Public Works Department-PWD has published Construction Of Bio Medical Waste Storage Room For Chc Drass Kargil Construction Of Bio Medical Waste Storage Room For Chc Drass Kargil. Submission Date for this Tender is 05-01-2022. Building Work Tenders in Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 31-Dec-2021 | cORRIGENDIUM | Other | 05-01-2022 |
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: |
2 | All kind of soil 80% |
3 | Ordinary rock 20% |
4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
5 | Dumping stone filling in horizontal on level incld. Cost of stone. And including carriage complete. |
6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including carriagecomplete |
8 | Reinforced cement concrete work in beams, suspended floors ,roofs having slope up to( 15degree)landings ,balconies ,shelves ,chajjas,lintals bands ,plain windows sills ,stair cases and spiral stair cases up to floor five level excluding the cost of centering ,shuttering ,finishing and reinforcement with 1:1.5:3(1cement:1.5coarse sand :3graded stone agg.20mm nominal size.) crushed |
9 | Reinforcement for RCC workincludingstraightening, bending, cutting, placingin positionand binding all complete .Hot rolled deformed bars. |
10 | Centering and shuttering including strutting, propping etc. and removal of form for: |
11 | Foundations, footings, bases of columns etc. for mass concrete. |
12 | Suspended floors, roofs, landings, balconies and access platforms. |
13 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
14 | Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete.1:2:4 (1 Cement: 2 coarse sand(zone-III) :4graded stone aggregate 20 mm nominal size).incld. Carriage Complete. |
15 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 2.5 Kg/m10 Gauge Thickness |
16 | Powder coated aluminum (minimum thickness of powder coated 50 microns) |
17 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM (2.3 Kg/m 10 Gauge Thickness) |
18 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) |
19 | With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
20 | CEMENT PLASTER (IN COARSE SAND) 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 coarse sand) |
21 | Providing and fixing plained eaves boarding including facia |
22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
24 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. |
25 | New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
26 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
27 | Preparing newly primed wooden surface for painting by way of filling of putty sand papering rubbing complete. |
28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
29 | Providing & Fixing finished brass hanging type floor door stopper with necessary screws etc complete. |
30 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete i.e Size of tile 600x600 mm |
31 | P/F 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in colours, shades except burgundy bottle green, black of any size asapproved by engineer-in-charge in Skirting, risers of steps, and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 course sand) and jointing with grey cement slurry @3.3kg/sqm including pointing the joint with white cement and matching pigments etc., complete. |
32 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
33 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
34 | Providing and fixing 3 layer Thermex Pipe PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
35 | PN-16 pipe , 25mm OD(SDR-7.4) |
36 | PN-16 pipe , 32mm OD(SDR-7.4) |
37 | Providing and fixing accessories of standard and quality make of approved manufacturer including all necessary fixtures required. |
38 | Alumunium L-Drops for room door |
39 | AlumuniumL-Drops for Windows |
40 | AlumuniumHandles for door |
41 | AlumuniumHandels for window |
42 | 15 mm C.P. brass tap with elbow operation lever |
43 | C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge. |
44 | Handles with lock system of main doors ( Godrej Make) |
45 | Providing and installation ofPUF (Puf Insulated Tanks) water tank capacity 1000 ltrs of approved brand (SYNTEX OR ANY OTHER APPROVED BRAND) as per direction engineer incharge |
46 | Supply and installation of High Quality self regulating heat tracerfor Specialized Heating Solutions for Winterisation of water pipeline including all accessoriescompleteincluding power connector-two way-6 sq.mm, w.p. splice connector,w.p. tee connector,end seal,mounting kit-w.p. jb,g.i. pipe strap 4",al. adhesive tape roll( 50 mm w x 20 m l),f.g. adhesive tape roll (DANFOSS Make OR CHROMALOXany other approved brand as per the direction of Engineer-In-Charge) |
47 | Supplying and fixing High Quality32mm ThickNitrile Insulation Tube for water pipelineof approved brand2 InchSize (Armaflex Class-o Armacell) including alumunium duct clading of approved quality and finish as per the direction of engineer in charge |