Public Works Department-PWD has published Urgent Upgradation Of All 14 Phe Laboratories Including Supply Of New Instruments Equipments Instrument Repairs Chemicals Apparatus And Glasswares Crm Materials Under Jal Jeevan Mission For Pwd Goa. Submission Date for this Tender is 22-12-2021. Chemical Supply Tenders in LABORATORY Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Dec-2021 | LAST DATE OF APPLICATION | Date | 22-12-2021 |
Sl. No. | Item Description |
1 | Autoclave Single Lever Fully Automatic Make : Shall be as per the approved list at Annexure B. (a) Model No. : #7440 SLEFA Technical Specifications: Working Chamber Size (Ø x D) : 400 x 600 mm Capacity : 91/75 L Carrier (Ø x D) : 1 of 400 x 600 mm Gross Dimension :970 x 720 x 1290 mm /97 kg, CE Certified, Unique single lever lock for lid with single hand opening.Microprocessor Based Control ensures repeatability & a high accuracy. Low water detection. Spring loaded safety valve for over pressure.Pressure interlock on door.Over temperature safety with independent alarm Fully automatic with LCD Controller cum timer |
2 | Conductivity meter/TDS - Make: Shall be as per the approved list at Annexure B. Model no: ECCON70043S HSN code: 9027Eutech CON 700 Meter With Conductivity/ATC Probe (CONSEN9501D), Integral Electrode Holder & 100/240 VAC AdapterProduct Features Ready indicator let you know when readings are stable. Selectable cell constant Auto-ranging across 5 Conductivity and TDS range. Up to 5-point push button calibration Non-volatile memory holds up to 100 data points Integral electrode holder BUFFER SOLUTIONS Conductivity Standard 1.30Microsiemens/cm @25°C ,Pack Size: 250ml |
3 | Turbidity meter- Make :Shall be as per the approved list at Annexure B. Model : 335 HSN CODE: 90273090 Digital Turbidity Meter 31/2 digit LED display, Range 0-1000 NTU/JTU available in 4 ranges, 0-2, 0-20, 0-200, 0-1000 NTU/JTU. 230V AC 50 Hz (Table Model).3 1/2 Digit 7-Segment LED Display Resolution 0.01 NTU Accuracy + 3% FS, +1 Digit,DetectorPhotodiode Sample System 60 x 25mm Clear Glass Test Tubes Power 230 V + 10% AC, 50 Hz Dimensions245 x 260 x 125 mm (L x B x H) (Approx.) Accessories Test tube Set of 5 |
4 | pH meter - Make : Shall be as per the approved list at Annexure B.Model No. : ECPH70042GS . Product Features :pH meter with glass body, open pore pH electrode,Probe PH5TEMB01P, integral electrode holderand 100/240 VAC Adapter Large, easy-to-read display . |
5 | Spectrophotometer- Make :Shall be as per the approved list at Annexure B. Model No. : LMSP-UV1900 HSN code: 9027,Cell Holder-10mm 8cell Programable cell holder,Bandwidth - 0.5 /1.0/2.0/4.0 nm Variable,Optical SystemDouble Beam, Grating 1200 lines / mm, Wavelength Range-190 - 1100nm,Wavelength Accuracy - +0.3nm,Wavelength Repeatability +0.2nm,Scanning Speed - Fast, Medium & Low,Photometric Accuracy+0.3%T,Photometric Repeatability +0.2%T Photometric Range - 0.3-3A,0-200%T,0-9999C,Stability - + 0.001A/h @ 500nm,Baseline Flatness & Noise+0.001AStray Light-<0.05%T @ 220nm,360nmStray Light<0.05%T @ 220nm,360nm,Data Output Port -USB,Display320 x 240 Graphic LCD,LampsDeuterium Lamp & Tungsten Halogen Lamp,Detector Silicon Photodiode,Power Supply AC 220V/50Hz |
6 | Laminar Air flow - Make : Shall be as per the approved list at Annexure B.Size4" x 2" x 2" GI Powder Coated,Perforated stainless steel diffuser screen protects the HEPA filter and maintains uniform airflow velocity within the work area. Filters: Aluminum framed High efficiencyParticulate air (HEPA) EU 13 filter, with a minimum efficiency of 99.99% at 0.3 micron.Pre filter: Washable type pleated pre-filter with 90% efficiency.Digital Screen Displaying: Filter usage time, UV Lamp usage time, UV Hour Meter and Air Pressure. |
7 | Magnetic stirrer -Make: Shall be as per the approved list at Annexure B.Model no: 2MLH, 1200 rpm |
8 | Bacteriological Incubator - (Laboratory Type With Digital Temp Controller)Chamber Size -60 X 60 x 60Cms ,No of Shelves-4 Nos. Double walled construction inner chamber made ofStainless Steel 304Q & exterior G.I. sheets powder coated. The gap between the two walls filled with glass wool insulation. Inner glass door & exterior metal door with magnetic gasket & lock. Temperature Controlled by Microprocessor based Auto tune PID digital temperature controller with PT 100 as sensor Temperature Range:5°C above ambeint to 60°C. accuracy +/- 0.5°C. Supplied with G.I. wire mesh shelves. |
9 | Refrigerator -Make: Shall be as per the approved list at Annexure B.Double door LG or Samsung.Capacity (ltrs): 300. Temperature range: 1°C to 10°C.Controller : Electronic.Recommended stabilizer: VS-02 |
10 | Jar test Apparatus - Make :Shall be as per the approved list at Annexure B.Model : BTI-15.Variable speed 50-150 RPM electric motor with gear chain for uniform speed in all multiple spindle stirrer and fluorescent tube for 1 Ltr beaker supplied without glass parts. Features -Type : Floculator Jar Test Apparatus,Jar Capacity (ml) :1 Ltr,Display :Digital RPM Display,No. Of Stirrer : 4 Stirrer,Stirrer Speed (RPM): 50-150 RPM with digital rpm indicator . |
11 | Heater - Make :Shall be as per the approved list at Annexure B.Model No. : BTI -23, Size in inches : 18"" X 24 "" ,Rating K.W. : 3K.W.,Top made of cast iron material & body made of mild steel powder coated with nichrome wire heater & grooves plate to get uniform temperature on plate. Max surface temp 350 °C. Temp. Controlled by thermostatic. |
12 | Analytical Balance - Make : Shall be as per the approved list at Annexure B.Model No . : AUX220.Specifications-Capacity220g,Readability0.1 mg,Pan Size(mm) 80 dia approx. Linearity ± 0.2 mg. Repeatability= 0.1 mg.Response Time 3 seconds.Calibration-Internal,Tare Range 1100ct (by subtraction),Operating Temperature 5 to 40 °C,Housing Dimension 220W X 330D X 310H (mm)approx. Power Supply DC 12V, 1A. Manufacturing Calibration Certificate Required NABL Lab |
13 | BOD Incubator - Make : Shall be as per the approved list at Annexure B. Model No. : MSI-9. Chamber Size in cms :60X 60 X 90 cms.Capacity: 12Cu ft 330 ltr. Double walled construction inner chamber made of Stainless Steel 304Q & exterior made of G.I. sheets powder coated. The gap betweenthe two walls filled with glass wool insulation. Cooling is by hermetically sealed compressors with CFC free refrigerant. Temperature Controlled by Microprocessor based Auto tune PID digital temperature controller with PT 100 as sensor. Temperature Range: 5°C to 60°C accuracy +/- 0.5°C Suppliedwith S.S. Rod shelves.Temperature Resolution : 0.1°C,Control Accuracy: +0.5°C |
14 | Hot Air Oven - (Laboratory type with digital temp controller ) HSN code: 85141000.Make : Shall be as per the approved list at Annexure B. Model NO. : M.S.I. 5. Chamber Size -45 x 45 x 60 Cms Rating2500W. No of Shelves4 Nos. Construction: Double walled construction inner chamber made of Stainless Steel 304Q & exterior made of G.I. sheets powder coated. The Gap between the two walls filled with glass wool insulation. Temperature controlled by microprocessor based auto tune PID digital temperature controller with PT 100 as sensor. Temperature range: 50°C to 205°Caccuracy(± 2°C). Supplied with G.I. wire mesh shelves. 3shelves . IncludingSilicon Gasket.Temperature Range: 50oC to 250oC. Temperature Resolution: 0.1oC. Control Accuracy: +/-2oC |
15 | Computer - Ideacentre 320 Celeron Dual Core (4 GB DDR4/1 TB/Free DOS/19.5 Inch Screen/AIO 330 20IGM) With the Lenovo IdeaCentre AIO 330, set up a work or entertainment corner in your home or workplace. This personal computer features a 49.53 cm (19.5) HD Display, 4 GB of DDR4 memory, and the Intel Celeron J4005 Processor for fast and effortless performance. |
16 | Water still - |
17 | Make : Shall be as per the approved list at Annexure B.Model No. : #7655M,Capacity 4L/hr. Dimension : 550 x 460 x 370 mm.Heater : 3.0kW. Specification: Distil water, free from dissolved salts,clear, odourless and tasteless water. Advantages:- Thermostatic cut-off (self resetting type) for assured low water detection - with visual indication. Unique water level maintaining device improves efficiency. Compact & user friendly space saving design - occupies less space & can be table or wall mounted. Easily openable Boiling Chamber as well as Condenser for easy cleaning. Fully stainless steel. |
18 | Water Bath with Digital Temperature Control - Model no: M.S.I. 17 B,Make: Shall be as per the approved list at Annexure B. Complete S.S model.HSN Code: 84191920.Technical Specifications: Size 356 x 250 x 100 mm,Rating watts1500,No. of holes12 Holes,Double walled in construction Fullymade ofStain less steel S S Inner Mirror Exterior Mat Finished. The gap between the inner and outer chamber filled with glass wool insulation to minimize heat loss. Immersion type Heater should be provided. Microprocessor BASED Auto Tune PID digital Temperature. Controller with PT 100 AS SENDOR Lid made of Satinless Steel 304Q with 12 Holes of 3"" diameter |
19 | Filtration Assembly - MAKE : Shall be as per the approved list at Annexure B. Model No. : I-192M .Applications :High product recovery under negative pressure for superfine filtration. Includes :Filter Funnel Glass with SS 304with externalSS Clamp.Membrane Filter C. N. 47 mm/0.45 µm pack of 100.Vacuum Flask one litre. Vacuum pump diaphragm type-oil free.Air vent filter- Hydrophobic PTFE 50 mm/ 0.2 µm with needle . Flexible Silicon Tubing 1 mtr..Plastic Tweezers (Forceps) |
20 | FUME HOOD G.I. Powder Coated - Make :Shall be as per the approved list at Annexure B. Model No. :LSI - FH-04. Laboratory Fume Hood (4 feet).AutoBypass, Standard .Fume Hood : Outer G.I powder Coated and Inside PP lining with FRP BakelitePenolic Sheets. External Size:- 1200mm L x 1000mm W x 2400mm H (approx). Internal Size:-720mm L x 750mm W x 1150mm H (approx). a)ChemicalStorage Base Cabinet(4 Feet) 1.2 Mtr(approx). b)Centrifugal Blower (1 HP) .c)PVCDucting Charges 6"Dia (150mm).Airflow monitor (Digital) |
21 | Research Centrifuge - Make : Shall be as per the approved list at Annexure B. Model No : R- 23.Stepless speed regulator with zero start interlock. Digital speed indicator. Dynamic brake. 0-99 minutes digital count down timer. Imbalance detector with cutoff. Safety lid interlock to prevent cover opening during centrifugation. Technical Data - Max Speedrpm6900. Max. RCF "g"7350. Max. Tube size ml200 . Max. Capacityml1200. W x D x H mm 400 x 500 x 4555. |
22 | Printer - Brother DCP-T220 Multi-Function Inktank Printer.Inktank Printer with scanner facility . Make: Shall be as per the approved list at Annexure B. |
23 | COD - Make :Shall be as per the approved list at Annexure B. Model : BTI-12.Digital COD Digestor is suitable for COD method formonitoring waste water influent and effluent, industrial process water and more. This instrument is used by Pollution control Labs. Features -Aluminum Block with holes (Dimension 40 mm dia x 80 mm depth) is used to hold 15 nos. tubes. COD tubesAluminum block is heated to maintain temperature up to 180 °C . Solid state digital temperature controller, appropriate heater &insulation selection assure uniformity in all the samples. Selectable time up to 120 min with alarm is provided to set the digestion period (Refluxing). Product Details:Display -Digital. Material- Mild Steel, Sample Volume - 20.ml. Capacity -15 samples.Max Temperature -180 deg. C.Wall Type Double Walled. Accuracy+/- 1% |
24 | Pen Digital Thermometer - Make : Shall be as per the approved list at Annexure B.Model No : DT-2.HSN Code : 9025.Features :10 Min. Auto Shut Off ,Min. 250 mm stainless Stel Sensor probe, Temperature Unit ?F/?C Selectable. Data Hold .1 Sec. Normal Tempearture Sensing Time .Specification: Basic Funstion - Range ,Temperature 300?C (-58?F ~572?F)Acurracy ±1 ? C(±1.8? F)Resolution1?C/?f |
25 | DO Meter - DISSOLVED OXYGEN BENCH METERMake: Shall be as per the approved list at Annexure B. Model no:ECDO70042S. Dissolved Oxygen Bench Meter. Self-stirring probe and bi-directional RS232– ideal for BOD and other Dissolved Oxygen applications in the laboratory. Measures Dissolved Oxygen in % saturation, ppm, mg/L at ±0.5 % full scale accuracy.Automatic calibration at 100 % and independent 0 % –greater measurement sensitivity during low oxygen levels. Accurate readings in varying conditions with Temperature, Salinity and Barometric Pressure Compensation.Auto-logging function for convenient continuous monitoring. Limit alarm alerts when reading falls out of range. Password protection for setup and calibration. Specifications- Dissolved - Oxygen, Range- 0 to 30 mg/L,Resolution- 0.01 mg/L, Accuracy ±0.5 % full scale, % Saturation Of Oxygen , Range0 to 199.9 % ; 300 % , Resolution0.10%, Accuracy ±0.5 % full scale, Salinity Correction.Range0 to 50 ppt,Resolution 0.1 ppt, Barometric Pressure Correction. Range450 to 825 mmHg (manual) Resolution 1 mm Hg,TypeManual input.Method -Auto correction with manual input.Temperature Range 0.0 to 50.0 ºC / 32.0 to 122.0 ºF. Resolution0.1 ºC / 0.1 ºF. Power Requirements-9 V DC adapter, 1.3 A (100/240 VAC, SMPS). |
26 | Digital Thermo Hygrometer - Make: Shall be as per the approved list at Annexure B. NABL Laboratory Calibrated |
27 | Acid Bottle Top Dispenser - Make :Shall be as per the approved list at Annexure B. Cat. No. : 051195, Capacity : 20-100 ml, Packing : 1 |
28 | Exhaust Fan - Make : Shall be as per the approved list at Annexure B. Model No.: DX 200mm . Specification : Power SourceCorded Electric, Included Components1 N Exhaust fan. Brand Havells, Mounting Type Wall Mount,ColourWhite ,Item Dimensions LxWxH 62.5 x 35.2 x 38.3 Centimeters,Material Plastic , Controller Type Button Control. |
29 | Color comparator Make : Shall be as per the approved list at Annexure B. |
30 | Std. weight box - Make : Shall be as per the approved list at Annexure B.Model No. : Class F1,Specification:- Class : F1 / E2, Material : 304 Stainless Steel.Shape : Cylindrical with knob. Finish : Mirror Polish.Packing : Alumuinum Alloy / wooden Box. Accessories : Tweezer, Cloth, Gloves |
31 | Distillation unit - MAKE : Shall be as per the approved list at Annexure B. MODELNO. : BASIC/PH4-S (SINGLE) Specification : Water Stil - Basic.The Still Provides 4 liters / hour of Distilled water produced through a power in put of 3KW. Dimensions : (WX DX H). PH4 : 50cm x 15cm x 45cm. Weight : 6 kg. Approx.Power : 220/240v , 50/60 Hz. single phase. 3KW Heater. Water Supply : Min. Flow rate 1 litre/min. Min. pressure : 3 p.s.i. (0.2 x 105 NM-2) Features:-The still provides, 4 litres/hr of distilled water produced through a power input of 3KW by a chromium plated heater housed in a horizontal Glass Boiler . Producing pyrogen free water. Construction The stand is powder coated for long rust free Operation. All plumbing connections to the equipment are made. |
32 | Split AC - Make :Shall be as per the approved list at Annexure B. Inverter Type Split AC. Capacity:2 Ton, Star Rating : 4 Star, Type :Split, Condenser : Coil Copper. General Model-2 Ton 4 Star ,Model Name AR24AY4YATZ, TypeSplit, Capacity 2 Ton, Star Rating 4 Star, Colours White, Cooling Capacity6000 W, CompressorDigital Inverter Compressor, Dehumidification Yes, Condenser CoilCopper, Remote Control Yes |
33 | 30 KVA UPS - Make -Shall be as per the approved list at Annexure B. 3 X 3, 30 kVA, 3 Phase, 6Pulse, 415 V, Hipulse-U, 0.9 PF, UPS. 42AH – 12V SMF. Batteries to provide 10-15 min backup. Batteries & UPS to battery ban. |
34 | HPLC - Liquid Chromatograph ( HPLC).MAKE : Shall be as per the approved list at Annexure B. Model NO.: LC-2030C NTP Series or equivalent model in approved make. System specification as follows:A) SOLVENT MANAGER:- 1. Pump: Quaternary,Gradient with Flow rate range 0.01 to 10 ml/min or better. 2. Number of Solvents: up to four. 3. Auto injector: 120 vial capacity auto injector (Injection Volume 0.1- 100pl). 4. Column Oven: with two ports. 5. Column Temp:Ambient minus 15°C or 4°C (whichever is greatest) upto 65°C. 6. Built in degassing system with thermo setting temperature up to 50 deg C. 7. Flow rate precision of +0.1% RSD with flow accuracy of -L5%. 8. Itshouldincludeanautomatedsoftwareassistedpurgefunctionforeaseofsolvent changing and system purging/priming. 9.Operating pressures range up to 6000 PSI for entire flow-rate range. 10.Needle wash system that uses fresh solvent with before and after each injection. 11.Random access to any vial for multi-method operation.12.Should have the facility of repeated injections per vial. B) AUTO-SAMPLER: 1. Interchangeablevialstraysofminimum50withvialcapacityrangingfrom1-4ml along with caps and septa. 2. Temp: - 4 deg Centigrade to Ambient with thermostat. C) PHOTODIODEARRAY DETECTOR(PDA): 1.Noise level: 1 0.6 x 10-5 AU/H. 2.WavelengthRange: 190-700 nm or better. 3.Wavelength accuracy should be + 1nm or better. |
35 | D) COMPUTER& LICENSED HPLC SOFTWARE: 1. The system should support a chromatography software package compatible with latestversion of Windows. 2. The HPLC system software must be able to perform completeinstrumentcontrol, data acquisition, data evaluation,automationand reporting.. 3. The HPLCsystem control software must be qualified for use in a GLP/GMPcompliant environment.The vendofmUst be able to provide instrumentperfection certificateandOperation Certificate. 4. The software should be able to store the analysed files |
36 | 5. Branded Computer system: Intel core i5 processor,minimum 4 GB RAM, 500 GB hard disk,DVDwriterdriver, 21“LEDmonitor, USBportsfordatastorage, Licensed Windows 7 operating system, connectivity of computer and printer directly to instrument or latest computer specification. 6. Compatible ink-Jet Printer. E) COLUMNS: a)250 x 4.6 mm 5 micron ODS(C 18)1.b)250 X 4.6 Mm 5 micron (C 8) 1. c)Silica Column 250 x 4.6 mm 5 micron 1, d)150 X 3.9 mm 5 micron (C 18).1, e)150 K 3.9 mm 5 micron (C 8).1, f} Guard Column C8 and C18 4 each. F) CRITICAL SPARES REQUIRED TO BE INCLUDED. G) UNINTERRUPTED POWER SUPPLY (UPS): SystemwithSMFBatterywithminimum1hourpowerback-upfor computer 1. H) TRAINING AND ANALYSIS:- 1. The traininghasto be impartedto theLaboratOryStaffwithcompleteoperationalprocedures, safety precautions, troubleshooting etc. 2. A well trained and dedicated Analyst has to be deployed at the laboratoryfor performingroutinetestsalong with Laboratorystaffsothatstaffgetshand on experience after trainingfor using HPLC. 3. The Analyst has tobe deployed forminimum period of 1 year. Further can be extended onchargeable basis. |
37 | Rotary Vacuum evaporator |
38 | MAKE : Shall be as per the approved list at Annexure B.Model NO.: 8763.RV0.000 (Vertical) Advanced touchscreen interface allows quick & easy control of all process parameters. Reversible direction for uniform evaporation. Instant adjustment of rotation speed (20-280 rpm) with Magic Knob. Inbuilt comprehensivesolvent library. Bath range upto 200 deg. C with capacityupto 3/ 5 L“evaporatingflask suppliedwith standard 1L pear shaped evaporating and round bottom, receiving flasks. PTFE feed tube and feed stop cock. 1. IQ/OQ/PQ of the system is required. 2.Free of cost installation, demo and training to be provided on site. 3.Minimumperiod of TwoyearWarrantyfromthe dateofinstallationandThreeyears comprehensive AMC after expiry of warranty period. 4.All other spares, consumablesand accessories required for operation should be madeavailable for at least Ten years. 5.Nomenclatures/Units should be followed as per specification in compliance chart. |
39 | Kjeldalh Distillation Assembly-MAKE : Shall be as per the approved list at Annexure B. Model NO. 16.540. KJELDHAL APPARATUSUniversal Combined Kjeldhal Digestion and Distillation Unit .Electrically heated, comprising of one single mild steel tubular stand provided with two shelves one abovethe other. A specially designed glass fume duct wit 24/29. Cone openings (suitable for flasks having 24/29 socket) having such provision so that no leakage of fumes takes place. One heater box having individual energy regulators for 500 watts heaters are supplied in digestion part at the lower side. One heater box of above design is supplied in distillation part at the upper side. Distillation part is also provided with brass condenser rack with water circulationsystems and clamps. The whole unit is operated on 220 volts ACmains. |
40 | B. Repairing of the OldInstruments and Euipments |
41 | Autoclave Make: - Model No.: , Serial No.: I.Replacement of Heater, II. Replacement of Temperature Controller .III.Replacement of SSR relay .ivReplacement of Pressure Gauge . |
42 | Conductivity meter/TDS - Make: Eutech, Model No.:CON 700, Serial No.: - ,Make: Elico,Model No.:CM180, Serial No.: , Repalcement of Display, Repalcement of Electrode |
43 | Turbidity meter - Make: Hach ,Model No.: 2100 P , Serial No.: 030300030156,ReplacementofDisplay Board ,Make: Hach ,Model No.: 2100 P Serial No.: 46500-00 |
44 | pH meter - Make: Hach ,Model No.: -, Serial No.: Replacement of Board - Make: Elico ,Model No.:LI 120,Serial No.: Replacement of pH Electrode |
45 | Spectrophotometer- Replacement of Display ,Make:Hach ,Model No.:DR 5000, Serial No.: 1357473, Replacement ofAlinement of Beam ,Replacement ofCords Cubetts |
46 | Laminar Air flow - Replacement of VV ,Make: BTI, Model No.: 4X2 , Servicing of tube . |
47 | Bacteriological Incubator - Replacement of Motor , Make: BTI, Model No.: Serial No.: Replacement of Blower Motor |
48 | Refrigerator - Replacement of CompressorMake: -,Model No.: -,Serial No.: . |
49 | Jar test Apparatus - Replacement of Motor , Replacement of PCB bord for RPM |
50 | Analytical Balance - Servicing of Flucktuation( Calibration ),Make: Citizen.Model No.: Serial No.: . Repalcement of Load Cell Make: Model No.:AF 160.Serial No.: |
51 | BOD Incubator -Replacement of Motor ,Make : Bharat |
52 | Hot Air Oven - Replacement of SSR Relay , Make: Tempo,Model No.:TI-90A, Serial No.:646. Replacement of HeaterMake: Shivam Instruments Model No.:TI-90A.Serial No.:646,Replacement of Thermostate - Make: Quality, Model No.:QBI-902, Serial No.: QBI -05. Replacement of Controlling System .Make: Jindal.Model No.: . Serial NO.:. Replacement of Heater Make: Quality Model No.: Serial NO.: . Replacement of Motor Make: Quality,Model No.: ,Serial NO.: |
53 | Water still - Replacement of Heater ,Make: BTI, Model No.: , Serial NO.: ,Replacement of Thermostate |
54 | Water Bath - Replacement of Heater -Make: BTI,Model No.: -Serial NO.: |
55 | Printer- Repairing of Printer |
56 | DO Meter - Repairing of DO meter |
57 | Exhaust Fan - Repairing of Motor |
58 | Split AC - Repairing of compresor ,Repairing of blower ,Repairing of condensor ,Repairing of Filter |
59 | C. Requirement for list of chemicals |
60 | Hydrochloric acid AR |
61 | Potassium chloro platinate |
62 | Cobaltous chloride |
63 | Hexamethylene Tetramine AR |
64 | Hydrogen peroxide Soln 30% |
65 | Potassium chloride |
66 | Buffer capsules(4.0) |
67 | Buffer capsules(7.0) |
68 | Buffer capsules(9.2) |
69 | Acetone AR |
70 | Eriochrome black T AR |
71 | Ammonia Solution AR |
72 | Magnesium chloride hexahydrate AR |
73 | Ethylene Diamine Tetra Acetic acid di sodium salt |
74 | Sodium hydroxide AR |
75 | Potassium chromate AR |
76 | Silver nitrate AR |
77 | Methyl orange |
78 | Sulphuric acid 25% AR |
79 | Potassium hydrogen phthalate |
80 | Iso Propyl alcohol AR |
81 | Ethanol |
82 | anhydrous sodium sulphate AR |
83 | Sodium acetate Anhy AR |
84 | Potassium nitrate AR |
85 | Magnesium chloride AR |
86 | Hydroxyl amine hydrochloride AR |
87 | Ammonium acetate AR |
88 | Glacial acetic acid AR |
89 | 1:10 phenonthroline monohydrate AR |
90 | Nitric acid AR 69-71% CONC. |
91 | Ammonium Per sulphate AR |
92 | Silver Sulphate AR |
93 | Potassium iodide AR |
94 | Potassium oxalate AR |
95 | Magnesium Sulphate anhydrous |
96 | Calcium chloride anhydrous |
97 | Ferric Chloride Anhy AR |
98 | Chloroform AR |
99 | Sodium azide AR |
100 | Manganese (II) sulphate AR |
101 | Potassium sodium tartarate AR |
102 | Aluminium potassium sulphate AR |
103 | Lactose Broth (Hi media) |
104 | Sodium hydrogen carbonate AR |
105 | N-Amyl alcohol AR |
106 | Ascorbic acid AR |
107 | Eriochrome cyanin R |
108 | Sodium floride AR |
109 | SPADNS AR |
110 | Zirconyl oxy chloride |
111 | Sodium arsenite AR |
112 | Sodium Hydrogen sulfite |
113 | Mercuric sulphate AR |
114 | Orthophosphoric acid (85%)AR |
115 | Potassium permanganate AR |
116 | Sodium oxalate AR |
117 | Manganese metal Powder |
118 | Ferrous Ammonium sulfate AR |
119 | Electrolytic Iron Powder |
120 | Ammonium Chloride AR |
121 | Sodium chloride AR |
122 | Methyl red indicator AR |
123 | Huydrazine sulphate AR |
124 | Ammonium purpurate murexide AR |
125 | Sodium carbonate Anhydrous AR |
126 | Glycerol AR |
127 | Barium chloride Dihydrate AR |
128 | Sodium thiosulphate AR |
129 | Starch (potato) |
130 | Potassium dichromate AR |
131 | Ferroin indicator Soln AR |
132 | Platanium Loop |
133 | Potassium dihydrogen phosphate AR |
134 | Petroleum ether AR |
135 | Bromocresol purple |
136 | Tryptone Broth |
137 | Calcium chloride (fused) |
138 | P-dimethyl amino benzaldehyde AR |
139 | Mercuric iodide Red AR |
140 | Sodium dihydrogen phosphate(Dihydrate)AR |
141 | Borax AR |
142 | Potassium hydrogen tartrate |
143 | Potassium tetraoxalate dihydrate |
144 | Aluminium ammonium sulphate dodecahydrate |
145 | Hydrogen peroxide (30%)AR |
146 | Phonolphthalein |
147 | Poassium periodate |
148 | Potassium hydroxide pellets AR |
149 | Calcium carbonate anhydrous |
150 | Zinc Sulphate heptahydrate |
151 | Aluminium Metal Powder |
152 | Solchrome Cyanin R |
153 | Sodium hydrogen sulfite |
154 | Pepton Water |
155 | Conc. Ammonium Hydroxide |
156 | Dipotassium hydrogen phosphate |
157 | Disodium hydrogen phosphate anhydrous |
158 | Potash Alum |
159 | Sodium fluoride anhydrous |
160 | 1,2 cyclohexylene diamine tetra acetic acid |
161 | Lauryl tryptose broth, m080 |
162 | Brilliant green Lactose bile broth m121i |
163 | Gutzeit apparatus for arsenic determination. |
164 | M-Endo Agar, m029 |
165 | Nutrient Agar |
166 | Phenol Red |
167 | Sodium iodide |
168 | sodium nitrite |
169 | Salicyclic Acid |
170 | O-toluidine powder |
171 | EDTA mg salt |
172 | Ammonium Molybdate |
173 | Sucrose |
174 | Silicon Oil |
175 | filter paper (whatmann 41) |
176 | filter paper (whatmann 40) |
177 | Non absorbent cotton wool |
178 | Sodium sulphate |
179 | Potassium Sulphate |
180 | Boric Acid |
181 | White phenol |
182 | Ringer powder |
183 | Oxalic Acid |
184 | Phthalic acid |
185 | Methanal |
186 | Conc. Sulphuric Acid |
187 | MC Conckey broth purple |
188 | Pesticide standard suitable for Gas Chromatography (multi component solution ) Analytical standard |
189 | Organic solvent suitable for dilution of pesticide standard |
190 | Iron Standard solution for AAS |
191 | n-Hexane GC/HPLC |
192 | Dichloromethane GC/HPLC |
193 | Nitrile gloves of reputed make , Kimberly or eq |
194 | Half face Respiratory Mask for safeguarding against organic vapors with cartridge gas filter Venus or 3M make |
195 | Lab Coat |
196 | First Aid Kit- bandages, tweezers, sterilizing wipes, sterile dressings, gauze, antiseptic cream, scissors, and eye dressings |
197 | Zinc Sulphate Hepta Hydrate |
198 | Nesslers Reagent B |
199 | Rochelle Salt (Potassium sodium tartrate tetra hydrate) |
200 | Lamp for UVSpectrophotometer HACH DR 5000 / MERCK |
201 | Hollow Cathode Lamp for Iron analysis on AAS |
202 | Hollow Cathode Lamp for Mercury analysis on AAS |
203 | Hollow Cathode Lamp for Lead analysis on AAS |
204 | Hollow Cathode Lamp for Arsenic analysis on AAS |
205 | Hollow Cathode Lamp for Cadmium analysis on AAS |
206 | Standard solution of IRON in Nitric Acid for analysis on AAS |
207 | Standard solution of MERCURY in Nitric Acid for analysis on AAS |
208 | Standard solution of LEAD in Nitric Acid for analysis on AAS |
209 | Standard solution of ARSENIC in Nitric Acid for analysis on AAS |
210 | Standard solution of CADMIUM in Nitric Acid for analysis on AAS |
211 | Acetylene Gas for laboratory analysis |
212 | Zero Grade Air for laboratory analysis in Rented Cylinders |
213 | Helium Gas for laboratory analysis in rented cylinders |
214 | Nitrogen Gas for laboratory analysis in rented cylinders |
215 | Water GC grade ASTM type 1 |
216 | Refurbishment of Card reader for PC connected to Gas Chromatograph |
217 | Refurbishment of AAS gas control Board |
218 | Replacement of Regulators connected for Gases for GC and AAS |
219 | Replacement of filters and Gas Station manifold for GC |
220 | Supply of Capillary column with suitable Adapters for GC |
221 | D. Requirement for list of Glassware |
222 | Nessler Cylinder (Class"A) 50ml |
223 | Duraporemembrane filters paper 47mm, 0.45um |
224 | Mohr Pipette (Class "A") |
225 | a) 5ml |
226 | b) 10ml |
227 | c) 1ml |
228 | Bulb pipette ("A") |
229 | a) 5ml |
230 | b) 10ml |
231 | Burette (Class "A") |
232 | a) 25ml |
233 | b) 50ml |
234 | Gooch crucible - 30 ml capacity with 30 mm disc dia. |
235 | Measuring cylinders (Class"A") |
236 | a) 10ml |
237 | b) 50ml |
238 | c) 100ml |
239 | d) 250ml |
240 | e) 1000ml |
241 | Spatula (Steel) one end spoon, one end flat 8" |
242 | Beaker |
243 | a) 50ml |
244 | b) 100ml |
245 | c) 500ml |
246 | d) 1000ml |
247 | e)250ml |
248 | Glass fibre filter disc - GF/C 2.1 cm |
249 | Paper - Acid washed, ashless hard filter finish; filterpaper sufficiently retentive for fine particles (Pore size 2-2.5um equivalent to whatman filter No. 542.) 12.5cm |
250 | Sintered disc - Crucible 30ml Grade :5 |
251 | Narrow mouth bottle pp, 125ml |
252 | Glass rod 7x255mm |
253 | Funnel bigger size a) 100mm |
254 | b)75mm |
255 | c)50mm |
256 | Petridish (80x17mm) |
257 | Test Tubes (18x150)w/o rim |
258 | Test Tubes (15x150)w/o rim |
259 | Test tubes with rim (18x150) |
260 | Test tubes with rim (15x150) |
261 | Volumetric flask (Class "A") |
262 | 50ml |
263 | 100ml |
264 | 1000ml |
265 | 250ml |
266 | 500ml |
267 | Aluminium racks (Test Tubes) |
268 | Durham"s tubes |
269 | Burette stand |
270 | Plastic wash bottles - 500ml |
271 | Plastic wash bottles - 100ml |
272 | B.O.D Bottles - 300ml |
273 | Evaporating dish - 50ml |
274 | Silica Evaporating dish (bigger size) |
275 | Watch glass |
276 | 60mm |
277 | 70mm |
278 | 80mm |
279 | 100mm |
280 | Dessicator pp with psf material |
281 | Pipette "A" Mohr |
282 | 25ml |
283 | 50ml |
284 | 10ml |
285 | 5ml |
286 | Bulb pipette (A) |
287 | 25ml |
288 | 1ml |
289 | 50ml |
290 | Beaker |
291 | 2000ml |
292 | 3000ml |
293 | Std. Reagent bottles (250ml) |
294 | Std. Reagent bottles (500ml) |
295 | Std. Reagent bottles (100ml) |
296 | Std. Reagent bottle brown (100ml) |
297 | Std. Reagent bottle brown (250ml) |
298 | Std. Reagent bottle brown (500ml) |
299 | Std. Reagent bottle brown(1000ml) |
300 | P Glass beads |
301 | Cap for tube |
302 | 18x150 |
303 | 15x150 |
304 | Conical flask |
305 | 100ml |
306 | 250ml |
307 | 500ml |
308 | Test tube racks 24 tubes |
309 | Polyethylane bottle - 100ml, 50ml |
310 | Polyethylane measuring cylinders |
311 | 10ml |
312 | 50ml |
313 | 100ml |
314 | 1000ml |
315 | Polyethylane beakers |
316 | 100ml |
317 | 500ml |
318 | 1000ml |
319 | Glass rod |
320 | Pipette "B" class |
321 | 1ml |
322 | 5ml |
323 | 10ml |
324 | 25ml |
325 | Pipette canister |
326 | Test Tubes |
327 | 25x200(w/o rim) |
328 | 32x200 (w/o rim) |
329 | Flat bottom flask(round) |
330 | 250ml |
331 | 500ml |
332 | 1000ml |
333 | Burette class"B" |
334 | a) 25ml |
335 | b) 50ml |
336 | Bulb pipette class"B" |
337 | a) 5ml |
338 | b) 10ml |
339 | c) 25ml |
340 | d) 1ml |
341 | e) 50ml |
342 | Volumetric flask class "B" |
343 | a)50ml |
344 | b)100ml |
345 | c)250ml |
346 | d)500ml |
347 | e)1000ml |
348 | Measuring cylinders |
349 | a)10ml |
350 | b)25ml |
351 | c)50ml |
352 | d)100ml |
353 | e)250ml |
354 | f)500ml |
355 | g)1000ml |
356 | Test tube for culture collection |
357 | Reagent bottles with screw caps- a) 500ml |
358 | Sample bottles (food grade plastic)a)250ml |
359 | Wire gauge |
360 | Pair of tongs |
361 | Tripod stand |
362 | Bottle, Ambered with screw cap 250 ml |
363 | Watch Glass |
364 | Bottle, Ambered with screw cap 500 ml |
365 | Test Tube Stand ( small size) |
366 | Test Tube Stand ( Big size) |
367 | Plastic Beakers ( 100ml) |
368 | Plastic Beakers ( 500ml) |
369 | Plastic Beakers ( 1000ml) |
370 | Plastic measuring Cylinder (10ml) |
371 | Plastic Dropper Bottle (100ml) |
372 | Plastic Plain Bottle ( 100ml) |
373 | Glass Dropper |
374 | Petri Dishes |
375 | Wash Bottles |
376 | Wire Brush |
377 | Pippette Rubber Bulb |
378 | Spirit Lamp |
379 | Glass Beadpkt |
380 | E. Requirement for list of CRM Chemicals |
381 | Ph Buffers 4.0- 3sets of 500ml each |
382 | Ph Buffers 70- 3sets of 500ml each |
383 | Ph Buffers 9.2- 3sets of 250ml each |
384 | TurbidityStandardFormazin 100 NTU- 3sets of 500ml each |
385 | KCL 1M - 3sets of 500ml each |
386 | Sodium Chloride - 3sets of 45g each |
387 | Calcium Carbonate - 3sets of 20g each |
388 | Sodium Carbonate- 3sets of 45g each |
389 | Calcium Standard Solution - 3sets of 100ml each |
390 | Platinium Cobalt Color Reference Solution 500HU - 5sets of 100ml each |
391 | standard weights 0.0002 to 200g set |
392 | Wet and dry thermometer |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy