Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-01-2022 | 1ST Corrigendum Notice | Technical Bid | 21-01-2022 |
| Sl. No. | Item Description |
| 1 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 Grade having a crushing strength ofin 15cm cubes at 28 days after mixing adn tests conducted in accordance with IS 456 and IS 516 in footing, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies,Column, Beam Parapets, Window sills, Lofts, Railings etc. with 12mm to 20mm size black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumb and finishing the exposed surfaces smooth including cost of scaffolding, watering and curing for the required period including cost of all materials with taxes, royalties transportation, loading and unloading, all labour, sundries, T&Pincluding hire & running charges of concrete mixer and vibrator etc complete as per the direction of the Engineer-in-charge but excluding the cost of materials and labour for reinforcement bars , centering and shuttering for the work. Second Floor |
| 2 | Third Floor |
| 3 | Providing & fixing TOR Fe-500 reinforcement bars for RCC work of required diameter of approved quality with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of M.S. Rods or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the specification & direction ofE-I-C. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) Second Floor |
| 4 | Third Floor |
| 5 | Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden centering materials with all necessary bracing, ties and supports with level centering covered with bituminous paper including provision of necessary holes and pockets, fan hooks or boxes, switch and board insert plates, clamps and extension bars etc. as per the direction of the Engineer-in-charge and dismantling and removing the shuttering after the required interval from the date of casting, including cost of all materials with transportation, taxes, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete.(a) Column & Beam Second Floor |
| 6 | Third Floor |
| 7 | Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden centering materials with all necessary bracing, ties and supports with level centering covered with bituminous paper including provision of necessary holes and pockets, fan hooks or boxes, switch and board insert plates, clamps and extension bars etc. as per the direction of the Engineer-in-charge and dismantling and removing the shuttering after the required interval from the date of casting, including cost of all materials with transportation, taxes, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete.(b) LintelSecond Floor |
| 8 | Third Floor |
| 9 | Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden centering materials with all necessary bracing, ties and supports with level centering covered with bituminous paper including provision of necessary holes and pockets, fan hooks or boxes, switch and board insert plates, clamps and extension bars etc. as per the direction of the Engineer-in-charge and dismantling and removing the shuttering after the required interval from the date of casting, including cost of all materials with transportation, taxes, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete.c) Roof Slab & ChajjaSecond Floor |
| 10 | Third Floor |
| 11 | Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden centering materials with all necessary bracing, ties and supports with level centering covered with bituminous paper including provision of necessary holes and pockets, fan hooks or boxes, switch and board insert plates, clamps and extension bars etc. as per the direction of the Engineer-in-charge and dismantling and removing the shuttering after the required interval from the date of casting, including cost of all materials with transportation, taxes, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete.(d) Staircase Second Floor |
| 12 | Flyash brick masonary work using (250mm x 120mm x 80mm) size Flyash bricks having crushing strength not less than 75 kg/cm2 in cement mortar mix (1:6) on (250mm thick) masonary walls after immersing the bricks for 6 hrs in water before use in superstrure and similar type of work as per drawings. including cost, conveyance, all taxes, royalties, loading and unloading of all materials, including cost of all labour, scaffolding, wateringand curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. Second Floor |
| 13 | Third Floor |
| 14 | Flyash Half brick masonary work using (125mm x 120mm x 80mm) size Flyash bricks having crushing strength not less than 75 kg/cm2 in cement mortar mix (1:4) on (250mm thick) masonary walls after immersing the bricks for 6 hrs in water before use in superstrure and similar type of work as per drawings. including cost, conveyance, all taxes, royalties, loading and unloading of all materials, including cost of all labour, scaffolding, wateringand curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. Second Floor |
| 15 | Providing 16mm thick cement plaster to the inside surface of masonary wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats only to proper plumbs and level as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties,labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. Second Floor |
| 16 | Third Floor |
| 17 | Providing 12mm thick cement plaster to the outside surface of masonary wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats only to proper plumbs and level as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties,labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. Second Floor |
| 18 | Third Floor |
| 19 | Providing 6mm thick cement plaster with cement mortar (1:4) to ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including, scraping, cleaning and finishing the plastered surface smooth by using wooden floats only to proper plumbs as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing ,sundries, T&P etc. complete as per direction of the Engineer-in-charge. Second Floor |
| 20 | Third Floor |
| 21 | Preparing surface and painting with weather coat paint of approved make, shade and quality in all heights of walls, ceiling, sun sheds fins etc. incl. providing scaffolding, cleaning, curing and supply of all materials and labour complete. Second Floor |
| 22 | Third Floor |
| 23 | Providing & Painting two coats with Plastic Emulsion panits of approved shademake or equivalent over a coat of primer and pop by means of roller to inside surface of new walls and ceilling, including preparation of base and finishing the surface smooth including all cost ofmaterials, labour, scafolding, T & P etc. complete as pe the direction ofE-I-C. Second Floor |
| 24 | Third Floor |
| 25 | Painting two coats with synthetic enamel paint of approved quality and approved shade confirming to ISI on steel/wood work to give an even shade over a coat of primer of approved quality and shade including sand papering and making the surface smooth in all floors at all heights including cost, conveyance, loading, unloading, taxes of all materials,labour, sundries, T& P scaffolding required for the work andcomplete in all respect as per specifications and directions of Engineer-in-charge.Second Floor |
| 26 | Third Floor |
| 27 | Providing, fitting and fixing in proper position seasoned and dressed Sal wood choukaths of size 75mmX 125mm of best quality in doors & windows as per approved design and drawings including cutting the grooves in choukaths as required, painting two coats of coal tar or hot bitumen to the rear face in contact with masonry or concrete surface and fixing with 35mm x 5mm size W.I. clamps including cost, conveyance, taxes of all materials, all labour, T&P etc. complete in all respect as per direction of Engineer-in-charge in all floors. Second Floor |
| 28 | Third Floor |
| 29 | Providingfitting and fixing factory made flush doors of 35mm thick finished with 4mm thick veneer and teak beadings/ lippings including polishing the exposed surface with melamine finish including supplying, fitting fixing wooden hinged cleats brassaldrops, tower bolts, door closure, mortice locks, iron hinges screws etc. complete as per requirement and any additional fittings as directed by the Engineer-in-charge. Second Floor |
| 30 | Third Floor |
| 31 | Supplying fitting and fixing Fibre Reinforced Polymer FRP composite door shutter with hinge as per approved section with glass fibre reinforced plastic moulded skins and a special sandwiched core, so as to impart monolithic composite structure as per approved technology (DST) to satisfy IS: 14856 door testing performance criteria including all complete. Second Floor |
| 32 | Supplying, fitting and fixing glazed window shutters made out powder coatedaluminiumsections of matt black finish, with all standard fixtures and fittingswith groove for inserting 5mm heat reflectiveGlazing of Saint Gobain Or Equivalent as per approved design, with glazing bar, nonfriction projection type hinges, lugs, steel peg stay 300mm long, point nose of approved quality, fixing in position with cement concrete (1:2:4) cutting holes mending good damages to match with the existing surface complete in all respects.Casement / sliding window (40 mm series) Second Floor |
| 33 | Third Floor |
| 34 | Supplying, fitting and fixing of powder coated M.S. window grillmade out of M.S. square bar / M.S. flats / M.S. angles as per approved drawing and design, cutting to required size and welding properly, finished smooth and sand papering, including cost, conveyance, taxes of all materials, required screws, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge in all floors. Second Floor |
| 35 | Third Floor |
| 36 | Providing & fixing600x600mm and 10mm thk vitrified tile in floor of approved quality, colour and size (area of each tile one piece not less than 0.36 sqm) over with application of 25 mm thick cement mortarof ( 1: 4)in proper slop and filling the gaps with white cement and colouring the surface with silicon paint finished as per the design & drawing with all cost of materials, labour,conveyance, taxesT&P and complete as per the direction of the Engineer-in-charge. Second Floor Flooring |
| 37 | Second Floor Skirting |
| 38 | Supplying, fitting and fixing in position 7-8mm thick ceramic floor tile of Kajaria/NITCO/JOHNSON ofsizes not less than 12\"X12\"of premiumquality and size inall floors & steps with application of 20 mm thick cement mortarof ( 1: 3)in proper slop and filling the gaps with white cement and colouring the surface with silicon paint finished as per the design & drawing with all cost of materials, labour,conveyance, taxesT&P and complete as per the direction of the Engineer-in-charge. Second Floor |
| 39 | Supplying, fitting and fixing in position 6.5-6.7mm thick ceramic concept walltile with borders of Kajaria/NITCO/ JOHNSON/ EURO of premium quality and size not less than 12\"X18\" in dadoes in all floors at all heights and riser of stepswith application of 12 mm thick cement mortarof ( 1: 3)in proper slop and filling the gaps with white cement and colouring the surface with silicon paint finished as per the design & drawing with all cost of materials, labour,conveyance, taxesT&P and complete as per the direction of the Engineer-in-charge. Second Floor |
| 40 | Providing and fixing 40mm dia stainless steel Pipe 2mm thick handrail over stainless steel structural balustrade already fixed in position as per drawing including cost of all materials, fabricating, labour, transportation, taxes, complete as per the direction of the Engineer-in-charge.Second Floor |
| 41 | Third Floor |
| 42 | Providing average 25mm thick grading Concrete with (1:2:2) using 6mm black hard granite chips using zycosil water proofingcompound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. complete as per direction of the Engineer-in-charge.Third Floor |
| 43 | Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 th. mm reflective (saint globin)with all taxes, scaffolding, labour , carrage etc. complete, grids make as per drawing and direction of EIC. The contractor wii submite the detail design, drawing and stability certificate to the Engineer-in-charge. |
| 44 | Providing fitting, fixing fan hook M.S. round rod of 16mmdia ( SAIL Steel)with all cost of material, labour, conveyance, T&P and complete as per the direction ofEngineer-in-charge. Second Floor |
| 45 | Third Floor |
| 46 | Waterproofing for terrace deck slab including preparation of the surface: The top surface should be cleaned of all the dirt, loose materials and kept dry. Incase of the pot holes/cracks, the same shall be repaired with applying polymer based water proofing compound in two parts to be mixed throughly by applying slowly on surface.Third Floor |
| 47 | Supplying all materials , labours , taxes and tools and plants for fitting and fixing of CPVC pipes conforming to ISO Specification with good quality including fittings and laying as per the site requirement etc., all complete including testing as per the direction and specification of Engineer-in-charge. 15mm dia |
| 48 | 20mm dia |
| 49 | 25mm dia |
| 50 | 40mm dia |
| 51 | Supplying all material, labour , T&P & fitting ,fixing the following different water supply fittings of brand TATA & JINDALapproved make with including supply of all necessary jointing materials etc. all complete as directed by the Engineer-in-charge. G.I ball valve.40mm diaBall Valve |
| 52 | 25mm diaBall Valve |
| 53 | Supplying all materials , labour , tools and plants and constructing valve chamber of inside size 300mm x 450mm x 450mm with cement concrete slab (1:1.5:3) mix of 75mm thick and brick work 125mm thick in cement mortar (1:4) using K.B Bricks having crushing strength 75 kg/cm2 over foundation concrete (1:5:10) and inside plastering in cement mortar (1:3) finished with a floating coat of neat cement slurry including curing complete as per approved drawing and specification and as per instruction of Engineer-in-charge. |
| 54 | Supplying all labour T&P and cutting holes in brick masonry wall in for takingpipes through and mending good the damages with supply of all required materials etc. complete as per the direction of the Engineer-in-charge. For 15mm to 50mm PVC pipe to pass in 125mm to 250mm thick wall |
| 55 | In R.C C Wall 125mm to 250mm thick wall |
| 56 | Supplying all labour T&P and materials and making grooves in brick walls vertically and horizontally to the required depth and width for fixingpipes & fittings of sizes15mmdiato25mmdiainthe grooves, testing the pipe line against leakage,and filling the grooves with cement mortar(1:4) to bring the surface to original level including cost of mortars, curing and conveyance of materialsetc. complete as per direction of the Engineer-in-charge |
| 57 | Supplying all materials , labour T&P and fittings required for fixing of NP or CP Brass or GM fixtures of following sizes and specification with leak proof threaded joints tightened with spun yarn and white zinc or any other method as required as directed including testing and rectification of detects, after testing complete as per direction of Engineer-in-charge.Bibcock |
| 58 | Pillar cock |
| 59 | Angular stop cock |
| 60 | CP Grating (125mm) |
| 61 | Connecting Pipe |
| 62 | Basin |
| 63 | Soap Dish |
| 64 | Towel ring |
| 65 | Towel rail 24\" |
| 66 | Waste pipe |
| 67 | Shower Head |
| 68 | Long body bib cock |
| 69 | Providing and fixing vitreous China water closet (European with seat and lid), of CP brass hinges & rubber buffers, 10 litre cascade dual flushing cistern with fittings and brackets, 40 mm flush bend of CP brass, 20 mm overflow pipe with specials & mosquito proof coupling complete, painting on brackets and making good the walls and floors wherever required. |
| 70 | Supply of all materials, labour, T&P , fitting and fixing in all floors fixed type bevelledplateglassmirrorofsize600mm x 450mm x 5.5mm thick best Indian make ,supply of 13mm thick asbestos backing and CP Brass screw including cost conveyance, taxes of all materials complete as per specification and direction of Engineer-in-charge. |
| 71 | Supply of all materials, joining materials , labour and T&P and laying PVC SWR PIPES of Standard make with ISI Mark duly approved by the Engineer-in-charge including jointing, earthwork in excvation oftrenches in all kind of soil to the required depth and refilling of pipe linetrenches in 0.3048 mtrs layers with 300 mm deep sand around cushion duly watered and rammed or fixing to walls, floors withsupply of necessary clamps, nails and cutting the pipe to length with wastage including supply of all Clamps, Clips, Endcaps &jointing materials etc, complete as per standard specification and direction of Engineer-in-charge.75mm dia ( ISI Marked ) |
| 72 | 100mm dia ( ISI Marked ) |
| 73 | Supplying all materials, labour T&P for jointing of the PVC SWR SEWER pipefittings of standard make duly approved by the Engineer-in-charge with joining materialetc. suitably required for fixing on 100mm dia soil waste pipe complete with requissite testing as directed by Engineer-in-charge.110mm dia \"P/S\" Trap |
| 74 | 110mm dia Bend Plain/T |
| 75 | 110mm Door Bend |
| 76 | 110mm dia. Floor trap |
| 77 | Fixing of PVC vent pipes Including labour & T&P all complete as directed by the Engineer-in-charge.100mm Pipe |
| 78 | 100mm Vent Cowl |
| 79 | Providing and fixing 2000 litres capacity P.V.C Over head(Sintex make) tankwith all piping and valve arrangement with all labour & materials ,including cost, T&P , scaffolding etc., complete as directed by the Engineer-in-charge.2000 Ltr Capacity |
| 80 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type Modular switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ V-Guard/ HPL) (Make of Modular Box-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) Group-C .Single light point controlled by one 6A switch or first light point or group control ( 2F) |
| 81 | Ex.fan point controlled by one 6A switch ( 2F) |
| 82 | Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ V-Guard/ HPL) ( 2F) |
| 83 | Recessed wiring to ceiling fan point including modular Stepped type regulator with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire-Finolex/ L&T/ Anchor/ Havells/ V-Guard/ HPL) |
| 84 | Supply & fixing of 5 / 6 amp socket outlet on existing switch board with6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connectionas per direction of Engineer in Charge.( 2F) |
| 85 | Supply, fixingwith recessed wiring to 5 / 6 amp socket outlet on separate board250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connectionas per direction of Engineer in Charge. ( 2F) |
| 86 | Supply & fixing of 2 x 6 amp socket outlet controlled by 2 nos6Amp on separate board, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connectionas per direction of Engineer in Charge.( 2F) |
| 87 | Supply & fixing of 6 pin 16 amp socket for Geyser250 V clip in type socket ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge. ( 2F) |
| 88 | Supply & fixing of 16 amp Switch for Geyser , 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge. ( 2F) |
| 89 | Supply & fixing of A.Csocket outlet with 20/25A modular plug socketincluding all accesories and connection as per direction of Engineer in Charge. ( 2F) |
| 90 | Supplying and installation of 32A DP Switch for AC modular type of reputed make as approved suitable for 240V including all accesories and connection as per direction of Engineer in Charge.( 2F) |
| 91 | Supply & fixing of 6 pin 16 amp socket outletwith 16Amp Switch, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge. ( 2F) |
| 92 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.( 2F)(For subsequent point of group control ) |
| 93 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to Switch Board & 16A socket points of 2F ) |
| 94 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to AC socket points ) |
| 95 | Recessed wiring to submain in 4 x 6 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For BDB-L\"s ) |
| 96 | Recessed wiring to submain in 4 x 10 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For BDB- P\"s) |
| 97 | Supplying and fixing of following mentionedway, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Legrand/Hager/Siemens/Schneidermake, or any other equivalent of reputed make ISI marked as approved.6Amp rating to 32Amp (SP) MCB |
| 98 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted following sizes TPN , MCB DBsuitable for 415 V, 3phase, 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.(But without MCB/ RCCB/ ISOLATOR) (Legrand/L&T/ Schneider) .6 Way (8 + 18) Double Door, Horizontal type |
| 99 | 8 Way (8 + 24) Double Door, Horizontal type |
| 100 | Supplying and fixing 25-63 Amps rating, FP, 415 volts, RCCB,100mA (L&T / Legrand/ Siemens /Schneider)make or any other reputed equivalentcatagoriesmake ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required.25Amp FP RCCB(100mA/300mA) |
| 101 | 63Amp FP RCCB(100mA/300mA) |
| 102 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.(Make-Philips/ Bajaj/ Havells/ Crompton)1x9 watt LED lamp of Ujalla Scheme ( Energy Efficiency Services Ltd - EESL ) on existing Angle/batten holder |
| 103 | 1x20W LED TL fitting with all connections similar to Jaquar lighting item No LGLZ01X020XN or equivalent |
| 104 | 1x15W LED Surface fitting with all connections similar to Jaquar lighting item No LZET03R015XC or equivalent |
| 105 | Supply, fixing of Street Light LED Luminaire with 45w LED Lamp ( with external SPD 10kV) on parapet wall of the building similar to Jaquar Item No LSTR01S045XCor equivalent to / Philips / Crompton / Wipro Makecomplete and interconnections with3Cx1.5sqmm FRLS PVC insulated cable. |
| 106 | Supply, Installation, Testing and Commissioning of BEE 5 star rated ceiling fan 1400mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. |
| 107 | Supply, Installation, testing and commissioning of exhaust fan of 225 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required. |
| 108 | Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored |
| 109 | Numbering ceiling fan / exhaust fan / fluorescent fittings as required |
| 110 | Supplying and fixingof clip in type modular T.V. antenna socket ISI marked onmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 111 | Recessed wiring to television point withcable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in in existing surface / recessedPVC conduit as required as per direction of Engineer in Charge. |
| 112 | Supplying and fixing of following sizes PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.20mm |
| 113 | Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required |
| 114 | Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete asrequired |
| 115 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 116 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 117 | Fixing of copper / G.I tape 20 mm x 3 mm thick on parapet or suface of wall for lightining conductor complete as required. ( For horizontal run) |
| 118 | Fixing of copper / G.I tape 20 mm x 3 mm thick on parapet or suface of wall for lightining conductor complete as required. ( For vertical run) |
| 119 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
| 120 | Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required. |
| 121 | Laying of copper / G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required. |