| 1 | Earth workEarth work earth work in excavation by manual means in formation trenches (not exceeding 1.5m in width as well as 10sqm on plan) including dressing of sides and ramming of bottoms lift upto 1.5m including getting out of excavated soil as direced upto 50 mtr for all kind of soils(manually) |
| 2 | Filling available excated earth (excluding rock) in trenches plinths sides of foundation extra in layers not exceeding 20 cm in depth, consolidate each deposited layer by ramming and watering, lead upto 50 mtr and lift upto 1.5 mtr. |
| 3 | supplying and stacking at site good earth.Distance upto 5 km |
| 4 | supplying and filling in plinth with fine sand under floors including watering, ramming, consoildating and dressing complete. |
| 5 | Cement Concrete work providing and laying in postion cment concrete of specified grade including curing but excluding cost of centering and shuttering all work upto plinth level(a) 1:4:8 ( 1 cement :4 coarse sand :8 graded stone crushed aggregate 40mm normal size). |
| 6 | (b) 1:3:6 (1 cement: 3 coarse sand :6 graded stone crushed aggregate 20mm normal size). |
| 7 | Reinforced Cement Concrete reinforced cement concrete work in beams and slats having slop unto floor level -5 including curing but excluding cost of centering, shuttering, finishing and reinforcement. (a) in 1:2:4 (1 cement : 2 cement :4 graded stone crushed aggregate of 20 mm normal size in plinth beam). |
| 8 | (b) in 1:1.5:3 (1 cement: 1.5 cement: 3 graded stone crushed aggregate 20 mm normal size in slab. |
| 9 | Brick work Brick work with come burnt clay (non modular) bricks of class designation 7.5 in super structure including curing in 1:4 (1 cement: 4 coarse sand) cement sand mortar. |
| 10 | Form WorkCentering and shuttering including strutting propping etc and removal of formfor(a) foundations footing, etc |
| 11 | (b) Suspended floors, roofs, slabs, etc(above plinth level) upto floor. |
| 12 | Steel ReinforcementSteel reinforcment for RCC work including straightening, cutting binding placing in position and binding all complete upto plinth level and above with thermomechanically treated bars of grade Fe-500 D or more |
| 13 | Cement Plaster Providing and laying(a) 12mm cement plaster finished with a floating coat of meat cement in 1:4 (1 cement: 4 fine sand) cement mortar. |
| 14 | (b) provind and laying cement plastrer of 15 mm thickness finshed with a floating coat of neat cement in 1:4 (1 cement :4 fine sand) mortar. |
| 15 | Flooring(a) providing and laying cement concrete flooring in 1:5:10 (1 cement: 5 coarse sand :10 graded stone crushed aggregate of 40mm normal size) including consolidation and level all complete.Note:- Thickness upto 6\" = 0.15cm |
| 16 | (b) providing and laying 62mm thick cement concrete flooring with concrete hardener, topping under layer 50mm thick cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone crushed aggreagate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2(1 cement hardener:2 graded stone aggreagate 6mm normal size). Hardening compound mixed @ 2ltr per 50Kg of cement including cost of cement slurry and curing complete |
| 17 | ( c) Kota stone slab flooring 25mm thick over 20mm average thick base laid over and joint with grey cement slurry mixed with pigment to match the shade of slab, including curing, rubbing polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 18 | Supply and Installation of Walls and Ceilings with Puf Panels 80 mm thick with the following specifications: Walls and ceiling shall be made up of 80 mm thick Puf Insulated Panels. The main columns will be made out of R H Steel section of size 122x61x3.60 mm conforming to IS 4923: 1997. MS Base plate of size 250x250x8mm and top plate of size 200x150x8 mm will be welded to the columns. Base plates will be pre drilled with 4 Nos 18 mm dia holes and provided with anchor bolts at the bottom and normal bolts at the top of 16 mm dia. The Puf Panels shall be 80 mm thick with 0.5 mm thick PPGI Sheets on both sides. The Panels shall be manufactured on continuous automatic line with puf density 40 + 2 Kg /Cum. The wall panels will be provided with tongue and groove joint for interlocking. One edge shall have double groove system for better insulation. All the flashings provided shall be made out of 0.50 mm thickness PPGI sheet. The interior and exterior colour of panels shall be RAL 9003 colour. The PUF insulation material in the panel will have fire retarding and self-extinguishing properties.The Puf Panels shall be manufactured using high pressure dispensing machine equipped with PLC Controlled panel for monitoring and controlling the injection rate to assure specified uniform density requirements. Make of the Panels shall be BNAL/Sintex/Alfa. |
| 19 | Supply and Installation of 75 mm thick Extruded Polystyrene (XPS) with the following specifications: The75 mm thick extruded polystyrene rigid insulation board of required size shall be provided in the flooring, complying with ISO 4898:2008 & ASTM C 578- 08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621,density of 34-36 kg/m³ as per ASTM D 1622, water absorptions 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576.Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, complete in all respect as per the direction of Engineer-in-Charge. Makes of the Extruded Polystyrene (XPS) shall be Technonicol/Owen/Texsa. |
| 20 | Chiller door with 80mm thick leaf having both side PPGI sheet with heavy duty Aluminium Frame, hinges and locking device and gaskets size 900 x 2100mm clear opening. |
| 21 | Supply and Installation of Refrigeration machines 3 Ton 3 Phase. Supply and Installation of heating coils 4Kw.Specification :-1 External Room Dimensions (LXWXH) in 7 m 4.68 m 4 m (Meter) 2 Product to be stored Banana3 Product in coming temp. +30 Deg C.4 In coming product quantity 15 Mt per day5 Room Temperature Reqd. +14 to +17 Deg C6 Ambient Temp +43 Deg C7 Pull Down Time 4 - 6 Hrs.8 Other load Light9 Heat Load- BTUH 20000 BTUH10 Wall & Ceiling Panels Insulation 80 mm thick11 Floor Panel Insulation 80 mm Bare Puff Slab12 Internal and front side is PP13 Outside is PPGI14 Door Thickness and finish 60 mm PP/PP Condensing Unit15 Copper pipe length 20 Feet16 Cooling Capacity Kw 7.8 Kw 3 Ph17 Compressor make Emerson18 Ref. Gas R-407a19 No. of condensing unit 8 Nos.Indoor Unit20 Heating Capacity Kw 4 KW21Cooling Capacity Kw7.8 Kw 3 Ph22 Digital Temp. Indicator cum controller |
| 22 | ETHYLENE GAS SENSOR TYPE Digital (Wall Mounted)RANGE 0 - 2000 ppmPOWER SUPPLY 15-24 v DC |
| 23 | CO2 GAS TRANSMITTER TYPE Infrared, Digital (Wall Mounted)MEASURING RANGE 0 – 5%POWER SUPPLY 15 – 24 v DC |
| 24 | AIR CIRCULATION WITH CONTROLLER 1 SET (per room) TYPE Wall MountedFEATURES Fans for exhaust & fresh airControls for 2 Gas SensorsPOWER SUPPLY 220V, 50 HzPROTECTION IP 31 |
| 25 | HUMIDIFIERTYPE Wall MountedDISPENSING UNIT NozzlesINLET WATER PRESSURE 4 Bar minimumPOWER SUPPLY 230 VAC, 3 Amp |
| 26 | ETHYLENE GENERATOR PortableMODEL GENETPOWER SUPPLY 230V, 50 Hz 400WTANK CAPACITY 1 LiterDIMENSIONS 315 X 250 X 350 mmSUPPLIED WITH Genetol Ripening Liquid |
| 27 | AFFF Based 9 kg Mechanical Foam Portable Fire Extinguisher. |
| 28 | M.S. Heavy Duty Platform Trolley. Loading Capacity – 500-800 Kgs. |
| 29 | Electronic weightscale. Measuring capacity of 200Kgs |
| 30 | Crates for banana storage. |
| 31 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 32 | Supplying & Fixing Of Following Sizes Of PVC Conduit Along With Accessoriesin Surface Including Cutting the Wall And Making Good the same In Case of recess Conduit as Required 20mm. |
| 33 | Wiring for light/ power plug with 2 X 4 sq. mm + 1 X 4 sq. mm earth wireFRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 34 | Supplying and fixing following Wall Mountedswitch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 35 | Supplying and fixing following Wall Mountedswitch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch |
| 36 | Supplying and fixing following Wall Mountedswitch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 37 | Supplying and fixing following Wall Mountedswitch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 38 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 39 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 40 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required 6 Module (200mmX75mm) |
| 41 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 42 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 43 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 44 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without 6way (4 +18), Double door |
| 45 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB & DB Shall Be Of Same Make Single pole |
| 46 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB & DB Shall Be Of Same Make Double pole |
| 47 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 48 | 25 mmTotal of the Sub-Head - Mccb, Mcb & Ob\"s : |
| 49 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 50 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 51 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 52 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required. |
| 53 | Supply and commissioningOf LT Power Cable1.1 Kv Grade , 900C rating, heavy duty, XLPE Power cable conforming to following requirement and in line with IS-1554, IS-5831, IS-8130,& IS-3975, XLPE Insulated , Pvc Inner Sheathed (Extruded ) Armoured , FRLS Pvc Outer Sheathed , Stranded Aluminium Conductor Confirming To IS : 7098 Part 1, Armour: galvanised steel strip/ wire as per applicable. Aluminium Armoured Cablesize: 3.5 Core x 35 sqmm |
| 54 | Sub-Head : MV Cable Laying From AMF Panel To Main. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm |
| 55 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.l. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 56 | MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm |
| 57 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 58 | MV SWITCHGEAR PANELS & DISTRIBUTION BOARDS : Design, manufacture, supply, installation, testing and commissioning of following Utility panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dust and vermin proof type compartmentalised design fabricated out of 2mm thick CRCA sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber (form-3b Construction). The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line Diagram. Important Notes: Common for all Switchboard: The BOQ shall be read inconjunction with general notes, specification Incase of any discrepancy between specification, BOQthe same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered.All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C releases.All rating MCCB\"s shall be thermalmagnetic type. Incoming MCCBs shall be provided with O/C,S/C, releases. All feeder doors shall have pad locking arrangement. All TP feeders shall have solid isolable neutral link. All MCCB used in starter feeder shall be suitable for motor duty application. All power contactors including NIC shall be of AC3 duty. All switchgear used in starter feeder shall be type-2co-ordinated. Manufacturer is required to submit manufacturers type-2 co-ordination chart for the make used.All meters are digital type. Panel shall be powder coated of approved shade with minimum 60 micron thickness. Size of Voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded terminal shall be used in the panel.All bus bar shall be insulated with coloured PVC Sleeve i.e.RYB,BK as per colour code. Internal wiring of panel shall be with size 2.5sqmm Flexible Copper Conductor for CT circuit and control wiring with 1.5 sqmm.All indicating light shall be LED type . Supply & Installation Of Main Distribution Board As Described Above. Main Panel With APFC 50 Kvar Heavy Duty. Panel Shall Be As Per IEC 61439 1& 2 Along With Siesmic Zone 5 Compliance. Incommer 1 Nos. 160Amp 25 KA 4P MCCB complete having TMR For over current, short circuit ncomer shall be complete with following. Over Voltage Under Voltage Release. METERING FOR EACH INCOMER Square flush mounting 0-200Amp ammeter with 3 way and OFF selector switch.3 Nos. Cast resin current transformers of Class 1.0 for metering. Three phase indicating lamps (LED type) with MCB. ON OFF TRIP indicating lamps (LED type). Square flush mounting voltmeter 0-500 volt with 3 way and OFF selector switch.BUSBAR1 Set of 250A, TPN Aluminum bus bars with colour coded sleeves. Outgoing Feeder 16 Nos. 16Amp TP MCB 10KA with D.O.L Suitable For 4Kw. 16 On Off Indication. 16 Push Button. 2 Nos. 63Amp 4P MCB10KA. 3 Nos. 32Amp DP MCB10KA. |
| 59 | Suppy & Fixing Of Fixtures 30W LEDLight Fixture Surface Mounted 2’x 2 ‘ |
| 60 | Supply of the following light fixtures complete with housing, reflectors, complete with all accessories i.e. driver, lamp, holders etc. complete as required. 15W LED Wall Light Fixture. |