Bids Are Invited For Providing, Fixing, Testing And Commissioning Of Gi Class C ( A ) 100 Mm Dia - Providing, Fixing, Testing And Commissioning Of Gi Class C Isi Marked Pipe Line With Jointing And Fitting Mate, Navsari-Gujarat

Directorate Of Employment And Training-DGET has published Bids Are Invited For Providing, Fixing, Testing And Commissioning Of Gi Class C ( A ) 100 Mm Dia - Providing, Fixing, Testing And Commissioning Of Gi Class C Isi Marked Pipe Line With Jointing And Fitting Mate. Submission Date for this Tender is 15-12-2021. Nuts Supply Tenders in Navsari Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

30177776
Bids Are Invited For Providing, Fixing, Testing And Commissioning Of Gi Class C ( A ) 100 Mm Dia - Providing, Fixing, Testing And Commissioning Of Gi Class C Isi Marked Pipe Line With Jointing And Fitting Mate
Open Tender
Indian
Gujarat
Navsari
15-12-2021

Tender Details

Bids Are Invited For Providing, Fixing, Testing And Commissioning Of Gi Class C ( A ) 100 Mm Dia - Providing, Fixing, Testing And Commissioning Of Gi Class C Isi Marked Pipe Line With Jointing And Fitting Materials Clamps & Screws Eracting Masonary Supports Including Wraping Of Pipe With Bitumenous Cloth Complete ( A ) 100 Mm Dia [ Make:Asian / Jindal / Zenith ] , Providing, Fixing, Testing And Commissioning Of Gi Class C ( B ) 80 Mm Dia. - ( B ) 80 Mm Dia. [ Make:Asian / Jindal / Zenith ] , Providing And Fixing Of Ci Butterflay Valve Isi Marked ( A ) 100 Mm Dia - Providing And Fixing Of Ci Butterflay Valve Isi Marked Withsg Ion Working Parts With Stainless Steelspindel With Necessary Jointinh Materials Filing Etc. Complete As Directed. ( A ) 100 Mm Dia [ Make:Zoloto / Kranti / Sant ] , Providing And Fixing Of Ci Butterflay Valve Isi Marked ( B ) 80 Mm Dia. - ( B ) 80 Mm Dia. [ Make:Zoloto / Kranti / Sant ] , Providing, Fixing, Testing And Commissioning Of Non-Return Valve Dual Plate Of Following Sizes Conforming To Is: 5312 ( A ) 100 Mm Dia - Providing, Fixing, Testing And Commissioning Of Non-Return Valve Dual Plate Of Following Sizes Conforming To Is: 5312 Complete With Rubber Gasket, Gibolts, Nuts, Washers Etc. As Required, ( A ) 100 Mm Dia [ Make:Zoloto / Kranti / Sant ] , ( B ) 80 Mm Dia. - ( B ) 80 Mm Dia. [ Make:Zoloto / Kranti / Sant ] , Providing, Fixing, Testingandcommissioningofss Single Headed - Providing, Fixing, Testingandcommissioningofss Single Headed Isimarked Oblique Pattern Hydrant Landing Valves Asper Is:5290 With 80Mm Dia Flanged Inlet And 63Mm Dia Female Outlet Complete With Ss Cap. [ Make:Safetap / Shah Bhogilal / Swati ] , Providing, Fixing, Testing And Commissioning Of Standard Ss Branch Pipe With Nozzle Of 20 Mm Nominal Bore Outlet - Providing, Fixing, Testing And Commissioning Of Standard Ss Branch Pipe With Nozzle Of 20 Mm Nominal Bore Outlet As Per Is:903 Suitable To Fit With Standard Instanteneous Type 63 Mm Dia Coupling. [ Make:Safetap / Shah Bhogilal / Swati ] , Providing And Fixing 63 Mm Dia Reinforced Rubber Lined Rrl Rrl Firehose Ofapproved Grand Conforming To Is 636 Type A - Providing And Fixing 63 Mm Dia Reinforced Rubber Lined Rrl Rrl Firehose Ofapproved Grand Conforming To Is 636 Type A Having Brushing Pressure Of 37.20 Kg / Cm2 And 1 Nos Of Isi Marked Of 15 Mtr Length Fitting With Necessary Ss 63 Mm Delivered Hose Pipe With 63 Mm Dia. Male And Female Ss Couplings Duly Binded With Gi Wire, Rivets Etc. Conforming To Is 636 ( Type-A ) As Required. [ Make:Safetap ] , Providing, Fixing, Testing And Commissioningof Weatherproofstandard Fire Hose Cabinet - Providing, Fixing, Testing And Commissioningof Weatherproofstandard Fire Hose Cabinet Having Single Opening With M.S. Fabricated Stand, Necessarylockingarrangementbyallankeysuitablefor Housing 1 No. Hose Pipe, 1No. Branch Pipe & Nozzle Spaner. , Supplying And Fixing First Aid Hose Reel With Ms Construction Spraypainted In Post Office Red. - Supplying And Fixing First Aid Hose Reel With Ms Construction Spraypainted In Post Office Red, Conforming To Is 884 With Upto Date Amendments, Completewiththefollowingasrequired.30Mlong20 Mm ( Nominal Internal ) Dia Water Hose Thermoplastic ( Textile Rainforced ) Type-2 As Per Is: 12585 25Mm ( Nominal Internal ) Dia S.S.Shut Up Valve & Nozzle. Drum And Brackets For Fixing The Equipments On Wall. [ Make:Safetap, Safepro / Kiaan ] , Supply, Installation, Testing & Commissioning Of 20Mm Dia Ss Isi Mark Gate Valve With 20 Mm Diaas Complete As Directed. - Supply, Installation, Testing & Commissioning Of 20Mm Dia Ss Isi Mark Gate Valve With 20 Mm Diaas Complete As Directed. [ Make:Kranti / Sant ] , Providing & Fixing Emergency Escape Signes / Printed Onacrylic Sheet 2 Mm Thick Photoluminescent Auto Glow Type Of Approved Quality - Providing & Fixing Emergency Escape Signes / Printed Onacrylic Sheet 2 Mm Thick Photoluminescent Auto Glow Type Of Approved Quality Including Fixing On Door, Wall, Celling Complete With Installation As Directed.Signes , Supply, Installation, Testing And Commissioning Of Main Fire Pump Horizontal Centrifugal -Ve End Suction Monoblock Type / Submercible Pump Set As Per Requirement - Supply, Installation, Testing And Commissioning Of Main Fire Pump Horizontal Centrifugal -Ve End Suction Monoblock Type / Submercible Pump Set As Per Requirement Fire Ofchief Officer Of Following Features Andcapacity. 1.Head-70Mtr, Discharge-98 M3 / Hr.As Capacity Of Pump Set. Rate Includes Base Frame , Coupling, Cover ( Ms ) , Coupling Guard, Foundation And Foundation Bolts In Case Of Mono Block Type Pump Setfor Monoblock - Lubi / Kirloskar / Mather&Platta ) , Supply, Installation, Testing And Commissioning Of Jockey Pumpset Horizontalcentrifugal-Vesuctionmonoblocktype / Submercible - Supply, Installation, Testing And Commissioning Of Jockey Pumpset Horizontalcentrifugal-Vesuctionmonoblocktype / Submercible, Having Capacity 10.8 M3 / Hr & 70 Mtr Headcomplete With Base Frame , Coupling, Cover ( Ms ) , Coupling Guard, Foundation And Foundation Bolts In Case Of Mono Block Type Pump Set & With 15 Mtr Cable For Rated Capacity Of Pump Set. [ Make:Lubi / Kirloskar / Mather&Platta / Klug ] , Supply, Installation, Testing And Commissioning Ofcommoncontrol Panel Starter For Pump ( Main Pump &Jockey Pump ) - Supply, Installation, Testing And Commissioning Ofcommoncontrol Panel Starter For Pump ( Main Pump &Jockey Pump ) [ Make:L&T ] , Supply And Laying Of 3C X 16 Sq.Mm Pvc Copper Flat Cable With Allrequire Accessories For Main Pump. - Supply And Laying Of 3C X 16 Sq.Mm Pvc Copper Flat Cable With All Require Accessories For Main Pump. [ Make:Rr Cable, Polycab, Anchor ] , Supply And Laying Of 3C X 6 Sq.Mm Pvc Copper Flat Cable With Allrequireaccessoriesforjockeypump. - Supply And Laying Of 3C X 6 Sq.Mm Pvc Copper Flat Cable With Allrequireaccessoriesforjockeypump. [ Make:Rr Cable, Polycab, Anchor ] , Providing And Fixing Of Dial Type Pressure Guage Having 100 Mm Dial& Range Of0-14 Kg / Cm2 With Isolation Ball Valve. - Providing And Fixing Of Dial Type Pressure Guage Having 100 Mm Dial& Range Of0-14 Kg / Cm2 With Isolation Ball Valve. , Pressureswitchwithneedlevalve ( Approvedmakeandmodelinstruct By Eic ( Only ) - Pressureswitchwithneedlevalve ( Approvedmakeandmodelinstruct By Eic ( Only ) [ Make:Danfoss / Indfoss ] , Providing And Fixing Ofair Release Valve Including Ball Valve 25Mmdia. - Providing And Fixing Ofair Release Valve Including Ball Valve 25Mmdia. [ Make:Zoloto / Sant ] , Getting Provisional Noc And Final Nocfor Firehydrantsystem, Fire Extinguisher From Local Fire Authority - Getting Provisional Noc And Final Nocfor Firehydrantsystem, Fire Extinguisher From Local Fire Authority Or Any Other Relevant Statutory Authority At Initial And Required Various Other Stages Of Construction Work, Including Preparation Of Report / Drawings As Per Fire Authority Requirement.Agency Has To Borne Charges Like Preparingand Submissionof All The Documents, Photographs, Cd / Dvd Required To Get The Noc From Concern Fire Department And Also Liaisoning Work With Concern Departments. The Legal And Other Charges To Get Noc Also Will Be Borne By Contractor , Providing , Fixing , Testing And Commissionning Of Suitablezone Convetionalpanel For Fire Alarm System. - Providing , Fixing , Testing And Commissionning Of Suitablezone Convetionalpanel For Fire Alarm System. , Providing , Fixing , Testing And Commissionning Of Manual Call Point. ( Switch With All Required ) - Providing , Fixing , Testing And Commissionning Of Manual Call Point. ( Switch With All Required ) , Providing , Fixing , Testing And Commissionning Of Hooter. ( Make :Agni / System Sensor ) - Providing , Fixing , Testing And Commissionning Of Hooter. ( Make :Agni / System Sensor ) , Executing Non Comprehensive ( All -In-All ) Service & Maintenance With Spare Parts As Per Terms & Conditionof Tender For Fire Hydrant System, Fire Extinguisher With Fire Hydrant Agency . - Executing Non Comprehensive ( All -In-All ) Service & Maintenance With Spare Parts As Per Terms & Conditionof Tender For Fire Hydrant System, Fire Extinguisher With Fire Hydrant Agency . Agency Has To Also Provide The Fitness Certificate On Quaterly Basis For One Year And 2 Year Renewal . Refillingfor Co2 And Abc Type Fire Extinguisher If Required To Get The Nocfrom Fire Department.The Necessary Certificate / Photographsfor That Must Be Submitted.Agency Has To Do Maintenance As Per Terms & Condition Alternate Intender.Refillinghydraulicallypressureforco2andabctypefire Extinguisher If Required To Get The Nocfrom Fire Department. , Providing And Fixing Of Abc Cartridge Type Fire Extinguisher Suitable Forextinguising A, Bandcfireshaving Capacity 6Kgconfirms To Is:15683:2006 - Providing And Fixing Of Abc Cartridge Type Fire Extinguisher Suitable Forextinguising A, Bandcfireshaving Capacity 6Kgconfirms To Is:15683:2006 With Mono Amonium Phosphate ( Map 50 % Powder ) Dry Chemical Powder. Refilling Of All Abc Cartridge Type Fire Extinguisherup To 2Year As Per Fire N.B.C Norms. , Providing And Fixing Of Co2 Type Fire Extinguisher Of Capacity 4.5 Kg Filled With Co2 Gas - Providing And Fixing Of Co2 Type Fire Extinguisher Of Capacity 4.5 Kg Filled With Co2 Gas As Per Is 15222 With Controll Discharge Mechanis, Fitted With Hose & Horn Applicable On Class B Fire Rating 21B Confirms To Is 15683 Bearing Isi Mark. Co2 Cylinder As Per Is 7285.Refilling Of All Co2 Type Fire Extinguisher Up To 2Year As Per Fire N.B.C Norms. , Providing And Fixing Of Fire Bucket With Stand - Providing And Fixing Of Fire Bucket With Stand Capacity Of 10 Ltr Bucket 03 No With Stand [ Make:Asian / Jindal / Zenith ] , Providingunder Ground Water Tank Of 30000 Ltr Capacity - Providingunder Ground Water Tank Of 15000 Ltr Capacity , Tank Construction Of Concrete With Cover As Per Civil Construction Rules. , Emergency Exit Provisional - Emergency Exit Provisionalfor 2 ( Two ) Floor Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1Providing, fixing, testing and commissioning of GI class C (A) 100 mm diaProviding, fixing, testing and commissioning of GI class C ISI Marked pipe line with jointing and fitting materials clamps & screws eracting masonary supports including wraping of pipe with bitumenous cloth complete (A) 100 mm dia[Make:ASIAN/JINDAL/Zenith]
2Providing, fixing, testing and commissioning of GI class C(B)80 mm dia.(B)80 mm dia.[Make:ASIAN/JINDAL/Zenith]
3Providing and fixing of CI Butterflay valve ISI marked(A) 100 mm diaProviding and fixing of CI Butterflay valve ISI marked with Sg Ion working parts with stainless steelspindel with necessary jointinh materials filing etc. complete as directed. (A) 100 mm dia[Make:Zoloto/Kranti/SANT]
4Providing and fixing of CI Butterflay valve ISI marked (B)80 mm dia.(B)80 mm dia.[Make:Zoloto/Kranti/SANT]
5Providing, fixing, testing and commissioning of non-return valve Dual Plate of following sizes conforming to IS: 5312 (A) 100 mm diaProviding, fixing, testing and commissioning of non-return valve Dual Plate of following sizes conforming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required, (A) 100 mm dia[Make:Zoloto/Kranti/SANT]
6(B)80 mm dia.(B)80 mm dia.[Make:Zoloto/Kranti/SANT]
7Providing,fixing,testingandcommissioningofSS single headedProviding,fixing,testingandcommissioningofSS single headed ISImarked oblique pattern hydrant landing valves asper IS:5290 with 80mm dia flanged inlet and 63mm dia female outlet complete with SS cap.[Make:Safetap/Shah Bhogilal/Swati]
8Providing, fixing, testing and commissioning of Standard SS branch pipe with nozzle of 20 mm nominal bore outletProviding, fixing, testing and commissioning of Standard SS branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instanteneous type 63 mm dia coupling.[Make:Safetap/Shah Bhogilal/Swati]
9Providing and fixing 63 mm dia reinforced rubber lined RRL RRL fire hose ofapproved grand conforming to IS 636 type AProviding and fixing 63 mm dia reinforced rubber lined RRL RRL fire hose ofapproved grand conforming to IS 636 type A having brushing pressure of 37.20 Kg/cm2 and 1 Nos of ISI marked of 15 mtr length fitting with necessary SS 63 mm delivered hose pipe with 63 mm dia. Male and female SS couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required.[Make:Safetap]
10Providing,fixing, testing and commissioningof Weatherproof standard fire hose cabinetProviding,fixing, testing and commissioningof Weatherproof standard fire hose cabinet having single opening with M.S. Fabricated Stand,necessarylockingarrangementbyallankeysuitablefor housing 1 no. hose pipe, 1no. Branch pipe & nozzle spaner.
11Supplying and fixing First Aid hose reel with MS construction spray painted in post office red.Supplying and fixing First Aid hose reel with MS construction spray painted in post office red, conforming to IS 884 with upto date amendments,completewiththefollowingasrequired.30mlong 20 mm (nominal internal) dia water hose thermoplastic (textile rainforced) type-2 as per IS: 12585 25mm (nominal internal) dia S.S.Shut up valve & nozzle. Drum and brackets for fixing the equipments on wall. [Make:Safetap,Safepro/KIAAN]
12Supply, Installation, Testing & commissioning of 20mm dia SS ISI mark Gate Valve with 20 mm diaas complete as directed.Supply, Installation, Testing & commissioning of 20mm dia SS ISI mark Gate Valve with 20 mm diaas complete as directed.[Make:Kranti/Sant]
13providing & fixing emergency escape signes/ printed onacrylic sheet 2 mm thick photoluminescent auto glow type of approved qualityproviding & fixing emergency escape signes/ printed onacrylic sheet 2 mm thick photoluminescent auto glow type of approved quality including fixing on door, wall, celling complete with installation as directed.Signes
14Supply, Installation, Testing and Commissioning of Main fire pump horizontal centrifugal -ve end suction monoblock type/ submercible pump set as per requirementSupply, Installation, Testing and Commissioning of Main fire pump horizontal centrifugal -ve end suction monoblock type/ submercible pump set as per requirement fire ofchief officer of following features andcapacity. 1.head-70mtr, Discharge-98 m3/hr.as capacity of pump set. Rate includes base frame , coupling, cover(MS), coupling guard, Foundation and foundation bolts in case of mono block type pump setFor Monoblock - Lubi / Kirloskar /Mather&Platta)
15Supply, Installation, Testing and Commissioning of Jockey Pumpset horizontalcentrifugal-vesuctionmonoblocktype/submercibleSupply, Installation, Testing and Commissioning of Jockey Pumpset horizontalcentrifugal-vesuctionmonoblocktype/submercible, having capacity 10.8 M3/Hr & 70 Mtr Headcomplete with base frame , coupling, cover(MS), coupling guard, Foundation and foundation bolts in case of mono block type pump set & with 15 mtr cable for rated capacity of pump set.[Make:Lubi / Kirloskar /Mather&Platta/Klug]
16Supply, Installation, testing and commissioning ofcommon Control Panel Starter for Pump (Main Pump &Jockey Pump)Supply, Installation, testing and commissioning ofcommon Control Panel Starter for Pump (Main Pump &Jockey Pump) [Make:L&T]
17Supply and laying of 3C x 16 sq.mm PVC Copper Flat cable with all require accessories for Main Pump.Supply and laying of 3C x 16 sq.mm PVC Copper Flat cable with all require accessories for Main Pump.[Make:RR Cable,PolyCab,Anchor]
18Supply and laying of 3C x 6 sq.mm PVC Copper Flat cable with all requireaccessoriesforJockeyPump.Supply and laying of 3C x 6 sq.mm PVC Copper Flat cable with all requireaccessoriesforJockeyPump. [Make:RR Cable,PolyCab,Anchor]
19Providing and fixing of dial type Pressure Guage having 100 mm dial & range of0-14 Kg/cm2 with isolation ball valve.Providing and fixing of dial type Pressure Guage having 100 mm dial & range of0-14 Kg/cm2 with isolation ball valve.
20PressureswitchwithNeedlevalve(ApprovedMakeandModel Instruct by EIC (Only)PressureswitchwithNeedlevalve(ApprovedMakeandModel Instruct by EIC (Only)[Make:Danfoss/Indfoss]
21Providing and fixing ofAir Release Valve including Ball Valve 25mm dia.Providing and fixing ofAir Release Valve including Ball Valve 25mm dia.[Make:Zoloto/Sant]
22Getting provisional NOC and Final NOCfor Fire Hydrantsystem, Fire Extinguisher from local fire authorityGetting provisional NOC and Final NOCfor Fire Hydrantsystem, Fire Extinguisher from local fire authority or any other relevant statutory authority at initial and required various other stages of construction work, including preparation of report/drawings as per fire authority requirement.Agency has to borne charges like preparingand submissionof all the documents,Photographs, CD/DVD required to get the NOC from concern fire department and also liaisoning Work with concern departments. The legal and other charges to get NOC also will be borne by contractor
23Providing , Fixing , testing and commissionning of suitablezone convetional Panel for Fire Alarm System.Providing , Fixing , testing and commissionning of suitablezone convetional Panel for Fire Alarm System.
24Providing , Fixing , testing and commissionning of manual Call point. ( Switch With all Required )Providing , Fixing , testing and commissionning of manual Call point. ( Switch With all Required )
25Providing , Fixing , testing and commissionning of Hooter. ( Make : Agni / System Sensor )Providing , Fixing , testing and commissionning of Hooter. ( Make : Agni / System Sensor )
26Executing non comprehensive (All -in-All) service & maintenance with spare parts as per terms & conditionof tender for Fire hydrant system, Fire Extinguisher with fire hydrant agency .Executing non comprehensive (All -in-All) service & maintenance with spare parts as per terms & conditionof tender for Fire hydrant system, Fire Extinguisher with fire hydrant agency . Agency has to also provide the fitness certificate on Quaterly basis for one year and 2 year renewal . Refillingfor CO2 and ABC type fire extinguisher if required to get the NOCfrom fire department.The necessary certificate / photographsfor that must be submitted.Agency has to do maintenance as per terms & condition alternate intender.RefillingHydraulicallypressureforCO2andABCtypefire extinguisher if required to get the NOCfrom fire department.
27Providing and fixing of ABC cartridge type fire extinguisher suitable for extinguising A,BandCFiresHaving capacity 6KgConfirms to IS:15683:2006Providing and fixing of ABC cartridge type fire extinguisher suitable for extinguising A,BandCFiresHaving capacity 6KgConfirms to IS:15683:2006 with Mono Amonium Phosphate (MAP 50 % powder)Dry Chemical Powder. Refilling of all ABC cartridge type fire extinguisherUp to 2Year as per Fire N.B.C Norms.
28Providing and fixing of CO2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 GasProviding and fixing of CO2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanis, fitted with Hose & Horn applicable on Class B fire rating 21B confirms to IS 15683 bearing ISI mark. Co2 cylinder as per IS 7285.Refilling of all CO2 type Fire Extinguisher Up to 2Year as per Fire N.B.C Norms.
29Providing and fixing of Fire Bucket With StandProviding and fixing of Fire Bucket With Stand Capacity of 10 Ltr Bucket 03 No With Stand[Make:ASIAN/JINDAL/Zenith]
30ProvidingUnder Ground Water Tank of 30000 ltr CapacityProvidingUnder Ground Water Tank of 15000 ltr Capacity , Tank Construction of Concrete With Cover As Per Civil Construction Rules.
31Emergency Exit ProvisionalEmergency Exit ProvisionalFor 2(Two) Floor
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail