW, operating voltage 140 V to 265 Vindoor decorative aluminum die cast, IP 42, complete with all accessories internally pre- wired and includingconnecting up with twin core twisted flexible copper conductorcable with suitable sizescomplete all as specifiedanddirected by Engr-in-Charge.
132Supply and fixin repairs LED mirror light fitting1 x 12 Watts WW, operating voltage 140 V to 265 Vindoor decorative aluminum die cast, IP 42, complete with all accessories internally pre- wired and includingconnecting up with twin core twisted flexible copper conductorcable with suitable sizescomplete all as specifiedanddirected by Engr-in-Charge.Make:-Lukar CP No LMJL12/Bajaj/Philips
133Supply and fix in repairs Lamp Holder , PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed by Engr-in charge.
134Supply and fix in repairs LED bulb 12 watts operating voltage 140 volts- 265 volts , 50 Hz all as specified and directed by Engr-in charge.
135Supply and fix in repairs Building SecurityLEDfitting 72 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED"s and electronic driver, internally prewiredincluding necessary fixing arrangement on Building by providingMS angle iron bracketof adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed.Make:-Bajaj cat part No. ENXT P 72L WH CR PC SD or equivalent
136Supply and fix in repairsGI bracket pipe of size 32/40 mm dia medium gradebent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any typeand the GI bracket pipe shall be fixed on wall/polesurfaces by providing suitable MS flat iron 32x6 mm clamps 2 nos of 25 cm long duly to the bracket pipe and painting to MS clampsand fixing with necessary suitablenuts,bolts & washers and removing of old unserviceable item complete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail