Supply And Refilling Of Oxygen Gas And Nitrous Oxide Supply And Refilling Of Oxygen Gas And Nitrous Oxide , Medical Oxygen In A Type Cylinders Certified For Medical Use As Ip 1996, Not Less Than 99.0 V / V Of Oxygen, Less Than 5Ppm Of Carbon Monoxide, Not More Than 300 Ppm Of Carbon Dioxide, Free Of Any Kind Of Halogen And Polymers, Free Of All Forms Of Oxidizing Substances, Absolutely Free Of Moisture And Filled Out Of Liquid Oxygen. , Medical Oxygen In B Type Cylinders Certified For Medical Use As Ip 1996, Not Less Than 99.0 V / V Of Oxygen, Less Than 5Ppm Of Carbon Monoxide, Not More Than 300 Ppm Of Carbon Dioxide, Free Of Any Kind Of Halogen And Polymers, Free Of All Forms Of Oxidizing Substances, Absolutely Free Of Moisture And Filled Out Of Liquid Oxygen. , Medical Oxygen In D Type Cylinders Certified For Medical Use As Ip 1996, Not Less Than 99.0 V / V Of Oxygen, Less Than 5Ppm Of Carbon Monoxide, Not More Than 300 Ppm Of Carbon Dioxide, Free Of Any Kind Of Halogen And Polymers, Free Of All Forms Of Oxidizing Substances, Absolutely Free Of Moisture And Filled Out Of Liquid Oxygen. , Medical Nitrous Oxide Gas In Bulk Cylinders As Per Ip 1996 Certified As Inhalation Analgesic, Manufactured From Ip Grade Ammonium Nitrate. If Any Alternate Technology Or Manufacturing Process Is Used The Same To Specified And All Inputs Regarding Quality Assurance And Probable Impurities Etc Must Be Provided, Should Not Contain Less Than 98.0%V / V Of Nitrous Oxide In Both Liquid And Gaseous Phase, Less Than 300 Ppm Of Co2 As Impurity, Less Than 10 Ppm Of Co As Impurity, Free Of Hydrogen Sulphide, Not More Than 2 Ppm V / V Of Nitrogen Dioxide Or Nitric Oxide In Both Liquid And Gaseous Phase, Free Of All Forms Of Reducing And Oxidizing Substances, Free Of Moisture Andeach Batch Must Have Passed Tests For Alkalinity, Arsenic And Phospine. , Compressed Medical Air Gas As Per Ip 1996 Certified As Inhalation Analgesic, Manufactured From Ip Grade Ammonium Nitrate. If Any Alternate Technology Or Manufacturing Process Is Used The Same To Specified And All Inputs Regarding Quality Assurance And Probable Impurities Etc Must Be Provided, Should Not Contain Less Than 98.0%V / V Of Nitrous Oxide In Both Liquid And Gaseous Phase, Less Than 300 Ppm Of Co2 As Impurity, Less Than 10 Ppm Of Co As Impurity, 6. Free Of Hydrogen Sulphide, Not More Than 2 Ppm V / V Of Nitrogen Dioxide Or Nitric Oxide In Both Liquid And Gaseous Phase, Free Of All Forms Of Reducing And Oxidizing Substances, Free Of Moisture Andeach Batch Must Have Passed Tests For Alkalinity, Arsenic And Phospine. , Liquid Medical Oxygen Certified For Medical Use As Ip 1996, Not Less Than 99.0 V / V Of Air, Less Than 5 Ppm Of Carbon Monoxide, Not More Than 300 Ppm Of Carbon Monoxide, Free Of Any Kind Of Halogen & Polymersfree Of All Forms Of Oxidizing Substances, Absolutely Free Of Moisture And Filled Out Of Pure Medical Air. , Installation Of Liquid Medical Oxygen Tank ( 6000 Kg ) As Per Specification And Terms And Conditions As Mentioned In Annexure-4Of The Tender Document.