Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantlingcementconcreteorbrickorgranolithicfloorsincluding stackingofdismantledmaterialsasdirectedbyEngineer-In-Charge within a distance of 60 meters (200 feet). |
| 2 | Dismantling reinforced cement concrete or reinforced brick work including stacking of dismantled materials as directedby Engineer-In- Charge within a distance of 60 meters (200 feet). |
| 3 | Dismantlingbrickworkorstoneworkinlimeorcementmortarand including stacking of materials asdirected byEngineer-In-Charge within a distance of 60 meters (200 feet). |
| 4 | Excavation in foundation in ordinary soil (Loam, Clay or Sand) Includingliftupto1.50mandleadupto30mandincludingfilling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer In-charge upto a distance of 30m from the foundation |
| 5 | Providingandlayingincementconcrete1:4:8(1cement:4Coarce sand :8 graded brick ballast 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 6 | Sand filling in plinth under floors including watering, ramming, consolidating and dressingcomplete includinglead upto 50mand lift upto 1.5m and including cost of sand. |
| 7 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter ofbindingexpansionjoints,surroundingofpipesandconduitsetc, complete(plinthareaofthebuildingatgroundflooronlyshallbe measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrateoranyotherapprovedmaterialsuchasHeptrachloror Chlordanewillbeused.Therateofapplicationofchemicalemulsion shall beasfollows :(1) Treatmentfor masonary & foundation5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 8 | R.C.C.workwithcementapprovedcoarsesandand20mm.guage approvedstonegritimtheproportionof1:1.5:3inBeamexcluding supplyofreinforcementanditsfixingandbindingthesamewith24 BWGbindingwireandincludingnecessarycenteringandshuttering etc.andalsoincludingsupplyofallmaterials,labourandtoolsand plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 9 | R.C.C.workwithcementapprovedcoarsesandand20mm.guage approvedstonegritimtheproportionof1:1.5:3inslabexcluding supplyofreinforcementanditsfixingandbindingthesamewith24 BWGbindingwireandincludingnecessarycenteringandshuttering etc.andalsoincludingsupplyofallmaterials,labourandtoolsand plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 10 | R.C.C.workwithcementapprovedcoarsesandand20mm.guage approved stone grit im the proportion of 1:1.5:3 in foundation excluding supply of reinforcement and its fixing and binding the same with24BWGbindingwireandincludingnecessarycenteringand shutteringetc.andalsoincludingsupplyofallmaterials,labourandtoolsandplantsetc,requiredforpropercompletionoftheworks. strength of the concrete shall not beless than M-20. |
| 11 | R.C.C.workwithcementapprovedcoarsesandand20mm.guage approvedstonegritimtheproportionof1:1.5:3incolumnexcluding supplyofreinforcementanditsfixingandbindingthesamewith24 BWGbindingwireandincludingnecessarycenteringandshuttering etc.andalsoincludingsupplyofallmaterials,labourandtoolsand plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 12 | Class-150(NonModular)brickworkin1:6cementandCoarsesand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 13 | Brick workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick workas required andalsoincludinghoneycombedbrickworkin thickness of wall more than 12cms. |
| 14 | Same as in item no. 14 but in1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 15 | P/FMildsteelorironinplainworksuchasreinforcedconcreteor reinforced, brick work (when not included in over all rates ) wrought to requiredshapeasnecessary includingbendingforpropercompletion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 16 | 15 mm cement plaster in single coat on faire side of single or half brick wallfor interior plastering up to floor two levelincluding internal roundedanglesnotexceeding80mmingirthandfinshedevenandsmooth. (1) 1 cement : 6 Coarse sand |
| 17 | 12 mm cement plaster in single coat on faire side of single or half brick wallfor interior plastering up to floor two levelincluding internal roundedanglesnotexceeding80mmingirthandfinshedevenand smooth. (1) 1 cement : 6 Coarse sand |
| 18 | 6mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor twolevel. |
| 19 | Making grooves 10 to 12mmwide x8mm deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 20 | Providing and laying Vitrified tiles in floor of600x 600mmsizes (thickness 10mm), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in desired coloursandshades,laidwithcementbasedhighpolymermodified quick set tile adhesive (water based) conforming to IS : 15477,including grouting of joints. |
| 21 | (a) P/L 18mm Black Granite stone (super quality) flooring over 25mm thickbaseofcementmortar1:4(1 cement: 4coarse sand)laid and jointed with white cement slurry including rubbing and polishing complete. |
| 22 | S/F Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard,jointedwithneatcementslurrymixedwithpigmentto match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 23 | Supply&fixing5mmthickChinawhiteglazedtilesinflooringorin skirtingordadolaidwith1:3(1cement:3coarsesand)andjointed with white cement (with pigment) slurry including rubbing and polishingof joints etc. complete. |
| 24 | Mildsteelorironworkofsmallsizesandsectionssuchasholding downbolts,holdfasttierods,gratingsetc.(whennotincludedinan over all rates) wrought to required from including supply of steel and its wastageincludingcostofbolts,nutsifrequiredforandwelding, grinding and making holes as required completion of work fabrication of holesdoors,chaukhatsnosing.Fabricationofholdfast fordoorchaukhats and windows. |
| 25 | Fabricationof grill / railing. |
| 26 | Fabrication of Z-section steel windows. |
| 27 | Supply of M.S. Steel 18 gauge (1.25mm) pressed steel door chaukhat including S/F of iron hinges of 100x3 mm I.S.I. Mark with drilling holes for L-drop and pipes 15x12mm cleats for tower bolt and 40x6 mm hold fast 230mm long including supply of all materials, labours T&P carriage upto site required for proper completion of work as per direction of E/I. |
| 28 | Supply and fixing of flush doors commercial quality conforming to I.S. 2202 Part I (1483) including fixing of wooden cleats and stoppers and includingixingandadjustmentofhinges,bolts,locks,handle,springs and other fittings but excluding their supply and including painting with twocoatsofBlackJapanpaintonallironfittingifnecessary.Fitting with necessary screws to be supplied departmentally. (a) 32mm thick |
| 29 | Same as above & Extra for providing lipping with 2nd class teak wood battens25mmminimumdepthonalledgesofflushdoorshutters(over all area of door shutter to be measured). |
| 30 | Providing&Fixing1.00mmthickdecorativehighpressurelaminated sheetofplain/woodgrainingloss/matt/suedefinishwithhigh density protective surface layer and reverse side of adhesive bonding ualityconformingtoIS:2046TypeS,includingcostofadhesiveofapproved quality. |
| 31 | Providingandfixingglazinginaluminiumdoor,window,ventilator shuttersandpartitionsetc.withEPDMrubber/neoprenegasket etc. complete as per the architecturaldrawings and the directionsof engineer-in-charge 4.0 MM THK GLASS |
| 32 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width ofaperture1.4mminbothdirectionswithwireofdia.0.50mmall complete. |
| 33 | Wall painting (one coat) with plastic emulsion paint of approved brand andmanufactureondecorativewallsurfacetogiveanevenshade including thoroughly brushing the surface clean all of dirt, grease loose pieces and prepare smooth. |
| 34 | Finishingwallswithapaxpaintofapprovedmakesuchassuper snowcem,durrocem,robiacem,guttucem,supercemqualityandof requiredshadeonundecoratedwall surfaces(twocoat)overoneand includingonecoatwhitecementprimertogiveanevenshadeafter thoroughly brushing the surface to powdered materials including curing and cost of all materials. |
| 35 | FinishingwallswithPuttyapprovedbrandandmanufactureandof required shade and undacorated wall surface to give even shade over including curing and costof all material,labour,T&P etc.required for proper completion of work. |
| 36 | Providing&fixingaluminiumslidingdoorboltsISImarkedanodised (anodic coating not less than grade AC 10 as per IS : 1868) transparentor dyed to required colouror shade with nuts and screwsetc complete. (a) 250mm x 16mm |
| 37 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coatingnotlessthangradeAC10asperIS:1868)transparentor dyed to required colour or shade with necessary screws etc complete.(a) 200 mm x 10mm |
| 38 | Providing&fixingaluminiumhandlesISImarkedanodised(anodic coatingnotlessthangradeAC10asperIS:1868)transparentor dyed to required colour or shade with necessary screws etc. complete.(a) 150 mm x 10mm dia |
| 39 | Cementconcrete1:2:4(1cement:2coarsesand:4gradedstone aggregate 12mm nominalsize forprecast unitasbed blockgap, pressedsteelchaukhatfillingandforholdfastM-15concreteetc.including all materials, T&P. etc. complete. |
| 40 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion ofthe work. |
| 41 | Same as item 35 above but on new wood surface. |
| 42 | Providingandlayingintegralcementbasedwaterproofingtreatment includingpreparationofsurfaceasrequiredfortreatmentofroofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with waterproofingcompoundconformingtoIS.2645andapprovedby Engineer-in-chargeovertheRCCslabincludingadjoiningwallsupto 300mm height including cleaning the surface before treatment. |
| 43 | Providinggola75x75mmincementconcrete1:2:4(1cement:2 coarsesand:4stoneaggregate10mmanddowngauge)including finishingwithcementmortar1:3(1cement:3finesand)asperstandard design : In 75x75mm deep chase. |
| 44 | Supplyingandfixingrolling shuttersof approvedmake, madeof required size M.S. laths, interlocked together through their entire length andjointedtogetherattheendbyendlocks,mountedonspecially designedpipeshaftwithbrackets,sideguidesandarrangementsfor insideandoutsidelockingwithpushandpulloperationcomplete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conformingtoIS:4454-part1andM.S.topcoverofrequired thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 45 | Providing and fixing ball bearing for rolling shutters. |
| 46 | Providingandfixinginpositioncollapsiblesteelshutterswithvertical channels20x10x2mmandbracedwithflatirondiagonals20x5mm size,withtopandbottomrail of T-iron40x40x6 mm,with 40mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 47 | PLUMBING WORKProvidingandfixingwhitevitreouschinapedestaltypewatercloset (EuropeantypeW.C.pan)withseatandlid,10litrelowlevelwhiteP.V.C.flushingcistern,includingflushpipe,withmanuallycontrolled device(handlelever),conformingtoIS:7231,withallfittingsand fixturescomplete,includingcuttingandmakinggoodthewallsand floors wherever required: W.C. pan with ISI marked white solid plasticseat and lid |
| 48 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillartaps,32mmC.P.brasswasteofstandardpattern,including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls whereverrequire:hiteVitreousChinaWashbasinsize630x450mm with a pair of 15 mm C. P. brass pillar taps |
| 49 | Providingandfixingwhitevitreouschinaflatbackhalfstallurinalof size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittingsand cuttingand makinggood thewalls andfloors wherever required:Singlehalfstallurinalwith5litreP.V.C.automaticflushing |
| 50 | SOIL WASTE & VENT PIPES AND FITTING -IIProviding and fixingPVCpipeconforming toIS makeworkingpressure6Kg/SqCmincudingtestinglabourT&Pandallcomplete fittings 100mm dia. |
| 51 | 75mm dia. |
| 52 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 53 | Providing and fixing trap of self cleansing design with screwed down or hingedgratingwithorwithoutventarmcomplete,includingcostof cuttingandmakinggoodthewallsandfloorsSandcastironS&Sasper IS - 3989 100 MM inlet and 100 mm out let |
| 54 | Providing and fixing mirror of superior glass (of approved quality) and ofrequiredshapeandsizewithplasticmouldedframeofapproved makeandshadewith6mmthickhardboardbacking:Rectangular shape 1500x450 mm |
| 55 | WATER SUPPLY PIPES AND FITTINGS - IIIProvidingandfixingChlorinated PolyvinylChloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.55.1 a) 16mm dia nominal bore |
| 56 | b) 20mm dia nominal bore |
| 57 | b) 40 mm dia nominal bore |
| 58 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. 15 mm nominal bore |
| 59 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 60 | ProvidingandfixingC.P.brassstopcock(concealed)ofstandard designandofapprovedmakeconformingtoIS:8931.15mmnominal |
| 61 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 62 | Providing and fixing brass stop cock of approved quality:15mm nominal bore |
| 63 | ProvidingandfixingStainlessSteelgratingofapprovedqualityand colour.125 mm dia |
| 64 | SCHEDULE OF QUANTITIES FOR INTERNAL & EXTERNAL SEWERAGE SYSTEM - IVExcavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & thenreturningthesoilasrequired,inlayersnotexceeding20cmin depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within alead of 50m. a) Pipes 80mm to 300mm diameter. |
| 65 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than4.50kgandframetobenotlessthan2.70kgasperstandard design:150 x 100 mm size P type |
| 66 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank,ISI:12701marked,withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 67 | ELECTRICALWiring point for light with 1.5 sq.mm.FRLSHPVCinsulated multistrand single core copper conductor cable inPVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cableas earthwiredrawninsidetheconduit.,GPBox, pianotypeswitch& ceilingrose/angle/battenholderon3mmthick phenoliclaminated backelitesheetetc.,completeinallrespect,asdirectedincludingmatching colour wash. |
| 68 | Wiringpointforfan/feshairfan(lightdutyexhaustfan)with1.5 sq.mm. FRLSHPVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable asearthwiredrawn insidethe conduit,GPBox,pianotypeswitch&ceilingroseon3mmthick phenolic laminatedbackelite sheet etc complete in all respect,including matching colour wash. |
| 69 | Add for light / fan points with modular type switch in place of piano typeswitch. |
| 70 | Wiring point for plug with 1.5 sq. mm.FRLSHPVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 sq.mm.FRLSHPVC insulatedmultistrandcopperconductorcableas earthwiredrawninsidetheconduit,GPBox,pianotype switch and socket etc. complete in all respect including matching colour wash. |
| 71 | Add for plug point with modular switch & socket in place of piano typeswitch & socket. |
| 72 | Supplyandfixingofpowerplugwith20Amp./250volt flushtype modularswitchand5pin20A/250voltflushtypeuniversalmodular socket switch onconcealed M.Sbox includingsupply ofall material,labour T&P etc. required for proper completion of work. |
| 73 | S/Fof Computerpointwith 1no.powerplug15Amp/250Voltflush typeswitchand5pin15 A/250volt flushtype universalsocket combined and 2No.5Amp.5pinplugwithswitchandsocketon concealedM.S.boxincludingsupplyofallmaterial,labourT&Petc,required for proper completion of work for Computer. |
| 74 | Supply andfixingofelectronicfanregulator(Modular)120-280V.ISI marked,ontheexistingswitchboardincludingmakingconnections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. |
| 75 | Supply and fixing ofLED Tube Light batten fittingsuitable for up to 1 X 22 watt LED tube light on surface complete in all respect. |
| 76 | Supplyandwiringofsubmainwithtwonumber 2.5 sq.mm.FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cablein20 mm dia heavy duty(2mmthick)PVCconduitwith1 number 1.5 sq. mm.FRLSH PVC insulated 1100 V grade multistrand single core copper conductoras earth continuity wire., complete in all respects includingmatching colour wash etc. complete in all respect. |
| 77 | Supply and wiring of submain withtwo number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one No. 2.5 sq. mm. FRLSH PVC insulatedmultistrand copper conductor cable as earthcontuiitywiredrawninconduitincludingmatchingcolourwashetc., complete in all respect. |
| 78 | S&Fsurface/Flushmounting4waysVTPNdistributionboardwithadditional metal doorwithout MCB complete in all respect,as directed at site byEngineer in charge. |
| 79 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve |
| 80 | S&F of 6 Amp. to 32Amp. 4 pole MCB (10 KA) C Curve. |
| 81 | S&Fof32Amp.fourpolechangeoverswitchon25mmx25mmx 3mm angle iron frame, including the cost of labour, T&P, painting and othermaterialrequiredforpropercompletionoftheworkasper direction and satisfaction of Engineer in charge. |
| 82 | Supplyandfixinghexagonal/RoundG.P.fanboxofapprovedmake madeupof1.0mmthick ISI Marked G.P.sheetspot weldedFour to Eight holesof25.4mmforpipeentry ofthebox.Holesshouldbe semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mmround zink coted M.SBar X 12 mm& brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
| 83 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia12mm,outerGI pipeof16swgandinnerGI pipeof12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x3mmG.I.strip,uptoswitchboard(fromaprontoswitchboard,the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.. |
| 84 | Supplyandfixingofonenumber8SWGG.I.wirein15mmdia.G.I. pipe for earthing, laid in ground or in wall duly concealed including the costofcement,sand,labour,T&Pothermaterialrequiredforproper completion of the work as directed at site. |
| 85 | Erectionandtestingofceilingfanandregulatorforroomheightupto3.5metresincludingsupplyof3mmthickG.I.Pipe19mmdia.Duly painted, complete in all respect. |
| 86 | Supply of ceiling fans BEE 5 Star rated-1200mm sweep with fan motor ofA.Cpermanentinsulation,capacitorratingconfirmingBEE5star ratingandIS:374/79andalsocomplywithIS:1709/1984withlatest amendment.Theratedvoltge220/240volts,50Hz,1-phACthefan assembleshouldconsistsofdownrodblades,shacklecanopiesetcand with double ball bearing system. |
| 87 | LED Bulb 9W (EESL) |
| 88 | Exhaust Fan 300mm (As per rate list, Havelles or equivalent) |
| 89 | [ RAINWATER HARVESTING]PART ARECHARGE WELLEarthworkinexcavationbymechanicalmeans(Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth.1.5minwidthaswellas10sqmonplan)including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m depth |
| 90 | In all kind of soil upto 1.5m to 3.0m. Depth |
| 91 | In all kind of soil upto 3.0m to 4.5m. Depth |
| 92 | In all kind of soil upto 3.0m to 4.5m. Depth |
| 93 | Providingandlayingincementconcrete1:4:8(1cement:4 coarse sand :8 graded Stone aggregate 40 mm nominal size) andcuringcomplete,includingcostofform-work,infoundation and floors. |
| 94 | M-150brickworkin1:4(onecementandsixcoarsesand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 95 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab and windows excluding supply ofreinforcement and its fixing and binding the same with 24 BWG binding wire and including necessarycenteringandshutteringetc.andalsoincluding supplyof allmaterials, labourandtools andplantsetc, requiredforpropercompletionoftheworks.strengthofthe concrete shall not beless than M-200. |
| 96 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastagebendhooksandauthorisedoverlappingshallbe measured upto floor two level. |
| 97 | 15 mm cement plaster in single coat on rough side of single or halfbrickwallforinteriorplasteringuptofloortwolevel includinginternalroundedanglesnotexceeding80mmin girth and finshed even and smooth.(1) 1 cement : 4 Coarse sand |
| 98 | ProvidingM.S.footrestsincludingfixinginmanoholeswith 20x20x10cmcementconcreteblocks1:3:6(1cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 99 | ProvidingandfixinginpositionprecastRCCmanholecover and frame of required shape and approved quality.M.D. -10- Circular shape 560mm internal diameter |
| 100 | Boring/drillingborewellofrequireddiaforcasing/strainer pipe,bysuitablemethodprescribedinIS:2800(partI), includingcollectingsamplesfromdifferentstrata,preparing and submittingstratachart/bore log,including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer- incharge, upto 90 metre depth below ground level.Drilling of 300mm dia bore hole manually. |
| 101 | Supplying, assembling, lowering and fixing in vertical position inborewellunplasticizedPVCmediumwellscreen(RMS) pipeswithribs,conformingtoIS:12818,includinghire& labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia |
| 102 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. |
| 103 | Supplying, filling, spreading & leveling gravels of size range 5 mmto10mm,intherechargepit,overtheexistinglayerof boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 104 | Supplying,filling,spreading&levelingcoarasesandofsize range1.5mmto2mminrechargepit,inrequiredthickness overgravellayer,forallleads&lifts,allcompleteasper direction of Engineer-in-charge. |
| 105 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 106 | PART BDESILTING CHAMBEREarthworkinexcavationbymechanicalmeans(Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth.1.5minwidthaswellas10sqmonplan)including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m depth |
| 107 | In all kind of soil upto 1.5m to 3.0m. Depth |
| 108 | In all kind of soil upto 3.0m to 4.5m. Depth |
| 109 | Providingandlayingincementconcrete1:4:8(1cement:4 coarse sand :8 graded Stone aggregate 40 mm nominal size) andcuringcomplete,includingcostofform-work,infoundation and floors. |
| 110 | M-150brickworkin1:4(onecementandsixcoarsesand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 111 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab and windows excluding supply ofreinforcement and its fixing and binding the same with 24 BWG binding wire and including necessarycenteringandshutteringetc.andalsoincluding supplyof allmaterials, labourandtools andplantsetc, requiredforpropercompletionoftheworks.strengthofthe concrete shall not beless than M-200. |
| 112 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastagebendhooksandauthorisedoverlappingshallbe measured upto floor two level. |
| 113 | 15mm cement plaster on rough side of single or half brick wall mix 1:4 (1 cement : 4 coarse sand) |
| 114 | ProvidingM.S.footrestsincludingfixinginmanoholeswith 20x20x10cmcementconcreteblocks1:3:6(1cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:With 20x20mm square bar |
| 115 | ProvidingandfixinginpositionprecastRCCmanholecover and frame of required shape and approved quality.Rectangular shape 900x600 mm internal dimension. |
| 116 | PART CDRAINAGE NETWORKConstructing masonry Chamber 60x60x75 cm inside, in brick workincementmortar1:4(1cement:4coarsesand)for sluicevalve,withC.I.surfacebox 100mmtopdiameter,160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mmthick,finishedwithafloatingcoatofneatcement complete as per standard design :Withcommon burntclay F.P.S.(nonmodular) bricksof class designation 7.5 |
| 117 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cmindepthincludingconsolidatingeachdepositedlayerby ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depthPipes 80 mm to 300 mmdiameter |
| 118 | Providingand layingnon-pressure NP2class (light duty) R.C.C.pipeswithcollarsjointedwithstiffmixtureofcement mortarintheproportionof1:2(1cement:2finesand) including testing of joints etc. complete :a) 150mm diameter |
| 119 | Providing&layingcementconcrete1:5:10(1cement:5 coarse sand :10 graded stone aggregate 40mm nominal size) alroundS.W.Pipesincludingbedconcreteasperstandard design.150mm diameter |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy