| 1 | Anti A Antisera, monoclonal,Each 10ml, As per NACO guidelines,WHO and NIB certified for blood bank use, DG registered10ml Cold chain 2-8Degree C & Shelflife 1-2 years | 1. Anti sera must be appropriate for microplate and tube technique.Must be monoclonal antibody.. Should give clear positive reactions with cells bearing the corresponding antigen Should give clear negative reactions with cells without the corresponding antigenShould not haemolyse the cells.Should not produce rouleaux . Avidity (time to positive reaction) less than 4 sec Titre: 256 or more.. Must be evaluated and approved by NIB. |
| 2 | Anti B Antisera, monoclonal,Each 10ml As per NACO guidelinesWHO and NIB certified for blood bank use, DG registeredCold chain 2-8Degree C & Shelflife 1-2 years | Anti sera must be appropriate for microplate and tube technique.Must be monoclonal antibody.. Should give clear positive reactions with cells bearing the corresponding antigen Should give clear negative reactions with cells without the corresponding antigenShould not haemolyse the cells.Should not produce rouleaux . Avidity (time to positive reaction) less than 4 sec Titre: 256 or more.. Must be evaluated and approved by NIB. |
| 3 | Anti AB antisera, monoclonalEach10ml As per NACO guidelines WHO and NIB certified for blood bank use, DG registered Cold chain 2-8Degree C & Shelflife 1-2 years | Anti sera must be appropriate for microplate and tube technique.Must be monoclonal antibody.. Should give clear positive reactions with cells bearing the corresponding antigen Should give clear negative reactions with cells without the corresponding antigenShould not haemolyse the cells.Should not produce rouleaux . Avidity (time to positive reaction) less than 4 sec Titre: 256 or more.. Must be evaluated and approved by NIB. |
| 4 | Anti D IgG (Monoclonal, low protein), Each 10mlcapable of detecting weak D and partial D WHO and NIB certified for blood bank use, DG registered | Anti sera must be appropriate for microplate and tube technique.Must be monoclonal antibody.. Should give clear positive reactions with cells bearing the corresponding antigen Should give clear negative reactions with cells without the corresponding antigenShould not haemolyse the cells.Should not produce rouleaux . Avidity (time to positive reaction) less than 4 sec Titre: 256 or more.. Must be evaluated and approved by NIB. |
| 5 | Anti D IgM (Monoclonal,), Each 10ml WHO and NIB certified for blood bank use, DG registered Cold chain 2-8Degree C & Shelflife 1-2 years | Anti sera must be appropriate for microplate and tube technique.Must be monoclonal antibody.. Should give clear positive reactions with cells bearing the corresponding antigen Should give clear negative reactions with cells without the corresponding antigenShould not haemolyse the cells.Should not produce rouleaux . Avidity (time to positive reaction) less than 4 sec Titre: 256 or more.. Must be evaluated and approved by NIB. |
| 6 | Anti A1 (Dolichos biflorus lectin) Each 5ml or 10ml WHO and NIB certified for blood bank use, DG registered | 1. Ready to use Dolichos biflorus Lectin solution. should give 2-3+ react6ion with seconds for most normal A1 cells and clearly no reaction with A2 cells and O cells. should have a titrate of atleast 1:8 for A1 cells and 1:4 for A1B . Should not hemolyse or forum roleaux. should be approved by NIB for specific Blood bankuse for A1/A2 discrimination |
| 7 | Anti H (Ulex europeus lectin)Each 5ml or10ml WHO and NIB certified for blood bank use, DG registered Cold chain 2-8Degree C & Shelflife 1-2 years | 1. Ready to use Ulex europaeus Lectin solution.should give 4+ reaction with seconds for most normal O cells and clearly no reaction with Bombaycells . should have a titrate of atleast 1:8 for O cells andShould not hemolyse or forum roleaux. |
| 8 | Bovine Serum Albumin (22%) Each 5ml or 10mlCold chain 2-8Degree C & Shelflife 1-2 years | 1. Antisera must be appropriate for microplate and tube technique. Should not haemolyse the cells.Should not produce rouleaux.Should be Approved by NIB for specific blood bank use |
| 9 | AHG Antisera, monoclonal, monospecific anti IgG (Anti-Gamma heavy chain)Each 5mlor 10mlCold chain 2-8Degree C & Shelflife 1-2 years | 1. Antisera must be appropriate for microplate and tube technique.Should give clear positive reactions with appropriately sensitised cells.Should give clear negative reactions with unsensitised cellsShould not haemolyse the cells.Should not produce rouleaux Titre : a. For polyspecific minimum 128 for IgG and minimum 4 for C3d; b. for monospecific anti-IgG minimum 256 c. for monospecific Anti C3d minimum 16.Must be evaluated and approved by NIB and IVD (EC) |
| 10 | Papain Each 5ml or 10mlCold chain 2-8Degree C & Shelflife 1-2 years | As per NACO Guidelines Must be evaluated and approved by NIB |
| 11 | PT Reagents 1 BoxCold chain 2-8Degree C & Shelflife 1-2 years | Should be compatible with automated and semi automated instruments.Should have an expiry period of 1 year.Must be evaluated and approved by NIB or other quality certifications |
| 12 | APTT Reagents(actime) 1 Box (6 x 5 ml) Fibrinogen Reagents. Factor XIII (Fibronectine)Assay ReagentCold chain 2-8Degree C & Shelflife 1-2 years | Should be compatible with automated and semi automated instruments.Should have an expiry period of 1 year.Must be evaluated and approved by NIB or other quality certifications |
| 13 | CaCl2 Reagents 2 vialsCold chain 2-8Degree C & Shelflife 1-2 years | Should be compatible with automated and semi automated instruments.Should have an expiry period of 1 year.Must be evaluated and approved by NIB or other quality certifications |
| 14 | Factor -X Assay reagents1 Box Cold chain 2-8Degree C & Shelflife 1-2 years | Should be compatible with automated and semi automated instruments.Should have an expiry period of 1 year.Must be evaluated and approved by NIB or other quality certifications |
| 15 | Factor VIII1 (3 x 1 ml)Cold chain 2-8Degree C & Shelflife 1-2 years | Should be compatible with automated and semi automated instruments.Should have an expiry period of 1 year Must be evaluated and approved by NIB or other quality certifications |