}

Bids Are Invited For 50 Pair 0.5 Mm Jfc - ( I ) Conductor Diameter 0.50 Mm ( Ii ) Insulation Resistance At 500 V Should Be 5000 Mega Ohm / Km ( Iii ) Conductor Resistance ( Ohm / Km ) Should Be 86±6 ( Iv ) Attenuation At 150 Kv ( Db / Km ) Shall , kamrup-Assam

Indian Air Force has published Bids Are Invited For 50 Pair 0.5 Mm Jfc - ( I ) Conductor Diameter 0.50 Mm ( Ii ) Insulation Resistance At 500 V Should Be 5000 Mega Ohm / Km ( Iii ) Conductor Resistance ( Ohm / Km ) Should Be 86±6 ( Iv ) Attenuation At 150 Kv ( Db / Km ) Shall . Submission Date for this Tender is 21-02-2022. Chemical Supply Tenders in kamrup Assam. Bidders can get complete Tender details and download the document.




Tender Notice

30312243
Corrigendum : Bids Are Invited For 50 Pair 0.5 Mm Jfc - ( I ) Conductor Diameter 0.50 Mm ( Ii ) Insulation Resistance At 500 V Should Be 5000 Mega Ohm / Km ( Iii ) Conductor Resistance ( Ohm / Km ) Should Be 86±6 ( Iv ) Attenuation At 150 Kv ( Db / Km ) Shall
Indian
Assam
Kamrup
21-02-2022

Tender Details

Bids Are Invited For 50 Pair 0.5 Mm Jfc - ( I ) Conductor Diameter 0.50 Mm ( Ii ) Insulation Resistance At 500 V Should Be 5000 Mega Ohm / Km ( Iii ) Conductor Resistance ( Ohm / Km ) Should Be 86±6 ( Iv ) Attenuation At 150 Kv ( Db / Km ) Shall Not Exceed 8.25 Db / Km ( V ) Insulation Solid ( Mdpe / Hdpe ) ( Vi ) Resistance To Compression Range Be 200N, 12Vdc ( Vii ) Core Wrap Should Be Polyester Tape ( Viii ) Moisture Burner Be Poly Aluminium ( Ix ) Unarmoured ( X ) Far End Crosstalk ( Db ) At 150 Khz Individual Value Be 55 Db / Km Rms And Rms Should Be 67.8 Db / Km ( Xi ) Near End Crosstalk ( Db ) At 150 Khz Should Be Better Than 55 Rms , 20 Pair 0.5 Mm Jfc - ( I ) Conductor Diameter 0.50 Mm ( Ii ) Insulation Resistance At 500 V Should Be 5000 Mega Ohm / Km ( Iii ) Conductor Resistance ( Ohm / Km ) Should Be 86±6 ( Iv ) Attenuation At 150 Kv ( Db / Km ) Shall Not Exceed 8.25 Db / Km ( V ) Insulation Solid ( Mdpe / Hdpe ) ( Vi ) Resistance To Compression Range Be 200N, 12Vdc ( Vii ) Core Wrap Should Be Polyester Tape ( Viii ) Moisture Burner Be Poly Aluminium ( Ix ) Unarmoured ( X ) Far End Crosstalk ( Db ) At 150 Khz Individual Value Be 55 Db / Km Rms And Rms Should Be 67.8 Db / Km ( Xi ) Near End Crosstalk ( Db ) At 150 Khz Should Be Better Than 55 Rms , 10 Pair 0.5 Mm Jfc - ( I ) Conductor Diameter 0.50 Mm ( Ii ) Insulation Resistance At 500 V Should Be 5000 Mega Ohm / Km ( Iii ) Conductor Resistance ( Ohm / Km ) Should Be 86±6 ( Iv ) Attenuation At 150 Kv ( Db / Km ) Shall Not Exceed 8.25 Db / Km ( V ) Insulation Solid ( Mdpe / Hdpe ) ( Vi ) Resistance To Compression Range Be 200N, 12Vdc ( Vii ) Core Wrap Should Be Polyester Tape ( Viii ) Moisture Burner Be Poly Aluminium ( Ix ) Unarmoured ( X ) Far End Crosstalk ( Db ) At 150 Khz Individual Value Be 55 Db / Km Rms And Rms Should Be 67.8 Db / Km ( Xi ) Near End Crosstalk ( Db ) At 150 Khz Should Be Better Than 55 Rms , 400 Pair Pillar Box With Krone Module - 400 Pair Pillar Box With Krone Module Of Good Quality , 200 Pair Pillar Box With Krone Module - 200 Pair Pillar Box With Krone Module Of Good Quality , 100 Pair Pillar Box With Krone Module - 100 Pair Pillar Box With Krone Module Of Good Quality , 100 Pair Dp Box With Krone Module - 100 Pair Dp Box With Krone Module Of Good Quality , 50 Pair Pillar Box With Krone Module - 50 Pair Pillar Box With Krone Module Of Good Quality , 50 Pair Dp Box With Krone Module - 50 Pair Dp Box With Krone Module Of Good Quality , 20 Pair Pillar Box With Krone Module - 20 Pair Pillar Box With Krone Module Of Good Quality , 20 Pair Dp Box With Krone Module - 20 Pair Dp Box With Krone Module Of Good Quality , 10 Pair Dp Box With Krone Module - 10 Pair Dp Box With Krone Module Of Good Quality , 50 Pair Jointing Kit - ( I ) 50 Pair Tsf-2 ( Ii ) Unarmoured ( Iii ) Fully Petroleum Filled Jelly , 10 / 20 Pair Jointing Kit - ( I ) 20 Pair Tsf-1 ( Ii ) Unarmoured ( Iii ) Fully Petroleum Filled Jelly , Gi Pipe - ( I ) 40 Mm Thickness ( Ii ) Material Should Be Carbon / Steel Pipe Based , Route Marker For Jfc - ( I ) Material Should Be Metal Disc Of 5 Feet Long And 6 Inches Diameter ( Ii ) Coating Should Be Of Two Coasts Of Enamelled Paint Of Good Quality And Jfc Marked On Top , Laying Of Jfc At 5 Feet Depth - Laying Of Jfc At 5 Feet Depth. However, Manual Digging Needs To Be Resorted To Incase Of Terrain Constraints Or To Avoid Damage To Existing Power Cables, Communication Cables Or Water Pipes. Addtionally, Any Damage Occurred Due To Jcb Needs To Be Repaired And Made Serviceable And Vendor Shall Be Responsible To Bear All The Costs. Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-02-2022 21-02-2022
2 12-01-2022 03-02-2022

Key Value

Document Fees
Refer document
EMD
INR 21750.0 /-
Tender Value
INR 43.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail