Bids Are invited for 60 KVA Online UPS with Batteries & Accessories - Capacity (in kVA / kW): 60 KVA = 60 KW3 Ph Input / 3 Ph OutputTechnology and Capability ( Mandatory ):a) True Online configuration with double conversion UPS b) DSP based technology wit-Uttar Pradesh

Ministry Of Textiles has published Bids Are invited for 60 KVA Online UPS with Batteries & Accessories - Capacity (in kVA / kW): 60 KVA = 60 KW3 Ph Input / 3 Ph OutputTechnology and Capability ( Mandatory ):a) True Online configuration with double conversion UPS b) DSP based technology wit. Submission Date for this Tender is 22-12-2021. Miscellaneous Fasteners Tenders in Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30065318
Bids Are invited for 60 KVA Online UPS with Batteries & Accessories - Capacity (in kVA / kW): 60 KVA = 60 KW3 Ph Input / 3 Ph OutputTechnology and Capability ( Mandatory ):a) True Online configuration with double conversion UPS b) DSP based technology wit
Tender
Indian
Uttar Pradesh
22-12-2021

Tender Details

Bids Are invited for 60 KVA Online UPS with Batteries & Accessories - Capacity (in kVA / kW): 60 KVA = 60 KW3 Ph Input / 3 Ph OutputTechnology and Capability ( Mandatory ):a) True Online configuration with double conversion UPS b) DSP based technology with reduction in electronic components.c) Possibility of enhancing UPS capacity / redundancy by operating UPS in N+X Parallel Redundant Configuration(PRS).d) Capability of Independent or Common battery bank operation of the UPS when operated in PRS.e) Dual Input design.f) UPS should have IGBT topology for both PFC (power factor correction) and inverter.g) Should have Dual Aux power design.h) FAN redundancy (if one fan fail UPS should be able to handle at least 80% of the load.)Input Voltage Range:220/380V,230/400V,240/415V (3F4W)Range (Full Load) 173~276 / 300~477VACRange (Derating to 70% Load) 132~173 / 228~300VACNominal Output voltage: 220/380V,230/400V,240/415V (3F4W)Backup Required :30 Minutes on Full LoadBattery Bank Voltage : Minimum 504 V DC or higherBattery Bank VAh : Minimum VAH - minimum 48000 VAHBatteries Type : Sealed Maintenance Free (SMF) - 12V CellsBattery Makes : Amara Raja / Exide / HBLNumber of Battery Banks : Maximum Two Banks in parallelNote: Please see the uploaded specification in PDF format for more details. Total Quantity : 1

Key Value

Document Fees
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail