Uttar Pradesh Projects Corporation Limited has published Construction Of Model Multipurpose Seed Store And Technology Dissemination Center At- Koyalsa Distt-Azamgarh. . Submission Date for this Tender is 25-01-2022. Building Work Tenders in azamgarh Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-Jan-2022 | Date Corrigendum | Date | 18-01-2022 |
2 | 18-Jan-2022 | DATE | Date | 25-01-2022 |
Sl. No. | Item Description |
1 | Construction of Model Multipurpose Seed Store & Technology Dissemination center atKoyalsa, Distt.-Azamgarh (U.P.) |
2 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
3 | Filling of carted Earth. |
4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
5 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
6 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete |
7 | (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
8 | (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer"s standard dilution) |
9 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone aggregates) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. |
10 | Ground Floor |
11 | First Floor |
12 | As in item no. 6 above but for slabs (Using 1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) Mix concrete) (M-20) |
13 | Ground Floor |
14 | First Floor |
15 | As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) Mix concrete) (M-20) |
16 | Ground Floor |
17 | First Floor |
18 | As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete).(1 cement : 1.5 coarse sand : 3 stone aggregates).(M-20) |
19 | As in item 3 above but in R.C.C. columns in1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) having strength not less than (M-20). (PWD- 289) |
20 | Ground Floor |
21 | First Floor |
22 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
23 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
24 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
25 | Same as in item no. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) |
26 | Ground Floor |
27 | First Floor |
28 | Same as in item no. 14 but in1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
29 | P/F Mild Fe 500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
30 | Ground Floor |
31 | First Floor |
32 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)F.M. 2.25 |
33 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand F.M. 2.25 |
34 | Ground Floor |
35 | First Floor |
36 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand F.M. 2.25 |
37 | Ground Floor |
38 | First Floor |
39 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
40 | Supply & fixing 6 mm thick china white glazedflooring or skirting dado laid with 1 :3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labours & tools etc, required for completion of the work. (size of tiles upto 200x 300 mm). |
41 | Supply & fixing 6 mm thick china white glazedflooring or skirting dado laid with 1 :3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labours & tools etc, required for completion of the work. (size of tiles upto 200x 300 mm). |
42 | 25mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
43 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
44 | Ground Floor |
45 | First Floor |
46 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. |
47 | Ground Floor |
48 | First Floor |
49 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red |
50 | Ground Floor |
51 | First Floor |
52 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red |
53 | Ground Floor |
54 | First Floor |
55 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
56 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
57 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
58 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
59 | Providing & fixing of hold fast for chaukhatsof doors and windows. |
60 | Providing & fixing of door / windows grill. |
61 | Z-Section steel windows (openable) |
62 | Angle iron door chaukhat 40*40*5 |
63 | Fixing of Door, windows/ventilators chaukhats in position. |
64 | Door chaukhats |
65 | Window chaukhats |
66 | Ventilator chaukhats |
67 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. |
68 | Ground Floor |
69 | First Floor |
70 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
71 | Ground Floor |
72 | First Floor |
73 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (For Ceiling) |
74 | Ground Floor |
75 | First Floor |
76 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
77 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
78 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
79 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. |
80 | (a) 150 mm x 10mm |
81 | (a) 200 mm x 10mm |
82 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm. |
83 | Providing & laying "brick Coba" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
84 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
85 | Same as item above but on new wood surface. |
86 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
87 | Construction of drain alongwith apron. (150x150)mm |
88 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.(Anti skid/mat finished tile) |
89 | Supplying and fixing rolling shutters of approved make, 80x125mm (3"x18gauge) cold roldM.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete,but excluding the cost of top cover and spring. |
90 | Providing & Fixing 27.5cm long wire spring grade-2 for rolling shutter. |
91 | P/F top cover for rolling shutteer made of 18gauge MS sheet. |
92 | Providing and fixing ball bearing for rolling shutters. |
93 | SANITARY FIXTURES & ACCESSORIES : I |
94 | Providing & fixing white vitereous china water closet squatting pan ISI marked (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10/12.5 litrsPVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush pipe with fitting & clamps, 20mm over flow pipe with specials and mosquito proof coupling of approved municipal design, painting wherever required including cutting & making good the walls & floors where required. |
95 | Orissa Pattern W.C. pan of size580x 440mwith integral type foot rests flush pipe and over flow arrangement. |
96 | Same as above but for European type W.C. pan with black plastic seat and lid. Make- Cera, Hindustan. |
97 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mmbrass pillar taps, brass chain with rubber plug, 32mmbrass waste of standard pattern including cutting & making good the walls wherever required. |
98 | a) Flat back wash Basin size 550x400 mm with single 15mmbrass pillar tap. |
99 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
100 | 32 mm dia |
101 | Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. |
102 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
103 | 15 MM nominal bore |
104 | Providing and Fixing C.P brass Abulation health faucet assembly with 1.0 m long braided PVC hose with mounting brackets fixed on wall complete. [FOR EWC] |
105 | Providing and Fixing C.P. brass Two-way angle valve for EWC points & for fixing Abulation Health Faucet of approved quality conforming to IS:8931 15mm nominal bore |
106 | Supplying & Fixing of CP soap tray fixed to the wall with PVC rubber plug with CP brass screws- Make -ESSCO AEC=1131 |
107 | SOIL WASTE & VENT PIPES AND FITTINGS - II |
108 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
109 | 110 mm diameter |
110 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
111 | 110 mm |
112 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
113 | Providing, Fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS:13592 suitable for rubber ring joints for horizontal pipes including all necessary specials and fittings (confirming to IS:14735) i.e, bends tees junctions (with or without doors). reducers WC connectors, couplers, cowels, clamps & hangers rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamps & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382 (Make :Supreme /Finolex / Prince) (Pipe support: Intellotech / Easyflex / Chilly. |
114 | The Pipes will be supported by either rubber lined G.I. U strip clamps on 50X50X5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all supported arrangements. The Work includes cutting holes in wall/ floor/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work include commissioning of all pipes lines as per drawings and specification and as directed by engg. in. |
115 | 110 mm dia |
116 | 75 mm dia |
117 | Providing & Fixing UPVC Floor trap of self cleaning design with CP Jali complete in all respects. (Make : Supreme / Finolex) |
118 | 110 X 110 mm P-Type |
119 | Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
120 | Reducing Tee 100X100X75mm |
121 | Door Tee |
122 | 110X110X75mm |
123 | 75X75X75mm |
124 | Bend |
125 | 110 mm |
126 | 75 mm |
127 | Terminal guard |
128 | 110 mm |
129 | 75 mm |
130 | WATER SUPPLY PIPES AND FITTINGS - III |
131 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
132 | (Internal Work) |
133 | Expansion on Wall |
134 | 32 mm dia nominal bore. (medium duty) |
135 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. |
136 | 32 mm diameter pipe. |
137 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
138 | 25 mm nominal outer dia Pipes |
139 | 40 mm nominal outer dia Pipes |
140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
141 | 15 mm nominal outer dia Pipes |
142 | 20 mm nominal outer dia Pipes |
143 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
144 | 15 mm nominal bore |
145 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
146 | 15 mm nominal bore |
147 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
148 | 15mm nominal bore |
149 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
150 | 25 mm nominal bore |
151 | 32 mm nominal bore. |
152 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
153 | 25 mm nominal bore |
154 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
155 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. |
156 | WIRING POINTS |
157 | Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in P.V.C. conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable as earth wire drawn inside &piano typeswitch and ceiling rose/angle/batten holder on 3 mm thick phinolic laminated backelite sheet etccomplete in all respects as directed including matching colour wash. |
158 | Same as in item no. 1 but for two way light. |
159 | Same as in item no. 1 but for fan. and light duty exhaust fan |
160 | Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. |
161 | Same as in item no.1 but for call bellwith piano type switch or socket etc. |
162 | Add for light / fan points with modular type switch in place of piano type switch. |
163 | Add for 2 way light point with modular switches in place of piano type switches. |
164 | Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch. |
165 | Add for plug point with modular switch & socket in place of piano type switch & socket. |
166 | Add for Call bell point with modular type bell push in place of piano type bell push. |
167 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor |
168 | cable as earth contunity wire etc. complete in all respects. |
169 | Supply and wiring of submain with two number 6 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core aluminium conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 14 SWG copper earth continuity wire including matching colour wash etc. complete in all respect. As in item no. 222 (B) but in 25 mm dia heavy duty (2 mm thick) PVC conduit with one number 4 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. |
170 | Supply and fixing of batten / angle holder complete in all respect. |
171 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
172 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
173 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA |
174 | Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board including making connections etc. complete in all respect. |
175 | Supply and fixing of buzzer on polished MDFEG / Teak ply board including making connections etc. complete in all respect. |
176 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. |
177 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. |
178 | Supply & Fixing of two number 8 SWG G.I wire for earthing purpose as required complete in all respects. |
179 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve |
180 | 5 - 32 amps. CAT- A |
181 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve. CAT A |
182 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve. CAT A |
183 | S & F surface/Flush mounting 6ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge.CAT A |
184 | S & F surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge. CAT A |
185 | Supply and fixing of crimping, solderless, copper tin electroplated lugs of Dowells/Ismail make suitable for 1.5 sq.mm to 2.5 sq.mm cables, including tapping with insulating tape, complete in all respect. |
186 | S&F single pole MCB blanking plate. CAT B |
187 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. |
188 | Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect. |
189 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. |
190 | Making hole in the wall for exhaust fan and finishing properly complete in all respect. |
191 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
192 | Supply and fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. |
193 | Supply and erection of AC 1200 mm Sweep 230/250 Volts , 50Hz ceilling fan with regulator standar down rod, blades including connection etc. complete as required. |
194 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. |
195 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. |
196 | S&F of 63 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour,T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. |
197 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
198 | 2 Pair |
199 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
200 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
201 | Telephone socket outlet |
202 | TV antenna socket outlet |
203 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
204 | 75 mm X 75 mm X 60 mm deep |
205 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
206 | 1 or 2 Module (75mmX75mm) |
207 | Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete as required - Make USHA Cat No TURBO JET DLX |
208 | 300 mm sweep 900 rpm |
209 | FIRE FIGHTING SYSTEM |
210 | Supply & fixing of fire extinguishers, ABC type 4.00 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
211 | Supply & fixing of fire extinguishers, CO2 type 4.50 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
212 | EXTERNAL SEWERAGE & SEPTIC TANK |
213 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
214 | a) Pipes 80mm to 300mm diameter. |
215 | Providing, Fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS:13592 suitable for rubber ring joints for horizontal pipes including all necessary specials and fittings (confirming to IS:14735) i.e, bends tees junctions (with or without doors). reducers WC connectors, couplers, cowels, clamps & hangers rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamps & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382 (Make :Supreme /Finolex / Prince) (Pipe support: Intellotech / Easyflex / Chilly. |
216 | The Pipes will be supported by either rubber lined G.I. U strip clamps on 50X50X5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all supported arrangements. The Work includes cutting holes in wall/ floor/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work include commissioning of all pipes lines as per drawings and specification and as directed by engg. in. |
217 | 110 mm dia |
218 | 75 mm dia |
219 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
220 | a) 150mm diameterS.W. Pipe |
221 | Constructing brick masonry manholewith F.P.S.bricksin cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design |
222 | Inside size 90 x 80 cm & 45 cmdeep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not lessthan 38 kg (wt. of cover 23 kg and wt. of frame 15 kg) |
223 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) |
224 | Extra for depth for manholes |
225 | Size 90x80 cm |
226 | Size 120x90 cm |
227 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design |
228 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
229 | 180x150 mm size P type |
230 | SEPTIC TANK WITH SOAK PIT |
231 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. |
232 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
233 | Brick work with brick of class desigation 150 in foundation & Plinth in cement motar (1 cement 4 coarse sand). Septic tank. |
234 | Reinforcement cement concrete work in slab cover for septic tank 1:1.5:3 |
235 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (Fe-500) |
236 | 12 mm cement plaster inside of septic tank of mix 1:4 (1 cement : 4 coarse sand) |
237 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
238 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay Class-150 M |
239 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
240 | Providing & fixing C.I. tee at the inlet and outlet of septic tank. |
241 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
242 | Providing & fixing of 75 mm dia cast iron terminal guard. |
243 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality |
244 | MD- 10 Circular shape 500 mm internal diameter. |
245 | LD- 2.5Circular shape 450 mm internal diameter |
246 | [ RAINWATER HARVESTING] |
247 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
248 | In all kind of soil upto 1.5m depth |
249 | In all kind of soil upto 1.5m to 3.0m. depth |
250 | In all kind of soil upto 3.0m to 4.5m. depth |
251 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
252 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
253 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. |
254 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
255 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)F.M. 2.25 |
256 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design |
257 | With 20x20 mm square bar |
258 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityCircular shape 500 mm internal diameter. M D - 10 |
259 | 19.2.2 150 mm diameter S.W. pipe |
260 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
261 | 300 mm dia |
262 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
263 | 150 mm nominal size dia |
264 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
265 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
266 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
267 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. |
268 | Pipes 80 mm to 300 mmdiameter |
269 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete |
270 | 150 mm diameter |
271 | 200 mm diameter |
272 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
273 | 150 mm diameter S.W. pipe |
274 | 200 mm diameter S.W. pipe |
275 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
276 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
277 | Submersible Pump |
278 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil, 300 mm dia |
279 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia |
280 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
281 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
282 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
283 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia |
284 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore |
285 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp |
286 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm clamp |
287 | Pumping set KSB make submersible pump set suitable for installation in bore well of min 110mm iner dia preferably more and having under noted specification. (1HP) |
288 | S/F of finolex of copper cable ISI marked submersible cable size 4sqm 4core. |
289 | C.C. Road |
290 | Earth work in exacavation in t. in ordinary soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c withinalead of 50m.(PWD-251) |
291 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors.(PWD-281) |
292 | Class 150 brick work in1:6cement and coarsesandof2.2fineness modulus mortar in foundation and plinth including supply ofall materials,labour andtools and plants etc.requiredforpropercompletion of the work. (PWD-303+307-306) |
293 | Layingc.c. road slab in cement concrete 1:1.5:3 (1 cement: 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors.(PWD-287 ) |
294 | M.S. work in R.c.c. |
295 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. DSR- 16.46.1 |
296 | Using grade "A" sealing compound. |
297 | Drain |
298 | Earth in excavation |
299 | P.C.C. infoundation (1 : 4: 8 ) |
300 | P.C.C. infoundation in 1:2:4 |
301 | Plaster12mm |
302 | Brick workin 1:6 |
303 | Interlocking |
304 | Preparation and consolidationj of sub grade |
305 | Earth work in excavation |
306 | P.C.C. 1:4:8 |
307 | B/W in Toe wall (1 cement : 4 coarse sand ) |
308 | Providing and laying 80mm thick cement concrete interlocking paver block |
309 | Furniture |
310 | DIAS TABLE (UPBEAT Define leg with Modesty) (COMPANY -GONDREJ, MODEL-LENIA) |
311 | DIAS CHAIR HIGH BACK(COMPANY -GONDREJ, MODEL-BEAT) |
312 | 3 SEATER BENCH (COMPANY -GONDREJ, MODEL-MATRIX) |
313 | GST Extra as per Applicable |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail