Delhi University has published Re-Erection Of Principal Bungalow Hindu College, Delhi University Re-Erection Of Principal Bungalow Hindu College, Delhi University. Submission Date for this Tender is 31-12-2021. Building Work Tenders in Hindu College, North Campus Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-Dec-2021 | Re-erection of Principal Bungalow Hindu College, Delhi University | Other | 18-12-2021 |
2 | 17-Dec-2021 | Re-erection of Principal Bungalow Hindu College, Delhi University, | Other | 31-12-2021 |
3 | 17-Dec-2021 | Re-erection of Principal Bungalow Hindu College, Delhi University | Date | 31-12-2021 |
Sl. No. | Item Description |
1 | Part I- CIVIL AND PLUMBING WORKS |
2 | Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil. |
3 | Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for alldepthincluding getting out thed soil,& then returningthe soil as required, in layers not exceeding 20 cm indepthincludingconsolidatingeachdepositedlayerbyramming,watering,etc and disposingof surplus excavated soil as directed, within lead of 50m. Allkindsofsoil. Pipes,cables etcexceeding80mmdiabutnotexceeding300 mm dia |
4 | Providing and laying in position cement concrete of specified grade INcluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
5 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. |
6 | Walls(anythickness)includingattachedpilasters,butteresses,plinthandstring courses etc. |
7 | Suspended floors, roofs, landings, balconies and access platform |
8 | Shelves (Cast in situ) |
9 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
10 | Columns, Pillars, Piers, Abutments, Posts and Struts |
11 | Stairs, (excluding landings) except spiral-staircases. |
12 | Edges of slabs and breaks in floors and walls |
13 | Extraforadditionalheightincentering,shutteringwhereeverrequiredwith adequate bracing, propping etc., including cost of de-shuttering and decentering at alllevels,overaheightof3.5m,foreveryadditionalheightof1metreorpart thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionandbindingallcompleteuptoplinthlevel.Thermo-MechanicallyTreated bars. |
15 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor V level Thermo-Mechanically Treated bars |
16 | Providing and laying in position machine batched and machine mixed design mix M 25gradecementconcreteforreinforcedcementconcretework,usingcement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, includingadmixturesinrecommended proportionsas perIS:9103to accelerate, retardsettingofconcrete,improveworkabilitywithoutimpairingstrengthand durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). |
17 | All works upto plinth level |
18 | All works above plinth level upto floor V level |
19 | BrickworkwithF.P.S.bricksofclass designation75 infoundation andplinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
21 | HalfbrickmasonrywithF.P.S.bricksofclassdesignation75insuperstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
22 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks). |
23 | Providingandfixing18mmthickgangsawcutmirrorpolishedpremouldedand prepolished) machine cut for flooring, staircase treads , riers and landings, kitchen platforms,vanitycounters,windowsills,faciasandsimilarlocationsofrequired sizeofapprovedshade,colourandtexturelaidover20mmthickbasecement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm |
24 | Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for walllining(veneerwork)includingdado,skirting,risersofsteps etc.,in required design and pattern wherever required, stones of differentinished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment ofatching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in- Charge. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. |
25 | Providing and fixing IS:3564 markedhaving brand logo with ISI embossed on the platedoorweight36KGto80KGanddoorwidthfrom701mmto1000mm aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc.complete |
26 | Providingandfixing50cmlongaluminiumkickingplate100x3.15mmanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. |
27 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm uPVC or aluminum powder coatedU beading |
28 | Extra for providing frosted glass panes5 mm thick instead of ordinary float glass panes5mmthickindoors,windowsandclerestorywindowshutters.(Areaof opening for glass panes excluding portion inside rebate shall be measured). |
29 | ProvidingandfixingfactorymadeuPVCwhitecolourcasement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thickgalvanizedmildsteelsectionmadefromrollformingprocessofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDM G.Ifasteners100x 8mmsizeforfixingframeto finishedwall, plasticpackers,plasticcapsandnecessary stainlesssteelscrews etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finishedwallshallbefilledwithweatherproofsiliconsealantoverbackerrodof requiredsizeandofapprovedquality,allcompleteasperapproveddrawing& direction ofEngineer-in-Charge.(Single /double glass panes andsilicon sealant shall be paideparately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. indepth &width of profile shallbe acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completelyfixedventilatorwithS.Sfrictionhinges(350x19x1.9)madeof(big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thicknessof2.3±0.2mmandsingleglazingbead/doubleglazingbeadof appropriate dimension. (Area of window - ANY) |
30 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50minheightdimensioncomprisingofuPVCmulti-chamberedframewithin- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick alvanizedmildsteelsectionmadefromrollformingprocessofrequiredlength (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazingbeads and uPVC extruded interlocks,EPDM gasket,wool pile,zinc alloy (whitepowdercoated)touchlockswithhook,zincalloybodywithsinglenylon rollers(weightbearingcapacity tobe40kg),G.Ifasteners100x 8mmsizefor fixingframetofinishedwallandnecessarystainlesssteelscrewsetc.Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as perapproveddrawing&directionofEngineer-in-Charge.(Single/doubleglass panes,wiremeshandsiliconsealentshallbepaidseparately)Note:ForuPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & widthofprofileshallbeacceptable.Variationinprofiledimensioninhigherside shallbeacceptedbutnoextrapaymentonthisaccountshallbemade. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
31 | Providing and fixing SS304 sliding door bolts, including all necessary screws et. |
32 | 600x16 |
33 | 450x16 |
34 | 300x16 mm |
35 | 250x16 mm |
36 | 150x16 mm |
37 | Structural steel work in single section, fixed with or without connecting plate,includingcutting,hoisting,fixinginpositionandapplyingaprimingcoatof approved steel primer all complete. |
38 | Structuralsteelworkriveted,boltedorweldedinbuiltupsections,trussesand framedwork,includingcutting,hoisting,fixinginpositionandapplyingapriming coat of approved steel primer all complete. |
39 | Steelworkweldedinbuiltupsections/framedworkincludingcutting,hoisting, fixinginpositionandapplyingaprimingcoatofapprovedsteelprimerusing structuralsteeletc.asrequired.Ingratings,frames,guardbar,ladder,railings, brackets, gates and similar works. |
40 | Providingandfixingstainlesssteel(Grade304)railingmadeofHollowtubes, channels,platesetc.,includingwelding,grinding,buffing,polishingandmaking curvature (wherever required) and fitting the same with necessary stainless steel nutsandboltscomplete,i/cfixingtherailingwithnecessaryaccessories& stainless steel dash fasteners , stainless steel bolts etc., ofrequired size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel membersshallbeconsideredexcludingfixingaccessoriessuchasnuts,bolts, fasteners etc.). |
41 | Providing&fixingglasspaneswithputtyandglazingclipsinupvcwindows, windows, clerestory windows, all complete with : 5 mm thick glass panes |
42 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab, including rubbingandpolishingcompletewithbaseofcementmortar1:4(1cement:4 coarse sand) : 25 mm Thick |
43 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
44 | 40mmthickfinedressedstoneflooringover20mm(average)thickbaseof cementmortar1:5(1cement:5coarsesand),includingpointingwithcement mortar1:2 (1 cement:2stone dust)with anadmixture ofpigmenttomatch the shade of stone. Red sand stone |
45 | Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.5 metre . |
46 | ProvidingandfixingIstqualityceramic glazedwall tilesconformingtoIS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexceptburgundy,bottlegreen,blackofsize600mmx 300mmoras decided / approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade all complete as per the directions of Engineer-in- charge. |
47 | Providingwoodworkinframesofdoors,windows,clerestory windowsand other frames,wroughtframedandfixedinpositionwithholdfastlugsorwithdash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
48 | Providing and fixing panelled or panelled and glazed shutters for doors,windows |
49 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazedshuttersfordoors,windowsandclerestorywindows(Areaofopeningfor panelinsertsexcluding portioninsidegroovesorrebatestobemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
50 | providingandfixingheavy duty ballbearingButthingesBrandName:Dorset - Size : 127 x 76 x 3 inchalongwith necessary screws |
51 | Providing and fixing door lever handle brand Dorset product name Cornus |
52 | Providing and fixing lever handle with mortice lock dorset make New antic model 8inch havey plate 6×4 hardness lock body with havey cylinder combo pack |
53 | ProvidingandfixingdoorstopperHAFELEStainlessSteelWallMountedDoor Stopper 72 mm with Screw Cover (Screws Not Seen) |
54 | Providing and fixing Hettich Door Closer with Standard arm, Fire rated, HSA 10 F: EN2/3/4 Item code: 9227816 HSA 10DEN:EN2/3/4Rack AndPinion (Symmetric) Mechanism Door Closer Finish : Silver |
55 | Providing and laying rectified Glazed Ceramic floor tiles of size 600 mm x 600 mm or as decided / approved by Engineer-in-charge (thickness to be specified by the manufacturer),of1stqualityconformingtoIS:15622,ofapprovedmake,in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1Cement:4Coarsesand),jointingwithgreycementslurry@3.3kg/sqm includinggroutingthejoints withwhitecementandmatchingpigmentsetc.all complete. |
56 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincludinggroutingthejoints withwhite cementand matchingpigmentsetc., complete.11.41.4 Size of Tile 1000x1000 mm |
57 | ProvidingandlayingPolishedGranitestoneflooringinrequireddesignand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurryandpointingwithwhitecementslurryadmixedwithpigmentofmatching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone - Base price to remain within Rs. 120 per sq.ft. including all taxes and Cartage. The selection of Granite shall be done within this range |
58 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwaterpipes conf`orming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
59 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories forunplasticisedRigidPVCrainwaterpipesconformingtoIS:13592TypeA, includingjointingwithsealringconformingtoIS:5382,leaving10mmgapfor thermal expansion. |
60 | Single tee without door 110x110x110 mm |
61 | Bend 87.5° 110 mm bend |
62 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
63 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
64 | Wallpaintingwithacrylicemulsionpaintofapprovedbrandandmanufactureto give an even shade Two or more coats on new work |
65 | FinishingwallswithDeluxeMultisurfacepaintsystemforinteriorsandexteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm |
66 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work on steel surface |
67 | Polishing wooden surface with melamine polish after sanding with sand paper no. 180 , then 320, then applying 2 coats of wood tech epoxy insulator then dent filling withwoodtechfillerthenstainingwoodtechwoodstainsinteriorsbyspraying. Then applying wood tech Melamyne coating of Asian paints brand |
68 | Providing and laying Vimzincstanding seamsystem using QuartzZintype sheetingwithspecifiedpurlinsofcoldbendzsection200x80x20x2.5items complete withall accessories, nuts , screws, cleats , plates etc. |
69 | Providing,fillingandlevellinginfloorwithAutoclavedaeratedCement(AAC) blocks |
70 | Providingandapplying12mmthick(average)premixedformulatedonecoat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. |
71 | ProvidingandlayingdesignmixcementconcreteofM-30grade,inroads/taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved&specifieddesigncriteria,providingdowelbarswithsleeve/tiebars wherever required, laying at site, spreading and compacting mechanically by using needleandsurfacevibrators,levellingtorequiredslope/camber,finishingwith requiredtexture,includingsteelformworkwithsturdyM.S.channelsections, curing,makingprovisionforcontraction/expansion,construction&longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling jointswithapprovedjointfillerandsealants,completeallasperdirectionof Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to bepaidseparately).Cementconcretemanufacturedinautomaticbatchingplant (RMC plant) i/c transportation to site in transit mixer |
72 | Extraforprovidingandmixinghardeningcompoundofapprovedqualityasper manufacturer’s specification in cement concrete. |
73 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. 16.46.1 Using grade ‘A’ sealing compound. per cm |
74 | Providingand fixingwaterclosets Jaquarcompany Florentine series Code :FLS- WHT-5953UFSM Description : Rimless Wall Hung WC with UF soft close slim seat cover,HingesandallAccessoriesSize:360x545x380mm .Itemincludesall accessories, all type of piping,white cement, sundries , brackets etc. Complete |
75 | ProvidingandfixingJaquarWashBasinAriaARSWHT39903Type:TableTop Colour:White Shape:Rectangle Dimensions:700 x 435 x 135 mm Item includes all accessories, piping, white cement, sundries , brackets etc. Complete |
76 | ProvidingandfixingP.V.C.wastepipeforsinkorwashbasinincludingP.V.C. waste fittings complete. Flexible pipe 32 mm dia |
77 | Providingandfixing600x450mmbevelededgemirrorofsuperiorglass(of approvedquality)completewith6mmthickhardboardgroundfixedtowooden cleats with C.P. brass screws and washers complete. |
78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stabilityforhot&coldwatersupplyincludingallCPVCplain&brassthreaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of EngineerinCharge.concealedworkincludingcuttingchasesandmakinggood the walls etc., |
79 | 20 mm nominal outer dia .Pipes. |
80 | 25 mm nominal outer dia .Pipes. |
81 | 32 mm nominal outer dia .Pipes. |
82 | Providingandplacingonterrace(atallfloorlevels)polyethylenewaterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank |
83 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore |
84 | Providing and fixing C.P.brassSingle Lever Basin Mixer Jaquarbrand exposed part Range :Aria Code :ARI-CHR-39233NK Description :Exposed Part Kit of Single Lever Basin Mixer Wall Mounted Consisting of Operating Lever, Cartridge Sleeve, Wall Flange, Nipple & Spout (Compatible with ALD-233N & ALD-235N) |
85 | Providing and fixing C.P. brassSingle Lever Basin Mixer Jaquar brand concealed partAlliedCode:ALD-CHR-233NDescription:ConcealedBodyforSingleLever Basin Mixer Wall Mounted, But without Exposed Parts |
86 | Providingand fixingC.P. brass Bib CockJaquar brand Range :Aria Code :ARI- CHR-39037 Description :Bib Cock with Wall Flange |
87 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of JaquarbrandAngleValvewithWallFlangePRODUCTCODE:ARI-CHR-39053 PRODUCT RANGE: ARIA |
88 | Providingandfixing healthfaucet(handshower)JaquarbrandRange:Allied Code :ALD-CHR-573 Description :Hand Shower (Health Faucet) with 8mm Dia 1.2 Meter Long Flexible Tube and Wall Hook |
89 | ProvidingandfixingexposedpartofDivertormixerJaquarbrandModel:ARI 39065K Type Of Mounting:Wall Mounted Type of Mixer:Manual No. Of Connections:2.0Connection Possible To:Spout,Overhead Shower,Hand Shower,BodyShowerDescription:SingleLeverExposedPartsKitofDivertor Consiting of Operating Lever, Wall Flange (with seals) & Button Only (Suitable for Item ALD-065) |
90 | ConcealedBodyforSingleLeverDiverter40mmCartridgeRange:AlliedCode :ALD-CHR-065NDescription:ConcealedBodyforSingleLeverDiverter40mm CartridgewithButtonAssembly,CartridgeSleeve(ButtonOnTop)Butwithout Exposed Parts |
91 | Providing and fixing Jaquar Round Shape Multi Flow Hand Shower HSHCHR1939 byJaquarFeaturesProductType:OverheadShowerSize:100mmFinish: Chrome Shape : Round Material : ABS. The item to be executedinclusive of all types of piping and allied parts. |
92 | Providing and fixing Jaquar brand Overhead Shower Range :Rain Showers Code :OHS-CHR-35497Description:OverheadShower200X200mmSquareShape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System.Theitemtobeexecutedcompletelyinclusiveofalltypesofpipingand allied parts. |
93 | Jaquar Concealed Flush Tank JCS WHT 2400WS Brand Jaquar ModelJCS WHT 2400WSFinishWhite TypeOfInstallationConcealed TypeOfMountingWall Mounted TypeofFrameHalfFrameFlushTypeMechanical SuitableForWall HungWCDescriptionSinglepieceslimconcealedcisternwithwallmounting frame, installation kitand "S-Type"drain pipe connection setfor inclusive ofwall hung WC oflush control plate The item to be executed completely inclusive of all types of conncting piping and allied parts. |
94 | Providing and fixing Jaquar Artize Soap Dish Holder Brass Chrome Plated Range :Kubix Prime Code :AKP-CHR-35731P Description :Soap Dish Holder |
95 | Providing and fixing Jaquar Towel Rack Hotelier Series AHS 1581H JaquarModel AHS 1581H Location of Use Shower AreaSeries Hotelier Finish Chrome COMBINEDDIMENSIONS600x250mmModelFinCode AHS-CHR-1581H DESCRIPTION Towel Rack With Lower Hanger (Stainless Steel) With Hook |
96 | PROVIDINGANDFIXINGJaquarTowelRingSquareContinentalSeriesACN 1121N Brand JaquarModel ACN 1121N Location of Use BasinSeries ContinentalFinishChromeCOMBINEDDIMENSIONS210x210mmModelFin Code ACN-CHR-1121NDESCRIPTION Towel Ring Square With Round Flange |
97 | Providingandfixingsquare-mouthS.W.gullytrapclassSP1completewithC.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be notless than 2.70 kgas perstandard design :150 x 100 mmsize P type. With sewer bricks conforming to IS : 4885 |
98 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportionof 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe |
99 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement:4coarsesand(zone-III):8gradedstoneaggregate40mmnominal size), inside plastering 12 mm thick with cement mortar 1:3 (1ement : 3 coarse sand) finished with floating coat of neat cement and making |
100 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster12 mmthick with cement mortar1:3 (1 cement :3 coarse sand) finished with a floatingcoatofneatcement,foundation concrete 1:3:6 mix (1 cement: 3 coarsesand:6gradedstoneaggregate40mmnominalsize),andmaking necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame heavy duty, HD-20 grade designation) 560 mm internal diameteronforming to I.S. 12592, total weight of cover and frame to be notless than 182 kg., fixed in cement concrete1:2:4(1cement:2 coarsesand:4gradedstoneaggregate20mm nominal size)including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
101 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar1:4(1cement:4coarsesand)including500x450mmpre-castR.C.C. horizontal grating with framecomplete as per standard design : bricks in cement mortar1:4(1cement:4coarsesand)withprecastR.C.C.verticalgrating completeasperstandarddesign:19.28.1WithcommonburntclayF.P.S.(non modular)bricksofclassdesignation7.5 WithcommonburntclayF.P.S.(non modular) bricks of class designation 7.5 |
102 | Providingandlayingintegralcementbasedwaterproofingtreatmentincluding preparationofsurfaceasrequiredfortreatmentofroofs,balconies,terracesetc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining wallsupto300mmheightincludingcleaningthesurfacebeforetreatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with50%ofcementmortar1:5(1cement:5coarsesand)admixedwithwater proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over20 mmthicklayerofcementmortarofmix 1:5 (1 cement:5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days ofpropercuringapplyingasecondcoatofcementslurryusing2.75kg/sqmof cementadmixedjointlesscementmortarofmix1:4(1cement:4coarsesand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and makingpatternof300x300mmsquare3mmdeep.e)Thewholeterraceso finished shall be flooded with water for a minimum period of two weeks for curing andforfinaltest.Allaboveoperationstobedoneinorderandasdirectedand specifiedbytheEngineerin-Charge: Withaveragethicknessof120mmand minimum thickness at khurra as 65 mm. |
103 | Providing and fixing soil, waste and vent pipesin uPVC SWR pipings including all fittings with or without doors . Only length is to be measured from GT , Manhole to Cowl or fittings. 110 mm dia |
104 | ProvidingandFixingDelhiquatrzstonecladding ofapprovedquality approximately in 9"x9"x4" stone sizes in approved irregular pattern with around 10 mmth.Grooveslaidwith1:4Cement,badarpur/coarsesandmortar ,with recessed pointing in 1:2 Cement sand mortar in approved design. The work shall be done as per approved sample and any deviation shall have to be rectified at the risk and cost of the contractor. The cladding shall be done on the walls , in floors and on steps |
105 | P/F CPVC union approved make CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge. |
106 | 25 mm nominal bore |
107 | 32 mm nominal bore |
108 | P/F CPVC ball valve (gate valve) of approved make in CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge. |
109 | 25 mm nominal bore |
110 | 32mm nominal bore |
111 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length and 15 mm nominal bore |
112 | Providing and fixing CP Grating Square Grating, Size: 5" X 5"SS304 Brand Onida Shape Square Material Stainless Steel Size 5" x 5"/6" x 6" Cat No 60/3025 Model No 5120/5121 125 mm nominal dia with 25 mm waste hole/without hole |
113 | Extra forlapatto finishGranite in lieu of polished granitein item 11.56 |
114 | Extra for providing 8 mm th float glass in place of 5 mm th glass in Item 34 |
115 | Extra for providing 3-4mm Grout joint in tileswith letticrete epoxy grout |
116 | Extraforprovidingandfinishingsuperiorexposedbrickworkincluding recessed pointing as in existing Girls hostel as per approval |
117 | Extra for using shuttering ply in the soffits of slabs to achieve exposed RCC finish in addition to Item4 c |
118 | Filling and compaction with Construction debris available at the College within 500 m Lead. |
119 | Core cutting in RCC slabs upto 200 mm thickness from 75mm to 162 mm dia for plumbing pipes |
120 | Core cutting in RCC beams upto 300 Thicknessfrom 75mm to 162 mm dia for plumbing pipes |
121 | PART – II ELECTRICAL WORK |
122 | Wiring for light point/fanpoint/exhaust fan point/call bell pointwith 1.5Sq.MmFRLS PVC insulated copperconductor single core cablein surface / recessedmedium class PVCconduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required:Group A |
123 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.:Group A |
124 | Wiring for twin control light pointwith 1.5 Sq.Mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required. |
125 | Wiringforpowerplugwith 2 x 4 Sq.Mm. FRLS PVCinsulated, copperconductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no 4 Sq.Mm FRLS PVC insulated copper conductor single core cable forloopearthing as required. |
126 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
127 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
128 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
129 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
130 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
131 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
132 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
133 | Providingand fixing hexagonal fan boxcircular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
134 | Supply and drawing followingpair, 0.5 sq.mm. FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required.2 Pair |
135 | 2 Pair |
136 | Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required:1 or 2 Module (75 mm x 75 mm) |
137 | Supplying and drawing co- axial TV cable RG-11 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinnned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. |
138 | Supplying and fixing of following sizes of medium classPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
139 | 20mm |
140 | 25 mm |
141 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
142 | 15/16 amp switch |
143 | 6 pin 15/16 amp socket outlet |
144 | Telephone socket outlet |
145 | TV antenna socket outlet |
146 | Bell Push |
147 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
148 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
149 | 1 or 2 Module (75mm x 75mm) |
150 | 8 Module (125mm x 125mm) |
151 | 12 Module (200mm x 150mm) |
152 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. |
153 | 1 or 2 Module |
154 | 8 Module |
155 | 12 Module |
156 | SITC of10 watt mirror light fixture made of extruded aluminium housing suitable for 220 Volt AC with system lumens output of2000 or higher colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd. |
157 | SITC of 1200mm (Nominal Size) LED luminaire of36-40 wattmade of extruded aluminium housing suitable for 220 Volt AC with system lumens output of2000 or higher colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd. |
158 | SITC of 12-15WLED Recessed Downlighter with a nominal system lumen output of 1300 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 Complaint,new backlit design . The luminaire should have a color temperature between 4000K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance etc complete as reqd. |
159 | SITC of 12-15WLED surface Downlighter with a nominal system lumen output of 1300 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 Complaint,new backlit design . The luminaire should have a color temperature between 4000K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance etc complete as reqd. |
160 | Supplying, Installation, Testing and Commissioning ofsurface mounting IP-65, 10 Watt LED bulk head light fitting with polycarbonate diffuser, single phase, 100-270V AC, effiicacy 100 Lumens/ watt complete with integral electronic driver etc complete as reqd. |
161 | SITC of LED flood light fixture suitable for 70 Watt for area lighting. Optical system of high-quality UV and temperature-resistant optical lens systems with rotationally symmetrical light distribution. Floodlight housing of die-cast aluminum, powdercoated, highly weather resistant. Luminaire luminous flux 6000lm, luminous efficiency of luminaire 100 lm/W. correlated colour temperature (CCT) 6500 K, general colour rendering index (CRI) Ra > 70. Service life L70(tq 25 °C) = 50,000 h. IK05/0,2 J, P.F>0.95, THD<10%, Protection IP65 etc complete as reqd. |
162 | Providing and fixing ofLED bollard luminaire of 10 Watt of height minimum 582mm as required, correlated colour temperature (CCT) 6000 K,operating voltage 120-277V. Impact resistance IK10 with LDPE protector. Service life L70(tq 25 °C) = 50,000 h.surge protection upto 10KV, Protection IP66 etc complete as reqd. |
163 | SITC OF BED LAMP FITTING switable for BC / EC LED lamp made out of stainless steel housing with antique finish with rotating neck etc as per requried . |
164 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
165 | Supplying, Installation, Testing and Commissioning of following sizes Heavy duty Exhaust Fan with Aluminium Louvers including connection with 3 core PVC insulated PVC sheathed flexible copper conductor cable on the existing window opening / Structure / Box complete etc. as required :300 mm sweep 900 rpm.The exhaust fan shall be fixed on minimum 10 mm thick bakelite sheet having suitable opening for exhaust fan. |
166 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
167 | SITC of free standing floor mounted dust and vermin proof compartmentalised IP54cubical panels made out of CRCA sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panels in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment /switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure.Also TP&N aluminium busbar for 300 Amps of suitable rating for connections and other required Accessories. All complete as per CPWD specifications anddirection of Engineer-in-charge.(Panels shall be TTA approved) (Including voltmeter,ammeter,indication lamp,CT,setector switch) |
168 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
169 | 100 A, 16 KA,TPMCCB |
170 | 63Amp DPMCB |
171 | Supplying of following sizes one number XLPE insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV gradeUG Cable etc complete as required |
172 | 4 x 25Sqmm |
173 | 2X16 sqmm |
174 | 2X10 Sqmm |
175 | 3.5X50 sqmm |
176 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
177 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
178 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
179 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
180 | 4 X 25 sq. mm (28mm) |
181 | 2 X 10 sq. mm (19mm) |
182 | 2 X 16 sq. mm (22mm) |
183 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
184 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
185 | 8 way double door |
186 | 12 way double door |
187 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C" series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required:single pole |
188 | Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
189 | Single pole |
190 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required:63 Amps |
191 | Supply and fixingmodular type A/C box complete with 16amp socket outlet6 to 32 amp SPMCB, cover plate,connection testing and fixing etc as reqd |
192 | SITC of 1.5 Tr capacity air conditioner, 5 star rated Inverter type having only cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supplywith ecofriendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater) |
193 | SITC of 1.5 Tr capacity air conditioner, 5 star rated Inverter type having only cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supplywith ecofriendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater) |
194 | Supplying, Installation and welding the copper pipe with the existing pipe of 1.5 TR /2.0 TR refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping insidethe room shall be properly supported with M. S. hanger / angles / clamping arrangement, dash fasteners suitably run on existing cable tray etc. as required. |
195 | Supplying and Laying of one number 3 core 1.5/2.5 sqmm pvc insulated and pvc sheathed round wire on wall/surface/with refrigerant pipe etc for AC. |
196 | 3 c (2.5 sqmm) Electrical wiring from MCB to outdoor units (BIS) |
197 | 6 sq mm Electrical wiring from MCB to outdoor units as / BIS |
198 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 25 mm nominal outer dia Pipes- recessed in walls |
199 | Voltage stabilizers 4 KVA forA/C |
200 | SITC of 1.5TR AC Outdoor unit powder coated standrequired as per site condition wall / Floor Mounted. |
201 | Comprehensive Annual Maintenance of1.5 Tr capacity Inverter type Split AC as per manufacturer recommendation including servicing of the AC ,Refrigerant gas charging , replacement of compressor, motor,wiring,etc complete with all parts required for healthy and proper functioning of the Air Conditioning.(Nothing will be provided by the department during the period) |
202 | Year 1 (after Defect Liability Period of One Year) |
203 | Year 2 |
204 | Year 3 |
205 | Year 4 |
206 | Year 5 |
207 | Supply and fixing of Gyeaser/ water heater 25 Ltrs capicity complete as read (Make:-Hevells - WB025 or eqvialent Recold/Smith) |
208 | Supply installation testing and commissioning R.O.water purifier (Kent Grand 8 L RO + UV +UF Water Purifier(White) |
209 | Supplying, installing, testing & commissioning of Domestic Water Lifting Pumps to feed Overhead Tank. (1HP) including all fittings as per direction of Engineer-in- charge.Location - Near underground water tank Part III Miscellaneous |
210 | If there are any extra items which are not covered in items given above they shall be paid at a fixed percentage below or above DSR 2018as per the percentage decided in the beginning. Please quote the net percentage rate here . For example if the contractor wants to quote 5% below DSR2018 please fill .95 .So that amount shall become Rs.9,50,000.0 |