Bids Are Invited For Fm 200, Major Fire Fighting System (M/S Tyco. Pac: Tyco, Mumbai) - Overhaul Complete Fm- 200 Control Panel Fitted At Dchq. Overhauling Includes Functional Checks Of Activation Limit Switches Of Pre Release Warning Of Fm 200 (Ist) On O, goa-Goa

Department of Defence Production has published Bids Are Invited For Fm 200, Major Fire Fighting System (M/S Tyco. Pac: Tyco, Mumbai) - Overhaul Complete Fm- 200 Control Panel Fitted At Dchq. Overhauling Includes Functional Checks Of Activation Limit Switches Of Pre Release Warning Of Fm 200 (Ist) On O. Submission Date for this Tender is 20-12-2021. Flame Detectors Tenders in goa Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30235634
Bids Are Invited For Fm 200, Major Fire Fighting System (M/S Tyco. Pac: Tyco, Mumbai) - Overhaul Complete Fm- 200 Control Panel Fitted At Dchq. Overhauling Includes Functional Checks Of Activation Limit Switches Of Pre Release Warning Of Fm 200 (Ist) On O
Open Tender
Indian
Goa
goa
20-12-2021

Tender Details

Bids Are Invited For Fm 200, Major Fire Fighting System (M/S Tyco. Pac: Tyco, Mumbai) - Overhaul Complete Fm- 200 Control Panel Fitted At Dchq. Overhauling Includes Functional Checks Of Activation Limit Switches Of Pre Release Warning Of Fm 200 (Ist) On Opening Of Door Of Control Panel At Mer & Gear Room, Aux.Er, Avcat, Msb & Mcr And Inclinator Room In. Main Indication Panel Followed By Gas Release And Low Pressure To Be Carried Out. Carry Out Functional Checks Of Crash Stop Ventilation On Opening Of Respective Compartment Door And Audio And Visual Alarm /Release Hooter Sound In All Compartment Of Machinery Space. Carry Out Operational Checks Of All Pressure Switches For Safety With No/Nc Contact Of All Relays Fitted Inside Fds Panel For Ipms System Information. Carry Out Functional Check Of 17 In No Pre Release Alarm / Release Alarm Hooters. Renew Defective Component. , 1 (Fire Detection System (M/S Tyco, Pac Fim)) - Carry Out Functionality Check Of Following Smoke, Heat, Flame And Ir Detector Sensor By Using Smoke, Heatuv/Ir And Flame Generating Electronic Appliances And Bell /Hooter Of Fire Detection System Component For Satisfactory Operation From Various Location.Renew/Repair Defective Sensors After Programming Their Type And Location In System For Auto Altert.(Maintenance Schedule No. Lp-41). , 2 (Fire Detection System (M/S Tyco, Pac Fim)) - Smoke Detector Opt Accommodation, 811Ph , 3 (Fire Detection System (M/S Tyco, Pac Fim)) - Smoke Detector Opt Water Proof , 811Ph , 4 (Fire Detection System (M/S Tyco, Pac Fim)) - Heat Detector Accommodation, 811 H , 5 (Fire Detection System (M/S Tyco, Pac Fim)) - Heat Detector Water Proof ,811 H , 6 (Fire Detection System (M/S Tyco, Pac Fim)) - Heat Detector For Higher Temperature-, T4e90x , 7 (Fire Detection System (M/S Tyco, Pac Fim)) - Uv/Ir Flame Detector, Eex-1-801Phex , 8 (Fire Detection System (M/S Tyco, Pac Fim)) - Smoke Detector, Eex-1-801Phex , 9 (Fire Detection System (M/S Tyco, Pac Fim)) - Flashing Light (Red For Ex Area, 24 V Dc) {Xenon Beacon(Ex)} , 10 (Fire Detection System (M/S Tyco, Pac Fim)) - Hydrocarbon Gas Ir Detector- Gp-Ir-Wd , 11 (Fire Detection System (M/S Tyco, Pac Fim)) - General Emergency Alarm Push Button , 12 (Fire Detection System (M/S Tyco, Pac Fim)) - Manual Call Point Accommodation , 13 (Fire Detection System (M/S Tyco, Pac Fim)) - Manual Call Point Water Proof , 14 (Fire Detection System (M/S Tyco, Pac Fim)) - Manual Call Point Water Proofexi , 15 (Fire Detection System (M/S Tyco, Pac Fim)) - Intric Safe Interface Barrier , 16 (Fire Detection System (M/S Tyco, Pac Fim)) - Flash Light Red 24 V (Xenon Beacon) , 17 (Fire Detection System (M/S Tyco, Pac Fim)) - Alarm Bell Accommodation , 18 (Fire Detection System (M/S Tyco, Pac Fim)) - Alarm Bell Water Proof , 19 (Fire Detection System (M/S Tyco, Pac Fim)) - Overhaul 02 No. Fire Detection Monitoring Controller (Main At Dchq & Slave At Bridge).Overhaulingincludes Following:-(A) Carry Out Visual Inspection And Cleaning Of Controller Inside And Outside. Check Intactness Of Ancillary Devices For Proper Function.(B) Carry Out Visual Check Of Heat Detector For Damage Due To Paint Dirt, Grease, And Lenses Of The Flame Detector Are Clear For Detection.(C) Clean / Renew Defective Units For Optimum Performance Of System.(D) Overhaul 24V Dc Back Up Power Supply Unit. Check Output Supply Of Battery Charger. Renew Defective Component Of Charger For Satisfactory Performance Trails With Controller With Back Up Supply For 4 Hours.(E)Carry Out Functional Check Of 04 In No. Loops Of Fds System Including Intric Safe Interface Barrier {(Exi 800+ P & F), Qty- 06 No., Line Isolating Module {(Lim 800), Qty- 06 No, Contact Input Module {(Cim 800), Qty- 06 No.( Each Cim 800 Consists Of 03 Nosinternal Module Pcbs}.(Maintenance Schedule No. Lp-41). , 20 (Fire Detection System (M/S Tyco, Pac Fim)) - Determine The Amount Of Agent In All Containers. The Optional Liquid Level Indicator May Be Used To Measure Agent Supply And Compare It To The Original Net Weight Which Is Marked On The Container Level. If The Measured Net Weight Is Less Than 95 % Of The Original Charged Weight, The Container Should Be Recharged Or Replaced Under Awrf. Carry Out Hydrostatic Pressure Test Offm-200 Cylinders (08 Nos), Nitrogen Cylinders (03 Nos) And Flexible Hoses.(03 Nos). Details Of Fm 200 Bottles As Follows: , 21 (Fire Detection System (M/S Tyco, Pac Fim)) - (A) Dgr/Mer/Gear Room - 407 Lbs , 22 (Fire Detection System (M/S Tyco, Pac Fim)) - (B) Incinerator Compartment - 68 Lbs , 23 (Fire Detection System (M/S Tyco, Pac Fim)) - (C) Mcr/Msb - 170 Lbs , 24 (Fire Detection System (M/S Tyco, Pac Fim)) - (D) Avcat Compartment - 339 Lbs , 25 (Fire Detection System (M/S Tyco, Pac Fim)) - (E) Avcat Service Tank Compt - 27 Lbs , 26 (Fire Detection System (M/S Tyco, Pac Fim)) - Test Pressure Switches For Operation And Electric Control Heads. , 27 (Fire Detection System (M/S Tyco, Pac Fim)) - Inspect All Piping For Looseness, Dirt Or Other Damage In All Piping, Fitting And Nozzles To Be Carried Out Due To Aging. All Outlet Piping Must Be Clean, Blow Through By Air, Free Of Dirt, Chips, Filling And Other Foreign Materials That May Cause The System To Become Inoperative Or Ineffective At The Time Of Discharge. Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1FM 200, MAJOR FIRE FIGHTING SYSTEM (M/S TYCO. PAC: TYCO, MUMBAI)Overhaul Complete FM- 200 Control panel fitted at DCHQ. Overhauling includes functional checks of activation limit switches of Pre release warning of FM 200 (Ist) on opening of door of control panel at MER & Gear room, AUX.ER, Avcat, MSB & MCR and Inclinator room in. Main indication panel followed by Gas release and Low pressure to be carried out. Carry out functional checks of Crash stop ventilation on opening of respective compartment Door and Audio and Visual Alarm /release Hooter sound in all compartment of machinery space. Carry out operational checks of all pressure Switches for safety with NO/NC contact of all relays fitted inside FDS panel for IPMS system Information. Carry out functional check of 17 in no Pre release Alarm / Release Alarm Hooters. Renew defective component.
21 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Carry out functionality check of following Smoke, Heat, Flame and IR detector sensor by using smoke, heatUV/IR and Flame generating Electronic appliances and bell /hooter of Fire Detection System component for satisfactory operation from various location.Renew/repair defective sensors after programming their type and location in system for auto altert. (Maintenance schedule no. LP-41).
32 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Smoke detector Opt Accommodation, 811PH
43 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Smoke detector Opt water proof , 811PH
54 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Heat Detector Accommodation, 811 H
65 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Heat Detector water proof ,811 H
76 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Heat Detector for Higher Temperature-, T4E90X
87 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))UV/IR flame detector, EEX-1-801PHEX
98 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Smoke detector, EEX-1-801PHEX
109 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Flashing light (red for Ex Area, 24 V DC) {Xenon Beacon(ex)}
1110 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Hydrocarbon gas IR Detector- GP-IR-WD
1211 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))General Emergency alarm push button
1312 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Manual call point Accommodation
1413 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Manual call point water proof
1514 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Manual call point water proofExi
1615 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Intric safe interface barrier
1716 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Flash light Red 24 V (Xenon Beacon)
1817 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Alarm bell Accommodation
1918 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Alarm bell water proof
2019 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Overhaul 02 no. Fire Detection Monitoring controller (Main at DCHQ & Slave at Bridge).Overhaulingincludes following:- (a) Carry out Visual inspection and cleaning of controller inside and outside. Check intactness of ancillary devices for proper function. (b) Carry out Visual check of heat detector for damage due to paint dirt, grease, and lenses of the flame detector are clear for detection. (c) Clean / renew defective units for optimum performance of system. (d) Overhaul 24V DC Back up power supply unit. Check output supply of battery charger. Renew defective component of charger for satisfactory performance trails with controller with back up supply for 4 Hours. (e)Carry out functional check of 04 in No. loops of FDS system including Intric safe interface barrier {(EXI 800+ P & F), Qty- 06 No., Line isolating Module {(LIM 800), Qty- 06 No, Contact Input Module {(CIM 800), Qty- 06 No.( Each CIM 800 consists of 03 Nosinternal module PCBs}. (Maintenance schedule no. LP-41).
2120 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Determine the amount of agent in all containers. The optional liquid level indicator may be used to measure agent supply and compare it to the original net weight which is marked on the container level. If the measured net weight is less than 95 % of the original charged weight, the container should be recharged or replaced under AWRF. Carry out hydrostatic pressure test ofFM-200 cylinders (08 nos), Nitrogen cylinders (03 nos) and flexible hoses.(03 nos). Details of FM 200 bottles as follows:
2221 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))(a) DGR/MER/Gear room - 407 lbs
2322 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))(b) Incinerator compartment - 68 lbs
2423 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))(c) MCR/MSB - 170 Lbs
2524 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))(d) AVCAT Compartment - 339 lbs
2625 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))(e) AVCAT Service tank Compt - 27 lbs
2726 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Test pressure switches for operation and electric control heads.
2827 (FIRE DETECTION SYSTEM (M/S TYCO, PAC FIM))Inspect all piping for looseness, dirt or other damage in all piping, fitting and nozzles to be carried out due to aging. All outlet piping must be clean, blow through by air, free of dirt, chips, filling and other foreign materials that may cause the system to become inoperative or ineffective at the time of discharge.