| 1 | Dismantlingtiled roofing(mangaloreorpotor countrytiles)withbattensetc.complete including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 2 | Dismantlingwoodworkofsectionalarea40 sq.cm.andabovewroughtframedandfixedin frames, other frames and trusses including stackingofmaterialwithin50mts.lead(span upto 10 mtrs.) |
| 3 | Steel work in built up tubular (round, square or rectangularhollowtubesetc.)(SquareHollow Section(SHS)IS4923/RectangularHollow Section(RHS)IS4923/CircularHollowSection (CHS)IS1161closedStructuralSteelof(SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (MinYeildStress310Mpa))trussesetc., including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer,includingweldingandboltedwith special shaped washers etc. complete. |
| 4 | Dismantling G.I. sheets roofing including ridges, hipsvalleysandguttersetc.andstackingthe material within 50 meters lead. |
| 5 | Providing and fixing colour coated galvulium roofingsheetsof0.5mmthicknessincludingall theaccessories(TATAmake)butexcludingthe cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 6 | Addforproviding&fixingFlashings-[Corners, Ridges,valleys,gableend&Trims](Girthupto 610mm)includingalltheaccessoriescomplete as per the directions of the Engineer in charge. |
| 7 | Repairstoplasterinpatchesof2.5sq.m.and underincludingcutting thepatchinproper shape and preparing and plastering the surface of the walls complete including disposal of rubbishtothedumping groundwithin50mlead. |
| 8 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 9 | Dismantlingthetileworkinfloorsandroofs laidincementincludingstackingofmaterials within 50metersleadforthicknessoftiles 10mm to 25mm. |
| 10 | Demolishing cement concrete 1:4:8 or leaner mixincludingdisposalofmaterialwithin50m lead. |
| 11 | Dismantling doors, windows andclearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead |
| 12 | a) Of area 3 sq.m. and below |
| 13 | Removingwhiteorcolourwashbyscrapping, sandpaperingandpreparingsurfacesmooth including necessary repairs to scratches etc. complete. |
| 14 | Paintingoneormorecoatsofacryllicexterior paintofapprovedbrandandmanufacture(Such as Dulex/ Asian Paints/ Sherwin Willians) on old workincludingcleaningthesurfacewithwater etc. complete. |
| 15 | Removingdryoroilbounddistemperby scrapping sand papering and preparing the surfacesmoothincludingnecessaryrepairsto scratches etc. complete. |
| 16 | Distempering(one/morecoat)withoilbound washable distemper of approved brand and manufacture and of required shade on old work to give an even shade. |
| 17 | Rubble packingwith hardlaterite stone under floors including watering ramming and consolidatingetc.inpipelinetrenchesandother foundations complete. |
| 18 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering,shuttering,finishingand reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) |
| 19 | a) All works upto plinth level |
| 20 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement: 4 coarse sand in foundation uptoplinth level +Extraforlateritemasonryinallsizesin superstructure from floor I level upto floor V level. |
| 21 | 12mmcementplaster1:4(1cement:4fine sand) |
| 22 | 18mmcementplasterintwocoatsunderlayer 12mmthickcementplaster1:5(1cement:5 coarse sand) and top layer 6mm thick with cementplaster1:3(1cement:3coarsesand) finished with sponge. |
| 23 | Earthwork in excavation by mechanical means (hydraulicexcavator)/manualmeansinfoundation pipelinetrenchesdrain(notexceeding1.5min widthor10sq.m.onplan)includingdressingof sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplusexcavated soil asdirected withinalead of 50 m. |
| 24 | a) All kinds of soil |
| 25 | Making plinth protection 50mm thick of Cement Concrete 1:3:6 (1cement: 3 Coarse Sand: 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry laterite aggregate 40mm nominal size well rammed and consolidated and groutedwithfinesandincludingfinishingthe top smooth. |
| 26 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24/15x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25/15 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24/15 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer. |
| 27 | a) GIMetalCeilingLayinplainTegular/Bevelled edgeGlobalwhitecolortilesofsize595x595 mm,and0.4-0.5mmthickwith8mmdrop; madeofGIsheethavinggalvanizingof100 gms/sqm (both sides inclusive) and electro staticallypolyesterpowdercoatedofthickness 60 microns (minimum), including factory painted after bending. |
| 28 | Providing and fixing anodized aluminium shutters in accordance with the specification annexedwithGoascheduleofRates(2004)Vol & II including all taxes, transportation, scaffoldingandhandlingetc.completeasper directionoftheEngineer-in-charge:Adjustable louvered windows. |
| 29 | c) Figured glass |
| 30 | Providing and fixing anodized aluminium shutters in accordance with the specification annexedwithGoascheduleofRates(2004)Vol & II including all taxes, transportation, scaffoldingandhandlingetc.completeasper direction of the Engineer-in-charge: Single or double leaf door shutters.+Extraforpowdercoatingwithpurepolyester powder of shade of required colour on the aluminium section |
| 31 | c) Figured glass |
| 32 | Colour glazed tiles 6 mm thick in skirtings risers ofsteps,dadolaidonabedof12mmthick cementplaster1:3(1cement:3coarsesand) jointed with white cement slurry. |
| 33 | Providing and and laying antiskid floor tiles 12 x 12upto16x16inofJohnson,Somany,Kajaria (thicknesstobespecifiedbythemanufacturer) of1stqualityconformingtoIS:15622of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarsesand)includingpointingthejointswith whitecementandmatchingpigmentetc., complete |
| 34 | b) LightShades |
| 35 | Providing and fixing coloured ceramic tiles spartek or equivalent of 12\" x 12\" size and 6 mm thick in floors thread of stepsand landing on 25 mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 36 | SolidPVCdoorframeinprelaminatedcolour: Providing and fixing factory made polyvinyl chloride(PVC)DoorFrame inPrelaminated colourofthesize50mmwidth,47mmheight withawallthicknessof5mm(±0.25),madeout of extruded 5mm(±0.25) thick PVC Sheet of Density600Kg/CbmManufacturedbyanISO- 9000 certified Company , having pattam width of 50mmandthicknessof10mmproviding weathersealNon-wovenselfadhesivegasket throughouttheframe.Allthreeframelengths reinforcedwith19mmx19mmM.S.squaretube of 19 gauge. mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15mmx15mm M.S. square tube. The door frame shallbefixedtothewallusing8/100mmlong M.S.ScrewsthroughtheframebyusingPVC fasteners.Aminimumof4nos.ofscrewstobe provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge. |
| 37 | Providingandfixing30mmthick factorymade solid panel (PVC) door shutter consisting of frame made out of M.S.tubes of 19 guage thickness and size of 40mm x 20mm for stiles as wellastop,lock&bottomrail.M.S.Frameshall haveacoatofmetalprimerofapprovedmake andmanufacture.M.S.Frameshallbecovered withheatmouldedprelam/Plain\"C\"channel made from 5mm (±0.25) thick PVC Sheet of Density600Kg/CbmManufacturedbyanISO- 9000certifiedCompany,ofsize30thickness, 110mmwidthformingstilesinwhich100mm should be flat & 5mm should be taper, and 5mm (±0.25)thick,135mmwidePVCSheetfortop rail and bottom rail in which 125 mm should be flat & 5mm taper on either side of panel. also for lock rail 145 mm sheet ,125 mm should be flat & 5mmtaperoneitherside.Anadditional5mm thick PVC strip of 20mm width is to be stuck on theinteriorsideofthe\"C\"ChannelusingPVC solventcementadhesive.Panellingof10mm PrelamPVCsheettobefittedintheM.S.Frame welded/sealedtothestiles&railswith30mm wide x 5mm(±0.25) thick PVC sheet beading on either side and additional 30mm wide PVC beading as gap insert below top and bottom rail joined together using solvent cement adhesive.15mm thick (5mm(±0.25) x 3) , 20mm widecrossPVCsheetasgapinsertfortop& bottomrail.Doorto befixedwithframewith 3 Nos. M.S powder coated butt hinges of size 100mm*25mm*2mmand50mmlongsteel screws drilled suitable to pass through both the wallsoftheM.Stube.Otherhardwareofdoor should be fixed with 25mm*8mm size steel screwsetc.completeasperdirectionof Engineer-in-charge, manufacturer\"s specificationand drawing. |
| 38 | Providing and fixing chromium plated brass rising hinges with necessary screws etc. complete. (right or left) |
| 39 | c) 100 mm |
| 40 | ProvidingandfixingPrinceorequivalentmake PVCSWRhalfroundeavesgutterwithbolts, nuts and flat iron brackets 40 x 3 mm size complete. |
| 41 | c) 250 mm nominal size |
| 42 | Providing& fixing chromium plated brass tower bolts(barreltype)withnecessaryscrews complete. |
| 43 | a) 250 x 10 mm |
| 44 | Providing and fixing chromium plated brass sliding door bolt with bolts, nuts and screws etc. complete. |
| 45 | b) 250 x 16 mm |
| 46 | Providingandfixingbrightfinishedbrass handles with necessary screws etc complete |
| 47 | b) 100 mm |
| 48 | Providingflatironholdfast40cmincluding fixingtoframewith10mmdiabolts,nutsand wooden plugs and embeded in cement concrete block 30 x10 x15 cm 1:3:6 mix(1cement: 3 coarsesand:6stoneaggregate20mmnominal size. |
| 49 | a) 40 x 3 mm flat iron hold fast 40 cm long |
| 50 | Providingandfixingwhitevitreouschinaflat back or wall corner type lipped front urinal basinof 430 x 260 x350 mm and 340 x 430x 265mmsizesrespectivelywithpvcautomatic flushing cistern with fittings, R.S. or C.I. brackets, standardsize galvanisedsteelflushpipeand spreaders with brass unions & G.I. clamps complete,includingpaintingofcisterand fittings,cuttingandmakinggoodthewallsandfloors where required. |
| 51 | b) Rangeoftwourinalbasinwith10litrespvc. Automatic flushing |
| 52 | Provingandfixingwhitevitreouschinawater closetsquattingpan(Indiantypew.c.pan)size 580 mm with 100 mmsand cast iron P. or S trap10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mm diameterP.V.Ctelescopicflushpipewithfit tingsandclamps25mmP.V.C.overflowpipe with specials & mosquito proof coupling of approvedmunicipaldesignandnylonpull complete cutting and making good the walls and floors where required. |
| 53 | b)Orissa pattern W.C. pan |
| 54 | Provingandfixingwhitevitreouschinawater closetsquating(Europeantypew.c.pan)with seat and lid, C.P. brass hinges and rubber buffers 10 lts. High level P.V.C.. flushing cistern (of approved make) with fittings,rack bolts 32 mm diameterP.V.C. telescopicflushpipewith fit tings and clamps 25mm P.V.C.. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon. chain and pull complete, cutting and making good the wallsad floors where required. |
| 55 | a) W.C. pan with white plastic seat and lid. |
| 56 | Providingandfixingvitreouschinawashbasin withRSorC.I.bracketspaintedwhite,15mmC.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good thewalls where required. |
| 57 | a) Flatbackwashbasinsize630x450mmwitha pair of 15 mm C.P. brass pillar taps. |
| 58 | Providingandfixingbrassbibcock(heavy)of approved quality : |
| 59 | a) 15 mm nominal bore |
| 60 | Providing and fixing NICKEL chrome plated copperalloyFancyPillarCockwithextended leverhandleandwallflangeConfirmingtoIS 8931; 1993 15mm nominal bore |
| 61 | Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent. Confirming to IS 8931;1993 |
| 62 | Providing and fixing NICKEL chrome plated copper alloy Fancy wall mixer with 115mm long bendpipeforconnectiontooverheadshower Jaquar make or equivalent. Confirming to IS 8931;1993 |
| 63 | a)Wallmixerwith115mmlongbendpipefor connection to over head shower. |
| 64 | ProvidingandfixingnahanitrapofrigidPVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : |
| 65 | a) 110 mm dia |
| 66 | Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with sheetflance 20mmJaquarmakeorequivalent. Confirming to IS 8931;1993 |
| 67 | a)20mm nominal bore |
| 68 | Providing and fixing C.P. brass shower rose with 15 or 20 mm. Inlet: |
| 69 | a) 100 mm diameter. |
| 70 | Providing & fixing c.p. brass towel rail complete withC.P.brassbracketsfixedtowoodencleats with C. P. brass screws |
| 71 | a) 750 x 20 mm size |
| 72 | Providingandfixing600x450mmbevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheetgroundfixedtowoodencleatswithC.P. brass screws and washers. |
| 73 | Providing and fixing NICKEL chrome plated copperalloyFancywastecoupling32mmwith 190 mm long connection pipe wall flanceJaquar make or equivalent. Confirming to IS 8931;1993 |
| 74 | Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door : |
| 75 | a) 110 mm dia |
| 76 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes ofapproved including lubricant etc. complete (single/double) socketed: |
| 77 | a) 110 mm dia |
| 78 | ProvidingandfixingHandShower(Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hookof approved quality confirming to IS standards. |
| 79 | Providingandfixingchlorinatedployvinyl chloride(CPVC)pipesconfirmingtoIS:15778, havingthermalstabilityforhotandcoldwater supplyincludingallCPVCplainandbrass threaded fittingsincluding fixing thepipeswith clamps at 1 mt. spacing.This includes jointing of pipesandfittingswithonestepCPVCsolvent cementandtestingofjointscompleteasper directionoftheEngineer-in-charge.Concealed work(mediumdutySDR13.5pipe)includingcutting chases and making good the walls etc. |
| 80 | b)20 mm dia nominal outer dia pipes. |
| 81 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with onestepUPVCsolventcement,trenching ,refilling & testing of joints complete as per direction of Engineer. External work. |
| 82 | I) SCH-80(blue)/(white) |
| 83 | b) 25mm outer dia. |
| 84 | c) 32mm outer dia. |
| 85 | e) 50mm outer dia. |