| 1 | 14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 2 | 15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar |
| 3 | 50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 4 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | 13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) |
| 6 | 50.18.9.17.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing.This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall |
| 7 | 50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall |
| 8 | 50.18.9.20.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm diaBend |
| 9 | 50.18.9.20.5 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 10 | 50.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 11 | od485/2021_2022 : Labour charges for Dismantling the damaged G.I. sheet roofing |
| 12 | od487/2021_2022 : Labour charges for Dismantling the damaged Asbestos sheet roofing |
| 13 | od486/2021_2022 : Beldar engaged for assisting fitter and cleaning the premises |
| 14 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 15 | 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 18 | od501/2021_2022 : Roofing with pre-painted alu zinc (galvalum) trapizoidal sheet of 0.50 mm thick or nearest available thickness with over lap of 150 mm at ends. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling steel screws/cranck bolt as per direction of departmental officers including plane washer and bituminouse washers,self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 19 | od500/2021_2022 : Providing Ridge or Hip with pre-painted alu-zinc (factory made-galvalum ) 150 GSM plane sheet 450 mm wide over lap of 150mm at joints including necessary bolts,washers etc, suitable to profile or corrugated sheets, complete |
| 20 | od488/2021_2022 : Providing Ridge or Hip with pre-painted alu-zinc 150 GSM plane sheet 900 mm wide over lap of 150mm at joints including necessary bolts,washers etc, suitable to profile or corrugated sheets,complete |
| 21 | 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 22 | od502/2021_2022 : Carpenter engaged for repair of wooden doors and windows |
| 23 | 14.6.1 : Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of thickness 4 mm |
| 24 | od565/2021_2022 : Supplying and fixing aluminium flat to Thermal insu-board ceiling with 45mm wide, 1 mm thick, smooth edges 190gm/m including fixing with 20mm long self drilling screws @ 30 cm and flat laying 60cm distance through out the area as per direction of engineer in charge |
| 25 | od568/2021_2022 : Providing and fixing Ceiling with Extruded polythene thermal insulation board 20 mm thick for dropped and damaged old false ceiling in true horizontal level to the existing false ceiling level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) exposed face of polythine thermal insulation board shall be painted with Acrylic Smooth interior paint of two coat of required shade over a priming coat etc. all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge |
| 26 | 13.88 : Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete |
| 27 | 13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture ofrequired colour to give an even shade :One or more coats on old work |
| 28 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 29 | 13.111.1 : Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cementpaint surface |
| 30 | 13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |