construction of school Work Sadasar 4 Civil Work At Gsss, Sadasar Acr 4 Block - Sardarshahar Sl. No. Item Description 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Tr, VILLAGE POST - SADAASAR-Rajasthan

RAJASTHAN COUNCIL OF SCHOOL EDUCATION has published construction of school Work Sadasar 4 Civil Work At Gsss, Sadasar Acr 4 Block - Sardarshahar Sl. No. Item Description 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Tr. Submission Date for this Tender is 29-11-2021. Building Work Tenders in VILLAGE POST - SADAASAR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

30055097
construction of school Work Sadasar 4 Civil Work At Gsss, Sadasar Acr 4 Block - Sardarshahar Sl. No. Item Description 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Tr
Indian
Rajasthan
VILLAGE POST - SADAASAR
29-11-2021

Tender Details

construction of school Work Sadasar 4 Civil Work At Gsss, Sadasar Acr 4 Block - Sardarshahar Sl. No. Item Description 1 Part A Civil Work 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sum On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 P.C.C. In Foundation Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8 ( 1 Cement:4 Coarse Sand :8 Gradeed Stone Aggregate 40 Mm Nominal Size ) . 4 Brick Work Masonary With F.P.S Bricks Of Ist Class Desgnation In Foundation And Plinth In. Cement Sand Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 5 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Includingrubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand Light Shade Using Shade Cement. ) 6 Dpc:-Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required Excluding The Cost Of Centering, Shuttering And Reinforcement . M20 Grade Nominal Mix / Design Mix. 7 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 8 Brick Work Masonary With F.P.S Bricks Of Ist Class Desgnation In Supersture Above Plinth Level Upto Floor Vth Level In All Shapes And Sizes In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 9 Pillar Masonary :- Brick Work Masonary With F.P.S Bricks Of Ist Class Desgnation In Supersture Above Plinth Level Upto Floor Vth Level In All Shapes And Sizes In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 10 Stone Kharanja: Rr Dry Stone Kharanja Under Floor 11 Lintel Beams:-Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( As Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 12 Slab & Beam:-Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( As Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix 13 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchorblocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. 14 Steel Reinforcement:-P / F Reinforcement For Rcc Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Upto Floor Five Leve Tmt Bars ( Conforming Of Relevent Is Code ) . 15 Door Frames:-Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.Angle Iron ( 40X40x5mm. @ 3 Kg / M ) 16 Doors:-Providing And Fixing M.S. Sheet 1 Mm Thickdouble Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint. Add Extra For Double Leaf Shutters 17 Glazed Window:Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13X3mm, 10Cm. Long Embedded In Cement Concrete Block 15X10x10cm. Of 1:3:6 ( 1Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :Partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33% ] 18 Wire Gauge Supplying & Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 19 Guard Bars: P&F Square Bars Or Other Flat Welded To Window / Ventilators Etc. 20 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) For Area Of Each Slab From 2001 To 5000 Sq.Cm 21 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete ( For Area Of Each Slab Upto 2001Sqcm ) 22 Internal Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12 Mm Thick 23 External Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 20 Mm Thick 24 Plaster ( Ceiling ) : 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 ( 1 Cement: 3 Fine Sand ) 25 Black Board : Plaster On New Surface On Wall In Cement Sand Mortar 1:3 Including Raking Of Joints Etc. Complete Fine Finish: 12 Mm Thick 26 Grading Roof For Water Proofing Treatment Withwater Proffing Compound: Cement Concrete 1: 2: 4 ( 1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size ) 27 Gola:- Providing Gola 75Mm X 75Mm In Cement Concrete 1:2:4 ( 1 Cement: 2 Coarse Sand: 4 Stoneaggregate 10 Mm And Down Gauge ) Including Finished With Cement Mortar 1:3 ( 1 Cement: 2 Fine Sand ) As Per Standard Design. 28 White Washing Three Or More Coats To Give An Even Shade On New Surfaces . 29 Inernal Finishing: Distempering With Dry Distemper Of Approved Brand Shade ( Two Or More Coats ) Of Requiredshade New Work , Over And Including Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 30 Exterior Finishing: Finishing Wall With Water Proofing Cement Paint Of Appd Brand & Manufacture And Of Reqd. Shade To Give An Even Shade Including All Scafolding New Work ( Three Or More Coats Applied At The Rate Of 3.84 Kg / 10 Sqm ) 31 Painting On Doors, Windows & Ramp Raling :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shadenew Steel Work ( 2 Or More Coat On New Work ) . 32 Copping: Cement Concrete Flooring 1:2:4 ( 1 Cement: 2 Course Sand: 4 Greded Stone Aggregate ) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 33 For Rain Water-P&F Rigid Pvc Pipe ( Is:4985 Mark ) Class Ii / ( 4 Kg. / Cm2. ) Approved Quality / Makeincluding Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 34 For Rain Water-P&F Rigid Pvc Pipe Fittings ( Is: 4985 Mark ) Of Approved Quality / Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5110Mm Dia 35 Pipe Clip110 Mm Dia 36 Supply & Fixing Of Stainless Steel Pipe Railing For Ramp Railing Height, 90 Cm. With 40 Mm Dia Stainless Steel Pipe With 18 Gauge With Drop ( Vertical Post ) At 90 Cm C / C And Intermidiate Horizontal Pipe With Suitable Height Of Same Size And Gauge With Coupling, Grinding And Polishing & Fix Of Master Pieces As Per Required Point As Per Approved Design Of Engineer Incharge. 37 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 38 Part B Electrical Work 39 Wiring Of Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvcinsulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is: 694 ) Of Approved Make Group-2 40 Light Point 41 Short Point ( Up To 3 Mtr. ) 42 Medium Point ( Up To 6 Mtr ) 43 Long Point ( Up To 10 Mtr ) 44 Fan Point 45 Short Point ( Up To 3 Mtr. ) 46 Medium Point ( Up To 6 Mtr ) 47 Long Point ( Up To 10 Mtr ) 48 Wiring Of 3 Pin 5 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvcinsulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is: 694 ) Of Approved Make In Surface / Reces Group - On Board 49 S & F Follwing Sizes ( Dia. ) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface / Recessed Using Clamps, Fastener As Required Including Cutting The Wall , Covering Conduit With Wire Mess And Making Good The Same As Required. Group-225 Mm Dia 50 Supplying And Drawi;Ng Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi Marked ( Is:694 ) Of 1.1 Kv Grade And Approved Make In Existing Surface Ofr Necessed Conduit / Casting Capping Including Making Connections Etc. As Required. Group-2 51 1 X 1.5 Sq. Mm 52 2 X 1.5 Sq. Mm 53 2 X 2.5 Sq. Mm 54 P & F 240 / 415 V Mcb Of Breaking Capacity Not Less Than 10 Ka ( B / C / D Tripping Characteristic ) Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898 In Existing Board / Sheets Including Making Connections With Lugs, Testing Etc. As Required. Group-2 6 A To 32 A Rating 55 P & F Recessed / Surface Mounting Heavy Duty Horizontal Type Sheet Steel Distribution Board Phophatised / Powder Painted Complete With 100 Amp Copper Copper Bus Bar, Shorting Link, Neutral, Earth Link And Din Bar, Conforming To Is 13032 & Is 8623 Including Making Internal Db Termination With Copper Lux, Testing Etc. As Reqd. . Group-2Single Door ( Single Phase ) 8 Way 56 P & F Strip Fluorscent Tube Fitting Fabricated From ( Crca Sheet And Finished With Powder Coating / Stove Enamelled Non Corrosive Uv Resist Ep Channel ) Complete With Accessories ( Low Loss Copperchoke, Starter, Starter Seat ) / Electronic Choke With Terminal Block Duely Prewired With Copper Conducter Including Making Connection, Testing Etc. As Required ( Without Tube ) 1X36 Watts With Occb. Group-2 57 P & F Fluorscent Tube Rod In Existing Fixtures As Required, Minimum 3 Star Rating, 36 / 40 Watts 58 P / I Aying Pvc Insulated & Pvc Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Of Is:1554 P-I Of Groups Of Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cm X 75Cm Size Trench, 25Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 6 Sqmm, 4 Core Arm 59 P & F Star Rated Double Ball Beari;Ng Capacitor Start, Aluminium Bodyand Blade Ceiling Fan With Down Rod Upto 30 Cm With 3X1.5 Sqmm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc As Required.1200 Mm Sweep 3 Star Rated 60 P & F Is:371 Marked 6 Amp Suffacetype Celling Roseinculuding Making Commection Testing Etc. Grup-2 ( E071400 ) 61 P & F Isi Marked 6 Amp Bakelite Batten / Angle Holder Including Making Connextion Testing Etc As Required 62 P & F 18 Swg Ms Recessed Fan Box, Hexagonal / Round Of Size 130Mm Dia, Depth 75 Mm , 12Mm Dia Rad Fan Hookwith 100Mm Length Extended On Eeach Side. Gourp-1 63 P & F 18 Swg Sheet Steel Boxes Duly Finisded With Two Coats Of Red Oxide And With Earthing Terminal Of Following Sizes ( Nominal Size ) On Surfacae Or In Recessed As Required. 175 Mmx 100 Mmx60 Mm 64 P & F Paper Phenolic Resin Bonded Laminates Confirming To Is: 2036- 1995 For Boxes / Frames Including Making Holes For Switches Etc With Brass Screws Washers / Zink Plated Nut And Bolts As Required With 3Mm Thick 65 P & F Socket Size Flush Type 120 / 280 Watt Rotary 5 Step Fan Regulator Including Making Connection Testing Etc. As Required. 66 P & F Socket Size Flush Type 120 / 280 Watt Rotary 5 Step Fan Regulator Including Making Connection Testing Etc. As Required.

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: CIVIL WORK AT GSSS, SADASAR ACR 4 BLOCK - SARDARSHAHAR
Sl. No. Item Description
1PART A CIVIL WORK
2Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils
3P.C.C. IN FOUNDATION Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 gradeed stone aggregate 40 mm nominal size).
4Brick Work masonary with F.P.S bricks of Ist Class Desgnation in Foundation and plinth in. Cement Sand Mortar 1:6 ( 1 Cement :6 Coarse sand)
5Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand Light shade using shade cement.)
6DPC:-Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required excluding the cost of centering, shuttering and reinforcement . M20 Grade Nominal Mix/Design mix.
7Supply & Stacking good earth at site complete including loading unloading & transporation etc.
8Brick Work masonary with F.P.S bricks of Ist Class Desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in Cement mortar 1:6 ( 1 Cement :6 Coarse sand)
9Pillar Masonary :- Brick Work masonary with F.P.S bricks of Ist Class Desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in Cement mortar 1:4 ( 1 Cement :4 Coarse sand)
10Stone Kharanja: RR Dry stone kharanja under floor
11Lintel Beams:-Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
12Slab & Beam:-Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
13Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.
14Steel Reinforcement:-P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire)all complete upto floor five leve TMT bars (Conforming of relevent IS Code).
15Door Frames:-Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.angle iron (40x40x5mm. @ 3 kg/m)
16Doors:-Providing and fixing M.S. sheet 1 mm thickdouble leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint. Add extra for double leaf shutters
17Glazed Window:Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Partly fixed and partly openable [ fixed area not to exceed 33%]
18Wire Gauge Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at not exceeding 150 mm distance.
19Guard Bars: P&F square bars or other flat welded to window/ventilators etc.
20Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm
21Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete(For area of each slab upto 2001Sqcm)
22Internal Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick
23External Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick
24Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand)
25Black Board : Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick
26Grading roof for water proofing treatment withwater proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size)
27Gola:- Providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stoneaggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design.
28White washing three or more coats to give an even shade on new surfaces .
29Inernal Finishing: Distempering with dry distemper of approved brand shade ( two or more coats ) of requiredshade new work , over and including priming coat of whiting to give an even shade including all scaffolding.
30Exterior Finishing: Finishing wall with water proofing cement paint of appd brand & manufacture and of reqd. shade to give an even shade including all scafolding New work (three or more coats applied at the rate of 3.84 kg/10 sqm)
31Painting On Doors, Windows & Ramp Raling :- Painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shadenew steel work (2 or more coat on new work).
32Copping: Cement concrete flooring 1:2:4 (1 cement: 2 Course sand: 4 Greded stone aggregate) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate.
33For rain water-P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
34For rain water-P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5110mm dia
35Pipe Clip110 mm dia
36Supply & fixing of stainless steel pipe railing for ramp railing height, 90 cm. with 40 mm dia stainless steel pipe with 18 gauge with drop ( vertical post) at 90 cm C/C and intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of engineer incharge.
37Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4.
38PART B ELECTRICAL WORK
39Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make group-2
40Light point
41Short point (up to 3 mtr.)
42Medium point (up to 6 mtr)
43Long point (up to 10 mtr)
44Fan point
45Short point (up to 3 mtr.)
46Medium point (up to 6 mtr)
47Long point (up to 10 mtr)
48Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make in surface/reces group - On board
49S & F follwing sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. Group-225 mm dia
50Supplying and drawi;ng FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. Group-2
511 x 1.5 sq. mm
522 x 1.5 sq. mm
532 x 2.5 sq. mm
54P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. Group-2 6 A to 32 A rating
55P & F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 Amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB termination with copper lux, testing etc. as reqd. . group-2Single door(Single Phase) 8 way
56P & F strip fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/stove enamelled non corrosive UV resist EP channel)complete with accessories(Low loss copperchoke, starter, starter seat)/Electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(Without tube)1x36 watts with OCCB. Group-2
57P & F Fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts
58P/I aying PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:1554 P-I of Groups of approved make in ground as per IS:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, Iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm
59P & F star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated
60P & F IS:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup-2 (E071400)
61P & F ISI marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required
62P & F 18 swg MS Recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp-1
63P & F 18 SWG Sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmX 100 mmX60 mm
64P & F paper phenolic resin bonded laminates confirming to IS: 2036- 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick
65P & F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required.
66P & F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail