| 1 | Dismantling tiledroofing (mangalore or pot or country tiles) with battens etc. complete including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 2 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 3 | b) Providing and fixing Colouron Plus galvulium roofing Sheets of 0.5mm thick double ribbed trapezoidal profile coated 1080mmwith cover width of 1020mmincluding all the accessories(JSW or equivalent make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 4 | c) providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 5 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. |
| 6 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 7 | Providing and laying in position cement concrete 1:2:4(1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost ofcentering,shuttering and finishing : |
| 8 | a) All works upto plinth level |
| 9 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement :4 coarse sand)in foundation and basement. |
| 10 | Repairs to plaster in patches of 2.5 sq.m. and under including cuttingthe patch in proper shape and preparingand plastering the surface of the walls complete including disposal of rubbish to the dumpingground within 50m lead. |
| 11 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | PVC false ceiling grid type: Providing and fixing PVC False Ceiling of make Rajshri Plastiwood or equivalentconsisting of 600mm x 600mm, 5mm(±0.25) thick Plain PVC sheet of 600 kg/Cbm DensityManufactured by an ISO-9000 certified Company, used as panel insert in a frame work made using anodized aluminum T- section of sizes 1” x1” (25x25mm, 19gauge or 1mm thick) in square pattern of grid sizes of 2’x2’(600x600mm). The aluminum framework is supported from the ceiling with the help of \"J\" hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level etc. The aluminum framework is supported on side wall with the use of aluminum L-section of size 1”x1” (25x25mm) angles etc. Complete as per direction of Engineer-In-charge, manufacturer’s specification & drawing. |
| 14 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) |
| 15 | c) In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level |
| 16 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) )(Confirming to IS 1786 of 1986)forsdcfRCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floorsalongwith the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 17 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 18 | xiii) Suspended floors, roofs landings, shelves & their supports |
| 19 | Proving and fixing white vitreous china water closet squating (European type w.c. pan) with seat and lid,C.P. brass hingesand rubber buffers 10 lts. Highlevel P.V.C..flushing cistern (of approved make ) with fittings, rack bolts 32 mmdiameter P.V.C.telescopic flush pipe with fit tings and clamps 25mm P.V.C.. over flow pipe withspecials & mosquito proof coupling of approved municipal design and nylon. chain and pull complete, cutting and making good the walls ad floors where required. |
| 20 | a) W.C. pan with white plastic seat and lid. |
| 21 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. |
| 22 | b) Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps. |
| 23 | Providing and fixing rigid PVC S.W.W. (soil, waste & rain water) drainage pipes ofapproved including lubricant etc. complete (single/double) socketed: |
| 24 | 110 mm dia |
| 25 | 75 mm dia |
| 26 | Providing and fixing rigid PVCbend of required degree (of approved make) for S.W.R. drainage pipes ofapproved including lubricating. |
| 27 | 110 mm dia |
| 28 | 75 mm dia |
| 29 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming toI S 12701; 1996. |
| 30 | b) 500 lit. capacity |
| 31 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). |
| 32 | b) 20 mm outer dia CPVC pipe |
| 33 | Providing and fixing brass stop cock (heavy) of approved quality : |
| 34 | b) 20 mm nominal bore |
| 35 | Providing and fixing non-return valve of approved quality : |
| 36 | a) 25 mm nominal bore |
| 37 | Providing and fixing brass bib cock (heavy) of approved quality : |
| 38 | b) 20 mm nominal bore |
| 39 | Providing and fixing brass full way valve(heavy) duty with wheelof approved quality : |
| 40 | b) 20 mm nominal bore |
| 41 | Providing and fixing ballvalve(brass)ofapproved quality : |
| 42 | a) High pressure with P.V.C. floats: |
| 43 | 2) 20 mm nominal bore |
| 44 | Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design. |
| 45 | FRP (Fiber Reinforced Polymer) Frames |
| 46 | Manufacture, Supply and Installation (with anchor fastener) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) Frame of cross section as per options below with right angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door.. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2008 certified company. |
| 47 | b) 4” x 2” |
| 48 | Single Colour Foam Core FRP (Fiber Reinforced Polymer) Door Shutter |
| 49 | Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by usingtray system with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) . The core of shutter will be filled as specified (Expanded Polystyrene Foam / Polyurethane Foam (EPS/PU) Foam). The shutter to be of single colour & water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2008 certified factory. |
| 50 | Accessories: |
| 51 | i) S. S. Hinges 4” - 3 Nos |
| 52 | ii) S. S. Latch - 1 No |
| 53 | iii) Tower Bolt 5” - 2 Nos |
| 54 | iv) Handle 5”- 2 Nos |
| 55 | Shutter Thickness: a) 30mm |
| 56 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section. |
| 57 | b) Plan glass |
| 58 | Extra For powder coating with pure polyester powder of shade of required colour on the aluminium section |
| 59 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Fixed windows/ ventilators matching with 18 mm series shutters. |
| 60 | c) Figured glass |
| 61 | Extra For powder coating with pure polyester powder of shade of required colour on the aluminium section |
| 62 | Providing and and laying vitrified floor tiles in different sizes of Johnson, Somany, Kajaria(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approvedmake in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete |
| 63 | b) 600x 600 mm loght Shades |
| 64 | Providing and fixing vitrified antiskid tiles(320x320) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed ofcement mortar 1:3 and jointed with cement slurry complete. |
| 65 | Providing and fixing coloured ceramic tiles spartek or equivalent of 8\" x 8\" size and 6 mm thick in skirtingand dados on 12 thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry complete. |
| 66 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws. |
| 67 | a) Plain grill |
| 68 | Providing and fixing 35mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including black enameled iron butt hinges with necessary screws: |
| 69 | b) Nano or equivalent |
| 70 | Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon. |
| 71 | d) Second class Indian teak wood |
| 72 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 73 | Wall painting(two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 74 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as Dulex/Asian Paints/Sherwin Willans) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 75 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 76 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. |
| 77 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 78 | d) Inside size 60 x 60cmand 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 79 | Salvage value of the dismantled Mangalore tile roofing of proposed site.. Etc complete. |
| 80 | Salvage value of the dismantled wood of roofing proposed site.. Etc complete. |