}

Bids Are invited for RELAY,MOTOR PROTECTION,RANGE:2-16A - MICROCONTROLLER BASED MOTOR PROTECTION RELAY 2 A-16A RELAY SHALL HAVETHERMAL OVER LOAD PROTECTION IN THE RANGE OF 2-16A,EARTH FAULTPROTECTION, PHASE UNBALANCE, LOCKED ROTOR PROTECTION, UNDERCURRENT-Odisha

Steel Authority Of India Limited has published Bids Are invited for RELAY,MOTOR PROTECTION,RANGE:2-16A - MICROCONTROLLER BASED MOTOR PROTECTION RELAY 2 A-16A RELAY SHALL HAVETHERMAL OVER LOAD PROTECTION IN THE RANGE OF 2-16A,EARTH FAULTPROTECTION, PHASE UNBALANCE, LOCKED ROTOR PROTECTION, UNDERCURRENT. Submission Date for this Tender is 28-12-2021. Din Rail Tenders in Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

30178941
Bids Are invited for RELAY,MOTOR PROTECTION,RANGE:2-16A - MICROCONTROLLER BASED MOTOR PROTECTION RELAY 2 A-16A RELAY SHALL HAVETHERMAL OVER LOAD PROTECTION IN THE RANGE OF 2-16A,EARTH FAULTPROTECTION, PHASE UNBALANCE, LOCKED ROTOR PROTECTION, UNDERCURRENT
Open Tender
NCB
Odisha
28-12-2021

Tender Details

Bids Are invited for RELAY,MOTOR PROTECTION,RANGE:2-16A - MICROCONTROLLER BASED MOTOR PROTECTION RELAY 2 A-16A RELAY SHALL HAVETHERMAL OVER LOAD PROTECTION IN THE RANGE OF 2-16A,EARTH FAULTPROTECTION, PHASE UNBALANCE, LOCKED ROTOR PROTECTION, UNDERCURRENT PROTECTION, LOSS OF PHASE/SINGLE PHASING, PHASE REVERSALMONITORING WITH ADJUSTABLE SETTING IN ALL TYPES OF PROTECTION.RELAY SHALL HAVE INTEGRAL CURRENT TRANSFORMER (CT) FOR ITS OPERATION.RELAY SHALL HAVE CONTINUOUS DISPLAY OF MEASURED HEALTHY/FAULT CURRENTS.RELAY SHALL ALSO HAVE MANUAL TEST/RESET FACILITY.AUXILIARY POWER SUPPLY :110-275V AC/DC,MOUNTING: DIN RAILLIMITING DIMENSIONS IN MM: 70 X 75 X 109 (WXHXL),OPERATING TEMP : UPTO 60 DEG CENT.TRIP ACCURACY SHOULD BE AS PER IEC 947-4-1TRIP CLASS 10A, 10, 20, & 30PICK-UP ACCURACY SHOULD BE GREATER THAN 10%PRE-ALARM FACILITY SHOULD BE THERE.ENABLE/DISABLE OPTION FOR EARTH FAULT, UNDER CURRENT, LOCKEDROTOR ANDPHASE UNBALANCE PROTECTION.FAULT RECORDS UP TO 20 WITH DATE AND TIME STAMPINGS.OUTPUT CONTACTS(POTENTIAL FREE): 1NO/NC250VAC(5A) AND 2NO/NC 250VAC(8A) , RELAY,MOTOR PROTECTION,RANGE:16-32A - MICROCONTROLLER BASED MOTOR PROTECTION RELAY 16 A-32A RELAY SHALL HAVETHERMAL OVER LOAD PROTECTION IN THE RANGE OF 16-32A,EARTH FAULT PROTECTION, PHASE UNBALANCE, LOCKED ROTOR PROTECTION, UNDERCURRENT PROTECTION, LOSS OF PHASE/SINGLE PHASING, PHASE REVERSALMONITORING WITH ADJUSTABLE SETTING IN ALL TYPES OF PROTECTION.RELAYSHALL HAVE INTEGRAL CURRENT TRANSFORMER (CT) FOR ITS OPERATION.RELAY SHALL HAVE CONTINUOUS DISPLAY OF MEASURED HEALTHY/FAULT CURRENTS.RELAY SHALL ALSO HAVE MANUAL TEST/RESET FACILITY.AUXILIARY POWER SUPPLY :110-275V AC/DC, MOUNTING: DIN RAIL LIMITINGDIMENSIONS IN MM: 70 X 75 X 109 (WXHXL),OPERATING TEMP : UPTO 60 DEGCENT. TRIP ACCURACY SHOULD BE AS PER IEC 947-4-1TRIP CLASS 10A, 10, 20 AND 30PICK-UP ACCURACYSHOULD BE GREATER THAN 10% PRE-ALARM FACILITY SHOULD BE THERE.ENABLE/DISABLE OPTION FOR EARTH FAULT, UNDER CURRENT, LOCKED ROTOR ANDPHASE UNBALANCE PROTEC

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail