Bids Are invited for PRESSURE REDUCTION SKID FOR IGC TERMINAL - PRESSURE REDUCTION SKID, INPUT: 20 KG/CM2,4 IN,300#, OUTPUT: 5-12 KG/CM2,4 IN,300#, FLOW MIN/NOR/MAX-: 0.04/0.05/0.06 MMSCMD,SDV & PCV ,IGC PRS SKID(LINE SIZE-4 INCH)Required configuration as-Tripura

Ministry Of Petroleum And Natural Gas has published Bids Are invited for PRESSURE REDUCTION SKID FOR IGC TERMINAL - PRESSURE REDUCTION SKID, INPUT: 20 KG/CM2,4 IN,300#, OUTPUT: 5-12 KG/CM2,4 IN,300#, FLOW MIN/NOR/MAX-: 0.04/0.05/0.06 MMSCMD,SDV & PCV ,IGC PRS SKID(LINE SIZE-4 INCH)Required configuration as. Submission Date for this Tender is 07-01-2022. Electrical Products Tenders in Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

30163173
Corrigendum : Bids Are invited for PRESSURE REDUCTION SKID FOR IGC TERMINAL - PRESSURE REDUCTION SKID, INPUT: 20 KG/CM2,4 IN,300#, OUTPUT: 5-12 KG/CM2,4 IN,300#, FLOW MIN/NOR/MAX-: 0.04/0.05/0.06 MMSCMD,SDV & PCV ,IGC PRS SKID(LINE SIZE-4 INCH)Required configuration as
Tender
Indian
Tripura
07-01-2022

Tender Details

Bids Are invited for PRESSURE REDUCTION SKID FOR IGC TERMINAL - PRESSURE REDUCTION SKID, INPUT: 20 KG/CM2,4 IN,300#, OUTPUT: 5-12 KG/CM2,4 IN,300#, FLOW MIN/NOR/MAX-: 0.04/0.05/0.06 MMSCMD,SDV & PCV ,IGC PRS SKID(LINE SIZE-4 INCH)Required configuration as per the PNGRB guidelinesIsolation valve >Slam Shut Valve > Monitor Regulator >Active Regulator > Creep relief valve> NRV>Isolation valveMinimum pressure drop is required (Max allowable 1.5 KG/CM2 across Slam Shut Valve > Monitor Regulator>Active Regulator configuration)Flow gas Min Min/Normal/Max 5000 /16000 /60000 SCMD or MoreInlet pressure Normal/Design 20/49kg/cm2Outlet pressure Normal/Design 5-12 Kg/cm² , PRESSURE REDUCTION SKID FOR ROKHIA TERMINAL - ROKHIA PRS SKID(LINE SIZE-6 INCH)Required configuration as per the PNGRB guidelinesIsolation valve >Slam Shut Valve > Monitor Regulator >Active Regulator > Creep relief valve> NRV>Isolation valveMinimum pressure drop is required (Max 1.5 KG/CM2 across Slam Shut Valve > Monitor Regulator>Active Regulator configuration)Flow gas Min Min/Normal/Max 0.10 /0.3 /0.5 MMSCMD or MoreInlet pressure Normal/Design 20-25 Kg/cm2/49kg/cm2 ,OUTLET PRESSURE :19.3 to 20.3 KG/CM2 , PRESSURE REDUCTION SKID FOR NEEPCO TERMINAL - NEEPCO PRS SKID(LINE SIZE-10 INCH)Required configuration as per the PNGRB guidelinesIsolation valve >Slam Shut Valve > Monitor Regulator >Active Regulator > Creep relief valve> NRV>Isolation valveMinimum pressure drop is required (Max 1.5 KG/CM2 across Slam Shut Valve > Monitor Regulator>Active Regulator configuration)Flow gas Min Min/Normal/Max 0.50 /0.8 /1 MMSCMD or MoreInlet pressure Normal/Design 20-25 Kg/cm2/49kg/cm2Outlet pressure Normal/Design 20-21 Kg/cm² , INSTALATION AND COMMISSION - INSTALATION AND COMMISSION Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 22-12-2021 31-12-2021
2 30-12-2021 07-01-2022

Key Value

Document Fees
Refer document
Tender Value
INR 2.51 Crore /-