| 1 | BUILDING WORKS |
| 2 | Demolition of cement concrete (un-reinforced) of any description and in any position such as in bed for drain pipe etc complete all as specified and directed. |
| 3 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 4 | Demolition of cement concrete (reinforced), of any description and in any position not otherwise specifically provided for, reinforcement cut as required to facilitate demolition, complete all as specified and directed. |
| 5 | M & L for pre-cast cement concrete blcok masony with solid blocks of precast cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate), exc 10cm in width and set in cement mortar 1:6 complete all as specified and directed. |
| 6 | Taking down cement or cement lime plaster, any description on stone/ PCC block/ brick wall or top of chajja including raking out joints, hacking for key, scrubbing down with water etc and removal of debris to outside of INS Mandovi area including filling of open joints in cement mortar 1:6 complete all as specified and directed. |
| 7 | M & L for rendering 15 mm thick in two layers in cement mortar 1:3, 10 mm thick first layer and 5 mm thick outer layer mixed with WPC as per manufacturer\"s instructions on fair faces of brickwork or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.Note: Quoted rate shall be deemed to be inclusive of rate of WPC. |
| 8 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed. |
| 9 | M & L for preparation of newly plastered wall surfaces, priming with alkali resistant priming paint, applying 1 mm thick wall care putty wherever required and distempering with two coats of distemper oil emulsion, white or tinted, complete all as specified and directed. |
| 10 | M & L for preperation of newly plastered wall surfaces, ceiling cornices etc, making surface smooth by applying ready mix putty where ever required and applying two coats of acrylic emulsion exterior paint of approved shade, over a coat of primer, including necessary scaffolding complete all as specified and directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 12 | S & F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed. |
| 13 | S & F aluminum powder coated window/ ventilator shutter including frame, any type (sliding or open-able) and other similar work etc, fabricated, by using sections, including necessary arrangement to receive 4mm thick sheet glass or wire mesh with aluminium channel beading, stainless steel screws, rollers, maruti lock including the cost of rubber gasket / rubber beading, rollers, maruti lock etc, fixing frames complete all as specified and directed.Note: Weight of rubber gasket / beading rollers, maruti lock will not be measured with weight of aluminium shutter. Note: Sheet glass & wire mesh shall be measured and paid separately. |
| 14 | S & F powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including standard aluminium frame of \"F\" section of size 23.4 x 15.3 x 1.4 mm thick all as per manufacturer\"s instructions complete all as specified and directed. |
| 15 | S & F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified and directed. |
| 16 | S & F 4 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 17 | Making good under cills or over arches, lintels and bressummers, in cement mortar 1:4, including all pinning when necessary complete all as specified and directed. |
| 18 | S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 19 | M & L for 12 mm thick seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seamless finish complete all as specified and directed.Note: Frame work for ceiling shall be measured and paid separately under relevant item of this Schedule. |
| 20 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out in soft/ disintegrated rock, returning, filling in ramming earth or broken rubble mixed with earth around in layers n. exc 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 21 | M & L for cement concrete 1:3:6 type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 22 | S & F rolled mild steel Fe-290 (Gde E-165) in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. |
| 23 | S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 24 | S & F pre-painted galvalume aluminum zinc coating GI based plain steel sheet, 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 25 | S & F rolled mild steel Fe-290 (Gde E-165) plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed. |
| 26 | M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 27 | M & L for complete removal of existing treatment including preperation of old lastered wall surfaces preparatory to distempering, applying 1 mm thick acrylic wall care putty, priming the surface with alkali resistant priming paint and distempering with two coats of distemper oil emulsion, white or tinted complete all as specified and directed. |
| 28 | M & L for complete removal of any existing treatment on wall surfaces, ceiling cornices etc by brooming, scrapping down dust particle, smoke soot, moulds, moss and efforescent salts etc, making surface smooth by applying 2 mm thick acrylic wall care putty where ever required and applying two coats of acrylic emulsion exterior paint over a coat of primer, inclding necessary scaffolding complete all as specified and directed. |
| 29 | Taking down chowkats or frames not exceeding 1.5 sqm each, with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 30 | Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4.0 sqm each, with shutters (without taking off shutters from the frames) complete all as specified and directed.. |
| 31 | S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 32 | S & F 2nd class hard wood plain, framed, panelled shutters (any number ofpanels), 40mm thick, with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: fitted to chowkats complete all as specified and directed. |
| 33 | S & F extruded aluminium alloy handles, 100 mm long, fabricated type, anodised complete all as specified and directed. |
| 34 | S & F aluminium anodised, barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed. |
| 35 | S & F aluminium alloy, anodised, sliding door bolt of 300 mm size, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 36 | S & F butt hinges, 100 mm size, powder coated, medium weight, cold rolled mild steel complete all as specified and directed. |
| 37 | M & L for preparing new wooden surfaces of any description exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 38 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 39 | M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 40 | INTERNAL ELECTRIFICATION |
| 41 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed. |
| 42 | Taking down DB, main switch, sheet metal enclosure etc complete all as specified and directed. |
| 43 | Taking down submain wiring complete all as specified and directed. |
| 44 | M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for othe following complete all as specified and directed.Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc. |
| 45 | One light point controlled by one switch |
| 46 | One fan/ exhaust point controlled by one switch |
| 47 | Socket outlet 5 Amp on same board with other switches |
| 48 | Socket outlet 5 Amp on independent board |
| 49 | M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 3 pin 15 Amps switch socket combination on independent complete all as specified and directed.Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc. |
| 50 | S & F in repairs switch piano, 5 amp, single pole, one way, flush type, complete all as specified and directed. |
| 51 | S & F in repairs switch socket combination 5 pin and 5 Amps 230 volt 50 HZ AC, flush type complete all as specified and directed. |
| 52 | S & F in repairs switch socket combination 5 pin and 15 Amps 230 volt 50 HZ AC, flush type complete all as specified and directed. |
| 53 | S & F in repairs LED tube light fitting 1 X 20 watt, 220V AC decorative box type with driver and holder, including LED tube light, connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC blockwith steel screw complete all as specified and directed. |
| 54 | S & F in repairs LED building light fitting, 45 watts for 230 V 50HZ, suitable for operation over voltage range of 160 V to 260 V duly housed in pressure die cast aluminium housing comprising of LED lamp with individual optical lens, electronic driver with surge protection and PF more than 0.90 confirming to IP 66, cool day light output and connecting with existing feeder/ ceiling rose including provn of 1.5 sqmm 3 core copper multistranded conductor cable through and including suitable GI bracket with suitable size clamps with bolts, nuts and washers complete all as specified and directed.Make : Bajaj Model No. BRTFG 45W LED or equivalent as specified in List of Manufacturers |
| 55 | M & L for taking down and refixing ceiling fan after replacement of capacitor, rubber bush, fixing clamp and painting with white colour synthetic enamel paint complete all as specified and directed. |
| 56 | S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, \"C\" series, complete all as specified and directed. |
| 57 | S & F in repairs ceiling rose, 2 to 3 terminal, surface bakelite, 65X50 mm, complete all as specified and directed. |
| 58 | S & F in repairs MCB\"s (D.B), double door, SPN 8 way, 230 Volts, complete all as specified and directed. |
| 59 | S & F in repairs MCB\"s (D.B), vertical type, double door, TPN 4 way, 415 Volts, complete all as specified and directed. |
| 60 | S & F in repairs MCB SPN 32 Amps, 230 Volts, \"C\" series, complete all as specified and directed. |
| 61 | S & F in repairs MCB TPN, 63 Amps, 415 Volts, \"C\" series complete all as specified and directed. |
| 62 | S & F exhaust fan, 300 mm sweep single phase 230/240 volt AC supply 50 HZ, PVC body with louvers, with suitable MS Bracket, nuts, bolts and fixing arrangement, including resizing holes andPCC work as per site requirement and taking down old unsv exhaust fan and depositing to MES store yard complete all as specified and directed.Make :- Bajaj Maxima 300mm or equivalent as specified in List of Manufacturers |
| 63 | M & L for submain wiring with 4 runs of 16 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 16 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/ 32 mm dia PVC conduit concealed in wall with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: 4 runs of 16 Sqmm cable, one run of 16 Sqmm earth wire and one run of PVC conduit shall be measured as unit run. |
| 64 | M & L for submain wiring with 2 runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including PVC conduit of suitable size concealed in wall with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: 2 runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit run. |
| 65 | S & F sheet metal enclosure earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed. |
| 66 | M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC chamber in PCC 1:3:6 type C2, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing point and taking out unservicable earthing complete all as specified and directed.Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost. |
| 67 | EXTERNAL ELECTRIFICATION |
| 68 | Supplying, laying, jointing, testing and commissioning of LT XLPE insulated, armoured, heavy duty electric cables with multistranded aluminium conductor of 3.5 core, 50 Sqmm, shielded core type wrapped with tape screwed galvanized strip, suitable for earthed system for 1100V, AC 50 cycle including centre glands, lugs, jointing materials etc and taking out old unsv cables complete all as specified and directed.Note: Excavation, PCC, covers and protection shall be measured and paid separately under relevant items of this schedule. |
| 69 | Excavating in trenches, not exceeding 1.5 m wide andn exc 1.5 m in depth and getting out in soft disintegrated rock complete all as specified and directed. |
| 70 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using excavated soft disintegrated rock complete all as specified and directed. |
| 71 | Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 72 | Supply and laying fine dry river sand for cable protection in trenches for cable protection complete all as specified and directed.Note : Punned thickness only will be measured & paid.. |
| 73 | Supplying and laying un-reinforced precast concrete cable cover for cable protection, class LV, type I, flat, size 250mm x 150mm x 40mm, ISI marked complete all as specified and directed. |
| 74 | Supply and laying 80mm dia bore light grade GI tubing in trenches for cable protection complete all as specified and directed. |
| 75 | S & F SMC DB having connector terminal suitable for connecting cable upto 70 sqmm 4 core alongwith necessary glands, lugs and complete arrangement for fixing on existing pole/wall with suitable clamps, nut & bolt along with cable connections complete all as specified and directed. |