| 1 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 20mm nominal size). |
| 2 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 3 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 3.5 in foundations and plinth in : |
| 4 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 6 | 100 mm |
| 7 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. |
| 8 | 250 mm weighing not less than 150 gms. |
| 9 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 10 | 40 mm thick with 20 mm nominal size stone aggregate |
| 11 | Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. |
| 12 | 40 mm wide and 4 mm thick. |
| 13 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 14 | (i)Single socketed pipes. |
| 15 | 150 mm diameter |
| 16 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 17 | Bend 87.5° |
| 18 | 150 mm bend |
| 19 | Shoe (Plain) |
| 20 | 150 mm Shoe |
| 21 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 22 | 150 mm |
| 23 | 12 mm cement plaster of mix : |
| 24 | 1:6 (1 cement: 6 fine sand) |
| 25 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 26 | 1:6 (1 cement: 6 fine sand) |
| 27 | 6 mm cement plaster of mix : |
| 28 | 1:3 (1 cement: 3 fine sand) |
| 29 | Neat cement punning |
| 30 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 31 | Water thinnable cement primer. |
| 32 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 33 | Two coats. |
| 34 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 36 | One or more coats on old work. |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 38 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 39 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 40 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 41 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 42 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 43 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 44 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 45 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 46 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 47 | Dismantlingpowder coated / anodized aluminium partitons, doors and other frames including proper numbering, loading and unloading,stacking and placing at the required place in the building as directed by the Engineer-in-charge . (Area of partition is measured for payment) |
| 48 | Fixingpowder coated / anodized aluminum partitions and doors with available materials after making required sections as per the drawing for powder coated aluminum sections , particle board, glass panels and snap on beading including fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides wherever required etc,all complete as perthe directions of the Engineer-in-charge. |
| 49 | Pruning/Cutting branches of trees at all levels for avoiding entering houses and obstructing colony lighting and electrical wire free passing and disposing the cutting pieces away from the compound to the dumping ground as directedby the engineer-in-charge. |