Name Of Work:-Providing Electrical Infra Structure Works For Cable Landing Station At Amni Under Kli Submarine Eable Project .Sh :Sitc Of Isms, Acs, Ip Cctv, Afas, Wlds , Rrs And Intruder Alarm System, AMINI-Kerala

Bharat Sanchar Nigam Limited-BSNL has published Name Of Work:-Providing Electrical Infra Structure Works For Cable Landing Station At Amni Under Kli Submarine Eable Project .Sh :Sitc Of Isms, Acs, Ip Cctv, Afas, Wlds , Rrs And Intruder Alarm System. Submission Date for this Tender is 05-01-2022. Alarm Systems Tenders in AMINI Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

30430206
Name Of Work:-Providing Electrical Infra Structure Works For Cable Landing Station At Amni Under Kli Submarine Eable Project .Sh :Sitc Of Isms, Acs, Ip Cctv, Afas, Wlds , Rrs And Intruder Alarm System
Indian
Kerala
AMINI
05-01-2022

Tender Details

Name Of Work:-Providing Electrical Infra Structure Works For Cable Landing Station At Amni Under Kli Submarine Eable Project .Sh :Sitc Of Isms, Acs, Ip Cctv, Afas, Wlds , Rrs And Intruder Alarm System

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
INR 45.05 Lakhs /-

BOQ Items

Name of Work:-Providing Electrical Infra structure works for Cable Landing Station at Amniunder KLI Submarine cable project .SH :SITCof IBMS, ACS, IP CCTV, AFAS, WLDS , RRS andIntruder Alarm system
Sl. No. Item Description
1PART-A - ELV INSTALLATION -BMS
2Workstation Machine: SITC of Workstation Machine with Intel® Core™ i7-11700 (2.5 GHz up to 4.9 GHz, 16 MB L3 cache, 8 cores), 16 GB DDR4-2933 SDRAM (2 x 8 GB) , 512 SSD storage and secondary2 TB HDD storage,4 GB GDDR6 dedicated graphics card, 400 W SMPS power supply with cabinet,wired keyboard with volume control and wired optical mouse ,10/100 Mbps Ethernet card,and with 802.11AC/ABGN PCIE WLAN WITH BLUETOOTH 4.2 SINGLE-CHIP CONTROLLER (Realtek) .The system should be supplied with 19.5" HD monitor, Laser jet Printer and Web-Cam . System should be supplied with (Windows 10 professional or above ) OS,and any other LicensedSoftware required to Load the BMS Software , complete as required. .If the Proposed Vendor Require Higher grade Machine that same shall be provided without any cost to Client.
3BuildingManagementSystemSoftware:SITC ofGUI based BMS Software .The Software should have distributed achitectureandto be installed at Work station Machinewith one client viewinglicense at operator workstationfor recording 30 days data. The BMS software should be integratingAir-Conditioning data,DDCControllers,ElectricalPanel,UPS, EnergyMeter,DGPanel,FireAlarmSystem,(Hardwired), security System alarm and notification (Hardwired), Vesda, Water leak detection System, Rodant repellant System etc. The alarmsandfaultsinFireAlarmSystem,CCTVandAccess control system should flow to BMS and give a pop up visual indication into BMS Work-station .The alarms as indicated in IOsummaryshouldbeavailableinBMSsystem.The license shall be priced for minimum 256 points . Thefirms should carryout soft integration for hardwired pointswithout extra cost.
4DDCController :SITCofUL Listed TCP/IP based freely programmable DDC controller with latest 32 bit microprocessor technology ,Real time clock,networking and inbuilt data buffer. Each controller shall have a minimum20MB MemoryEach standalone controller should be able to store minimum 15 days data. The controller shall be fixed in the suitable size powder coated MS box IP 54 rated with suitable power supply unit. Earthing bolt shall be provided for body earthing also.
5Sensors & Field Devices :SITCof Temperature cum Humidity Sensor of Resistance Temperature Detection Type of PT 1000 / NI 1000/ NTC 20k. These shall be two wire type sensors.The accuracy shall be at least +/- 1 deg C over the range and as per the detailed specification enclosed and Relative Humidity sensors shall capacitance type with an effective sensing range of 10% to 90%.The accuracy shall be ± 5 % or better complete as required as per the detailed specification.
6SITC of Layer II managed 24 ports POE switch with RJ45 ports 10/1000 mbps ports and two uplink gigabit ports.
7SITC of 24 ports 1 U preloded straight patch panel with IDC connectivity at the rear end and RJ 45 jack on front panel, 19" rack mountable. With cable support bar/kit as required.
8SITC of unshielded 4 twisted pair category 6 patch cord with factory fitted strain relief boots on either sides as required.(1 meter length)
9ACCESS CONTROL SYSTEMS
10Workstation Machine: SITC of Workstation Machine with Intel® Core™ i5-11400F (2.6 GHz up to 4.4 GHz, 12 MB L3 cache, 6 cores), 16 GB DDR4-2933 SDRAM (2 x 8 GB) , 512 SSD storage and secondary2 TB HDD storage,4 GB GDDR6 dedicated graphics card, 400 W SMPS power supply with cabinet,wired keyboard with volume control and wired optical mouse ,10/100 Mbps Ethernet card,and with 802.11AC/ABGN PCIE WLAN WITH BLUETOOTH 4.2 SINGLE-CHIP CONTROLLER (Realtekor Similar/Superior) . System should be supplied with (Windows 10 professional or above) OS,and any other LicensedSoftware required to Load the CCTV and Access controlSoftware , complete as required. .If the Proposed Vendor Require Higher grade Machine that same shall be provided without any extra cost to Client. Desktop: HP ENVY Desktop TE01-2250xt PC, OR Similar/Superior make.
11Biometric cum Finger Print Reader with inbuilt Controller : SITCof Biometric finger reader having inbuilt Controller, smartcard readers complete with enclosure, IP 65 Rated ,with modbus output and all accessories I/c door interface module (if applicable)etc. as per the detailed technical specification The reader log data should be transfer to server on real time basis. The reader should be capable of both enrolment purpose and access control purpose.
12Smart cardReader with inbuilt Controller : SITCof smart cardreader having inbuilt Controller complete with enclosure, IP 65 rated and all accessories i/c door interface module (if applicable) , ,with modbus outputetc. as per the detailed technical specification attached . The reader log data should be transfer to server on real time basis. The reader should be capable of both enrolment purpose and access control purpose.
13SMART CARD READERS: SITC ofSmart Card readers with stainless steel base plate with base box i/c door interface module (if applicable) etc as required. The read range shall be up to 4-9cm for Doors. The reader log data should be transferred to server on real time basis.
14SMART CARDS: SITCof Smart Cards, double side card holder and lanyard including printing on lanyard etc as required.
15EM-LOCK FOR DOORS: SITCof Electromagnetic Locks of 600 lbs holding force suitable for operating with 12/24V DCpower supplyi/c providingGreen /Red LEDindicationwith built-in door monitor status as per the specification.
16For single leaf doors
17For double leaf doors
18SITC of Stainless Steel type exit switch inside the room forDoors etc as required.
19SITCof Master switch for opening all access control doors in case of Emergency.
20MAGNETIC CONTACT:SITC of Surface/flush mounted type Magnetic Contact suitable for 5 million cycle operation etc as required.
21SITC ofuninterrupted switch mode battery backed power for the reader unit and door locks with following specifications .5amps 12/24 V Power supply unit, a Out put 12 /24 v dc @5 A , load regulation <2%,Operating Input 170 v to 260 v AC ,internal rechargeable 7 Ah batteries, reader operation 6 hours on battery , low battery cut off, Led visual indication on display ,wall mounting type with IP 54protection as required.
22Access Management software Including Attendance Software with license as per the detailed specification attached.The Client should be able to add user/ configure reader and should be able to generate reports.
23IP CCTV surveillance system
24SITC ofIndoor/outdoor Fixed Dome IR Camera having HD resolution ( 2000 x 1121 ) 2MP or better Low light colour cameras with sensitivity of minimum 0.18 lux. in color mode & 0.02 lux. in B/W mode along with power supply unit. The cameras shall use the 1/2.9 inch format CMOS/CCD imager and shall have a 3mmlens. The cameras shall have digital wide dynamic range (WDR) of up to 120 db. and minimum 10 Mtr IRThe Cameras shall be ONVIF ,POE and UL compliant and complete as per detailed specification attached.
25SITC, of 8 channel Network video recorder with H.264 Compression format or higher and Including the hard disk for recording @ D1 resolution, 15FPS for 60 days etc as per specification attached. vendor to provide minimum 6TB hard disk .The NVR Should have 8 channel POE port to power the camera.
26SITC 32" diagonal, 1920 x 1080 pixels LED monitoring screen with all mounting bracket, connection chord wire,remote control , with suitable portsetc as per the specification attached.
27CCTV viewing software to view analog CCTV and HD security cameras live from monitors. The client licensed software should also allow users to search and playback recorded video footage from NVR"s hard drive.
28SITC of 15 U Wall mounted Rack (Powder Coated /19"DIN, Mounting Hardware / OR / Pk-10, Round Pin 5/15A, Inlet Plug type 16A Indian Round Pin) with all accessories
29CAT6 cableSupply and layingof Cat -6 cable fittedwith strain relief boots on either sides to connect camera to NVR
30Supplying and fixing following sizes ofmedium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20mm
31AFAS (ADDRESSABLE FIRE ALARM SYSTEM):
32Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for BMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.
33Two Loop Panel.
34Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.
35Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as equired.
36Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
37Supplying, installation, testing & commissioning of addressable manual call point complete as required.
38Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
39Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
40Supplying, installation, testing & commissioning of addressable fire control module complete as required.
41SITCof addressable relay module for the Air Conditioners trip, Fire & other Third Party Outputs.etc. complete with required fitting fixtures and accessories for the system as per site conditions and specifications.( compatable with the above control panel)
42SITC of addressable monitoring module to monitor status of other systems complete with required fitting fixtures and accessories ( compatable with the above control panel) for the system as per site conditions and specifications.
43SITC of fault isolator to provide short circuit protection to the addressable loop complete with required fitting fixtures and accessories ( compatable with the above control panel) for the system as per site conditions and specifications.
44Supply and laying of 2 Core, 1.5 sq. mm copper conductor FRLS armoured cable on surface or existing cable tray including terminations etc complete as required.
45Supplyand fixing of 4.5 Kg CO2 type wall mounting fire extinguisher with hose of suitable length includingfirst charge/ refilling and providing hook, hose clamps and with ISI markon the extinguisher etc as reqd ( Note: The extinguisher shall be manufactured strictly as per BIS 13849 : 1993 bearing ISI Marke
46WATER LEAKAGE DETECTION SYSTEM:
47SITC of Water Leak Detection Panel with minimum 2 zone with required display and power supply unit, relay or other interface for connecting to BMS, complete as required.
48SITC of water leakage detection cable of minimum 5 mtrs. length suitable for the above panel complete as required.
49SITCof hooter cum strobe suitable for the above water leakage detection panel etc as required.
50RODENT REPELLANT SYSTEM:
51SITC of Rodent repellent system Panel with auto tuning capability of connecting 12 Satellites per console in individual cable to transducer, LCD display, with on-board controls, including all accessories such as stand / rack etc., as required.
52SITC of Transducer Satellite Stations, capable of Emitting Ultrasonic sound of frequencies 20 Khz and higher, including all accessoriescomplete as per relevant standards etc., as required.
53Supply, laying & fixing of 2 core flexible cable of suitable size for connectivity between the transducers and the master console suitable for rodent repellant system in suitable dia PVC Conduit, couplers,bends etc complete as required.
54Supply and laying of 4 core 1.5 sqmm Copper conductor shieldedFRLS Armoured cable for communicationon surface or existing cable trayetc complete as required.
55INTRUDER ALARM SYSTEM
56SITC of2 zone intruder Alarm panel alongwith power supply and battery back-up.The vendor to provide 7AH Battery for the same.
57SITC of Programable type Infra Redsensorwith precise and reliable detection , wide range detection with 10 to 70 degree , and digital micro controller with no volatile memory,housed in a high-impact ABS plastic with HDPE cover etc as required.
58SITC of LED two linedisplayKeypad for arming and disarming the Alarming system as required.
59SITCof hooter cum strobe suitable for the above water leakage detection panel etc as required.
60Supply and laying of 4-Core, 1 sq. mm copper conductor Shielded FRLS Armoured cable for Communication on surface or existing cable tray i/c terminationsetc complete as required. 1BMS-520M,2 ACS-260M,6 ASDS-20M,8 WLD-10M, 10 IAS-100M
61Note:- These hardwares shall be suitable for interconnection and connectivity among the other stand - alone system spread over 11 Cable LandingStations at Lakshwadeep Islands in future for monitoring and fetching the data aswell with patchup of software , but without changing physical architecture.
62Part-B AMC
63Comprehensive Maintenance of BMS, ACS, IP CCTV, AFAS,FSS, WLDS , RRS andIntruder Alarm system including 24 months warranty period. The agency should ensure trouble free operation and Monthly Preventive maintenance of the entire ELV system including periodical updating of preloaded software’s.
64Third Year
65Fourth Year
66Fifth Year
67Note : The preventive maintenance and clearing faults during a period ofsix monthsshall be measured as 1 (One )job for the comprehensive maintenance
68The agency should clear the faults/ complaints/ breakdownsas and when occurred without any extra cost as the costs included in warranty & AMC charges and ensure the trouble free operation of the system
69The vendor has to maintain the entire system during a period offive years (2 years warranty +remaining 3 years ascomprehensive maintanence ) withrequired upgradation of hardware and software if neededwithout any extra cost.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail