Bids Are Invited For Vrf - Part-A: Vrf Equipments:Sl.No.1.1: 8 Hp Outdoor Unit. The Outdoor Unit Shall Meet Minimum Cooling Requirement Of 7 Tr ( 21000 K Cal / Hr. ) Makes: Voltas / Blue Star / Carrier / Carrier Midea / O-General / Mitsubishi / Daikin / Eta Gree / Toshiba / Hitachi / Trane , Outdoor - Part-A Of Sl.No.2.1:8 H.P. Outdoor Unit , Min - Part-A Of Sl.No.3.1:Minimum 2.0 Tr Cassettee Type Units , Tr - Part-A Of Sl.No.3.2: Minimum 1.5 Tr Cassettee Type Units , Cordless - Part-A Of Sl.No.3.3: Supply Of Cordless Remote Controls With Lcd Display For Indoor Units. , Panel - Part-A Of Sl.No.3.4:Supply And Fixing Of Decorative Panels For Round Flow Cassettee Type Indoor Units. , Joints - Part-A Of Sl.No.4: Supply And Laying Of Suitable Refnet Joints With Suitable Insulation To Take Care Of Connectivity And Circuiting As Detailed Above And As Per Tender Drawing. , Ceiling - Part-A Of Sl.No.5.1: Vrf Ceiling Suspended Cassettee Indoor Units. , Wiring - Part-A Of Sl.No.6: Supply And Laying Of Suitable Size Of Control / Communication Wiring Ofcopper Cable Through Pvc Conduit . Scope Of Work Includes Supply And Fixing Of Pvc Conduit With Clamps Etc. , Thick - Part-A Of Sl.No.7.1: 28.6 Mm Od ( Insulation = 19Mm Thick ) , Insulation - Part-A Of Sl.No.7.2: 22.2 Mm Od ( Insulation = 13Mm Thick ) , Clamps - Part-A Of Sl.No.7.3: 19.1 Mm Od ( Insulation = 13Mm Thick ) , Supports - Part-A Of Sl.No.7.4: 15.9 Mm Od ( Insulation = 13Mm Thick ) , Bends - Part-A Of Sl.No.7.5: 12.7 Mm Od ( Insulation = 13Mm Thick ) , Pipes - Part-A Of Sl.No.7.6: 9.5 Mm Od ( Insulation = 13Mm Thick ) , Cable - Part-A Of Sl.No.7.7: 6.4 Mm Od ( Insulation = 13Mm Thick ) , Tray - Part-A Of Sl.No.8: Supply, Installation Of Gi Tray With Support For Covering Of Exposed Refrigerant Pipe. Makes: Slottco / Profab Engineer / Hi-Reach / Mm Enterprises , Gi - Part-A Of Sl.No.9.1: 32 Mm Dia , Utrap - Part-A Of Sl.No.9.2: 25 Mm Dia , Drain - Part-A Of Sl.No.10:Supply And Installation Of Press Fit Casing Capping / Pvc Trunking Of Size 100Mm * 50Mm Along The Exposed Drain Pipeline In The Recess / Surface As Required And As Directed By Nrsc. , Powre - Part-A Of Sl.No.11.1:Pvc Insulated 3C X 1.5 Sqmm Power Cable ( For Vrf Indoor Units ) , Installation - Part-A Of Sl.No.11.2:Xlpe Insulated 4C X 6 Sqmm Power Cable ( For Vrf Outdoor Units ) , Core - Part-A Of Sl.No.12: Minor Civil Works Like Foundations / Pedestals Foroutdoor Units And Core Cutting / Cutting Away, Making And Finishing Good Of Openings In Walls / Ceiling Etc.: For Passage Of Pipes, Ducts, Cables, Etc. Complete As Required. , Split - Part-B: Tower Split Ac:Sl.No.1.1:Tower Split Ac Units With Minimum 2 Tr Nominal Capacity.Makes:Voltas / Blue Star / Carrier Midea / Daikin / Hitachi / Panasonic / Mitsubishi / Toshiba / Trane / O General / Lloyd , Ac - Part-B Of Sl.No.2.1:Suction Copper Pipe Line As Per Manufacturer Recommendation. , Liquid - Part-Bof Sl.No.2.2:Liquid Copper Pipe Line As Per Manufacturer Recommendation . , Condensate - Part-B Of Sl.No.3:Supply And Erection Of Condensate Drain Pipe Made Out Of 25Mm ( 10 Kg / Cm2 ) Dia Cpvc Pipe, Water U Trap, Pipe Supports, Clamps Including Nitrile Rubber Insulation. Makes: Astral / Supreme , Rubber - Part-B Of Sl.No.4:Supply And Installation Of 75 Mm Durable Pvc Pipe With Elbows, Couplings / Reducers As An Enclosure For Refrigerant Copper Pipes To Protect Against Radiation, Rain, Wind And Other External Factors As Required And As Directed By Nrsc. , Angles - Part-B Of Sl.No.5:Supply And Installation Of Ms Angles Fabrication And All Necessary Clamps Etc., For Mounting Of Ac Outdoor Units, Plenum, Ductsas And When Required As Directed By Nrsc Etc. , Powder - Part-B Of Sl.No.6:Supply And Installation Of Suitable Height And Thickness Of Powder Coated Floor Mounted Stands For Ac Indoor Units , Earthwire - Part-B Of Sl.No.7.1:Suitable Size Of Power Cable As Per Manufacturer Recommendation , Cement - Part-B Of Sl.No.7.2 :Suitable Size Of Control Cable As Per Manufacturer Recommendation , Runs - Part-B Of Sl.No.7.3 :G.I. Earth Wire Of Two Runs Of Size 8 Swg , Conductor - Part-B Of Sl.No.8:Supply And Installation Of Covered Type Gi Tray.Makes: Slottco / Profab Engineer / Hi-Reach / Mm Enterprises , Pedestal - Part-B Of Sl.No.9:Minor Civil Works Like Making Pcc Pedestal And Core Cuttingfor Good Of Openings, Plastering, Finishing With White Cement In Walls / Ceiling Etc. For Passage Of Refrigerant Pipes, Ducts Along With Repairof Wooden Wall Panelling Complete As Required As Directed By Nrsc At Site. Total Quantity : 1