Bids Are Invited For 1 - Supply & Replacement Of 33Kv Oil Immersed Outdoor Type Ct Dual Core Dual Ratio 300-150/1-1A Core -1 Class 1 & Core 2 Class 5P10. The Job Incldes The Dismantling Of Existing Ct & Installation Of New Ct With All Connection Temination Etc. Complete In All Respect , 2 - Supply & Replacement Of 33Kv Oil Immersed Outdoor Type Ct Dual Core Dual Ratio 150-75/1-1A Core -1 Class 1 & Core 2 Class 5P10. The Job Incldes The Dismantling Of Existing Ct & Installation Of New Ct With All Connection Temination Etc. Complete Is All Respect , 3 - Shifting Of C&R Panel From Existing Place To Other Place Including Dismantling Of Same And Opening Of All Existing Connections & Shifting Of C&R To Other Place & Installation & Termination Of All Cables Etc At New Location , 4 - Supply & Laying Of Control Cable From Ct To C&R Panel Installed At New Location 6 Core 2.5 Sqmm Copper Armoured Cable , 5 - Supply & Laying Of Control Cable From Pt To C&R Panel Installed At New Location 6 Core 2.5 Sqmm Copper Armoured Cable , 6 - Supply & Laying Of Control Cable From 33Kv Vcb To C&R Panel (A.C. Supply) Installed At New Location4 Core 2.5 Sqmm Copper Armoured Cable , 7 - Supply & Laying Of Control Cable From 33Kv Vcb To C&R Panel (Dc Supply) Installed At New Location 2 Core 2.5 Sqmm Copper Armoured Cable , 8 - Supply & Laying Of Control Cable From 33Kv Vcb To C&R Panel (Control Connetctions) Installed At New Location12 Core 2.5 Sqmm Copper Armoured Cable , 9 - Supply And Laying Of 3 Core 70Sqmm Standered Aluminium Conductor Xlpe (Cross Linked Polyethylene) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S.7098 (Part-Ii With Latest Amendments) Iikv Grade. The Armouring Of Cable Shall Be Properly Connected With Earth Conductor By Clamps Etc. , 10 - Horizontal Direction Drill At 1Mtr , 11 - Supply & Laying Of Dwc Pipe Dia 100Mm With All Socket Etc. Complete In All Respect , 12 - Cable Jointing Of 11 Kv Grade 3 Core 70Sqmm Xlpe Insulated Armoured Cable With Suitable Cable Termination Using Raychem/Birla 3M/Mecp Kits Including All Accessories I.E. Sockets, Lugs, Gland Etc As Required But Without Cable Box. , 13 - Supply & Fixing Of Transformer Protection Relays (Oti, Wti & Wti). The Relays Shall Be Manual Reset Type With Hr Flag Control Supply Voltage Shall Be As Per Site Requirement. The Job Includes The Making Necessary Cutout In Existing Panel And Fixing Of Relays Along With All Required Wiring Testing Etc. Complete In All Respect , 14 - Supply & Burying Of Safe Earthing Electrode T-39 Zn. Zinc Coated, Length 3000Mm, Outer Pipe 76.3Mm X 3.2Mm Inner Pipe 42.4Mm X 2.6Mm, Terminal Dia 12Mm, Coating 80-100Micron Filled With Crysteline Conductive Mixture (Ccm) Havinbg Anti Corrosive & Conductive Properly With 50Kg Activated Soil (Bfc) Capable Of Reducing The Soil Restivity With Good Mixture Of Retaining Capacity And One Earthing Lead Of 20 X 3 G.I. Strip Upto Switch Board With 30Cm Square C.I. Frame With Hinged Cover & Masonary Housing. , 15 - Supply And Burring Of Safe Earthing Electrode T-39 Cu Copper Coated, Length Up To 3000Mm, Outer Pipe 76.3Mm X 3.2 Inner Pipe 42.4Mm X 2.6Mm, Terminal Dia 12Mm, Coating 80-100 Micron Filled With Crystalline Conductive Mixture (Ccm) Having Anti Corrosive & Conductive Property With 50 Kgs Activated Soil (Bfc) Capable Of Reducing The Soil Resistivity With Good Mixtureof Retaining Capacity Along With 30 Cm Square C.I. Frame With Hinged Cover & Masonry Housing. , 16 - Supply & Laying Of 32 X6 Mm G.I. Strip From Earth Electrode Directly In Ground As Required Complete In All Respect. , 17 - Supply & Laying Of 50 X6 Mm Copper Strip From Earth Electrode Directly In Ground As Required Complete In All Respect. , 18 - Supply,Instattion,Testing And Commissioning Of Ese Lightning Protection The Works Includes With Lightningprotection System,Lighning Counter,Earth Electode,Earth Enhancing Compound,Hdpe Chamber,Busbar Ms Mast And Earth Strip Complete In All Respect. , 19 - Supply And Laying Of 1800Mm X 900Mm X 12Mm Thick Chequered Rubbbber Matting Of Tested Quality. , 20 - Supply, Installation, Testing And Commissioning Of 5Mva Onan Transformer 33 Kv/ 11V, 3 Phase, 50 Hz Delta/Star Connected, Outdoor, Oil Filled, Completewithall Fittings Such As Thermometers, Buchholz Relay, With Off Circuit Tapp-Changer + 5 % To –15%, Tapping At The Step Of 1.25% With Rating Plate & Winding Temperature Indicator & Protection , Oil Temperature Indicator & Protection, Lifting Lugs, H. T. Cable Box/ Lt Box Etc. , 21 - Supply, Installation, Testing And Commissioning Of One Set 33Kv, 1500Mva Indoor Type Metal Clad Floor Mounted Vermin Proof Horizontal Drawout Fully Interlocked Vertical Isolation Vacuum Circuit Breaker Panel Board Fabricated Out Of Minimum 2Mm Thick Crca Sheet As Per Specifications. The Panel Shall Be Complete With All Accessories / Fitting / Wiring Like Insulated Copper Busbar, Cable Termination Boxes Suitable For 3C X 300 Sqmm Xlpe Armoured, Aluminium Conductor Cable For Incoming And Outgoing Feeder, Foundation Bolts Etc. Complete As Required And As Per Attached Specified , 22 - Supply And Laying Of 3 Core 240Sqmm Standered Aluminium Conductor Xlpe (Cross Linked Polyethylene) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S.7098 (Part-Ii With Latest Amendments) Iikv Grade. The Armouring Of Cable Shall Be Properly Connected With Earth Conductor By Clamps Etc. , 23 - Cable Jointing Of 33 Kv 240Sqmm Grade Xlpe Insulated Armoured Cable With Suitable Cable Termination Using Raychem/Birla 3M/Mecp Kits Including All Accessories I.E. Sockets, Lugs, Gland Etc As Required But Without Cable Box. , 24 - Supply, Installation, Testing And Commissioning Of 11Kv, Incoming Vcb Feeder Panel 26.3Ka Indoor Type Metal Clad Floor Mounted Vermin Proof Horizontal Drawout Fully Interlocked Horizontal Isolation Vacuum Circuit Breaker Panel Board Fabricated Out Of Minimum 2Mm Thick Crca Sheet As Per Specifications. The Panel Shall Be Complete With All Accessories / Fitting / Wiring Like Insulated Copper Busbar, Cable Termination Boxes Suitable For Upto 3C X 300 Sqmm Xlpe Armoured, Aluminium Conductor Cable For Outgoing Feeder, Foundation Bolts Etc. The Panel Shall Be Installed Along With Existing 11Kv Vcb Panel And Prices Quoted With Coupling Bus Bar To Be Connected The Above Panel With Existing Vcb Panel Along With All Alignemet & Conection. The Panel Shall Be Scada Compitable And Shall Be Provided With Suitable Metering To Measure Import / Export Energy Data On Scada Also. The Job Shall Be Completed As Per Site Requirement And As Per Attached Specification. , 25 - Supply Of Single Panel(1 Incoming + 5 Outgoing + 1 Bus Coupler Vcb Panel) Set 11Kv, 500Mva Indoor Type Metal Clad Floor Mounted Vermin Proof Horizontal Drawout Fully Interlocked Vertical/Horizontal Isolation Vacuum Circuit Breaker Panel Board Fabricated Out Of Minimum 2Mm Thick Crca Sheet As Per Specifications. The Panel Shall Be Complete With All Accessories / Fitting / Wiring Like Insulated Copper Busbar, Cable Termination Boxes Suitable Forupto 3C X 300 Sqmm Xlpe Armoured, Aluminium Conductor Cable For Incoming And Outgoing Feeder, Foundation Bolts Etc. Complete As Required And As Per Attached Specification , 26 - Overhauling Of 500Kva 11/.415Kv Distribution Transformer , 27 - Design And Manufacturing Of Moving Trollysuitable For 500Kva 11/.415Kv Transformer , 28 - Supply & Installation Of 33Kv Terminal Gantry With Structure To Receive 33Kv Power From Existing 33Kv Bus Available Already In Switchyard. The Job Includes All G.I. Structure, Steel Sections Xross Arms Etc. With Foundation, Painting Of Pole And Including Pin & String Insulator, Suppots Hardware Etc. , 29 - Supply, Erection, Testing And Commissioning Of 33 Kv 630 Amps Triple Pole Isolator With Earthing Heel As Per Latest Is:9921 (Pt-I To V) , 30 - Supply, Erection Of 33 Kv Current Transformer Single Phases Conforming To Is:2705(Pt.I To Iv) A) Core 1 (Metering) 150-75/1A Class 0.2, 20Va B) Core 2 (Protection) 150-75/1A Class 5P10, 20Va , 31 - Supply, Erection, Testing And Commissioning Of 33Kv 800 A, 1250 Mva Out Door Type As Per Technical Specification Enclosed Vacuum Circuit Breaker Complete As Per Latest Is:13118. , 32 - Erection Of 30Kv ,10Ka Lightening Arrestor With Insulating Base And Surge Counter As Per Latest Is:3070 Part I/1985 ( Latest Version) , 33 - Supply, Erection, Testing And Commissioning Of Control & Relay Panel For Single Transformerwith Suitable Protection And Controls For All Isolators & Vcb. The Panel Shall Be Scada Compitable And Shall Be Sujitable To Operated From Remote Control Station , 34 - Terminal Connector To Receive From 33Kv Line (Terminal Gantry) Suitable For Acsr Conductor , 35 - Terminal Connector To Receive To Bus Isolator Suitable For Acsr Conductor , 36 - Terminal Connector For Lightning Arrestor Suitable For Acsr Conductor , 37 - Terminal Connector For Ct Suitable For Acsr Conductor , 38 - Terminal Connector For Vcb Suitable For Acsr Conductor , 39 - Erection Of T Clamp For Acsr Conductor , 40 - Galvanised Structure For Lightning Arrestor With All Section Cross Arm Etc. , 41 - Galvanised Structure For Line Isolator With All Section Cross Arm Etc. , 42 - Galvanised Structure For Current Transformer With All Section Cross Arm Etc. , 43 - Galvanised Structure For Vaccum Circuit Breaker With All Section Cross Arm Etc. , 44 - Acsr Conductor 0.2 Inch(Nominal Area 200 Sqmm) , 45 - Marshalling Box For Ct , 46 - Misc Itms Other Than Above Items , 47 - Cordination, Engineering & Misc Job For Complete Substation , 48 - Supply, Erection, Testing And Commissioning Of Battery Charger Float Cum Boost Along With Input & Output Mcbs,Amp, Volts Meter, Interconnections Etc. Power Supply 230 V, 1 Phase, 50 Hz ± 10%. Charger Troubleannunciation Shall Be Provided Through Led. , 49 - Supply Erection Testing & Commissioning Of 100Ah Battery Bank Capacity Consisting Of 12Nos. 2V Tubular Cell Alongwith Mounting Cabinet And Copper Connection Leads Etc. , 50 - Pre Noc & Noc After Completion Of Work From Statuary Authority Is Essential For Every Service As Required. Viz.Electrical Panels, Transformers From Directorate Of Electrical Safety , State Government / Competent Authority. , 51 - Supply And Laying Of 400Sqmm 3.5 Core Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. , 52 - Supply And Laying Of 240Sqmm 3.5 Core Aluminium Conductor Pvc Insulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. Total Quantity : 1