Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And District Chamba ( H.P. ) ( Sub-Head- Providing E.I Therein ) Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And Dist, Chamba in Distt. Chamba-Himachal Pradesh

Public Works Department-PWD has published Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And District Chamba ( H.P. ) ( Sub-Head- Providing E.I Therein ) Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And Dist. Submission Date for this Tender is 28-12-2021. Building Work Tenders in Chamba in Distt. Chamba Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30363312
Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And District Chamba ( H.P. ) ( Sub-Head- Providing E.I Therein ) Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And Dist
Open Tender
Indian
Himachal Pradesh
Chamba in Distt. Chamba
28-12-2021

Tender Details

Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And District Chamba ( H.P. ) ( Sub-Head- Providing E.I Therein ) Construction Of Ware House For Storage Of Evms And Vvpats At Baloo Near Chamba In Tehsil And District Chamba ( H.P. ) ( Sub-Head- Providing E.I Therein )

Key Value

Document Fees
INR 500 /-
EMD
INR 42300.0 /-
Tender Value
INR 23.13 Lakhs /-

BOQ Items

Name of Work: Construction of Ware House for Storage of EVM"s and VVPAT"s at Baloo near Chamba in Tehsil and District Chamba (H.P.). (Sub-Head:- Providing E.I therein.)
Sl. No. Item Description
1Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
2Group C.
3( Make:- Legrand (Myrius),SCI, L&T(Oris), Anchor Roma (Plus)
4Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
5Group C.
6( Make:- Legrand (Myrius),SCI, L&T(Oris), Anchor Roma (Plus)
7Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
82x1.5 Sq. mm.
92x2.5 Sq. mm.
102x4.0 Sq. mm.
112x6.0 Sq. mm.
122x10 Sq. mm.
13(Make:- KEI, SCI, Polycab, Finolex)
14Wiring for circuit / sub-main with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. (4X4+2X4)HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
15(Make:- KEI, SCI, Polycab, Finolex)
16Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
17(Make:- KEI, SCI, Polycab, Finolex)
18Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
19(Make:- KEI, SCI, Polycab, Finolex)
20Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.
21PVC insulated HRFR LS Copper conductor 1.5 Sq. mm.
223x1.5 Sq. mm.
233x2.5 Sq. mm.
24(Make:- KEI, SCI, Polycab, Finolex)
25Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
26Make:- Legrand (Myrius)/ L&T(Oris)/Anchor Roma (Plus)
27Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
28Make:- Legrand (Myrius)/ L&T(Entice)/Anchor Roma (Plus)
29Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover platefor modular switches in recess as required:-
30Make:- Legrand (Myrius)/ L&T(Entice)/Anchor Roma (Plus)
3112 modules (205mmx135mmx60mm)
322 modules (78mmx78mmx50mm)
33Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
34Make:- Legrand (Myrius)/ L&T(Entice)/Anchor Roma (Plus)
35S.P. 5/ 6 Amps one way Modular switch.
365 pin, 5/ 6 Amps Modular socket outlet.
37Telephone Socket outlet, modular.
38TV. socket outlet, modular
39Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required.
401 Pair
41Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
42Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
4325 mm. dia
4450 mm. dia
45(Make:- Diplast, BEC, Finolex)
46Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
47Double door-4 way
48Double door-6 way
49Double door-8 way
50(Make:- L&T, Legrand, Schneider)
51Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, "C" curves, miniaturecircuit breaker of Single pole in the existing MCB DB complete with connections etc. as required.
52Supplying and fixing 63 Amps. rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:- L&T, Legrand, Schneider)
53Supplying and fixing 40 Amps. rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:- L&T, Legrand, Schneider)
54Supplying and fixing 63 Amps. rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:- L&T, Legrand, Schneider)
55Supplying and fixing 40Amps. rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:- L&T, Legrand, Schneider)
56Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, unarmoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:-
57Make:- KEI/SCI/Polycab/ L&T/Havells.
58Armoured cable 25 sq. mm (3.5 core)
59Armoured cable 50 sq. mm (3.5 core)
60Armoured cable 120 sq. mm (3.5 core)
61Providing and laying of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-
62Make:- KEI/SCI/Polycab/ L&T/Havells.
63Armoured cable 120 sq. mm (3.5 core)
64Earthing with copperearth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
65Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
66Supplying and laying 8 SWG Copper wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
67Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
68Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
69Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
70Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
7125 Liter capacity water heater (Cat-A)
72Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
73Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
74Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
75Exhaust Fan, Light duty, (Domestic) 300 mm sweep
76Exhaust Fan, Heavy duty, 450 mm sweep
77Providing installation, Testing and commissioning of Ceiling Fan with step electronic fan regulatorpaino type, including wiring the down rod of standred length (up to 30 Cm) with 16/0.20 mm twin twisted flixible, cotton braided cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
781200 mm sweep Make:- Usha (Technix Plus 3 Star) / (Bajaj (Ultima)/Crompton Greaves
791400 mm sweep Make:- Usha (Striker 1 Star) / (Bajaj (Ultima)
80Supplying and fixing surface mounting following size LED solution suitable for surface application with the use of the latest technology 6/12/15/18 Watt (600/1200/1500 lumen/1800) 6500K/3000K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
81Make:- Jaquar/Panasonic/ Philips & Havells.
82LED 12 WattCircular (Dia:175MM. Height: 35 mm)
83Cat No: LNRO02R012SC
84LED 18 WattCircular(Dia:225MM. Height: 35 mm)
85Cat No: LNRO02S018SC
86Supplying and fixing surface mounting following size LED solution suitable for surface application with the use of the latest technology 12/18 Watt (1200/1800 lumen) 6500K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.including 5 year warrenty as required.
87Make:-Jaquar/Panasonic/ Wipro/philips.
88LED 18 WattSquare (L x W: 225 mm X 225MM. Height: 35 mm)
89Cat No: LNRO02S018SC
90Supplying and fixing surface mounting following size LED solution suitable for surface application with the use of the latest technology 20/36/42 Watt (2000/3600/4200 lumen) 6000K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
91Make:- Jaquar/Panasonic/ Philips & Havells.
92Sauver (Surface)-20W/1ft.x1ft.
93Cat No:LSVR01S020XC
94Sauver (Surface)-42W/1ft.x4ft.
95Cat No:LSVR03S042XC
96Supplying and fixing LED Recess mounted Square panel with die cast aluminium housingwith the use of the latest technology 6/12/18 Watt (600/1200) 6500K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
97Make:-Jaquar/Panasonic/ Wipro
98LED 12 WattSquare (Cutout: 160 mmX160MM. Height: 20 mm)
99Cat No: LNNE01S012XC
100Supplying and fixing recess mounting following size LED solution suitable for surface application with the use of the latest technology 36 Watt (3600 lumen) 6000K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. including 5 year warrenty as required.
101Make:-Jaquar/Panasonic/ Wipro/philips.
102Sauver (Recess)-36W/2ft.x2ft.
103Cat No:LSVR01S036XC
104Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to20Watt (2000 lumen) 6500K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz,including one no. tube rod 20 Watt complete with all accessories, connections, testing and commissioning etc. as required.
105Make:-Jaquar/Panasonic/ Wipro/philips.
106LED Tube Fixture 20Watt(L x W:1135 x22mmHeight:37mm)
107Supplying and fixing fancy wall bracket of metal & synthetics white colour of superior quailitywith E27 lamp holdercomplete with all accessories, including making connections, testing etc. including 5 year warrenty as required.. Make-Jaquar, Panasonic,Wipro
108Fixed type wall bracket
109Cat No: JNL-CHR-WLRB0480SE27
110Supplying and fixing Pendant 1 LT Frosted glass with Rose Gold finishing of superior quailitywith E27 lamp holdercomplete with all accessories,including making connections, testing etc. as required. Make-Jaquar,Panasonic or as approved by Engineer in charge.
111Make:- Jaquar/Panasonic/ Philips & Havells.
112LED Pendant 9 Watt
113Cat No: JNL-RDG-SL00FRD1E27
1143-Light Pendant (3x9watt)
115Cat No: JNL-RDG-SL00FRD3E27
116Providing and fixing Bulk Head Fitting with high efficacy up to10Watt (1000 lumen) 6500K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz,including one no. tube rod 20 Watt complete with all accessories, connections, testing and commissioning etc. including 5 year warrenty as required.as .Make:-Jaquar/Panasonic/ Wipro
117LED Bulk head10Watt Cat No: LBLK02X010XC
118Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 10Watt (Mirror Light)(1000 lumen) 6500K and it should be compatible with specifications i.e. power factor = 0.9, harmonic distortion = 10% and efficacy = 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz,including one no. tube rod 20 Watt complete with all accessories, connections, testing and commissioning etc. as required.Make-Jaquar,Panasonic,Wipro
119Mirror lightLED 10Watt(L x W: 595 x22mm Height:37mm)
120Cat No: LGLZ01X010XC
121Supplying and fixing 32 Amp. power unit (with cable output) for geyser/ Air Conditioner including connections, installation, testing and commissioning etc. as required and to the best satisfaction of Engineer-in-charge.
12232 Amps. Power Unit
123Make:- Legrand (Myrius)/ L&T(Entice)/Anchor Roma (Plus)
124Supplying, installation testing and commissioning of 2.00 Ton capacity split type (Hot & Cold) Air Conditioning unit of following make confirming to I.S.I.-1391 Established since1884 with ammendment No.1(except power consumption norms) fitted with hermatically shielded air compressor as required complete in all respects:-
1252.00 Ton capacity split type (Hot & Cold) Air Conditioning unit.
126Make:-Voltas Model No.Voltas SAC 243VH SZS (Cat. No.4502742) or equivalent make.
127Providing and installation of copper pipe of size (3/8"x5/8") suitable for 2.00 Ton A.C. with insulation held properly by means of clamps and making good the damages complete in all respects as required at the site.
128Providing and installation of Stand suitable for hanging 1.5 Ton A.C. out door unitincluding embedding bolts in the wall and making good the damages complete in all respects as required at the site.
129Providing and installation of PVC drain pipe of size (25mm dia) with elbow and teeheld properly by means of clamps and making good the damages complete in all respects as required at the site.
130Supplying and fixing wall mounting voltage stablizer (Microtek Make) automatic type with output 240 Volts,voltage regulator range from 150 Volt to 290 Volts amd auto cut of beyond this range and time delay operation for surges and flutations suitable for 2.0 Ton capacity split AC making connection etc. as required.
131Microtek stablizer 150-290V. 4 KVA
132Make:-Microtek (CAT No: EM5150+) Upto 2.0ton AC or equivalent make.
133Supplying and drawing LAN cable CAT 6, solid copper conductorprotected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
134Make:-KEI/Polycab/D-Link or its equivalent make.
135Supplying and fixing RJ 45 Jack with cat 6 in the existing switch box / cover plate including connections etc. as required.
136RJ 45 Jack with cat 6 (1 moudule) Makes:- Legrand Mylinc/L&T /Schneider.
137Cat. No.: 6759 67
138Supplying and fixing Computer Network Switch 1000 (MBPS) million bits or 1000 Kilo bits of data per secondcomplete with all accessories, connections, testing and commissioning etc. as required. Make: D-Link or any other approved by Engineer-in-Charge.
1398 Port.
140Sub Panel for floor (Light) size: (1000mm (high) x 400mm (wide) x 300mm (deep)
141Supply,fabirication,installation,testing,commissioning and electrically connected Factory (CPRI approved) made,LT panel Board of approved size as recommended by IS & CPRI norms,indoor type,Floor Mounted 1000 Volt,made out off CRCA sheet 2.0mm thick for load bearing and and 1.6mm IP-54 (certificate not older than 2 year) protection with base frame of 5mm thick chanel for frame,for 415 volts,3 phase,4 wire AC supply,complete all as specified including provision of following accessary/components housed in -:(i) 63 Amps rated copper bus bar with colour code TPN mounted on epoxy insulator : 01 set (set for 04 bus bar).(ii) Earthing teminals and cable glands. (iii) Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door. (iv) Poowder coating:- Pure polyester grade RLA shade.
142Make:- EVA/Power system control/DB Electromatic Pvt. Ltd Make.
143The Panel shall include the following Switchgear & accessories; as per the Make of L & T,Schneider, C&S etc.
144Incoming-:
145(2) MCCB 40 Amps,4Pole,Adjustable thermal and fixed magnetic setting repture capacity 16 ka-1No.
146Outgoing:-
147(1) 63A DP Isolator. (Space only) 3 No.
148(2) 63ADP Isolator. (Space only) -1 No.
149(2) 6-32 Amps SP MCB. (Space only)- 12 No.
150Sub Panel for floor (Power) size: (1000mm (high) x 400mm (wide) x 300mm (deep)
151Supply,fabirication,installation,testing,commissioning and electrically connected Factory (CPRI approved) made,LT panel Board of approved size as recommended by IS & CPRI norms,indoor type,Floor Mounted 1000 Volt,made out off CRCA sheet 2.0mm thick for load bearing and and 1.6mm IP-54 (certificate not older than 2 year) protection with base frame of 5mm thick chanel for frame,for 415 volts,3 phase,4 wire AC supply,complete all as specified including provision of following accessary/components housed in -: (i) 63 Amps rated copper bus bar with colour code TPN mounted on epoxy insulator : 01 set (set for 04 bus bar).(ii) Earthing teminals and cable glands. (iii) Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door. (iv) Poowder coating:- Pure polyester grade RLA shade.
152Make:- EVA/Power system control/DB Electromatic Pvt. Ltd Make.
153The Panel shall include the following Switchgear & accessories; as per the Make of L & T,Schneider, C&S etc.
154Incoming-:
155(2) MCCB 63 Amps,4Pole,Adjustable thermal and fixed magnetic setting repture capacity 16 ka-1No.
156Outgoing:-
157(1) 63A DP Isolator. (Space only)
158(2) 63ADP Isolator. (Space only)
159(2) 6-32 Amps SP MCB. (Space only)
160Supply,fabirication,installation,testing,commissioning and electrically connected Factory (CPRI approved) made,LT panel Board of approved size as recommended by IS & CPRI norms,indoor type,Floor Mounted 1000 Volt,made out off CRCA sheet 2.0mm thick for load bearing and and 1.6mm IP-54 (certificate not older than 2 year) protection with base frame of 5mm thick chanel for frame,for 415 volts,3 phase,4 wire AC supply,complete all as specified including provision of following accessary/components housed in -: (i) 63 Amps rated copper bus bar with colour code TPN mounted on epoxy insulator : 01 set (set for 04 bus bar. (ii) Digital Multification metre 0.63Amps with Suitable CT"s-01 set. (iii) LED indicating lamp (set of three)- 01 Set. (iv) Internal wiring with 1100 volt grade unsheahed PVC insuladed copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable iugs as required and as per specified. (v) Earthing teminals and cable glands. (vi) Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
161Light Control Panel (1700mm (high) x 1600mm (wide) x 250mm (deep)
162The Panel shall include the following Switchgear & accessories; as per the Make of L & T,Schneider, C&S etc.
163Main Incomers -1
164(1) 63A 4P 25ka Fixed MCCB. (Spreader links Inc.) -1 No.
165(2) 63 amps 4P Manual Changeover Switch. -1 No.
166Outgoings
167(1) 40A, 4 Pole 16ka Fixed MCCB (Spreader links Inc.)- 4 No.
168All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wirewith thimbles, printed sleeves, tie & belt etc.
169The prices of complete job as per the specifications above shall be inclusive ofgasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
170Supply,fabirication,installation,testing,commissioning and electrically connected Factory (CPRI approved) made,LT panel Board of approved size as recommended by IS & CPRI norms,indoor type,Floor Mounted 1000 Volt,made out off CRCA sheet 2.0mm thick for load bearing and and 1.6mm IP-54 (certificate not older than 2 year) protection with base frame of 5mm thick chanel for frame,for 415 volts,3 phase,4 wire AC supply,complete all as specified including provision of following accessary/components housed in -: (i) 100 Amps rated copper bus bar with colour code TPN mounted on epoxy insulator : 01 set (set for 04 bus bar. (ii) Digital Multification metre 0.100Amps with Suitable CT"s-01 set. (iii) LED indicating lamp (set of three)- 01 Set. (iv) Internal wiring with 1100 volt grade unsheahed PVC insuladed copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable iugs as required and as per specified. (v) Earthing teminals and cable glands. (vi) Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
171Light Control Panel (1700mm (high) x 1600mm (wide) x 250mm (deep)
172The Panel shall include the following Switchgear & accessories; as per the Make of L & T,Schneider, C&S etc.
173Main Incomers -1
174MCCB 100 Amps, 4P 25ka Adj.T MCCB.(Spreader Links Inc.) - 1 No.
175Outgoing Feeders -1
17663 Amps 4P 16ka Fixed MCCB.(Spreader Links Inc.) . - 1 No.
17740 Amps 4P 16ka Fixed MCCB.(Spreader Links Inc.) . - 1 No.
178All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wirewith thimbles, printed sleeves, tie & belt etc.
179The prices of complete job as per the specifications above shall be inclusive ofgasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
180Supply,fabirication,installation,testing,commissioning and electrically connected Factory (CPRI approved) made,LT panel Board of approved size as recommended by IS & CPRI norms,indoor type,Floor Mounted 1000 Volt,made out off CRCA sheet 2.0mm thick for load bearing and and 1.6mm IP-54 (certificate not older than 2 year) protection with base frame of 5mm thick chanel for frame,for 415 volts,3 phase,4 wire AC supply,complete all as specified including provision of following accessary/components housed in -: (i) 300 Amps rated copper bus bar with colour code TPN mounted on epoxy insulator : 01 set (set for 04 bus bar. (ii) Digital Multification metre 0.300Amps with Suitable CT"s-01 set. (iii) LED indicating lamp (set of three)- 01 Set. (iv) Internal wiring with 1100 volt grade unsheahed PVC insuladed copper conductor of suitable size cable as per colour coding or suitable size of bus bar for all connections with suitable iugs as required and as per specified. (v) Earthing teminals and cable glands. (vi) Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door.
181Main Panel (1700mm (high) x 1600mm (wide) x 450mm (deep)
182The Panel shall include the following Switchgear & accessories; as per the Make of L & T,Schneider, C&S etc.
183Main Incomers -1
184MCCB 300 Amps, 4 Pole,Microprocessor based,repture capacity 35ka..(Spreader Links Inc.) - 1 No.
185SPD Type 1+2 3p+N 15ka - 1 No.
186Outgoing Feeders -1
187100 Amps, 3 Pole +N with suitable bolted/knife type H.R.C Fuse. - 1 No.
188100 Amps, 3 Pole +N with suitable bolted/knife type H.R.C Fuse. - 4 No.
189Secondary Material
190Busbar Copper 300 A TPN,50HZ Colour coded-1No.
191All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wirewith thimbles, printed sleeves, tie & belt etc.
192The prices of complete job as per the specifications above shall be inclusive ofgasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
193Supplying and laying of Rubber insulation mat 12mm thick, size (2 meter x 1 meter) as required complete in all respects.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,